Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 214
Filtrar
2.
Heart Rhythm ; 2024 Oct 18.
Artigo em Inglês | MEDLINE | ID: mdl-39427688

RESUMO

BACKGROUND: Aveir™ DR (Abbott) is a dual-chamber leadless pacemaker (LP) system with distinct atrial and ventricular LPs (ALP, VLP) that communicate wirelessly to deliver atrioventricular synchronous pacing. Success rates of these implant-to-implant (i2i™) transmissions have not been systematically evaluated. OBJECTIVE: To evaluate chronic i2i success rates in a clinical setting. METHODS: Patients meeting standard dual-chamber pacing indications were enrolled and implanted with dual-chamber LP systems as part of a prospective, international clinical trial ("Aveir DR i2i Study"). The percent of successful i2i transmissions from ALP-to-VLP (A-to-V) and VLP-to-ALP (V-to-A) were interrogated from LPs in de novo patients using the device programmer at implant, discharge, and at 1-, 3-, and 6-months post-implant (1M, 3M, 6M). RESULTS: 399 patients completed device implant and i2i diagnostic interrogation (62% male; age 69 years; 65% sinus node dysfunction, 32% AV block). Median A-to-V and V-to-A i2i success rates exceeded 90% of beats at all time-points from implant to 6M. The minority of patients with A-to-V or V-to-A i2i success in <70% of beats at implant (A-to-V: 19% of patients, V-to-A: 31% of patients) showed roughly 40% improvement by 1M, with this minority dropping to roughly 5% of patients by 6M. Improvement in i2i communication success may be attributed to reprogramming of i2i setting levels, natural changes in dominant posture, and device stabilization. CONCLUSION: Wireless implant-to-implant communication in the new dual-chamber leadless pacemaker system demonstrated successful transmissions in >90% of beats throughout the 6-month evaluation period. Communication success improved significantly over time post-implant for specific subgroups.

3.
Arch Cardiovasc Dis ; 117(8-9): 542-557, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39271364

RESUMO

Atrial fibrillation (AF) is the primary cause of ischaemic stroke and transient ischaemic attack (TIA). AF is associated with a high risk of recurrence, which can be reduced using optimal prevention strategies, mainly anticoagulant therapy. The availability of effective prophylaxis justifies the need for a significant, coordinated and thorough transdisciplinary effort to screen for AF associated with stroke. A recent French national survey, initiated and supported by the Société française neurovasculaire (SFNV) and the Société française de cardiologie (SFC), revealed many shortcomings, such as the absence or inadequacy of telemetry equipment in more than half of stroke units, insufficient and highly variable access to monitoring tools, delays in performing screening tests, heterogeneous access to advanced or connected ambulatory monitoring techniques, and a lack of dedicated human resources. The present scientific document has been prepared on the initiative of the SFNV and the SFC with the aim of helping to address the current shortcomings and gaps, to promote efficient and cost-effective AF detection, and to improve and, where possible, homogenize the quality of practice in AF screening among stroke units and outpatient post-stroke care networks. The working group, composed of cardiologists and vascular neurologists who are experts in the field and are nominated by their peers, reviewed the literature to propose statements, which were discussed in successive cycles, and maintained, either by consensus or by vote, as appropriate. The text was then submitted to the SFNV and SFC board members for review. This scientific statement document argues for the widespread development of patient pathways to enable the most efficient AF screening after stroke. This assessment should be carried out by a multidisciplinary team, including expert cardiologists and vascular neurologists.


Assuntos
Fibrilação Atrial , Cardiologia , Ataque Isquêmico Transitório , AVC Isquêmico , Valor Preditivo dos Testes , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/complicações , Fibrilação Atrial/terapia , Fibrilação Atrial/fisiopatologia , Cardiologistas , Cardiologia/normas , Consenso , França/epidemiologia , Ataque Isquêmico Transitório/diagnóstico , Ataque Isquêmico Transitório/etiologia , Ataque Isquêmico Transitório/terapia , Ataque Isquêmico Transitório/prevenção & controle , AVC Isquêmico/diagnóstico , AVC Isquêmico/etiologia , AVC Isquêmico/prevenção & controle , AVC Isquêmico/terapia , Prognóstico , Recidiva , Fatores de Risco
4.
Heart Rhythm ; 2024 Sep 27.
Artigo em Inglês | MEDLINE | ID: mdl-39343120

RESUMO

In a pivotal trial (NCT05252702), the AVEIR DR (Abbott) leadless pacemaker system was found to be safe and effective in delivering DDDR synchronous atrial and ventricular pacing. This dual-chamber system employs 2 leadless pacemakers with implant-to-implant communication. Although implantation of the ventricular device as a single-chamber pacemaker has been well described, there are additional considerations surrounding the dual-chamber implantation procedure. Herein, we review the dual-chamber leadless pacemaker implantation workflow while providing guidance to optimize safe and effective implantation procedures.

5.
Eur Heart J ; 2024 Sep 20.
Artigo em Inglês | MEDLINE | ID: mdl-39299922

RESUMO

BACKGROUND AND AIMS: Prophylactic implantable cardioverter-defibrillators (ICDs) are not recommended until left ventricular ejection fraction (LVEF) has been reassessed 40 to 90 days after an acute myocardial infarction. In the current therapeutic era, the prognosis of sustained ventricular arrhythmias (VAs) occurring during this early post-infarction phase (i.e. within 3 months of hospital discharge) has not yet been specifically evaluated in post-myocardial infarction patients with impaired LVEF. Such was the aim of this retrospective study. METHODS: Data analysis was based on a nationwide registry of 1032 consecutive patients with LVEF ≤ 35% after acute myocardial infarction who were implanted with an ICD after being prescribed a wearable cardioverter-defibrillator (WCD) for a period of 3 months upon discharge from hospital after the index infarction. RESULTS: ICDs were implanted either because a sustained VA occurred while on WCD (VA+/WCD, n = 72) or because LVEF remained ≤35% at the end of the early post-infarction phase (VA-/WCD, n = 960). The median follow-up was 30.9 months. Sustained VAs occurred within 1 year after ICD implantation in 22.2% and 3.5% of VA+/WCD and VA-/WCD patients, respectively (P < .0001). The adjusted multivariable analysis showed that sustained VAs while on WCD independently predicted recurrence of sustained VAs at 1 year (adjusted hazard ratio [HR] 6.91; 95% confidence interval [CI] 3.73-12.81; P < .0001) and at the end of follow-up (adjusted HR 3.86; 95% CI 2.37-6.30; P < .0001) as well as 1-year mortality (adjusted HR 2.86; 95% CI 1.28-6.39; P = .012). CONCLUSIONS: In patients with LVEF ≤ 35%, sustained VA during the early post-infarction phase is predictive of recurrent sustained VAs and 1-year mortality.

6.
Circ Arrhythm Electrophysiol ; 17(10): e012732, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39212069

RESUMO

BACKGROUND: Pulsed field ablation (PFA) is increasingly used in clinical practice for the treatment of atrial fibrillation. While the susceptibility of erythrocytes to electroporation is well established, the effect of cardiac PFA technologies on hemolysis has remained underreported. The aim of this study was to investigate the incidence, severity, and clinical impact of PFA-induced hemolysis. METHODS: We included n=145 patients undergoing atrial fibrillation catheter ablation with a pentaspline PFA catheter (biphasic, bipolar pulses of 2 kV) and n=70 patients receiving radiofrequency ablation (40-90 W) at 4 high-volume European centers. The lesion set comprised pulmonary vein isolation for paroxysmal atrial fibrillation and pulmonary vein isolation±additional lesions for persistent atrial fibrillation. Hemolysis and renal function biomarkers were analyzed in blood samples at baseline, at the end of ablation, and 24 hours after the procedure. RESULTS: Baseline characteristics were well balanced between groups (overall mean 65.7±9.4 years; 69.3% men). The ablation procedures comprised a mean of 61.6±27.4 PFA deliveries and 26.3±15.0 minutes RF duration. Hemolysis was detected in 94.3% versus 6.8% of patients after PFA versus radiofrequency ablation (P<0.001): PFA was associated with significantly lower haptoglobin levels (0.5±0.4 versus 1.0±0.4 g/L), while free plasma hemoglobin (592.8±330.6 versus 147.8±183.0 mg/L), bilirubin (21.3±11.3 versus 14.8±8.8 µmol/L), and LDH (lactate dehydrogenase, 352.7±115.7 versus 253.2±56.5 U/L) were significantly higher after PFA compared with radiofrequency ablation (all P<0.001). Hemolysis correlated with the number of PFA deliveries (r=0.62 [95% CI, 0.33-0.80]; P<0.001), with the highest severity occurring ≥54 PFA deliveries. After PFA, hemoglobinuria occurred in 36.4%, while creatinine increase was higher in patients with baseline glomerular filtration rate <50 mL/min than with baseline glomerular filtration rate >50 mL/min (Δcrea, 27.0±103.1 versus -0.2±12.1 µmol/L; P=0.010). CONCLUSIONS: Intravascular hemolysis is a frequent finding after PFA and increases with the number of PFA deliveries. Until the clinical impact of PFA-associated hemolysis is fully elucidated, a careful titration of PFA deliveries during the ablation procedure is warranted.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Hemólise , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/sangue , Feminino , Masculino , Idoso , Ablação por Cateter/efeitos adversos , Pessoa de Meia-Idade , Resultado do Tratamento , Biomarcadores/sangue , Fatores de Tempo , Europa (Continente) , Veias Pulmonares/cirurgia , Veias Pulmonares/fisiopatologia , Incidência , Fatores de Risco , Relevância Clínica
7.
Heart Rhythm ; 2024 Aug 10.
Artigo em Inglês | MEDLINE | ID: mdl-39134129

RESUMO

BACKGROUND: SCN5A variants are associated with a spectrum of cardiac electrical disorders with clear phenotypes. However, they may also be associated with complex phenotypic traits like overlap syndromes or pleiotropy, which have not been systematically described. In addition, the involvement of SCN5A in dilated cardiomyopathies (DCMs) remains controversial. OBJECTIVE: We aimed to evaluate the different phenotypes associated with pathogenic (P)/likely pathogenic (LP) SCN5A variants and to determine the prevalence of pleiotropy in a large multicentric cohort of P/LP SCN5A variant carriers. METHODS: The DNA of 13,510 consecutive probands (9960 with cardiomyopathies) was sequenced with a custom panel of genes. Individuals carrying a heterozygous single P/LP SCN5A variant were selected and phenotyped. RESULTS: The study included 170 P/LP variants found in 495 patients. Of them, 119 (70%) were exclusively associated with a single well-established phenotype: 91 with Brugada syndrome, 15 with type 3 long QT syndrome, 6 with progressive cardiac conduction disease, 4 with multifocal ectopic Purkinje-related premature contractions, and 3 with sick sinus syndrome. Thirty-two variants (19%) were associated with overlap syndromes or pleiotropy. The 19 remaining variants (11%) were associated with atypical or unclear phenotypes. Of those, 8 were carried by 8 patients presenting with DCM with a debatable causative genotype/phenotype link. CONCLUSION: Most P/LP SCN5A variants were found in patients with primary electrical disorders, mainly Brugada syndrome. Nearly 20% were associated with overlap syndromes or pleiotropy, underscoring the need for comprehensive phenotypic evaluation. The concept of SCN5A variants causing DCM is extremely rare (8/9960) if not questionable.

8.
JAMA Cardiol ; 9(10): 871-879, 2024 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-39083254

RESUMO

Importance: Approximately 40% of patients with heart failure (HF) who are eligible for cardiac resynchronization therapy (CRT) either fail to respond or are untreatable due to anatomical constraints. Objective: To assess the safety and efficacy of a novel, leadless, left ventricular (LV) endocardial pacing system for patients at high risk for a CRT upgrade or whose coronary sinus (CS) lead placement/pacing with a conventional CRT system failed. Design, Setting, and Participants: The SOLVE-CRT study was a prospective multicenter trial enrolling January 2018 through July 2022, with follow-up at 6 months. Data were analyzed from January 17, 2018, through February 15, 2023. The trial combined data from an initial randomized, double-blind study (n = 108) and a subsequent single-arm part (n = 75). It took place at 36 centers across Australia, Europe, and the US. Participants were nonresponders, previously untreatable (PU), or high-risk upgrades (HRU). All participants contributed to the safety analysis. The primary efficacy analysis (n = 100) included 75 PU-HRU patients from the single-arm part and 25 PU-HRU patients from the randomized treatment arm. Interventions: Patients were implanted with the WiSE CRT System (EBR Systems) consisting of a leadless LV endocardial pacing electrode stimulated with ultrasound energy delivered by a subcutaneously implanted transmitter and battery. Main Outcomes and Measures: The primary safety end point was freedom from type I complications. The primary efficacy end point was a reduction in mean LV end systolic volume (LVESV). Results: The study included 183 participants; mean age was 68.1 (SD, 10.3) years and 141 were male (77%). The trial was terminated at an interim analysis for meeting prespecified stopping criteria. In the safety population, patients were either New York Heart Association Class II (34.6%) or III (65.4%). The primary efficacy end point was met with a 16.4% (95% CI, -21.0% to -11.7%) reduction in mean LVESV (P = .003). The primary safety end point was met with an 80.9% rate of freedom from type I complications (P < .001), which included 12 study device system events (6.6%), 5 vascular events (2.7%), 3 strokes (1.6%), and 7 cardiac perforations which mostly occurred early in the study (3.8%). Conclusions and Relevance: The SOLVE-CRT study has demonstrated that leadless LV endocardial pacing with the WiSE CRT system is associated with a reduction in LVESV in patients with HF. This novel system may represent an alternative to conventional CRT implants in some HF patient populations. Trial Registration: ClinicalTrials.gov Identifier: NCT0292203.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca , Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Humanos , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/fisiopatologia , Masculino , Feminino , Idoso , Terapia de Ressincronização Cardíaca/métodos , Estudos Prospectivos , Método Duplo-Cego , Pessoa de Meia-Idade , Resultado do Tratamento
9.
JACC Clin Electrophysiol ; 10(9): 1982-1994, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38970599

RESUMO

BACKGROUND: Idiopathic ventricular fibrillation (IVF) can be associated with undetected distinct conditions such as microstructural cardiomyopathic alterations (MiCM) or Purkinje (Purk) activities with structurally normal hearts. OBJECTIVES: This study sought to evaluate the characteristics of recurrent VF recorded on implantable defibrillator electrograms, associated with these substrates. METHODS: This was a multicenter collaboration study. At 32 centers, we selected patients with an initial diagnosis of IVF and recurrent arrhythmia at follow-up without antiarrhythmic drugs, in whom mapping demonstrated Purk or MiCM substrate. We analyzed variables related to previous ectopy, sinus rate preceding VF, trigger, and initial VF cycle lengths. Logistic regression with cross validation was used to evaluate the performance of criteria to discriminate Purk or MiCM substrates. RESULTS: Among 95 patients (35 women, age 35 ± 11 years) meeting the inclusion criteria, IVF was associated with MiCM in 41 and Purk in 54 patients. A total of 117 arrhythmia recurrences including 91% VF were recorded on defibrillator. Three variables were mostly discriminant. Sinus tachycardia (≤570 ms) was more frequent in MiCM (35.9% vs 13.4%, P = 0.014) whereas short-coupled (<350 ms) triggers were most frequent in Purk-related VF (95.5% vs 23.1%, P = 0.001), which also had shorter VFCLs (182 ± 15 ms vs 215 ± 24 ms, P < 0.001).The multivariable combination provided the highest prediction (accuracy = 0.93 ± 0.05, range 0.833-1.000), discriminating 81% of IVF substrates with a high probability (>80%). Ectopy were inconsistently present before VF. CONCLUSIONS: Characteristics of arrhythmia recurrences on implantable cardioverter- defibrillator provide phenotypic markers of the distinct and hidden substrates underlying IVF. These findings have significant clinical and genetic implications.


Assuntos
Desfibriladores Implantáveis , Fibrilação Ventricular , Humanos , Feminino , Fibrilação Ventricular/terapia , Fibrilação Ventricular/fisiopatologia , Masculino , Adulto , Pessoa de Meia-Idade , Recidiva , Cardiomiopatias/fisiopatologia , Cardiomiopatias/terapia , Cardiomiopatias/complicações , Ramos Subendocárdicos/fisiopatologia , Eletrocardiografia
11.
Circulation ; 150(6): 439-450, 2024 Aug 06.
Artigo em Inglês | MEDLINE | ID: mdl-38973458

RESUMO

BACKGROUND: A dual-chamber leadless pacemaker system has been designed for atrioventricular synchronous pacing using wireless, beat-to-beat, implant-to-implant (i2i) communication between distinct atrial and ventricular leadless pacemakers. The atrioventricular synchrony achieved across various ambulatory scenarios has yet to be systematically evaluated. METHODS: A prospective, single-arm, unblinded, multicenter, international clinical trial of the leadless pacemaker system was conducted in patients with a conventional dual-chamber pacing indication enrolled from February 2022 to March 2023. Leadless pacemaker systems were implanted, and 12-lead Holter electrocardiographic recordings were collected 3 months after implantation over various postures/activities: sitting, supine, left lateral recumbent, right lateral recumbent, standing, normal walk, and fast walk. An independent Holter core laboratory performed a manual adjudication of the percent of atrioventricular synchronous beats using the standard 300-millisecond PR interval limit. Atrium-to-ventricle and ventricle-to-atrium i2i communication success rates were also assessed. Post hoc summary statistics describing the relationships between atrioventricular synchrony and i2i success, posture/activity, implantation indication, atrioventricular event, and heart rate were calculated. RESULTS: In the evaluable population (n=384 of 464 enrolled [83%]; 61% male; age, 70 years; weight, 82 kg; 60% ejection fraction; 95% of beats evaluable), the mean atrioventricular synchrony of 98% of beats observed across all postures using the standard 300-millisecond limit was greater than both atrial-to-ventricular i2i (94%) and ventricular-to-atrial i2i (94%; P<0.001), exceeding both i2i values in 95% of patients. Atrioventricular synchrony was achieved in >95% of evaluable beats across all postures/activities, implantation indications, atrioventricular paced/sensed event combinations, and heart rate ranges (including >100 bpm). CONCLUSIONS: This dual-chamber leadless pacemaker system demonstrated atrioventricular synchrony in 98% of evaluable beats at 3 months after implantation. Atrioventricular synchrony was maintained across postures/activities and remained robust for heart rates >100 bpm.


Assuntos
Marca-Passo Artificial , Humanos , Masculino , Feminino , Idoso , Estudos Prospectivos , Idoso de 80 Anos ou mais , Frequência Cardíaca , Eletrocardiografia Ambulatorial , Pessoa de Meia-Idade , Estimulação Cardíaca Artificial/métodos
13.
Nat Med ; 30(7): 2020-2029, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38977913

RESUMO

Pulsed field ablation (PFA) is an emerging technology for the treatment of atrial fibrillation (AF), for which pre-clinical and early-stage clinical data are suggestive of some degree of preferentiality to myocardial tissue ablation without damage to adjacent structures. Here in the MANIFEST-17K study we assessed the safety of PFA by studying the post-approval use of this treatment modality. Of the 116 centers performing post-approval PFA with a pentaspline catheter, data were received from 106 centers (91.4% participation) regarding 17,642 patients undergoing PFA (mean age 64, 34.7% female, 57.8% paroxysmal AF and 35.2% persistent AF). No esophageal complications, pulmonary vein stenosis or persistent phrenic palsy was reported (transient palsy was reported in 0.06% of patients; 11 of 17,642). Major complications, reported for ~1% of patients (173 of 17,642), were pericardial tamponade (0.36%; 63 of 17,642) and vascular events (0.30%; 53 of 17,642). Stroke was rare (0.12%; 22 of 17,642) and death was even rarer (0.03%; 5 of 17,642). Unexpected complications of PFA were coronary arterial spasm in 0.14% of patients (25 of 17,642) and hemolysis-related acute renal failure necessitating hemodialysis in 0.03% of patients (5 of 17,642). Taken together, these data indicate that PFA demonstrates a favorable safety profile by avoiding much of the collateral damage seen with conventional thermal ablation. PFA has the potential to be transformative for the management of patients with AF.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/terapia , Feminino , Masculino , Pessoa de Meia-Idade , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Idoso , Resultado do Tratamento , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia
14.
Heart Rhythm ; 21(10): 1929-1938, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38697271

RESUMO

BACKGROUND: The first dual-chamber leadless pacemaker (DC-LP) system consists of 2 separate atrial and ventricular devices that communicate to maintain synchronous atrioventricular pacing and sensing. The initial safety and efficacy were previously reported. OBJECTIVE: The purpose of this study was to evaluate the chronic electrical performance of the DC-LP system. METHODS: Patients meeting standard dual-chamber pacing indications were enrolled and implanted with the DC-LP system (Aveir DR, Abbott), including right atrial and ventricular helix-fixation LPs (atrial leadless pacemaker [ALP], ventricular leadless pacemaker [VLP]). Pacing capture threshold, sensed amplitude, and pacing impedance were collected using the device programmer at prespecified timepoints from 0-6 months postimplant. RESULTS: De novo devices were successfully implanted in 381 patients with complete 6-month data (62% male; age 69 ± 14 years; weight 82 ± 20 kg; 65% sinus nodal dysfunction, 30% atrioventricular block). ALPs were implanted predominantly in the right atrial appendage anterior base and VLPs primarily at the mid-to-apical right ventricular septum. From implant to 1 month, pacing capture thresholds (0.4-ms pulse width) improved in both ALPs (2.4 ± 1.5 V to 0.8 ± 0.8 V; P <.001) and VLPs (0.8 ± 0.6 V to 0.6 ± 0.4 V; P <.001). Sensed amplitudes improved in both ALPs (1.8 ± 1.3 mV to 3.4 ± 1.9 mV; P <.001) and VLPs (8.8 ± 4.0 mV to 11.7 ± 4.2 mV; P <.001). Impedances were stable in ALPs (334 ± 68 Ω to 329 ± 52 Ω; P = .17) and reduced in VLPs (789 ± 351 Ω to 646 ± 190 Ω; P <.001). Electrical measurements remained relatively stable from 1-6 months postimplant. No differences in electrical metrics were observed among ALP or VLP implant locations. CONCLUSION: This first in-human evaluation of the new dual-chamber leadless pacemaker system demonstrated reliable electrical performance throughout the initial 6-month evaluation period.


Assuntos
Estimulação Cardíaca Artificial , Desenho de Equipamento , Marca-Passo Artificial , Humanos , Masculino , Feminino , Idoso , Estimulação Cardíaca Artificial/métodos , Seguimentos , Resultado do Tratamento , Ventrículos do Coração/fisiopatologia , Bloqueio Atrioventricular/terapia , Bloqueio Atrioventricular/fisiopatologia , Fatores de Tempo , Síndrome do Nó Sinusal/terapia , Síndrome do Nó Sinusal/fisiopatologia
15.
Heart Rhythm ; 21(6): 836-844, 2024 06.
Artigo em Inglês | MEDLINE | ID: mdl-38336193

RESUMO

BACKGROUND: The PRAETORIAN score estimates the risk of failure of subcutaneous implantable cardioverter-defibrillator (S-ICD) therapy by using generator and lead positioning on bidirectional chest radiographs. The PRospective randomized compArative trial of subcutanEous implanTable cardiOverter-defibrillatoR ImplANtation with and without DeFibrillation Testing (PRAETORIAN-DFT) investigates whether PRAETORIAN score calculation is noninferior to defibrillation testing (DFT) with regard to first shock efficacy in spontaneous events. OBJECTIVE: This prespecified subanalysis assessed the predictive value of the PRAETORIAN score for defibrillation success in induced ventricular arrhythmias. METHODS: This multicenter investigator-initiated trial randomized 965 patients between DFT and PRAETORIAN score calculation after de novo S-ICD implantation. Successful DFT was defined as conversion of induced ventricular arrhythmia in <5 seconds from shock delivery within 2 attempts. Bidirectional chest radiographs were obtained after implantation. The predictive value of the PRAETORIAN score for DFT success was calculated for patients in the DFT arm. RESULTS: In total, 482 patients were randomized to undergo DFT. Of these patients, 457 (95%) underwent DFT according to protocol, of whom 445 (97%) had successful DFT and 12 (3%) had failed DFT. A PRAETORIAN score of ≥90 had a positive predictive value of 25% for failed DFT, and a PRAETORIAN score of <90 had a negative predictive value of 99% for successful DFT. A PRAETORIAN score of ≥90 was the strongest independent predictor for failed DFT (odds ratio 33.77; confidence interval 6.13-279.95; P < .001). CONCLUSION: A PRAETORIAN score of <90 serves as a reliable indicator for DFT success in patients with S-ICD, and a PRAETORIAN score of ≥90 is a strong predictor for DFT failure.


Assuntos
Desfibriladores Implantáveis , Cardioversão Elétrica , Valor Preditivo dos Testes , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Cardioversão Elétrica/métodos , Estudos Prospectivos , Idoso , Morte Súbita Cardíaca/prevenção & controle , Morte Súbita Cardíaca/etiologia , Medição de Risco/métodos , Taquicardia Ventricular/terapia , Taquicardia Ventricular/fisiopatologia , Fibrilação Ventricular/terapia
16.
Arch Cardiovasc Dis ; 117(3): 224-231, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38302391

RESUMO

Sustainability in healthcare, particularly within the domain of cardiac electrophysiology, assumes paramount importance for the near future. The escalating environmental constraints encountered necessitate a proactive approach. This position paper aims to raise awareness among physicians, spark critical inquiry and identify potential solutions to enhance the sustainability of our practice. Reprocessing of single-use medical devices has emerged as a potential solution to mitigate the environmental impact of electrophysiology procedures, while also offering economic advantages. However, reprocessing remains unauthorized in certain countries. In regions where it is possible, stringent regulatory standards must be adhered to, to ensure patient safety. It is essential that healthcare professionals, policymakers and manufacturers collaborate to drive innovation, explore sustainable practices and ensure that patient care remains uncompromised in the face of environmental challenges. Ambitious national/international programmes of disease prevention should be the cornerstone of the strategy. It is equally vital to implement immediate actions, as delineated in this position paper, to bring about tangible change quickly.


Assuntos
Cardiologia , Desfibriladores Implantáveis , Marca-Passo Artificial , Humanos , Arritmias Cardíacas/terapia , Sociedades Médicas
17.
Mayo Clin Proc ; 99(5): 754-765, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38180394

RESUMO

OBJECTIVE: To compare outcomes after left atrial appendage occlusion (LAAO) via implanted device vs no LAAO in a matched cohort of patients with atrial fibrillation (AF). METHODS: This longitudinal retrospective cohort study was based on the national database covering hospital care for the entire French population. Adults (≥18 years of age) who had been hospitalized with AF (January 1, 2015, to January 1, 2020) who underwent LAAO were identified. Propensity score matching was used to control for potential confounders of the treatment-outcome relationship. The primary outcome was a composite of ischemic stroke, major bleeding, or all-cause death during follow-up. RESULTS: After propensity score matching, 1216 patients with AF who were treated with LAAO were matched with 1216 controls (patients AF who were not treated with LAAO). Mean follow-up was 14.5 months (median, 13 months; IQR, 7-21 months). Patients with LAAO had a lower risk of the composite outcome (HR, 0.48; 95% CI, 0.42 to 0.55). Total events (309 for LAAO vs 640 for controls) and event rates (23.3% vs 44.0%/year, respectively) were lower for LAAO, driven primarily by a decreased risk of all-cause death (HR, 0.39; 95% CI, 0.33 to 0.46; P<.0001), whereas ischemic stroke risk was higher (HR, 1.75; 95% CI, 1.17 to 2.64). Significant interactions were observed in subgroups with a history of ischemic stroke (P<.001) and of bleeding (P=.002). CONCLUSION: Among AF patients at high bleeding risk, our nationwide study highlights a high risk of clinical events during follow-up. LAAO appeared less effective than no LAAO in preventing stroke but more effective in preventing death. Left atrial appendage occlusion is particularly effective in patients with previous ischemic stroke or any episode of bleeding.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Humanos , Fibrilação Atrial/cirurgia , Apêndice Atrial/cirurgia , Masculino , Feminino , Idoso , Estudos Retrospectivos , Pontuação de Propensão , Estudos Longitudinais , Pessoa de Meia-Idade , Resultado do Tratamento , Dispositivo para Oclusão Septal , AVC Isquêmico/prevenção & controle , AVC Isquêmico/etiologia , AVC Isquêmico/epidemiologia , Idoso de 80 Anos ou mais , França/epidemiologia
18.
ESC Heart Fail ; 11(2): 1228-1235, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38234123

RESUMO

AIMS: Heart failure (HF) is a chronic disease affecting 64 million people worldwide and places a severe burden on society because of its mortality, numerous re-hospitalizations and associated costs. HeartLogic™ is an algorithm programmed into implanted devices incorporating several biometric parameters which aims to predict HF episodes. It provides an index which can be monitored remotely, allowing pre-emptive treatment of congestion to prevent acute decompensation. We aim to assess the impact and security of pre-emptive HF management, guided by the HeartLogic™ index. METHODS AND RESULTS: The HeartLogic™ France Cohort Study is an investigator-initiated, prospective, multi-centre, non-randomized study. Three hundred ten patients with a history of HF (left ventricular ejection fraction ≤40%; or at least one episode of clinical HF with elevated NT-proBNP ≥450 ng/L) and implanted with a cardioverter defibrillator enabling HeartLogic™ index calculation will be included across 10 French centres. The HeartLogic™ index will be monitored remotely for 12 months and in the event of a HeartLogic™ index ≥16, the local investigator will contact the patient for assessment and adjust HF treatment as necessary. The primary endpoint is unscheduled hospitalization for HF. Secondary endpoints are all-cause mortality, cardiovascular death, HF-related death, unscheduled hospitalizations for ventricular or atrial arrhythmia and HeartLogic™ index evolution over time. Blood samples will be collected for biobanking, and quality of life will be assessed. Finally, the safety of a HeartLogic™-triggered strategy for initiating or increasing diuretic therapy will be assessed. A blind and independent committee will adjudicate the events. CONCLUSIONS: The HeartLogic™ France Cohort Study will provide robust real-world data in a cohort of HF patients managed with the HeartLogic™ algorithm allowing pre-emptive treatment of heart failure exacerbations.


Assuntos
Insuficiência Cardíaca , Qualidade de Vida , Humanos , Estudos de Coortes , Volume Sistólico , Estudos Prospectivos , Bancos de Espécimes Biológicos , Função Ventricular Esquerda , Algoritmos
19.
Heart ; 110(4): 245-253, 2024 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-37813560

RESUMO

OBJECTIVE: Left atrial appendage closure (LAAC) is recommended to decrease the stroke risk in patients with atrial fibrillation and contraindications to anticoagulation. However, age-stratified data are scarce. The aim of this study was to provide information on the safety and efficacy of LAAC, with emphasis on the oldest patients. METHODS: A nationwide, prospective, multicentre, observational registry was established by 53 French cardiology centres in 2018-2021. The composite primary endpoint included ischaemic stroke, systemic embolism, and unexplained or cardiovascular death. Separate analyses were done in the groups <80 years and ≥80 years. RESULTS: Among the 1053 patients included, median age was 79.7 (73.6-84.3) years; 512 patients (48.6%) were aged ≥80 years. Procedure-related serious adverse events were non-significantly more common in octogenarians (7.0% vs 4.4% in patients aged <80 years, respectively; p=0.07). Despite a higher mean CHA2DS2-VASc score in octogenarians, the rate of thromboembolic events during the study was similar in both groups (3.0 vs 3.1/100 patient-years; p=0.85). By contrast, all-cause mortality was significantly higher in octogenarians (15.3 vs 10.1/100 patient-years, p<0.015), due to a higher rate of non-cardiovascular deaths (8.2 vs 4.9/100 patient-years, p=0.034). The rate of the primary endpoint was 8.1/100 patient-years overall with no statistically significant difference between age groups (9.4 and 7.0/100 patient-years; p=0.19). CONCLUSION: Despite a higher mean CHA2DS2-VASc score in octogenarians, the rate of thromboembolic events after LAAC in this age group was similar to that in patients aged <80 years. TRIAL REGISTRATION NUMBER: ClinicalTrials.gov Registry (NCT03434015).


Assuntos
Apêndice Atrial , Fibrilação Atrial , Isquemia Encefálica , Acidente Vascular Cerebral , Tromboembolia , Idoso , Idoso de 80 Anos ou mais , Humanos , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Oclusão do Apêndice Atrial Esquerdo , Resultado do Tratamento , Estudos Prospectivos , Isquemia Encefálica/complicações , Fibrilação Atrial/complicações , Fibrilação Atrial/cirurgia , Tromboembolia/epidemiologia , Tromboembolia/etiologia , Tromboembolia/prevenção & controle , Apêndice Atrial/cirurgia , Sistema de Registros , Anticoagulantes
20.
Heart Rhythm ; 21(3): 313-320, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37956775

RESUMO

BACKGROUND: The efficacy of beta-blocker treatment in type 3 long QT syndrome (LQT3) remains debated. OBJECTIVES: The purpose of this study was to test the hypothesis that beta-blocker use is associated with cardiac events (CEs) in a French cohort of LQT3 patients. METHODS: All patients with a likely pathogenic/pathogenic variant in the SCN5A gene (linked to LQT3) were included and followed-up. Documented ventricular tachycardia/ventricular fibrillation, torsades de pointes, aborted cardiac arrest, sudden death, and appropriate shocks were considered as severe cardiac events (SCEs). CEs also included syncope. RESULTS: We included 147 patients from 54 families carrying 23 variants. Six of the patients developed symptoms before the age of 1 year and were analyzed separately. The 141 remaining patients (52.5% male; median age at diagnosis 24.0 years) were followed-up for a median of 11 years. The probabilities of a CE and an SCE from birth to the age of 40 were 20.5% and 9.9%, respectively. QTc prolongation (hazard ratio [HR] 1.12 [1.0-1.2]; P = .005]) and proband status (HR 4.07 [1.9-8.9]; P <.001) were independently associated with the occurrence of CEs. Proband status (HR 8.13 [1.7-38.8]; P = .009) was found to be independently associated with SCEs, whereas QTc prolongation (HR 1.11 [1.0-1.3]; P = .108) did not reach statistical significance. The cumulative probability of the age at first CE/SCE was not lower in patients treated with a beta-blocker. CONCLUSION: In agreement with the literature, proband status and lengthened QTc were associated with a higher risk of CEs. Our data do not show a protective effect of beta-blocker treatment.


Assuntos
Parada Cardíaca , Síndrome do QT Longo , Humanos , Masculino , Adulto Jovem , Adulto , Feminino , Eletrocardiografia , Síndrome do QT Longo/tratamento farmacológico , Síndrome do QT Longo/genética , Síndrome do QT Longo/diagnóstico , Síncope , Parada Cardíaca/complicações , Antagonistas Adrenérgicos beta/uso terapêutico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA