Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Eur Radiol ; 30(6): 3334-3345, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32072257

RESUMO

OBJECTIVES: This study compared the accuracy of an automated, vessel-specific minimum cost path (MCP) myocardial perfusion territory assignment technique as compared with the standard American Heart Association 17-segment (AHA) model. METHODS: Six swine (42 ± 9 kg) were used to evaluate the accuracy of the MCP technique and the AHA method. In each swine, a dynamic acquisition, comprised of twenty consecutive whole heart volume scans, was acquired with a computed tomography scanner, following peripheral injection of contrast material. From this acquisition, MCP and AHA perfusion territories were determined, for the left (LCA) and right (RCA) coronary arteries. Each animal underwent additional dynamic acquisitions, consisting of twenty consecutive volume scans, following direct intracoronary contrast injection into the LCA or RCA. These images were used as the reference standard (REF) LCA and RCA perfusion territories. The MCP and AHA techniques' perfusion territories were then quantitatively compared with the REF perfusion territories. RESULTS: The myocardial mass of MCP perfusion territories (MMCP) was related to the mass of reference standard perfusion territories (MREF) by MMCP = 0.99MREF + 0.39 g (r = 1.00; R2 = 1.00). The mass of AHA perfusion territories (MAHA) was related to MREF by MAHA = 0.81MREF + 5.03 g (r = 0.99; R2 = 0.98). CONCLUSION: The vessel-specific MCP myocardial perfusion territory assignment technique more accurately quantifies LCA and RCA perfusion territories as compared with the current standard AHA 17-segment model. Therefore, it can potentially provide a more comprehensive and patient-specific evaluation of coronary artery disease. KEY POINTS: • The minimum cost path (MCP) technique accurately determines left and right coronary artery perfusion territories, as compared with the American Heart Association 17-segment (AHA) model. • The minimum cost path (MCP) technique could be applied to cardiac computed-tomography angiography images to accurately determine patient-specific left and right coronary artery perfusion territories. • The American Heart Association 17-segment (AHA) model often fails to accurately determine left and right coronary artery perfusion territories, especially in the inferior and inferoseptal walls of the left ventricular myocardium.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico , Circulação Coronária/fisiologia , Vasos Coronários/diagnóstico por imagem , Imagem de Perfusão do Miocárdio/métodos , American Heart Association , Animais , Doença da Artéria Coronariana/fisiopatologia , Vasos Coronários/fisiopatologia , Modelos Animais de Doenças , Suínos , Estados Unidos
2.
J Cardiovasc Comput Tomogr ; 12(5): 425-435, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30042078

RESUMO

BACKGROUND: As combined morphological and physiological assessment of coronary artery disease (CAD) is necessary to reliably resolve CAD severity, the objective of this study was to validate an automated minimum-cost path assignment (MCP) technique which enables accurate, vessel-specific assignment of the left (LCA) and right (RCA) coronary perfusion territories using computed tomography (CT) angiography data for both left and right ventricles. METHODS: Six swine were used to validate the MCP technique. In each swine, a dynamic acquisition comprised of twenty consecutive volume scans was acquired with a 320-slice CT scanner following peripheral injection of contrast material. From this acquisition the MCP technique was used to automatically assign LCA and RCA perfusion territories for the left and right ventricles, independently. Each animal underwent another dynamic CT acquisition following direct injection of contrast material into the LCA or RCA. Using this acquisition, reference standard LCA and RCA perfusion territories were isolated from the myocardial blush. The accuracy of the MCP technique was evaluated by quantitatively comparing the MCP-derived LCA and RCA perfusion territories to these reference standard territories. RESULTS: All MCP perfusion territory masses (MassMCP) and all reference standard perfusion territory masses (MassRS) in the left ventricle were related by MassMCP = 0.99MassRS+0.35 g (r = 1.00). MassMCP and MassRS in the right ventricle were related by MassMCP = 0.94MassRS+0.39 g (r = 0.96). CONCLUSION: The MCP technique was validated in a swine animal model and has the potential to be used for accurate, vessel-specific assignment of LCA and RCA perfusion territories in both the left and right ventricular myocardium using CT angiography data.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Circulação Coronária , Estenose Coronária/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Tomografia Computadorizada Multidetectores/métodos , Imagem de Perfusão do Miocárdio/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Animais , Simulação por Computador , Estenose Coronária/fisiopatologia , Vasos Coronários/fisiopatologia , Masculino , Modelos Animais , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Sus scrofa
3.
Radiology ; 286(1): 93-102, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-29059038

RESUMO

Purpose To retrospectively validate a first-pass analysis (FPA) technique that combines computed tomographic (CT) angiography and dynamic CT perfusion measurement into one low-dose examination. Materials and Methods The study was approved by the animal care committee. The FPA technique was retrospectively validated in six swine (mean weight, 37.3 kg ± 7.5 [standard deviation]) between April 2015 and October 2016. Four to five intermediate-severity stenoses were generated in the left anterior descending artery (LAD), and 20 contrast material-enhanced volume scans were acquired per stenosis. All volume scans were used for maximum slope model (MSM) perfusion measurement, but only two volume scans were used for FPA perfusion measurement. Perfusion measurements in the LAD, left circumflex artery (LCx), right coronary artery, and all three coronary arteries combined were compared with microsphere perfusion measurements by using regression, root-mean-square error, root-mean-square deviation, Lin concordance correlation, and diagnostic outcomes analysis. The CT dose index and size-specific dose estimate per two-volume FPA perfusion measurement were also determined. Results FPA and MSM perfusion measurements (PFPA and PMSM) in all three coronary arteries combined were related to reference standard microsphere perfusion measurements (PMICRO), as follows: PFPA_COMBINED = 1.02 PMICRO_COMBINED + 0.11 (r = 0.96) and PMSM_COMBINED = 0.28 PMICRO_COMBINED + 0.23 (r = 0.89). The CT dose index and size-specific dose estimate per two-volume FPA perfusion measurement were 10.8 and 17.8 mGy, respectively. Conclusion The FPA technique was retrospectively validated in a swine model and has the potential to be used for accurate, low-dose vessel-specific morphologic and physiologic assessment of coronary artery disease. © RSNA, 2017.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Imagem de Perfusão do Miocárdio/métodos , Tomografia Computadorizada por Raios X/métodos , Animais , Área Sob a Curva , Pressão Sanguínea/fisiologia , Modelos Animais de Doenças , Frequência Cardíaca/fisiologia , Reprodutibilidade dos Testes , Suínos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA