Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Eur J Heart Fail ; 26(4): 817-824, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38404257

RESUMO

AIMS: Recent studies have shown that lung ultrasound-assessed pulmonary congestion is worse in heart failure when pulmonary vascular resistance (PVR) is increased, suggesting a paradoxical relationship between right heart failure and increased lung water content. Accordingly, we wondered if lung ultrasound would reveal otherwise clinically silent pulmonary congestion in patients with pulmonary arterial hypertension (PAH). METHODS AND RESULTS: All patients referred for suspicion of PAH in a tertiary centre from January 2020 to December 2022 underwent a complete diagnostic work-up including echocardiography, lung ultrasound and right heart catheterization. Pulmonary congestion was identified by lung ultrasound B-lines using an 8-site scan. The study enrolled 102 patients with idiopathic PAH (mean age 53 ± 13 years; 71% female). World Health Organization functional classes I, II, and III were found in 2%, 52%, and 46% of them, respectively. N-terminal pro-brain natriuretic peptide (NT-proBNP) was 377 pg/ml (interquartile range [IQR] 218-906). B-lines were identified in 77 out of 102 patients (75%), with a median of 3 [IQR 1-5]. At univariable analysis, B-lines were positively correlated with male sex, age, NT-proBNP, systolic pulmonary artery pressure (sPAP), right atrial pressure (RAP), PVR, left ventricular end-diastolic volume and tricuspid annular plane systolic excursion (TAPSE), and negatively with cardiac output and stroke volume. At multivariable analysis, RAP (p < 0.001), TAPSE/sPAP (p = 0.001), and NT-proBNP (p = 0.04) were independent predictors of B-lines. CONCLUSION: Lung ultrasound commonly discloses pulmonary congestion in PAH. This finding is related to right ventricular to pulmonary artery uncoupling, and may tentatively be explained by increased central venous pressure impeding lymphatic outflow.


Assuntos
Cateterismo Cardíaco , Insuficiência Cardíaca , Resistência Vascular , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/etiologia , Cateterismo Cardíaco/métodos , Resistência Vascular/fisiologia , Ecocardiografia/métodos , Hipertensão Arterial Pulmonar/fisiopatologia , Hipertensão Arterial Pulmonar/diagnóstico , Idoso , Pulmão/diagnóstico por imagem , Pulmão/fisiopatologia , Pressão Propulsora Pulmonar/fisiologia , Artéria Pulmonar/fisiopatologia , Artéria Pulmonar/diagnóstico por imagem , Peptídeo Natriurético Encefálico/sangue , Adulto , Fragmentos de Peptídeos
2.
J Am Soc Echocardiogr ; 36(11): 1181-1189, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37544385

RESUMO

OBJECTIVES: The differential diagnosis between pulmonary arterial hypertension (PAH) and postcapillary pulmonary hypertension (PH) in heart failure with preserved ejection fraction (HFpEF) is sometimes difficult despite guidelines-derived standardized step-by-step diagnostic algorithms. We therefore explored the added value of lung ultrasound to a previously validated echocardiographic score of right heart catheterization measurements. METHODS: Patients referred for PH underwent a right heart catheterization, echocardiography, and lung ultrasound before and after rapid infusion of 7 mL/kg of saline. A 7-point echocardiographic score based on cardiac chamber dimensions and estimates of filling pressures was implemented for the prediction of precapillary PH. Pulmonary congestion was identified by lung ultrasound B lines. RESULTS: The study enrolled 70 patients with PAH and 77 patients with HFpEF. The PAH patients had a higher echocardiographic score (3.5 ± 1.8 vs 1.6 ± 1.5; P < .001). The HFpEF patients had more B lines both before (8.1 ± 4.2 vs 5.1 ± 3.0; P < .001) and after fluid challenge (14.6 ± 5.4 vs 7.6 ± 3.5; P < .001) and a more important increase (Δ) of B lines after fluid challenge (6.5 ± 2.9 vs 2.5 ± 1.6; P < .001). The sensitivity and specificity of the echocardiographic score (cutoff ≥2) alone for PAH were 0.91 and 0.49, respectively (area under the curve of 0.78). The best diagnostic improvement was observed with addition of ΔB lines + E/e' post-fluid challenge to the echocardiographic score, with a significant increase of the area under the curve (0.98) and (with a cutoff given by the presence of echo score ≥2, ΔB lines <4 and E/e' post < 11) a sensitivity of 0.90 (95% CI, 0.83; 0.97) and specificity of 0.84 (95% CI, 0.76; 0.93). CONCLUSIONS: Lung ultrasound combined with echocardiography at baseline and after fluid challenge has an incremental value for the differential diagnosis between PAH and PH-HFpEF.


Assuntos
Insuficiência Cardíaca , Hipertensão Pulmonar , Hipertensão Arterial Pulmonar , Humanos , Hipertensão Pulmonar/diagnóstico por imagem , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/diagnóstico por imagem , Diagnóstico Diferencial , Volume Sistólico , Ecocardiografia/métodos , Pulmão , Hipertensão Arterial Pulmonar/diagnóstico
3.
J Cardiovasc Pharmacol ; 82(3): 196-200, 2023 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-37405837

RESUMO

ABSTRACT: Sodium-glucose cotransporter 2 inhibitors (SGLT2-i) are a novel class of oral hypoglycemic agents currently used among patients with type 2 diabetes mellitus (T2DM). The effects of SGLT2-i inhibitors on cardiac structure and function are not fully understood. The aim of this study is to evaluate the echocardiographic changing among patients with well-controlled T2DM treated with SGLT2-i in real-world setting. Thirty-five well-controlled T2DM patients (65 ± 9 years, 43.7% male) with preserved left ventricular ejection fraction (LVEF) and 35 age and sex-matched controls were included. T2DM patients underwent clinical and laboratory evaluation; 12-lead surface electrocardiogram; 2-dimensional color Doppler echocardiography at enrolment, before SGLT2-i administration, and at 6 months follow-up after an uninterrupted 10 mg once daily of empagliflozin (n: 21) or dapagliflozin (n: 14). Standard echocardiographic measurements, LV global longitudinal strain (LV-GLS), global wasted work, and global work efficiency were calculated. T2DM patients showed higher E\E' ratio (8.3 ± 2.5 vs. 6.3 ± 0.9; P < 0.0001 ) and lower LV-GLS (15.8 ± 8.1 vs. 22.1 ± 1.4%; P < 0.0001 ) and global myocardial work efficiency (91 ± 4 vs. 94 ± 3%; P: 0.0007 ) compared with age and sex-matched controls. At 6-month follow-up, T2DM patients showed a significant increase in LVEF (58.9 ± 3.2 vs. 62 ± 3.2; P < 0.0001 ), LV-GLS (16.2 ± 2.8 vs. 18.7 ± 2.4%; P = 0.003 ), and global work efficiency (90.3 ± 3.5 vs. 93.3 ± 3.2%; P = 0.0004 ) values; conversely, global wasted work values (161.2 ± 33.6 vs. 112.72 ± 37.3 mm Hg%; P < 0.0001 ) significantly decreased. Well-controlled T2DM patients with preserved LVEF who are treated with a SGLT2-i on top of the guidelines direct medical therapy showed a favorable cardiac remodeling, characterized by the improvement of LV-GLS and myocardial work efficiency.


Assuntos
Diabetes Mellitus Tipo 2 , Disfunção Ventricular Esquerda , Humanos , Masculino , Feminino , Volume Sistólico , Função Ventricular Esquerda , Diabetes Mellitus Tipo 2/diagnóstico , Diabetes Mellitus Tipo 2/tratamento farmacológico , Transportador 2 de Glucose-Sódio/farmacologia , Transportador 2 de Glucose-Sódio/uso terapêutico , Deformação Longitudinal Global , Glucose , Sódio
4.
J Clin Med ; 12(3)2023 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-36769702

RESUMO

SARS-CoV-2 (severe acute respiratory syndrome Coronavirus-2) rapidly spread worldwide as COVID-19 (Coronavirus disease 2019), causing a costly and deadly pandemic. Different pulmonary manifestations represent this syndrome's most common clinical manifestations, together with the cardiovascular complications frequently observed in these patients. Ultrasound (US) evaluations of the lungs, heart, and lower limbs may be helpful in the diagnosis, follow-up, and prognosis of patients with COVID-19. Moreover, POCUS (point-of-care ultrasound) protocols are particularly useful for patients admitted to intensive care units. The present review aimed to highlight the clinical conditions during the SARS-CoV-2 pandemic in which the US represents a crucial diagnostic tool.

5.
Artigo em Inglês | MEDLINE | ID: mdl-36767456

RESUMO

Point-of-care ultrasonography (POCUS) represents a goal-directed ultrasound examination performed by clinicians directly involved in patient healthcare. POCUS has been widely used in emergency departments, where US exams allow physicians to make quick diagnoses and to recognize early life-threatening conditions which require prompt interventions. Although initially meant for the real-time evaluation of cardiovascular and respiratory pathologies, its use has been extended to a wide range of clinical applications, such as screening for deep-vein thrombosis and trauma, abdominal ultrasonography of the right upper quadrant and appendix, and guidance for invasive procedures. Moreover, recently, bedside ultrasounds have been used to evaluate the fluid balance and to guide decongestive therapy in acutely decompensated heart failure. The aim of the present review was to discuss the most common applications of POCUS in the emergency setting.


Assuntos
Médicos , Sistemas Automatizados de Assistência Junto ao Leito , Humanos , Ultrassonografia/métodos , Testes Imediatos , Pulmão , Serviço Hospitalar de Emergência
6.
Int J Cardiovasc Imaging ; 39(1): 51-60, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36598689

RESUMO

AIM: To analyze left ventricular (LV) mechanics through advanced echocardiography, including speckle tracking analysis and myocardial work (MW) in a cohort of adults with repaired aortic coarctation (CoA). METHODS: Data on standard echocardiography, LV speckle-tracking and MW analysis were collected in CoA patients > 18 years with no significant recoartation or valvular disease and normal LV ejection fraction at the time of the exam. MW indices were calculated using the blood pressure measured in the right arm. A group of healthy subjects with comparable sex, age and body surface area was included for comparison. RESULTS: Eighty-nine CoA patients and 70 healthy subjects were included. Patients had higher systolic blood pressure (p < 0.0001), LV mass index (p < 0.0001), left atrial volume index (p = 0.005) and E/E' ratio (p = 0.001). Despite similar LV ejection fraction, speckle tracking analysis revealed lower global longitudinal strain (GLS: - 18.3[17-19] vs - 20.7[19-22]%, p < 0.0001) and increased peak systolic dispersion (PSD: 45[40-54] vs 37.5[32-43] ms, p < 0.0001) in CoA patients. Global work index (GWI) and global constructive work were similar to healthy controls (p = 0.6 and 0.5, respectively), whereas CoA patients showed significant increased wasted work (GWW: 125[90-185] vs 89.5[64-127]mmHg%, p < 0.0001) and a mild but significant reduction in global work efficiency (GWE: 93%[92-95] vs 95%[94-97], p < 0.0001). Moreover, when stratifying for GLS values, MW analysis showed increased GWW and PSD with impaired GWE in 54(61%) patients with normal GLS compared to healthy individuals. Spearman's linear method illustrated an inverse relation between GWE and PSD (r: - 0.53, p < 0.0001), while GCW was associated with peak (r: 0.2, p = 0.01) and mean gradient across the descending aorta (r: 0.3, p = 0.004) and with systolic blood pressure (r: 0.48, p < 0.0001). PSD was the sole univariate predictor of GWE on linear regression analysis (ß: - 0.1 [- 0.16 to - 0.07], p < 0.0001), whereas female sex, SBP and gradients across the descending aorta were independently associated with higher GCW values. When CoA patients were divided based on the history of redo CoA repair and arterial hypertension, no significant differences in MW indices were found. CONCLUSIONS: MW is a novel echocardiographic tool, which provides additional information on LV performance in CoA patients over GLS allowing a more comprehensive understanding of LV dysfunction mechanisms in a setting of increased afterload.


Assuntos
Coartação Aórtica , Humanos , Adulto , Feminino , Coartação Aórtica/diagnóstico por imagem , Coartação Aórtica/cirurgia , Coartação Aórtica/complicações , Valor Preditivo dos Testes , Ecocardiografia/métodos , Função Ventricular Esquerda/fisiologia , Volume Sistólico/fisiologia
7.
J Clin Med ; 11(14)2022 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-35887765

RESUMO

Percutaneous patent foramen ovale (PFO) closure by traditional, double disc occluder devices was shown to be safe for patients with PFO, and more effective than prolonged medical therapy in preventing recurrent thromboembolic events. The novel suture-mediated "deviceless" PFO closure system overcomes most of the risks and limitations associated with the traditional PFO occluders, appearing to be feasible in most interatrial septum anatomies, even if data about its long-term effectiveness and safety are still lacking. The aim of the present review was to provide to the reader the state of the art about the traditional and newer techniques of PFO closure, focusing both on the procedural aspects and on the pivotal role of transesophageal echocardiography (TEE) in patient's selection, peri-procedural guidance, and post-interventional follow-up.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA