Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Gastroenterology ; 167(2): 392-399.e2, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38331204

RESUMO

BACKGROUND & AIMS: Artificial intelligence (AI)-based optical diagnosis systems (CADx) have been developed to allow pathology prediction of colorectal polyps during colonoscopies. However, CADx systems have not yet been validated for autonomous performance. Therefore, we conducted a trial comparing autonomous AI to AI-assisted human (AI-H) optical diagnosis. METHODS: We performed a randomized noninferiority trial of patients undergoing elective colonoscopies at 1 academic institution. Patients were randomized into (1) autonomous AI-based CADx optical diagnosis of diminutive polyps without human input or (2) diagnosis by endoscopists who performed optical diagnosis of diminutive polyps after seeing the real-time CADx diagnosis. The primary outcome was accuracy in optical diagnosis in both arms using pathology as the gold standard. Secondary outcomes included agreement with pathology for surveillance intervals. RESULTS: A total of 467 patients were randomized (238 patients/158 polyps in the autonomous AI group and 229 patients/179 polyps in the AI-H group). Accuracy for optical diagnosis was 77.2% (95% confidence interval [CI], 69.7-84.7) in the autonomous AI group and 72.1% (95% CI, 65.5-78.6) in the AI-H group (P = .86). For high-confidence diagnoses, accuracy for optical diagnosis was 77.2% (95% CI, 69.7-84.7) in the autonomous AI group and 75.5% (95% CI, 67.9-82.0) in the AI-H group. Autonomous AI had statistically significantly higher agreement with pathology-based surveillance intervals compared to AI-H (91.5% [95% CI, 86.9-96.1] vs 82.1% [95% CI, 76.5-87.7]; P = .016). CONCLUSIONS: Autonomous AI-based optical diagnosis exhibits noninferior accuracy to endoscopist-based diagnosis. Both autonomous AI and AI-H exhibited relatively low accuracy for optical diagnosis; however, autonomous AI achieved higher agreement with pathology-based surveillance intervals. (ClinicalTrials.gov, Number NCT05236790).


Assuntos
Inteligência Artificial , Pólipos do Colo , Colonoscopia , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Colonoscopia/métodos , Pólipos do Colo/patologia , Pólipos do Colo/diagnóstico por imagem , Pólipos do Colo/diagnóstico , Idoso , Valor Preditivo dos Testes , Diagnóstico por Computador , Reprodutibilidade dos Testes , Neoplasias Colorretais/diagnóstico , Neoplasias Colorretais/patologia , Adulto
2.
Scand J Gastroenterol ; 59(1): 112-117, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37743643

RESUMO

INTRODUCTION: Serrated lesions (SLs) including traditional serrated adenomas (TSA), large hyperplastic polyps (HP) and sessile serrated lesions (SSLs) are associated with high incomplete resection rates. Margin ablation combined with EMR (EMR-T) has become routine to reduce local recurrence while cold snare polypectomy (CSP) is becoming recognized as equally effective for large SLs. Our aim was to evaluate local recurrence rates (LRR) and the use of margin ablation in preventing recurrence in a retrospective cohort study. METHODS: Patients undergoing resection of ≥15 mm colorectal SLs from 2010-2022 were identified through a pathology database and electronic medical records search. Hereditary CRC syndromes, first follow-up > 18 months or no follow-up, surgical resection were excluded. Primary outcome was LRRs (either histologic or visual) during the first 18-month follow-up. Secondary outcomes were LRRs according to size, and resection technique. RESULTS: 191 polyps in 170 patients were resected (59.8% women; mean age, 65 years). The mean size of polyps was 22.4 mm, with 107 (56.0%) ≥20 mm. 99 polyps were resected with EMR, 39 with EMR-T, and 26 with CSP. Mean first surveillance was 8.2 mo. Overall LRR was 18.8% (36/191) (16.8% for ≥20 mm, 17.9% for ≥30 mm). LRR was significantly lower after EMR-T when compared with EMR (5.1% vs. 23.2%; p = 0.013) or CSP (5.1% vs. 23.1%; p = 0.031). There was no difference in LRR between EMR without margin ablation and CSP (p = 0.987). CONCLUSION: The local recurrence rate for SLs ≥15 mm is high with 18.8% overall recurrence. EMR with thermal ablation of the margins is superior to both no ablation and CSP in reducing LRRs.


Assuntos
Adenoma , Pólipos do Colo , Neoplasias Colorretais , Ressecção Endoscópica de Mucosa , Humanos , Feminino , Idoso , Masculino , Pólipos do Colo/cirurgia , Pólipos do Colo/patologia , Colonoscopia/métodos , Estudos Retrospectivos , Adenoma/cirurgia , Adenoma/patologia , Neoplasias Colorretais/cirurgia , Neoplasias Colorretais/patologia , Ressecção Endoscópica de Mucosa/métodos
4.
Endosc Int Open ; 11(5): E480-E489, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37206693

RESUMO

Background and study aims Incomplete resection of 4- to 20-mm colorectal polyps occur frequently (> 10 %), putting patients at risk for post-colonoscopy colorectal cancer. We hypothesized that routine use of wide-field cold snare resection with submucosal injection (CSP-SI) might reduce incomplete resection rates (IRRs). Patients and methods Patients aged 45 to 80 years undergoing elective colonoscopies were enrolled in a prospective clinical study. All 4- to 20-mm non-pedunculated polyps were resected using CSP-SI. Post-polypectomy margin biopsies were obtained to determine IRRs through histopathology assessment. The primary outcome was IRR, defined as remnant polyp tissue found on margin biopsies. Secondary outcomes included technical success and complication rates. Results A total of 429 patients (median age 65 years, 47.1 % female, adenoma detection rate 40 %) with 204 non-pedunculated colorectal polyps 4 to 20 mm removed using CSP-SI were included in the final analysis. CSP-SI was technical successful in 97.5 % (199/204) of cases (5 conversion to hot snare polypectomy). IRR for CSP-SI was 3.8 % (7/183) (95 % confidence interval [CI] 2.7 %-5.5 %). IRR was 1.6 % (2/129), 16 % (4/25), and 3.4 % (1/29) for adenomas, serrated lesions, and hyperplastic polyps respectively. IRR was 2.3 % (2/87), 6.3 % (4/64), 4.0 % (6/151), and 3.1 % (1/32) for polyps 4 to 5 mm, 6 to 9 mm, < 10 mm, and 10 to 20 mm, respectively. There were no CSP-SI-related serious adverse events. Conclusions Use of CSP-SI results in lower IRRs compared to what has previously been reported in the literature for hot or cold snare polypectomy when not using wide-field cold snare resection with submucosal injection. CSP-SI showed an excellent safety and efficacy profile, however comparative studies to CSP without SI are required to confirm these results.

5.
Endoscopy ; 55(10): 929-937, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-36377124

RESUMO

BACKGROUND : Cold snare polypectomy (CSP) is increasingly used for polypectomy and is recommended as the first-line modality for small (< 10 mm) polyps. This study aimed to evaluate incomplete resection rates (IRRs) when using CSP for colorectal polyps of 4-20 mm. METHODS : Adults (45-80 years) undergoing screening, surveillance, or diagnostic colonoscopy and CSP by one of nine endoscopists were included. The primary outcome was the IRR for colorectal polyps of 4-20 mm, defined as the presence of polyp tissue in marginal biopsies after resection of serrated polyps or adenomas. Secondary outcomes included the IRR for serrated polyps, ease of resection, and complications. RESULTS: 413 patients were included (mean age 63; 48 % women) and 182 polyps sized 4-20 mm were detected and removed by CSP. CSP required conversion to hot snare resection in < 1 % of polyps of < 10 mm and 44 % of polyps sized 10-20 mm. The IRRs for polyps < 10 mm and ≥ 10 mm were 18 % and 21 %. The IRR was higher for serrated polyps (26 %) compared with adenomas (16 %). The IRR was higher for flat (IIa) polyps (odds ratio [OR] 2.9, 95 %CI 1.1-7.4); and when resection was judged as difficult (OR 4.2, 95 %CI 1.5-12.1), piecemeal resection was performed (OR 6.6, 95 %CI 2.0-22.0), or visible residual polyp was present after the initial resection (OR 5.4, 95 %CI 2.0-14.9). Polyp location, use of a dedicated cold snare, and submucosal injection were not associated with incomplete resection. Intraprocedural bleeding requiring endoscopic intervention occurred in 4.7 %. CONCLUSIONS : CSP for polyps of 4-9 mm is safe and feasible; however, for lesions ≥ 10 mm, CSP failure occurs frequently, and the IRR remains high even after technical success. Incomplete resection was associated with flat polyps, visual residual polyp, piecemeal resection, and difficult polypectomies.


Assuntos
Adenoma , Pólipos do Colo , Neoplasias Colorretais , Adulto , Humanos , Feminino , Pessoa de Meia-Idade , Masculino , Pólipos do Colo/cirurgia , Pólipos do Colo/patologia , Colonoscopia/métodos , Resultado do Tratamento , Biópsia/métodos , Adenoma/cirurgia , Adenoma/patologia , Neoplasias Colorretais/cirurgia , Neoplasias Colorretais/patologia
6.
World J Gastroenterol ; 28(19): 2137-2147, 2022 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-35664039

RESUMO

BACKGROUND: Post-polypectomy surveillance intervals are currently determined based on pathology results. AIM: To evaluate a polyp-based resect and discard model that assigns surveillance intervals based solely on polyp number and size. METHODS: Patients undergoing elective colonoscopies at the Montreal University Medical Center were enrolled prospectively. The polyp-based strategy was used to assign the next surveillance interval using polyp size and number. Surveillance intervals were also assigned using optical diagnosis for small polyps (< 10 mm). The primary outcome was surveillance interval agreement between the polyp-based model, optical diagnosis, and the pathology-based reference standard using the 2020 United States Multi-Society Task Force guidelines. Secondary outcomes included the proportion of reduction in required histopathology evaluations and proportion of immediate post-colonoscopy recommendations provided to patients. RESULTS: Of 944 patients (mean age 62.6 years, 49.3% male, 933 polyps) were enrolled. The surveillance interval agreement for the polyp-based strategy was 98.0% [95% confidence interval (CI): 0.97-0.99] compared with pathology-based assignment. Optical diagnosis-based intervals achieved 95.8% (95%CI: 0.94-0.97) agreement with pathology. When using the polyp-based strategy and optical diagnosis, the need for pathology assessment was reduced by 87.8% and 70.6%, respectively. The polyp-based strategy provided 93.7% of patients with immediate surveillance interval recommendations vs 76.1% for optical diagnosis. CONCLUSION: The polyp-based strategy achieved almost perfect surveillance interval agreement compared with pathology-based assignments, significantly reduced the number of required pathology evaluations, and provided most patients with immediate surveillance interval recommendations.


Assuntos
Pólipos do Colo , Neoplasias Colorretais , Pólipos do Colo/patologia , Colonoscopia/efeitos adversos , Colonoscopia/métodos , Neoplasias Colorretais/patologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Estados Unidos
7.
Gastrointest Endosc ; 96(5): 840-848.e2, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35724695

RESUMO

BACKGROUND AND AIMS: EMR is the mainstay of therapy for large colorectal polyps. Local recurrence after EMR is common and can be reduced using margin ablation. Our aim was to evaluate recurrence rates when using hybrid argon plasma coagulation (h-APC) ablation after EMR. METHODS: Adult patients (aged 18-89 years) undergoing EMR of nonpedunculated colorectal polyps ≥20 mm were enrolled in a prospective multicenter study. h-APC was used to ablate all defect margins and also the resection surface in selected cases. The primary study outcome was recurrence rates found during the first follow-up colonoscopy. Secondary outcomes were technical success and adverse event rates. RESULTS: EMR with h-APC ablation was used in 101 polyps (84 patients, 46.4% women). EMR with h-APC ablation was technically successful in all cases (median EMR time, 15 minutes; median h-APC ablation time, 4 minutes). Median polyp size was 30 mm (range, 20-60). Resected polyps were either adenomas (68/101 [67.3%]), sessile serrated lesions (27/101 [27%]), or adenocarcinomas (6/101 [6%]). The post-EMR recurrence rate was 2.2% (2/91) (95% confidence interval, .27-7.71). All 6 patients with cancer (intramucosal cancer, 4; T1sm cancer, 2) were found to have complete eradication of the primary tumor after EMR with h-APC, and none had lymph node metastasis. Four serious adverse events occurred in 3 patients (2 delayed bleeding [2.4%], 1 abdominal pain [1.2%], and 1 microperforation [1.2%]. All serious adverse events resolved with either endoscopic or antibiotic treatment only. CONCLUSIONS: EMR with h-APC showed a high technical success rate, low adverse event rate, and very low post-EMR recurrence rates. (Clinical trial registration number: NCT04015765.).


Assuntos
Pólipos do Colo , Neoplasias Colorretais , Ressecção Endoscópica de Mucosa , Adulto , Humanos , Feminino , Masculino , Pólipos do Colo/patologia , Coagulação com Plasma de Argônio , Estudos Prospectivos , Colonoscopia , Antibacterianos , Neoplasias Colorretais/cirurgia , Neoplasias Colorretais/etiologia , Ressecção Endoscópica de Mucosa/efeitos adversos , Resultado do Tratamento
8.
Gastrointest Endosc ; 93(3): 712-719.e1, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33275913

RESUMO

BACKGROUND AND AIMS: Optical polyp diagnosis using image-enhanced endoscopy (IEE) allows for real-time histology prediction of colorectal polyps. The aim of this study was to evaluate a recently introduced IEE modality (Optivista [OV]; Pentax Medical, Tokyo, Japan) in a randomized controlled trial. METHODS: In a prospective cohort of subjects (ages 45-80 years) undergoing elective screening, surveillance, or diagnostic colonoscopy, all colorectal polyps between 1 and 5 mm underwent IEE assessment. Study subjects were randomized before their colonoscopy procedure to undergo optical polyp diagnosis using either OV IEE or iScan (IS) IEE. A validated IEE scale (NBI International Colorectal Endoscopic classification) was used for optical polyp diagnosis. The primary outcome was the agreement of surveillance intervals determined when using OV IEE compared with IS IEE in reference with pathology-based surveillance intervals. Secondary outcomes were the percentage of surveillance intervals that could be given on the same day as the procedure, percentage of pathology tests avoided, diagnostic performance, and negative predictive value (NPV) of optical diagnosis for rectosigmoid adenomas. RESULTS: Four hundred ten patients were enrolled in the trial. The polyp detection rate was 58.6%, and the adenoma detection rate was 38.8%. The proportion of correct surveillance interval assignment when using OV or IS IEE was 96.5% versus 96.0% (P = .75). A total of 65.1% of patients could be given same-day surveillance intervals when using OV IEE versus 73.1% for IS IEE (P = .07). The NPV for rectosigmoid adenomas (including sessile serrated adenomas) was 97.5% when using OV IEE and 88.2% when using IS IEE. Using high-confidence optical diagnosis instead of pathology would have resulted in a 44.3% elimination of required pathology examinations for OV IEE versus 52.8% for IS IEE (P = .34). CONCLUSIONS: Optical diagnosis using OV and IS IEE both surpassed the 90% benchmark of surveillance interval assignment, and no significant difference with regard to correct surveillance interval assignment was found. OV IEE surpassed the ≥90% NPV for rectosigmoid adenomas, whereas IS IEE did not. (Clinical trial registration number: NCT03515343.).


Assuntos
Pólipos do Colo , Neoplasias Colorretais , Idoso , Idoso de 80 Anos ou mais , Pólipos do Colo/diagnóstico por imagem , Colonoscopia , Neoplasias Colorretais/diagnóstico por imagem , Humanos , Japão , Pessoa de Meia-Idade , Imagem de Banda Estreita , Valor Preditivo dos Testes , Estudos Prospectivos
9.
Ann Intern Med ; 173(12): 989-1001, 2020 12 15.
Artigo em Inglês | MEDLINE | ID: mdl-32894695

RESUMO

DESCRIPTION: Hereditary hemorrhagic telangiectasia (HHT) is an autosomal dominant disease with an estimated prevalence of 1 in 5000 that is characterized by the presence of vascular malformations (VMs). These result in chronic bleeding, acute hemorrhage, and complications from shunting through VMs. The goal of the Second International HHT Guidelines process was to develop evidence-based consensus guidelines for the management and prevention of HHT-related symptoms and complications. METHODS: The guidelines were developed using the AGREE II (Appraisal of Guidelines for Research and Evaluation II) framework and GRADE (Grading of Recommendations Assessment, Development and Evaluation) methodology. The guidelines expert panel included expert physicians (clinical and genetic) in HHT from 15 countries, guidelines methodologists, health care workers, health care administrators, patient advocacy representatives, and persons with HHT. During the preconference process, the expert panel generated clinically relevant questions in 6 priority topic areas. A systematic literature search was done in June 2019, and articles meeting a priori criteria were included to generate evidence tables, which were used as the basis for recommendation development. The expert panel subsequently convened during a guidelines conference to conduct a structured consensus process, during which recommendations reaching at least 80% consensus were discussed and approved. RECOMMENDATIONS: The expert panel generated and approved 6 new recommendations for each of the following 6 priority topic areas: epistaxis, gastrointestinal bleeding, anemia and iron deficiency, liver VMs, pediatric care, and pregnancy and delivery (36 total). The recommendations highlight new evidence in existing topics from the first International HHT Guidelines and provide guidance in 3 new areas: anemia, pediatrics, and pregnancy and delivery. These recommendations should facilitate implementation of key components of HHT care into clinical practice.


Assuntos
Telangiectasia Hemorrágica Hereditária/diagnóstico , Telangiectasia Hemorrágica Hereditária/terapia , Anemia/etiologia , Anemia/terapia , Malformações Arteriovenosas/etiologia , Malformações Arteriovenosas/terapia , Criança , Epistaxe/etiologia , Epistaxe/terapia , Hemorragia Gastrointestinal/etiologia , Hemorragia Gastrointestinal/terapia , Doenças Genéticas Inatas/etiologia , Doenças Genéticas Inatas/terapia , Humanos , Fígado/irrigação sanguínea , Telangiectasia Hemorrágica Hereditária/complicações
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA