Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 204
Filtrar
2.
Europace ; 26(5)2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38743765

RESUMO

Imaging using cardiac computed tomography (CT) or magnetic resonance (MR) imaging has become an important option for anatomic and substrate delineation in complex atrial fibrillation (AF) and ventricular tachycardia (VT) ablation procedures. Computed tomography more common than MR has been used to detect procedure-associated complications such as oesophageal, cerebral, and vascular injury. This clinical consensus statement summarizes the current knowledge of CT and MR to facilitate electrophysiological procedures, the current value of real-time integration of imaging-derived anatomy, and substrate information during the procedure and the current role of CT and MR in diagnosing relevant procedure-related complications. Practical advice on potential advantages of one imaging modality over the other is discussed for patients with implanted cardiac rhythm devices as well as for planning, intraprocedural integration, and post-interventional management in AF and VT ablation patients. Establishing a team of electrophysiologists and cardiac imaging specialists working on specific details of imaging for complex ablation procedures is key. Cardiac magnetic resonance (CMR) can safely be performed in most patients with implanted active cardiac devices. Standard procedures for pre- and post-scanning management of the device and potential CMR-associated device malfunctions need to be in place. In VT patients, imaging-specifically MR-may help to determine scar location and mural distribution in patients with ischaemic and non-ischaemic cardiomyopathy beyond evaluating the underlying structural heart disease. Future directions in imaging may include the ability to register multiple imaging modalities and novel high-resolution modalities, but also refinements of imaging-guided ablation strategies are expected.


Assuntos
Consenso , Imageamento por Ressonância Magnética , Tomografia Computadorizada por Raios X , Humanos , Ablação por Cateter , Técnicas Eletrofisiológicas Cardíacas , Taquicardia Ventricular/cirurgia , Taquicardia Ventricular/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/fisiopatologia , Valor Preditivo dos Testes , Europa (Continente) , Resultado do Tratamento
4.
Europace ; 26(5)2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38646926

RESUMO

AIMS: Using thermal-based energy sources [radiofrequency (RF) energy/cryo energy] for catheter ablation is considered effective and safe when performing pulmonary vein isolation (PVI) in patients with paroxysmal atrial fibrillation (AF). However, treatment success remains limited and complications can occur due to the propagation of thermal energy into non-target tissues. We aim to compare pulsed field ablation (PFA) with RF ablation in terms of efficacy and safety for patients with drug-resistant paroxysmal AF. METHODS AND RESULTS: The BEAT PAROX-AF trial is a European multicentre, superiority, open-label randomized clinical trial in two parallel groups. A total of 292 participants were recruited in 9 high-volume European clinical centres in 5 countries. Patients with paroxysmal AF were randomized to PFA (FARAPULSE Endocardial Ablation System©, Boston Scientific) or RF using the CLOSE protocol with contact force sensing catheter (SmartTouch© catheter and CARTO© Biosense Webster). The primary endpoint will be the 1-year recurrence of atrial arrhythmia, and the major secondary safety endpoint will be the occurrence of acute (<7 days) procedure-related serious adverse events, or pulmonary vein stenosis, or atrio-oesophageal fistula up to 12 months. Additionally, five sub-studies investigate the effect of PFA on oesophageal safety, cerebral lesions, cardiac autonomic nervous system, durability of PVI as assessed during redo ablation procedures, and atrial and ventricular function. The study began on 27 December 2021 and concluded recruitment on 17 January 2024. Results will be available in mid-2025. CONCLUSION: The BEAT PAROX-AF trial aims to provide critical insights into the optimal treatment approach for patients with paroxysmal AF.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Ablação por Cateter/métodos , Resultado do Tratamento , Veias Pulmonares/cirurgia , Feminino , Masculino , Recidiva , Europa (Continente) , Pessoa de Meia-Idade
5.
Europace ; 26(4)2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38584423

RESUMO

Electrical storm (ES) is a state of electrical instability, manifesting as recurrent ventricular arrhythmias (VAs) over a short period of time (three or more episodes of sustained VA within 24 h, separated by at least 5 min, requiring termination by an intervention). The clinical presentation can vary, but ES is usually a cardiac emergency. Electrical storm mainly affects patients with structural or primary electrical heart disease, often with an implantable cardioverter-defibrillator (ICD). Management of ES requires a multi-faceted approach and the involvement of multi-disciplinary teams, but despite advanced treatment and often invasive procedures, it is associated with high morbidity and mortality. With an ageing population, longer survival of heart failure patients, and an increasing number of patients with ICD, the incidence of ES is expected to increase. This European Heart Rhythm Association clinical consensus statement focuses on pathophysiology, clinical presentation, diagnostic evaluation, and acute and long-term management of patients presenting with ES or clustered VA.


Assuntos
Desfibriladores Implantáveis , Insuficiência Cardíaca , Taquicardia Ventricular , Humanos , Fatores de Risco , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia , Incidência , Insuficiência Cardíaca/complicações , Ásia/epidemiologia , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/terapia , Taquicardia Ventricular/complicações
6.
Front Cardiovasc Med ; 11: 1343424, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38322767

RESUMO

Introduction: Implantable cardiac monitors (ICMs) provide long-term arrhythmia monitoring, but high rates of false detections increase the review burden. The new "SmartECG" algorithm filters false detections. Using large real-world data sets, we aimed to quantify the reduction in workload and any loss in sensitivity from this new algorithm. Methods: Patients with a BioMonitor IIIm and any device indication were included from three clinical projects. All subcutaneous ECGs (sECGs) transmitted via remote monitoring were classified by the algorithm as "true" or "false." We quantified the relative reduction in workload assuming "false" sECGs were ignored. The remote monitoring workload from five hospitals with established remote monitoring routines was evaluated. Loss in sensitivity was estimated by testing a sample of 2000 sECGs against a clinical board of three physicians. Results: Of our population of 368 patients, 42% had an indication for syncope or pre-syncope and 31% for cryptogenic stroke. Within 418.5 patient-years of follow-up, 143,096 remote monitoring transmissions contained 61,517 sECGs. SmartECG filtered 42.8% of all sECGs as "false," reducing the number per patient-year from 147 to 84. In five hospitals, nine trained reviewers inspected on average 105 sECGs per working hour. This results in an annual working time per patient of 83 min without SmartECG, and 48 min with SmartECG. The loss of sensitivity is estimated as 2.6%. In the majority of cases where true arrhythmias were rejected, SmartECG classified the same type of arrhythmia as "true" before or within 3 days of the falsely rejected sECG. Conclusion: SmartECG increases efficiency in long-term arrhythmia monitoring using ICMs. The reduction of workload by SmartECG is meaningful and the risk of missing a relevant arrhythmia due to incorrect filtering by the algorithm is limited.

7.
Clin Res Cardiol ; 2024 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-38324039

RESUMO

BACKGROUND: Epicardial ablation has become an integral part of the treatment of ventricular tachycardias (VT). This study reports the safety of epicardial access as well as the efficacy of epicardial ablation of structural heart disease in a tertiary single-center experience. METHODS: Between January 2016 and February 2022, consecutive patients undergoing an epicardial access for VT ablation were included. Different puncture techniques and occurrence of epicardial access-related complications as well as the safety of ablation using non-ionic 5% dextrose in water (D5W) compared to standard 0.9% normal saline (NS) irrigation were analyzed. VT recurrence rates during a mean follow-up of 37 ± 23 months were reported. RESULTS: In total, 197 patients undergoing a total of 239 procedures were included (59.8 ± 15.3 years, 86% males). A total of 154 patients (78%) had non-ischemic cardiomyopathies with a mean LVEF of 37 ± 14. Anterior-oriented epicardial access was aimed for in all cases and was successful in 217 (91%) of all procedures, whereas access was achieved in 19 procedures (8%) only using an inferior oriented access and in three procedures (1%) using surgical access due to severe adhesions or anatomical requirements. Overall epicardial puncture-related complications occurred in 18 (8%) of all procedures with minor pericardial bleeding in nine, pericardial tamponade in one, pneumothorax in five, pneumopericardium in one, and abdominal puncture in two cases. Presence of adhesions could be identified as the only independent predictor of epicardial access-related complications. D5W was used in 79 cases and regular 0.9% saline in 117 procedures. No differences were seen regarding acute ablation success or complications. During follow-up, 47% of all patients were free from any VTs (56% D5W vs. 40% NS; log-rank p = 0.747) and 92% of clinical VTs (98% D5W vs. 91% NS; log-rank p = 0.139). CONCLUSIONS: In this large single-centre experience, epicardial access and ablation were safe and feasible. Although long-term clinical VT recurrence rates were low, overall VT recurrences as well as mortality were high advocating for a highly experienced, interdisciplinary approach including intense management of underlying cardiac disease/heart failure. Routine usage of D5W was safe and associated with comparable short- or long-term clinical or overall VT freedom.

8.
J Clin Med ; 12(22)2023 Nov 19.
Artigo em Inglês | MEDLINE | ID: mdl-38002789

RESUMO

BACKGROUND: Pulmonary vein isolation (PVI) is an effective treatment option for patients with symptomatic atrial fibrillation (AF). However, the electrical recovery of pulmonary veins (PVs) is the main trigger for AF recurrences. This study investigates the characteristics of patients admitted for redo AF ablation, the PV reconnection rates depending on previous ablation modalities and the impact of different ablation strategies for redo procedures. METHODS: Consecutive patients undergoing first redo AF ablation were included. Patients were grouped according to the electrical recovery of at least one PV. The impacts of the technique for first AF ablation on PV reconnection rates and patients with and without PV reconnection were compared. Different ablation strategies for redo procedures were compared and its recurrence rates after a mean follow-up of 25 ± 20 months were investigated. RESULTS: A total of 389 patients (68 ± 10 years; 57% male; 39% paroxysmal AF) underwent a first redo. The median time between the first and redo procedure was 40 ± 39 months. Radiofrequency was used in 278 patients, cryoballoon was used in 85 patients and surgical AF ablation was performed on 26 patients. In total, 325 patients (84%) had at least one PV reconnected, and the mean number of reconnected PVs was 2.0 ± 1.3, with significant differences between ablation approaches (p for all = 0.002); this was mainly due to differences in the left inferior PV and right superior PV reconnections. The presence of PV reconnection during redo was not associated with better long-term success compared to completely isolated PVs (67% vs. 67%; log-rank p = 0.997). Overall, the different ablation strategies for redos were comparable regarding AF recurrences during follow-up (p = 0.079), with the ablation approach having no impact in the case of left atrial low voltage or without. CONCLUSIONS: PV reconnections after initial successful PVI are common among all techniques of AF ablation. Long-term rhythm control off antiarrhythmic drugs was possible in 2/3 of all patients after the redo procedure; however, different ablation strategies with extra-PV trigger ablation did not improve long-term success. Patients with recurrent AF after PVI constitute a challenging group of patients.

9.
Clin Res Cardiol ; 2023 Nov 03.
Artigo em Inglês | MEDLINE | ID: mdl-37921923

RESUMO

BACKGROUND AND OBJECTIVES: Long-term oral anticoagulation (OAC) following successful catheter ablation of atrial fibrillation (AF) remains controversial. Prospective data are missing. The ODIn-AF study aimed to evaluate the effect of OAC on the incidence of silent cerebral embolic events and clinically relevant cardioembolic events in patients at intermediate to high risk for embolic events, free from AF after pulmonary vein isolation (PVI). METHODS: This prospective, randomized, multicenter, open-label, blinded endpoint interventional trial enrolled patients who were scheduled for PVI to treat paroxysmal or persistent AF. Six months after PVI, AF-free patients were randomized to receive either continued OAC with dabigatran or no OAC. The primary endpoint was the incidence of new silent micro- and macro-embolic lesions detected on brain MRI at 12 months of follow-up compared to baseline. Safety analysis included bleedings, clinically evident cardioembolic, and serious adverse events (SAE). RESULTS: Between 2015 and 2021, 200 patients were randomized into 2 study arms (on OAC: n = 99, off OAC: n = 101). There was no significant difference in the occurrence of new cerebral microlesions between the on OAC and off OAC arm [2 (2%) versus 0 (0%); P = 0.1517] after 12 months. MRI showed no new macro-embolic lesion, no clinical apparent strokes were present in both groups. SAE were more frequent in the OAC arm [on OAC n = 34 (31.8%), off OAC n = 18 (19.4%); P = 0.0460]; bleedings did not differ. CONCLUSION: Discontinuation of OAC after successful PVI was not found to be associated with an elevated risk of cerebral embolic events compared with continued OAC after a follow-up of 12 months.

10.
Front Cardiovasc Med ; 10: 1229651, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37645518

RESUMO

Background: Atrial fibrillation (AF) is the most common concomitant disease in patients undergoing transcatheter edge-to-edge repair (TEER) for mitral regurgitation (MR) and detrimentally affects their outcome. While there is increasing evidence for prognostic improvement and safety of catheter ablation (CA) of AF in the overall cohort of heart failure patients, corresponding data in TEER patients are lacking. Objectives: To investigate the impact of treatment regimens for concomitant AF on survival of TEER patients. Methods: In a multicenter observational cohort study consecutive patients successfully undergoing TEER were analyzed and survival of patients receiving CA of concomitant AF was compared with that of patients on pharmacological AF treatment and with that of patients without a history of AF, using propensity score matching (PSM). Results: A total of 821 patients were analyzed. Of these, 608 (74.1%) had concomitant AF, of whom 48 patients received CA. Patients with CA in AF showed significantly higher 3-year-survival after TEER compared to PSM-patients on pharmacological AF treatment (75.5% [36/48] vs. 49.4% [166/336], p = 0.009). The 3-year-survival after TEER of patients with concomitant AF treated with CA was not significantly different from PSM-patients without AF (75.5% [36/48] vs. 68.3% [98/144], p = 0.36). Conclusions: CA of AF is superior to pharmacotherapy as it significantly improves the survival of TEER patients in a PSM analysis. CA even offsets the prognostic disadvantage of coexisting AF in TEER patients. Given the growing evidence of prognostic benefits in the overall cohort of HF patients, our data point out the importance of treating concomitant AF and support CA as an essential part of a holistic management of TEER patients.

11.
J Arrhythm ; 39(3): 250-302, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37324757

RESUMO

Remote monitoring is beneficial for the management of patients with cardiovascular implantable electronic devices by impacting morbidity and mortality. With increasing numbers of patients using remote monitoring, keeping up with higher volume of remote monitoring transmissions creates challenges for device clinic staff. This international multidisciplinary document is intended to guide cardiac electrophysiologists, allied professionals, and hospital administrators in managing remote monitoring clinics. This includes guidance for remote monitoring clinic staffing, appropriate clinic workflows, patient education, and alert management. This expert consensus statement also addresses other topics such as communication of transmission results, use of third-party resources, manufacturer responsibilities, and programming concerns. The goal is to provide evidence-based recommendations impacting all aspects of remote monitoring services. Gaps in current knowledge and guidance for future research directions are also identified.

12.
Heart Rhythm ; 20(9): e92-e144, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37211145

RESUMO

Remote monitoring is beneficial for the management of patients with cardiovascular implantable electronic devices by impacting morbidity and mortality. With increasing numbers of patients using remote monitoring, keeping up with higher volume of remote monitoring transmissions creates challenges for device clinic staff. This international multidisciplinary document is intended to guide cardiac electrophysiologists, allied professionals, and hospital administrators in managing remote monitoring clinics. This includes guidance for remote monitoring clinic staffing, appropriate clinic workflows, patient education, and alert management. This expert consensus statement also addresses other topics such as communication of transmission results, use of third-party resources, manufacturer responsibilities, and programming concerns. The goal is to provide evidence-based recommendations impacting all aspects of remote monitoring services. Gaps in current knowledge and guidance for future research directions are also identified.


Assuntos
Desfibriladores Implantáveis , Tecnologia de Sensoriamento Remoto , Humanos
13.
Europace ; 25(5)2023 05 19.
Artigo em Inglês | MEDLINE | ID: mdl-37208301

RESUMO

Remote monitoring is beneficial for the management of patients with cardiovascular implantable electronic devices by impacting morbidity and mortality. With increasing numbers of patients using remote monitoring, keeping up with higher volume of remote monitoring transmissions creates challenges for device clinic staff. This international multidisciplinary document is intended to guide cardiac electrophysiologists, allied professionals, and hospital administrators in managing remote monitoring clinics. This includes guidance for remote monitoring clinic staffing, appropriate clinic workflows, patient education, and alert management. This expert consensus statement also addresses other topics such as communication of transmission results, use of third-party resources, manufacturer responsibilities, and programming concerns. The goal is to provide evidence-based recommendations impacting all aspects of remote monitoring services. Gaps in current knowledge and guidance for future research directions are also identified.


Assuntos
Monitorização Fisiológica , Telemetria , Humanos
14.
J Clin Med ; 12(7)2023 Apr 06.
Artigo em Inglês | MEDLINE | ID: mdl-37048813

RESUMO

BACKGROUND: Electrical storm (ES) represents a serious heart rhythm disorder. This study investigates the impact of ES on acute ablation success and long-term outcomes after VT ablation compared to non-ES patients. METHODS: In this large single-centre study, patients presenting with ES and undergoing VT ablation from June 2018 to April 2021 were compared to patients undergoing VT ablation due to ventricular tachyarrhythmias but without ES. The primary prognostic outcome was VT recurrence, and secondary endpoints were rehospitalization rates and cardiovascular mortality, all after a median follow-up of 22 months. RESULTS: A total of 311 patients underwent a first VT ablation due to ventricular tachyarrhythmias and were included (63 ± 14 years; 86% male). Of these, 108 presented with ES. In the ES cohort, dilated cardiomyopathy as underlying heart disease was significantly higher (p = 0.008). Major complications were equal across both groups (all p > 0.05). Ablation of the clinical VT was achieved in 94% of all patients (p > 0.05). Noninducibility of any VT was achieved in 91% without ES and in 76% with ES (p = 0.001). Patients with ES revealed increased VT recurrence rates during follow-up (65% vs. 40%; log rank p = 0.001; HR 1.841, 95% CI 1.289-2.628; p = 0.001). Furthermore, ES patients suffered from increased rehospitalization rates (73% vs. 48%; log rank p = 0.001; HR 1.948, 95% CI 1.415-2.682; p = 0.001) and cardiovascular mortality (18% vs. 9%; log rank p = 0.045; HR 1.948, 95% CI 1.004-3.780; p = 0.049). After multivariable adjustment, ES was a strong independent predictor of VT recurrence and rehospitalization rates, but not for mortality. In a propensity score-matched cohort, patients with ES still had a higher risk of VT recurrences and rehospitalizations compared to non-ES patients. CONCLUSIONS: VT ablation in patients with ES is challenging and these patients reveal the highest risk for recurrent VTs, rehospitalization and cardiovascular mortality. These patients need close follow-ups and optimal guideline-directed therapy.

15.
Heart Rhythm O2 ; 4(2): 97-102, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36873314

RESUMO

Background: Insertable cardiac monitors (ICMs) are increasingly used for cardiac rhythm diagnosis with expanding indications. Little has been reported about their use and efficacy. Objective: The study sought to evaluate the clinical utility of a novel ICM (Biotronik BIOMONITOR III) including the time to diagnosis in unselected patients with different ICM indications. Methods: Patients from 2 prospective clinical studies were included to determine the diagnostic yield of the ICM. The primary endpoint was time to clinical diagnosis per implant indication or to the first change in atrial fibrillation (AF) therapy. Results: A total of 632 patients were included with a mean follow-up of 233 ± 168 days. Of 384 patients with (pre)syncope, 34.2% had a diagnosis at 1 year. The most frequent therapy was permanent pacemaker implantation. Of 133 patients with cryptogenic stroke, 16.6% had an AF diagnosis at 1 year, resulting in oral anticoagulation. Of 49 patients with an indication for AF monitoring, 41.0% had a relevant change in AF therapy based on ICM data at 1 year. Of 66 patients with other indications, 35.4% received a rhythm diagnosis at 1 year. Moreover, 6.5% of the cohort had additional diagnoses: 26 of 384 patients with syncope, 8 of 133 patients with cryptogenic stroke, and 7 of 49 patients with AF monitoring. Conclusion: In a large unselected patient population with heterogeneous ICM indications, the primary endpoint of rhythm diagnosis was achieved in ∼1 in 4, and additional clinically relevant findings was achieved in 6.5% of patients at short-term follow-up.

16.
Europace ; 25(4): 1379-1391, 2023 04 15.
Artigo em Inglês | MEDLINE | ID: mdl-36881791

RESUMO

AIMS: Pulmonary vein isolation using radiofrequency ablation is an effective treatment option for patients with symptomatic atrial fibrillation (AF). Application of high power over a short period of time (HPSD) is reported to create more efficient lesions and may prevent collateral thermal oesophageal injury. This study aims to compare efficacy and safety of two different HPSD ablation approaches using different ablation index settings. METHODS AND RESULTS: Consecutive patients undergoing AF ablation with HPSD (50 W; ablation index-guided) using the ThermoCool SmartTouch SF catheter were included. Patients were grouped by ablation protocol: ablation with target ablation index (AI) of 400 on the anterior left atrial wall vs. 300 at the posterior left atrial wall (AI 400/300) or AI 450/350 was performed upon the operator's preference and compared. Peri-procedural parameters and complications were recorded, and incidences of endoscopically detected thermal oesophageal lesions (EDEL) analysed. Recurrence rates after a mean follow-up of 25 ± 7 months and reconnection patterns in patients undergoing redo procedures were investigated. A total of 795 patients (67 ± 10 years; 58% male; 48% paroxysmal AF) underwent a first AF ablation with HPSD (211 in group AI 400/300 and 584 in group 450/350). Median procedure time was 82.9 ± 24.6 min with longer ablation times in patients with target AI 400/300 due to higher intraprocedural reconnection rates, increased box lesions, and additional right atrial isthmus ablations. EDEL rates among target AI 400/300 procedures were significantly lower (3% vs. 7%; P = 0.019). Correspondingly, AI 450/350 was the strongest independent predictor of post-ablation EDEL (OR 4.799, CI 1.427-16.138, P = 0.011). Twelve-month (76% vs. 76%; P = 0.892) and long-term ablation single procedure success (68% vs. 71%; log-rank P = 0.452) after a mean of 25 ± 7 months were comparable among both target AI groups; however, long-term success was significantly higher for paroxysmal AF compared to persistent AF (12 months: 80% vs. 72%; P = 0.010; end of follow-up: 76% vs. 65%; log-rank P = 0.001). One hundred three patients (16%) underwent a redo procedure during follow-up documented comparable pulmonary vein (PV) reconnection among groups. Multivariate predictors of AF recurrence were age, left atrium (LA) size, persistent AF, and extra-PV ablation targets. CONCLUSION: High-power short-duration AF ablation with target AI of 400 for non-posterior wall and 300 for posterior wall lesions resulted in comparable long-term results compared to higher AI (450/350) ablations with significantly lower risk for thermal oesophageal lesions. Older age, larger LA size, persistent AF, and extra-PV ablation targets were identified in a multivariate analysis as independent risk factors for recurrences of atrial arrhythmias.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Masculino , Feminino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/etiologia , Seguimentos , Resultado do Tratamento , Esôfago/cirurgia , Inteligência Artificial , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , Recidiva
17.
JACC Clin Electrophysiol ; 9(6): 790-804, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36951814

RESUMO

BACKGROUND: Data about ventricular tachycardia (VT) ablation in patients with electrical storm (ES) is limited. OBJECTIVES: This study sought to compare the prognostic outcome of patients undergoing VT ablation after ES with and without a septal substrate. METHODS: In this large single-center study, consecutive patients presenting with ES and undergoing VT ablation from June 2018 to April 2021 were included. Patients with septal substrate were compared with patients without septal substrate regarding endpoints of cardiovascular mortality, VT recurrences, recurrences of the clinical VT, and rehospitalization rates. RESULTS: A total of 107 patients undergoing a first VT ablation because of electrical storm (ES) were included (age 65 ± 13 years, 86% male, 45% ischemic cardiomyopathy). Major complications occurred in 11% of all patients with increased postinterventional third-degree atrioventricular blocks among patients with septal substrate (9% vs 0%; P = 0.063). Partial ablation successes were similar (95% with a septal substrate vs 100% without a septal substrate; P = 0.251). Complete ablation success was achieved in 63% with a septal substrate and in 87% without a septal substrate (P = 0.004). After a median 22 months of follow-up, patients with septal substrate died significantly more often from cardiovascular causes (26% vs 7%; log-rank P = 0.018). In univariate analysis cardiovascular mortality for ES patients with septal substrate was 4.1-fold higher (HR: 4.192; CI: 1.194-14.719; P = 0.025). Independent predictors of adverse outcome in multivariable regression analysis were presence of septal substrate (HR: 5.723; P = 0.025) and increased age (HR: 1.104; P = 0.003). Recurrences of any ventricular arrhythmia (67% vs 56%; log rank P = 0.554) and rehospitalization rates (80% vs 66%; log rank P = 0.515) were similar between groups. Recurrences of clinical VT were similar (7% vs 2%; P = 0.252). CONCLUSIONS: Presence of a septal substrate is associated with adverse long-term cardiovascular mortality in patients admitted for VT ablation after ES. Despite decreased acute ablation successes in these patients, VT recurrence rates were similar to those without a septal substrate during follow-up.


Assuntos
Ablação por Cateter , Isquemia Miocárdica , Taquicardia Ventricular , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Feminino , Prognóstico , Isquemia Miocárdica/complicações , Arritmias Cardíacas/etiologia , Ablação por Cateter/efeitos adversos , Recidiva
18.
Eur J Intern Med ; 111: 54-62, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36797118

RESUMO

INTRODUCTION: High-power short-duration ablation (HPSD) is an effective therapy for atrial fibrillation with thermal esophageal injury as a rare but relevant side effect. AIM AND METHODS: In this retrospective single-center analysis we evaluated the incidence and relevance of ablation-induced findings and the prevalence of ablation-independent incidental gastrointestinal findings. For 15 months all patients undergoing ablation were screened by postablation esophagogastroduodenoscopy. Pathological findings were followed up and treated if necessary. RESULTS: 286 consecutive patients (66±10 years; 54.9% male) were included. 19.6% of patients showed ablation-associated alterations (10.8% esophageal lesions, 10.8% gastroparesis, 1.7% both findings). Logistic multivariable regression analysis confirmed an influence of lower BMI on the occurrence of RFA-associated endoscopic findings (OR 0.936, 95% CI 0.878-0.997, p<0.05). 48.3% of patients demonstrated incidental gastrointestinal findings. In 1.0% neoplastic lesions were present, 9.4% showed precancerous lesions and in 4.2% neoplastic lesions of unknown dignity were found requiring further diagnostics or therapy. 18.1% of patients demonstrated findings associated with a potentially increased risk of bleeding under anticoagulation. Patients with clinically relevant incidental findings were significantly more often male, 68.8% vs. 49.5% (p<0.01). CONCLUSION: HPSD ablation is safe, no devasting complication occurred in any patient. It resulted in 19.6% ablation-induced thermal injury whereas incidental findings of the upper GI tract were found in 48.3% of patients. Due to the high prevalence of 14.7% of findings requiring further diagnostics, therapy, or surveillance in a cohort that is mimicking the general population, screening endoscopy of the upper GI tract seems to be reasonable in the general population.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Masculino , Feminino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Estudos Retrospectivos , Prevalência , Esôfago/patologia , Endoscopia Gastrointestinal , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Resultado do Tratamento
19.
Europace ; 25(1): 199-210, 2023 02 08.
Artigo em Inglês | MEDLINE | ID: mdl-36753478

RESUMO

To develop a suite of quality indicators (QIs) for the management of patients with ventricular arrhythmias (VA) and the prevention of sudden cardiac death (SCD). The Working Group comprised experts in heart rhythm management including Task Force members of the 2022 European Society of Cardiology (ESC) Clinical Practice Guidelines for the management of patients with VA and the prevention of SCD, members of the European Heart Rhythm Association, international experts, and a patient representative. We followed the ESC methodology for QI development, which involves (i) the identification of the key domains of care for the management of patients with VA and the prevention of SCD by constructing a conceptual framework of care, (ii) the development of candidate QIs by conducting a systematic review of the literature, (iii) the selection of the final set of QIs using a modified-Delphi method, and (iv) the evaluation of the feasibility of the developed QIs. We identified eight domains of care for the management of patients with VA and the prevention of SCD: (i) structural framework, (ii) screening and diagnosis, (iii) risk stratification, (iv) patient education and lifestyle modification, (v) pharmacological treatment, (vi) device therapy, (vii) catheter ablation, and (viii) outcomes, which included 17 main and 4 secondary QIs across these domains. Following a standardized methodology, we developed 21 QIs for the management of patients with VA and the prevention of SCD. The implementation of these QIs will improve the care and outcomes of patients with VA and contribute to the prevention of SCD.


Assuntos
Cardiologia , Indicadores de Qualidade em Assistência à Saúde , Humanos , Arritmias Cardíacas/complicações , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia , Morte Súbita Cardíaca/prevenção & controle
20.
J Cardiovasc Electrophysiol ; 34(1): 82-89, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36321661

RESUMO

INTRODUCTION: Aim of this study was to evaluate the incidence of ablation-induced endoscopically detected esophageal lesions (EDEL) and gastroparesis in patients undergoing high-power short-duration (HPSD) atrial fibrillation (AF) ablation using different target ablation index (AI) values. METHODS AND RESULTS: Consecutive patients undergoing AF ablation were included. Radiofrequency (RF) ablation was performed using HPSD ablation (50 W, target AI of 320 and 350 (group 1) and 380 (group 2) at posterior wall). Postablation endoscopy was performed in all patients. In total, 233 patients (66.8 ± 10 years; 52% male) were included consecutively (n = 137 patients in group 1 and n = 96 patients in group 2). Mean AI values und RF time at posterior wall was significantly higher and longer in group 2 compared to group 1 patients (413 ± 9 vs. 392 ± 19 AI, p < 0.01; 9.0 ± 0.8 s vs. 7.8 ± 0.7 s, p < 0.01). Esophageal endoscopy revealed esophageal lesions or gastroparesis in 43 of 233 patients (18.5%) in the total cohort (13.1% in group 1 and 26.0% in group 2; p = 0.02). Incidence of EDEL was 8.0% and 13.5% in group 1 and group 2, respectively. According to logistic analysis incidence of EDEL and/or gastroparesis was significantly lower in patients with a higher body mass index and higher in group 2 patients compared to group 1 patients. CONCLUSION: The incidence of EDEL or gastroparesis in patients undergoing HPSD AF ablation was 18.5% in the total cohort. The risk of EDEL and gastroparesis was associated with a higher AI target value of 380 compared to 320 and 350 at posterior wall and was reversely associated with body mass index.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Gastroparesia , Veias Pulmonares , Humanos , Masculino , Feminino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Incidência , Gastroparesia/diagnóstico , Gastroparesia/epidemiologia , Gastroparesia/etiologia , Esôfago/diagnóstico por imagem , Esôfago/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA