Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
PLoS One ; 19(1): e0296780, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38215081

RESUMO

Intracranial pressure measurement is frequently used for diagnosis in neurocritical care but cannot always accurately predict neurological deterioration. Intracranial compliance plays a significant role in maintaining cerebral blood flow, cerebral perfusion pressure, and intracranial pressure. This study's objective was to investigate the feasibility of transferring external pressure into the eye orbit in a large-animal model while maintaining a clinically acceptable pressure gradient between intraorbital and external pressures. The experimental system comprised a specifically designed pressure applicator that can be placed and tightly fastened onto the eye. A pressure chamber made from thin, elastic, non-allergenic film was attached to the lower part of the applicator and placed in contact with the eyelid and surrounding tissues of piglets' eyeballs. External pressure was increased from 0 to 20 mmHg with steps of 1 mmHg, from 20 to 30 mmHg with steps of 2 mmHg, and from 30 to 50 mmHg with steps of 5 mmHg. An invasive pressure sensor was used to measure intraorbital pressure directly. An equation was derived from measured intraorbital and external pressures (intraorbital pressure = 0.82 × external pressure + 3.12) and demonstrated that external pressure can be linearly transferred to orbit tissues with a bias (systematic error) of 3.12 mmHg. This is close to the initial intraorbital pressure within the range of pressures tested. We determined the relationship between intraorbital compliance and externally applied pressure. Our findings indicate that intraorbital compliance can be controlled across a wide range of 1.55 to 0.15 ml/mmHg. We observed that external pressure transfer into the orbit can be achieved while maintaining a clinically acceptable pressure gradient between intraorbital and external pressures.


Assuntos
Olho , Órbita , Animais , Suínos , Projetos Piloto
2.
Sci Rep ; 12(1): 17724, 2022 10 22.
Artigo em Inglês | MEDLINE | ID: mdl-36272984

RESUMO

Optimal cerebral perfusion pressure (CPPopt)-targeted treatment of traumatic brain injury (TBI) patients requires 2-8 h multi-modal monitoring data accumulation to identify CPPopt value for individual patient. Minimizing the time required for monitoring data accumulation is needed to improve the efficacy of CPPopt-targeted therapy. A retrospective analysis of multimodal physiological monitoring data from 87 severe TBI patients was performed by separately representing cerebrovascular autoregulation (CA) indices in relation to CPP, arterial blood pressure (ABP), and intracranial pressure (ICP) to improve the existing CPPopt identification algorithms. Machine learning (ML)-based algorithms were developed for automatic identification of informative data segments that were used for reliable CPPopt, ABPopt, ICPopt and the lower/upper limits of CA (LLCA/ULCA) identification. The reference datasets of the informative data segments and, artifact-distorted segments, and the datasets of different clinical situations were used for training the ML-based algorithms, allowing us to choose the appropriate individualized CPP-, ABP- or ICP-guided management for 79% of the full monitoring time for the studied population. The developed ML-based algorithms allow us to recognize informative physiological ABP/ICP variations within 24 min intervals with an accuracy up to 79% (compared to the initial accuracy of 74%) and use these segments for timely optimal value identification or CA limits determination in CPP, ABP or ICP data. Prospective clinical studies are needed to prove the efficiency of the developed algorithms.


Assuntos
Lesões Encefálicas Traumáticas , Pressão Intracraniana , Humanos , Estudos Retrospectivos , Estudos Prospectivos , Estudos de Viabilidade , Pressão Intracraniana/fisiologia , Circulação Cerebrovascular/fisiologia , Monitorização Fisiológica , Pressão Sanguínea/fisiologia
3.
Transl Vis Sci Technol ; 11(2): 17, 2022 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-35138342

RESUMO

PURPOSE: To analyze the cerebrovascular autoregulation (CA) dynamics in patients with normal-tension glaucoma (NTG) and high-tension glaucoma (HTG) as well as healthy subjects using noninvasive ultrasound technologies for the first time. METHODS: The CA status of 10 patients with NTG, 8 patients with HTG, and 10 healthy subjects was assessed, using an innovative noninvasive ultrasonic technique, based on intracranial blood volume slow-wave measurements. Identified in each participant were intraocular pressure, ocular perfusion pressure, and CA-related parameter volumetric reactivity index (VRx), as well as the duration and doses of the longest cerebral autoregulation impairment (LCAI). In addition, we calculated the associations of these parameters with patients' diagnoses. RESULTS: The VRx value, the LCAI dose, and duration in healthy subjects were significantly lower than in patients with NTG (P < 0.05). However, no significant differences were noted in these parameters between healthy subjects and HTG and between NTG and HTG groups. CONCLUSIONS: NTG is associated with the disturbed cerebral blood flow and could be diagnosed by performing noninvasive CA assessments. TRANSLATIONAL RELEVANCE: The VRx monitoring method can be applied to a wider range of patient groups, especially patients with normal-tension glaucoma.


Assuntos
Glaucoma de Ângulo Aberto , Glaucoma , Glaucoma de Baixa Tensão , Glaucoma de Ângulo Aberto/diagnóstico por imagem , Voluntários Saudáveis , Homeostase , Humanos , Glaucoma de Baixa Tensão/diagnóstico por imagem , Estudos Prospectivos
4.
Medicina (Kaunas) ; 57(3)2021 Mar 03.
Artigo em Inglês | MEDLINE | ID: mdl-33802375

RESUMO

Ventriculoperitoneal shunt placement is the most commonly used treatment of normal-pressure hydrocephalus (NPH). It has been hypothesized that normal-tension glaucoma (NTG) is caused by the treatment of NPH by using the shunt to reduce intracranial pressure (ICP). The aim of this study is to review the literature published regarding this hypothesis and to emphasize the need for neuro-ophthalmic follow-up for the concerned patients. The source literature was selected from the results of an online PubMed search, using the keywords "hydrocephalus glaucoma" and "normal-tension glaucoma shunt". One prospective study on adults, one prospective study on children, two retrospective studies on adults and children, two case reports, three review papers including medical hypotheses, and one prospective study on monkeys were identified. Hypothesis about the association between the treatment of NPH using the shunt to reduce ICP and the development of NTG were supported in all reviewed papers. This suggests that a safe lower limit of ICP for neurological patients, especially shunt-treated NPH patients, should be kept. Thus, we proposed to modify the paradigm of safe upper ICP threshold recommended in neurosurgery and neurology into the paradigm of safe ICP corridor applicable in neurology and ophthalmology, especially for shunt-treated hydrocephalic and glaucoma patients.


Assuntos
Glaucoma , Hidrocefalia de Pressão Normal , Adulto , Humanos , Hidrocefalia de Pressão Normal/cirurgia , Pressão Intracraniana , Estudos Prospectivos , Estudos Retrospectivos , Derivação Ventriculoperitoneal
5.
Sci Rep ; 11(1): 4736, 2021 02 26.
Artigo em Inglês | MEDLINE | ID: mdl-33637806

RESUMO

Intracranial pressure (ICP) monitoring is important in managing neurosurgical, neurological, and ophthalmological patients with open-angle glaucoma. Non-invasive two-depth transcranial Doppler (TCD) technique is used in a novel method for ICP snapshot measurement that has been previously investigated prospectively, and the results showed clinically acceptable accuracy and precision. The aim of this study was to investigate possibility of using the ophthalmic artery (OA) as a pressure sensor for continuous ICP monitoring. First, numerical modeling was done to investigate the possibility, and then a pilot clinical study was conducted to compare two-depth TCD-based non-invasive ICP monitoring data with readings from an invasive Codman ICP microsensor from patients with severe traumatic brain injury. The numerical modeling showed that the systematic error of non-invasive ICP monitoring was < 1.0 mmHg after eliminating the intraorbital and blood pressure gradient. In a clinical study, a total of 1928 paired data points were collected, and the extreme data points of measured differences between invasive and non-invasive ICP were - 3.94 and 4.68 mmHg (95% CI - 2.55 to 2.72). The total mean and SD were 0.086 ± 1.34 mmHg, and the correlation coefficient was 0.94. The results show that the OA can be used as a linear natural pressure sensor and that it could potentially be possible to monitor the ICP for up to 1 h without recalibration.


Assuntos
Lesões Encefálicas Traumáticas/diagnóstico por imagem , Pressão Intracraniana , Artéria Oftálmica/diagnóstico por imagem , Ultrassonografia Doppler Transcraniana/métodos , Adulto , Velocidade do Fluxo Sanguíneo , Lesões Encefálicas Traumáticas/fisiopatologia , Feminino , Humanos , Masculino , Modelos Teóricos , Monitorização Fisiológica/métodos , Projetos Piloto
6.
Medicina (Kaunas) ; 56(12)2020 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-33266148

RESUMO

Background and Objective: Glaucoma is a progressive optic neuropathy in which the optic nerve is damaged. The optic nerve is exposed not only to intraocular pressure (IOP) in the eye, but also to intracranial pressure (ICP), as it is surrounded by cerebrospinal fluid in the subarachnoid space. Here, we analyse ICP differences between patients with glaucoma and healthy subjects (HSs). Materials and Methods: Ninety-five patients with normal-tension glaucoma (NTG), 60 patients with high-tension glaucoma (HTG), and 62 HSs were included in the prospective clinical study, and ICP was measured non-invasively by two-depth transcranial Doppler (TCD). Results: The mean ICP of NTG patients (9.42 ± 2.83 mmHg) was significantly lower than that of HSs (10.73 ± 2.16 mmHg) (p = 0.007). The mean ICP of HTG patients (8.11 ± 2.68 mmHg) was significantly lower than that of NTG patients (9.42 ± 2.83 mmHg) (p = 0.008) and significantly lower than that of HSs (10.73 ± 2.16 mmHg) (p < 0.001). Conclusions: An abnormal ICP value could be one of the many influential factors in the optic nerve degeneration of NTG patients and should be considered as such instead of just being regarded as a "low ICP".


Assuntos
Glaucoma de Ângulo Aberto , Glaucoma de Baixa Tensão , Glaucoma de Ângulo Aberto/diagnóstico , Voluntários Saudáveis , Humanos , Pressão Intracraniana , Pressão Intraocular , Estudos Prospectivos
7.
Brain Sci ; 10(4)2020 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-32244750

RESUMO

This is a comparative study of two novel noninvasive cerebrovascular autoregulation (CA) monitoring methods based on intracranial blood volume (IBV) changes in the human brain. We investigated the clinical applicability of the new volumetric reactivity index (VRx2), reflected by intracranial ultrasonic attenuation dynamics for noninvasive CA monitoring. The CA was determined noninvasively on 43 healthy participants by calculating the volumetric reactivity index (VRx1 from time-of-flight of ultrasound, VRx2 from attenuation of ultrasound). The VRx was calculated as a moving correlation coefficient between the arterial blood pressure and noninvasively measured IBV slow waves. Linear regression between VRx1 and VRx2 (averaged per participants) showed a significant correlation (r = 0.731, p < 0.0001, 95% confidence interval [0.501-0.895]) in data filtered by bandpass filtering. On the other hand, FIR filtering demonstrated a slightly better correlation (r = 0.769, p < 0.0001, 95% confidence interval [0.611-0.909]). The standard deviation of the difference by bandpass filtering was 0.1647 and bias -0.3444; and by FIR filtering 0.1382 and bias -0.3669. This comparative study showed a significant coincidence of the VRx2 index compared to that of VRx1. Hence, VRx2 could be used as an alternative, cost-effective noninvasive cerebrovascular autoregulation index in the same way as VRx1 values are used.

8.
PLoS One ; 13(4): e0196155, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29672564

RESUMO

PURPOSE: This study aimed to examine the incidence of the oculocardiac reflex during a non-invasive intracranial pressure measurement when gradual external pressure was applied to the orbital tissues and eye. METHODS: Patients (n = 101) and healthy volunteers (n = 56) aged 20-75 years who underwent a non-invasive intracranial pressure measurement were included in this retrospective oculocardiac reflex analysis. Prespecified thresholds greater than a 10% or 20% decrease in the heart rate from baseline were used to determine the incidence of the oculocardiac reflex. RESULTS: None of the subjects had a greater than 20% decrease in heart rate from baseline. Four subjects had a greater than 10% decrease in heart rate from baseline, representing 0.9% of the total pressure steps. Three of these subjects were healthy volunteers, and one was a glaucoma patient. CONCLUSION: The incidence of the oculocardiac reflex during a non-invasive intracranial pressure measurement procedure was very low and not associated with any clinically relevant effects.


Assuntos
Técnicas e Procedimentos Diagnósticos , Pressão Intracraniana , Modelos Estatísticos , Reflexo Oculocardíaco , Adulto , Idoso , Interpretação Estatística de Dados , Técnicas e Procedimentos Diagnósticos/instrumentação , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
9.
Libyan J Med ; 12(1): 1384290, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28982295

RESUMO

The aim of the present study was to locate the ophthalmic artery by using the edge of the internal carotid artery (ICA) as the reference depth to perform a reliable non-invasive intracranial pressure measurement via a multi-depth transcranial Doppler device and to then determine the positions and angles of an ultrasonic transducer (UT) on the closed eyelid in the case of located segments. High tension glaucoma (HTG) patients and healthy volunteers (HVs) undergoing non-invasive intracranial pressure measurement were selected for this prospective study. The depth of the edge of the ICA was identified, followed by a selection of the depths of the IOA and EOA segments. The positions and angles of the UT on the closed eyelid were measured. The mean depth of the identified ICA edge for HTG patients was 64.3 mm and was 63.0 mm for HVs (p = 0.21). The mean depth of the selected IOA segment for HTG patients was 59.2 mm and 59.3 mm for HVs (p = 0.91). The mean depth of the selected EOA segment for HTG patients was 48.5 mm and 49.8 mm for HVs (p = 0.14). The difference in the located depths of the segments between groups was not statistically significant. The results showed a significant difference in the measured UT angles in the case of the identified edge of the ICA and selected ophthalmic artery segments (p = 0.0002). We demonstrated that locating the IOA and EOA segments can be achieved using the edge of the ICA as a reference point. ABBREVIATIONS: OA: ophthalmic artery; IOA: intracranial segments of the ophthalmic artery; EOA: extracranial segments of the ophthalmic artery; ICA: internal carotid artery; UT: ultrasonic transducer; HTG: high tension glaucoma; SD: standard deviation; ICP: intracranial pressure; TCD: transcranial Doppler.


Assuntos
Artéria Carótida Interna/diagnóstico por imagem , Glaucoma/fisiopatologia , Pressão Intracraniana , Artéria Oftálmica/diagnóstico por imagem , Adulto , Estudos de Casos e Controles , Técnicas de Diagnóstico Oftalmológico , Feminino , Humanos , Masculino , Estudos Prospectivos , Reprodutibilidade dos Testes , Ultrassonografia Doppler Transcraniana
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA