Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
J Patient Rep Outcomes ; 8(1): 44, 2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38607610

RESUMO

BACKGROUND: The concept of Positive Health (PH) has gained increasing attention as a way of measuring individuals' ability to adapt in the face of contextual challenges. However, a suitable measurement instrument for PH that encompasses contextual factors has not yet been developed. This paper responds to this need by developing a Context-specific Positive Health (CPH) measurement instrument that aligns with the Capability Approach (CA). METHODS: The measurement instrument was developed and tested among a representative sample of 1002 Dutch internet survey panel members with diverse sociodemographic backgrounds. The instrument was developed in two stages: a preparation phase consisting of focus groups and expert consultations, and a validation among a representative panel of Dutch citizens. The goal of the preparation phase, was to pilot test and refine previously proposed Positive Health questionnaires into an initial version of the CPHQ. The validation phase aimed to examine the initial CPHQ's factorial validity using Factor Analysis, and its concurrent validity using Multivariate Regression Analysis. RESULTS: The developed questionnaire demonstrated adequate factorial and concurrent validity. Furthermore, it explicitly includes an assessment of resilience, this being a key component of PH. CONCLUSIONS: The introduced measurement tool, the CPHQ, comprises 11 dimensions that we have labeled as follows: relaxation, autonomy, fitness, perceived environmental safety, exclusion, social support, financial resources, political representation, health literacy, resilience, and enjoyment. In this article, we present four major contributions. Firstly, we embedded the measurement in a theoretical framework. Secondly, we focused the questionnaire on a key concept of Positive Health - the "ability to adapt." Thirdly, we addressed issues of health inequality by considering contextual factors. Finally, we facilitated the development of more understandable measurement items.


Assuntos
Etnicidade , Disparidades nos Níveis de Saúde , Humanos , Análise Fatorial , Exercício Físico , Grupos Focais
2.
EJNMMI Phys ; 10(1): 55, 2023 Sep 13.
Artigo em Inglês | MEDLINE | ID: mdl-37702889

RESUMO

BACKGROUND: Current guidelines of the radioiodine uptake (RAIU) test allow the use of different equipment, isotopes, activity and region-of-interest (ROI). We evaluated presence and extent of these differences in clinical practice and evaluated the effect of some of these variations on RAIU outcomes. Also, gamma camera-specific reference standards were calculated and retrospectively compared with measurements obtained during clinical RAIU tests. MATERIALS AND METHODS: First, questionnaires were sent to Dutch nuclear medicine departments requesting information about equipment usage, isotope, isotope formulation, activity and measurement techniques. Secondly, a neck phantom containing a range of activities in capsule or water-dissolved formulation was scanned. Counts were measured using automatic ROI, square box ROI or all counts in the image. Thirdly, clinical RAIU data were collected during 2015-2018 using three different gamma cameras. Reference standards for each scanner were calculated using regression analysis between reference activity and measured counts. Uptake measurements using this gamma camera-specific reference standard were compared with original measurements. RESULTS: The survey demonstrated significant differences in isotope, isotope formulation, activity, use of neck phantoms, frequency and duration of reference measurements, distance to collimator, use of background measurements and ROI delineation. The phantom study demonstrated higher counts for the water-dissolved formulation than capsules using both automatic and square box ROI. Also, higher counts were found using a square box ROI than an automatic ROI. The retrospective study showed feasibility of RAIU calculations using camera-specific reference standards and good correlation with the original RAIU measurements. CONCLUSIONS: This study demonstrated considerable technical variation in RAIU measurement in clinical practice. The phantom study demonstrated that these differences could result in differences in count measurements, potentially resulting in different dose calculations for radioactive iodine therapy. Retrospective data suggest that camera-specific reference standards may be used instead of individual reference measurements using separate activity sources, which may thus eliminate some sources of variation.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA