Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
1.
Nanoscale Adv ; 5(8): 2280-2287, 2023 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-37056619

RESUMO

Silver nanoparticle photoreduction synthesis by direct laser writing is a process that enables copper micro-track production on very specific polymers. However, some important 3D printing polymers, such as acrylonitrile butadiene styrene (ABS) and acrylates, do not accept this treatment on their surface. This work presents an approach to produce copper microcircuitry on 3D substrates from these materials by using direct laser writing at low power (32 mW CW diode laser). We show that by coating a thin layer of polyimide (PI) on a 3D-printed geometry, followed by a sequence of chemical treatments and low-power laser-induced photoreduction, copper tracks can be produced using silver as catalyst. The surface chemistry of the layer through the different stages of the process is monitored by FTIR and X-ray photoelectron spectroscopy. The copper tracks are selectively grown on the laser-patterned areas by electroless copper deposition, with conductivity (1.2 ± 0.7) × 107 S m-1 and a width as small as 28 µm. The patterns can be written on 3D structures and even inside cavities. The technique is demonstrated by integrating different circuits, including a LED circuit on 3D printed photopolymer acrylate and a perovskite solar cell on an ABS 3D curved geometry.

2.
Artigo em Inglês | MEDLINE | ID: mdl-35582462

RESUMO

This paper describes an innovative remote surface sterilization approach applicable to the new coronavirus, severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). The process is based on the application of a liquid film on the surface or object under sterilization (OUS). A beacon signal is used to self-steer the transmitted power from the designed retrodirective antenna array (RDA) towards the OUS using circularly polarized fields; then, the sterilization is completed by raising and maintaining the required temperature for a certain time. Results suggest that the process takes 5 minutes or less for an angular coverage range over 60 degrees whilst abiding by the relevant safety protocols. This paper also models the power incident onto the OUS, providing consistent results with full-wave simulations. A practical RDA system is developed using a 2 × 1 microstrip patch array operating at 2.5 GHz and tested through the positioning of a representative target surface. Measurements, developed by sampling the power transmitted by the heterodyne RDA, are reported for various distances and angles, operating in the near-field of the system. To further validate the methodology, an additional experiment investigating virus deactivation through microwave heating was also developed. Measurements have been performed with an open cavity microwave oven on the Coronavirus (strain 229E) and egg white protein in a cuvette. This demonstrates that the temperature increases of aqueous films up to 70 [Formula: see text]C by remote microwave-induced heat can denature proteins and deactivate viruses. Possible applications of the method include sterilization of ambulances, medical equipment, and internet of things (IoT) devices.

3.
Biomicrofluidics ; 15(1): 014105, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33537112

RESUMO

Separation and sorting of biological entities (viruses, bacteria, and cells) is a critical step in any microfluidic lab-on-a-chip device. Acoustofluidics platforms have demonstrated their ability to use physical characteristics of cells to perform label-free separation. Bandpass-type sorting methods of medium-sized entities from a mixture have been presented using acoustic techniques; however, they require multiple transducers, lack support for various target populations, can be sensitive to flow variations, or have not been verified for continuous flow sorting of biological cells. To our knowledge, this paper presents the first acoustic bandpass method that overcomes all these limitations and presents an inherently reconfigurable technique with a single transducer pair for stable continuous flow sorting of blood cells. The sorting method is first demonstrated for polystyrene particles of sizes 6, 10, and 14.5 µm in diameter with measured purity and efficiency coefficients above 75 ± 6% and 85 ± 9%, respectively. The sorting strategy was further validated in the separation of red blood cells from white blood cells and 1 µm polystyrene particles with 78 ± 8% efficiency and 74 ± 6% purity, respectively, at a flow rate of at least 1 µl/min, enabling to process finger prick blood samples within minutes.

4.
Sci Rep ; 11(1): 2584, 2021 01 28.
Artigo em Inglês | MEDLINE | ID: mdl-33510366

RESUMO

Biologic drugs, defined as therapeutic agents produced from or containing components of a living organism, are of growing importance to the pharmaceutical industry. Though oral delivery of medicine is convenient, biologics require invasive injections because of their poor bioavailability via oral routes. Delivery of biologics to the small intestine using electronic delivery with devices that are similar to capsule endoscopes is a promising means of overcoming this limitation and does not require reformulation of the therapeutic agent. The efficacy of such capsule devices for drug delivery could be further improved by increasing the permeability of the intestinal tract lining with an integrated ultrasound transducer to increase uptake. This paper describes a novel proof of concept capsule device capable of electronic application of focused ultrasound and delivery of therapeutic agents. Fluorescent markers, which were chosen as a model drug, were used to demonstrate in vivo delivery in the porcine small intestine with this capsule. We show that the fluorescent markers can penetrate the mucus layer of the small intestine at low acoustic powers when combining microbubbles with focused ultrasound during in vivo experiments using porcine models. This study illustrates how such a device could be potentially used for gastrointestinal drug delivery and the challenges to be overcome before focused ultrasound and microbubbles could be used with this device for the oral delivery of biologic therapeutics.


Assuntos
Engenharia Biomédica/métodos , Pontos Quânticos , Sistemas de Liberação de Medicamentos , Microbolhas
5.
Sensors (Basel) ; 20(12)2020 Jun 19.
Artigo em Inglês | MEDLINE | ID: mdl-32575663

RESUMO

Wireless power transfer (WPT) systems have become increasingly suitable solutions for the electrical powering of advanced multifunctional micro-electronic devices such as those found in current biomedical implants. The design and implementation of high power transfer efficiency WPT systems are, however, challenging. The size of the WPT system, the separation distance between the outside environment and location of the implanted medical device inside the body, the operating frequency and tissue safety due to power dissipation are key parameters to consider in the design of WPT systems. This article provides a systematic review of the wide range of WPT systems that have been investigated over the last two decades to improve overall system performance. The various strategies implemented to transfer wireless power in implantable medical devices (IMDs) were reviewed, which includes capacitive coupling, inductive coupling, magnetic resonance coupling and, more recently, acoustic and optical powering methods. The strengths and limitations of all these techniques are benchmarked against each other and particular emphasis is placed on comparing the implanted receiver size, the WPT distance, power transfer efficiency and tissue safety presented by the resulting systems. Necessary improvements and trends of each WPT techniques are also indicated per specific IMD.


Assuntos
Fontes de Energia Elétrica , Próteses e Implantes , Tecnologia sem Fio , Eletrônica
6.
Ultrasonics ; 104: 106111, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32146382

RESUMO

The deposition of increased volumes of Cu down an interconnect through-hole via (THV) of a Printed Circuit Board (PCB) is highly desirable for the fabrication of increasing component density and PCB stacks. A quality metric, called micro-throwing power, characterises the volume of Cu that can be deposited within a THV. In this paper, we analyse the influence of 1 ± 0.05 MHz megasonic (MS) assisted agitation applied to copper (Cu) electroplating baths on the micro-throwing ability of a standard, non-filling Cu electroplating solution. Our results indicate that megasonic agitation is shown to increase the Cu deposition volume within a THV by 45% for an increase of MS pressure from 225 W to 450 W, highlighting the significance of acoustic pressure as a key parameter to control MS THV plating volume. Bulk fluid flow rate within a 500 L plating tank is shown to increase by 150% due to Eckhart acoustic streaming mechanisms, compared to existing bath agitation techniques and panel movement. From MS plating experiments and COMSOLTM finite element acoustic scattering simulations, transducer orientation is shown to influence plating performance, with higher-order acoustic resonant modes forming within THVs identified as the cause. Simulations indicate that higher potential acoustic energy was coupled into a 0.200 mm diameter THV cavity, width-to-length aspect ratio (ar): 8:1, than a larger cavity of diameter 0.475 mm, ar 3.4:1. The maximum acoustic energy coupled into THV cavity is observed for a wavefront propagating along the axis of the cavity entrance, indicating an ideal alignment for the MS plating setup.

7.
Ultrasound Med Biol ; 46(3): 796-804, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31902446

RESUMO

Wireless capsule endoscopy has been used for the clinical examination of the gastrointestinal (GI) tract for two decades. However, most commercially available devices only utilise optical imaging to examine the GI wall surface. Using this sensing modality, pathology within the GI wall cannot be detected. Micro-ultrasound (µUS) using high-frequency (>20 MHz) ultrasound can provide a means of transmural or cross-sectional image of the GI tract. Depth of imaging is approximately 10 mm with a resolution of between 40-120 µm that is sufficient to differentiate between subsurface histologic layers of the various regions of the GI tract. Ultrasound capsule endoscopy (USCE) uses a capsule equipped with µUS transducers that are capable of imaging below the GI wall surface, offering thereby a complementary sensing technique to optical imaging capsule endoscopy. In this work, a USCE device integrated with a ∼30 MHz ultrasonic transducer was developed to capture a full 360° image of the lumen. The performance of the device was initially evaluated using a wire phantom, indicating an axial resolution of 69.0 µm and lateral resolution of 262.5 µm. Later, in vivo imaging performance was characterised in the oesophagus and small intestine of anaesthetized pigs. The reconstructed images demonstrate clear layer differentiation of the lumen wall. The tissue thicknesses measured from the B-scan images show good agreement with ex vivo images from the literature. The high-resolution ultrasound images in the in vivo porcine model achieved with this device is an encouraging preliminary step in the translation of these devices toward future clinical use.


Assuntos
Endoscopia por Cápsula/métodos , Trato Gastrointestinal/diagnóstico por imagem , Animais , Feminino , Suínos , Ultrassonografia/métodos
8.
Micromachines (Basel) ; 12(1)2020 Dec 31.
Artigo em Inglês | MEDLINE | ID: mdl-33396351

RESUMO

A novel taxonomy of built-in self-test (BIST) methods is presented for the testing of micro-electro-mechanical systems (MEMS). With MEMS testing representing 50% of the total costs of the end product, BIST solutions that are cost-effective, non-intrusive and able to operate non-intrusively during system operation are being actively sought after. After an extensive review of the various testing methods, a classification table is provided that benchmarks such methods according to four performance metrics: ease of implementation, usefulness, test duration and power consumption. The performance table provides also the domain of application of the method that includes field test, power-on test or assembly phase test. Although BIST methods are application dependent, the use of the inherent multi-modal sensing capability of most sensors offers interesting prospects for effective BIST, as well as built-in self-repair (BISR).

9.
Micromachines (Basel) ; 10(8)2019 Aug 17.
Artigo em Inglês | MEDLINE | ID: mdl-31426541

RESUMO

The optimization, manufacturing, and performance characterization of a miniaturized 3D receiver (RX)-based wireless power transfer (WPT) system fed by a multi-transmitter (multi-TX) array is presented in this study for applications in capsule endoscopy (CE). The 200 mm outer diameter, 35 µm thick printed spiral TX coils of 2.8 g weight, is manufactured on a flexible substrate to enable bendability and portability of the transmitters by the patients. The 8.9 mm diameter-4.8 mm long, miniaturized 3D RX-includes a 4 mm diameter ferrite road to increase power transfer efficiency (PTE) and is dimensionally compatible for insertion into current endoscopic capsules. The multi-TX is activated using a custom-made high-efficiency dual class-E power amplifier operated in subnominal condition. A resulting link and system PTE of 1% and 0.7%, respectively, inside a phantom tissue is demonstrated for the proposed 3D WPT system. The specific absorption rate (SAR) is simulated using the HFSSTM software (15.0) at 0.66 W/kg at 1 MHz operation frequency, which is below the IEEE guidelines for tissue safety. The maximum variation in temperature was also measured as 1.9 °C for the typical duration of the capsule's travel in the gastrointestinal tract to demonstrate the patients' tissues safety.

10.
Sci Robot ; 4(31)2019 06 26.
Artigo em Inglês | MEDLINE | ID: mdl-31380501

RESUMO

Diagnostic endoscopy in the gastrointestinal tract has remained largely unchanged for decades and is limited to the visualization of the tissue surface, the collection of biopsy samples for diagnoses, and minor interventions such as clipping or tissue removal. In this work, we present the autonomous servoing of a magnetic capsule robot for in-situ, subsurface diagnostics of microanatomy. We investigated and showed the feasibility of closed-loop magnetic control using digitized microultrasound (µUS) feedback; this is crucial for obtaining robust imaging in an unknown and unconstrained environment. We demonstrated the functionality of an autonomous servoing algorithm that uses µUS feedback, both on benchtop trials as well as in-vivo in a porcine model. We have validated this magnetic-µUS servoing in instances of autonomous linear probe motion and were able to locate markers in an agar phantom with 1.0 ± 0.9 mm position accuracy using a fusion of robot localization and µUS image information. This work demonstrates the feasibility of closed-loop robotic µUS imaging in the bowel without the need for either a rigid physical link between the transducer and extracorporeal tools or complex manual manipulation.

11.
Micromachines (Basel) ; 10(7)2019 Jun 29.
Artigo em Inglês | MEDLINE | ID: mdl-31261902

RESUMO

Two numerical methods based on the Finite Element Method are presented for calculating the secondary acoustic radiation force between interacting spherical particles. The first model only considers the acoustic waves scattering off a single particle, while the second model includes re-scattering effects between the two interacting spheres. The 2D axisymmetric simplified model combines the Gor'kov potential approach with acoustic simulations to find the interacting forces between two small compressible spheres in an inviscid fluid. The second model is based on 3D simulations of the acoustic field and uses the tensor integral method for direct calculation of the force. The results obtained by both models are compared with analytical equations, showing good agreement between them. The 2D and 3D models take, respectively, seconds and tens of seconds to achieve a convergence error of less than 1%. In comparison with previous models, the numerical methods presented herein can be easily implemented in commercial Finite Element software packages, where surface integrals are available, making it a suitable tool for investigating interparticle forces in acoustic manipulation devices.

12.
Nat Rev Gastroenterol Hepatol ; 16(7): 429-447, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-30988520

RESUMO

Capsule endoscopy (CE) has proved to be a powerful tool in the diagnosis and management of small bowel disorders since its introduction in 2001. However, white light imaging (WLI) is the principal technology used in clinical CE at present, and therefore, CE is limited to mucosal inspection, with diagnosis remaining reliant on visible manifestations of disease. The introduction of WLI CE has motivated a wide range of research to improve its diagnostic capabilities through integration with other sensing modalities. These developments have the potential to overcome the limitations of WLI through enhanced detection of subtle mucosal microlesions and submucosal and/or transmural pathology, providing novel diagnostic avenues. Other research aims to utilize a range of sensors to measure physiological parameters or to discover new biomarkers to improve the sensitivity, specificity and thus the clinical utility of CE. This multidisciplinary Review summarizes research into non-WLI CE devices by organizing them into a taxonomic structure on the basis of their sensing modality. The potential of these capsules to realize clinically useful virtual biopsy and computer-aided diagnosis (CADx) is also reported.


Assuntos
Endoscopia por Cápsula/métodos , Enteropatias/diagnóstico , Intestino Delgado/diagnóstico por imagem , Humanos , Reprodutibilidade dos Testes
13.
IEEE Trans Biomed Eng ; 66(3): 632-639, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-29993482

RESUMO

Clinical endoscopy and colonoscopy are commonly used to investigate and diagnose disorders in the upper gastrointestinal tract and colon, respectively. However, examination of the anatomically remote small bowel with conventional endoscopy is challenging. This and advances in miniaturization led to the development of video capsule endoscopy (VCE) to allow small bowel examination in a noninvasive manner. Available since 2001, current capsule endoscopes are limited to viewing the mucosal surface only due to their reliance on optical imaging. To overcome this limitation with submucosal imaging, work is under way to implement microultrasound (µUS) imaging in the same form as VCE devices. This paper describes two prototype capsules, termed Sonocap and Thermocap, which were developed respectively to assess the quality of µUS imaging and the maximum power consumption that can be tolerated for such a system. The capsules were tested in vivo in the oesophagus and small bowel of porcine models. Results are presented in the form of µUS B-scans as well as safe temperature readings observed up to 100 mW in both biological regions. These results demonstrate that acoustic coupling and µUS imaging can be achieved in vivo in the lumen of the bowel and the maximum power consumption that is possible for miniature µUS systems.


Assuntos
Cápsulas Endoscópicas , Endoscopia por Cápsula/instrumentação , Termometria/instrumentação , Ultrassonografia/instrumentação , Animais , Endoscopia por Cápsula/métodos , Colo/diagnóstico por imagem , Colo/fisiologia , Desenho de Equipamento , Feminino , Humanos , Miniaturização/instrumentação , Segurança do Paciente , Suínos , Termometria/métodos , Ultrassonografia/métodos
14.
Micromachines (Basel) ; 9(2)2018 Jan 26.
Artigo em Inglês | MEDLINE | ID: mdl-30393319

RESUMO

Piezoresistive pressure sensors capable of detecting ranges of low compressive stresses have been successfully fabricated and characterised. The 5.5 × 5 × 1.6 mm³ sensors consist of a planar aluminium top electrode and a microstructured bottom electrode containing a two-by-two array of truncated pyramids with a piezoresistive composite layer sandwiched in-between. The responses of two different piezocomposite materials, a Multiwalled Carbon Nanotube (MWCNT)-elastomer composite and a Quantum Tunneling Composite (QTC), have been characterised as a function of applied pressure and effective contact area. The MWCNT piezoresistive composite-based sensor was able to detect pressures as low as 200 kPa. The QTC-based sensor was capable of detecting pressures as low as 50 kPa depending on the contact area of the bottom electrode. Such sensors could find useful applications requiring the detection of small compressive loads such as those encountered in haptic sensing or robotics.

15.
Sensors (Basel) ; 18(8)2018 Aug 13.
Artigo em Inglês | MEDLINE | ID: mdl-30104478

RESUMO

This article reviews existing clinical practices and sensor research undertaken to monitor fetal well-being during labour. Current clinical practices that include fetal heart rate monitoring and fetal scalp blood sampling are shown to be either inadequate or time-consuming. Monitoring of lactate in blood is identified as a potential alternative for intrapartum fetal monitoring due to its ability to distinguish between different types of acidosis. A literature review from a medical and technical perspective is presented to identify the current advancements in the field of lactate sensors for this application. It is concluded that a less invasive and a more continuous monitoring device is required to fulfill the clinical needs of intrapartum fetal monitoring. Potential specifications for such a system are also presented in this paper.


Assuntos
Acidose/diagnóstico , Hipóxia Fetal/diagnóstico , Monitorização Fetal/instrumentação , Trabalho de Parto , Feminino , Humanos , Ácido Láctico/sangue , Gravidez , Couro Cabeludo
16.
Ultrason Sonochem ; 42: 434-444, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29429689

RESUMO

In this research experimental and simulated analysis investigates the influence of megasonic (MS; 1 ±â€¯0.05 MHz) acoustic-assisted electroplating techniques, with respect to the fabrication of through-hole via (THV) and blind-via (BV) interconnects for the Printed Circuit Board (PCB) industry. MS plating of copper down THV and BV interconnects was shown to produce measurable benefits such as increased connectivity throughout a PCB and cost savings. More specifically, a 700% increase of copper plating rate was demonstrated for THVs of 175 µm diameter and depth-to-width aspect ratio (ar) of 5.7:1, compared with electrodeposition under no-agitation conditions. For BVs, a 60% average increase in copper thickness deposition in 150 µm and 200 µm, ar 1:1, was demonstrated against plating under standard manufacturing conditions including bubble agitation and panel movement. Finite element modelling simulations of acoustic scattering revealed 1st harmonic influence for plating rate enhancement.

17.
IEEE Trans Biomed Circuits Syst ; 12(1): 95-105, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29377799

RESUMO

This paper describes the design, fabrication, packaging, and performance characterization of a conformal helix antenna created on the outside of a capsule endoscope designed to operate at a carrier frequency of 433 MHz within human tissue. Wireless data transfer was established between the integrated capsule system and an external receiver. The telemetry system was tested within a tissue phantom and in vivo porcine models. Two different types of transmission modes were tested. The first mode, replicating normal operating conditions, used data packets at a steady power level of 0 dBm, while the capsule was being withdrawn at a steady rate from the small intestine. The second mode, replicating the worst-case clinical scenario of capsule retention within the small bowel, sent data with stepwise increasing power levels of -10, 0, 6, and 10 dBm, with the capsule fixed in position. The temperature of the tissue surrounding the external antenna was monitored at all times using thermistors embedded within the capsule shell to observe potential safety issues. The recorded data showed, for both modes of operation, a low error transmission of 10-3 packet error rate and 10-5 bit error rate and no temperature increase of the tissue according to IEEE standards.


Assuntos
Endoscopia por Cápsula/instrumentação , Tecnologia de Sensoriamento Remoto , Tecnologia sem Fio/instrumentação , Animais , Endoscopia por Cápsula/métodos , Tecnologia de Sensoriamento Remoto/instrumentação , Tecnologia de Sensoriamento Remoto/métodos , Suínos
18.
J Med Eng Technol ; 42(6): 435-442, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30664386

RESUMO

The role of technology in healthcare is rapidly evolving. However, it can be argued that gastroenterology has not kept pace with other medical fields due to the multifaceted needs of this speciality and other issues. Innovation in healthcare technology increasingly requires interdisciplinary collaboration between engineers and clinicians. Nevertheless, working in such an interdisciplinary environment can be challenging due to factors such as working culture, communication and difference in priorities. We surveyed the views of clinicians specialising in gastroenterology and engineers on interdisciplinary health research. The 21 respondents expressed a range of opinions on the perceived benefits and challenges of interdisciplinary collaboration. Though engineers and clinicians recognised its advantages, they expressed a need for further improvement. However, engineers and clinicians differed in how best this could be achieved. The results of this survey are discussed with reference to the literature on interdisciplinary collaboration.


Assuntos
Engenharia Biomédica , Gastroenterologistas/psicologia , Comunicação Interdisciplinar , Pesquisa Interdisciplinar , Atitude , Endoscopia , Humanos , Percepção , Inquéritos e Questionários
19.
Biomimetics (Basel) ; 3(3)2018 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-31105236

RESUMO

Computer-Aided Biomimetics (CAB) tools aim to support the integration of relevant biological knowledge into biomimetic problem-solving processes. Specific steps of biomimetic processes that require support include the identification, selection and abstraction of relevant biological analogies. Existing CAB tools usually aim to support these steps by describing biological systems in terms of functions, although engineering functions do not map naturally to biological functions. Consequentially, the resulting static, functional view provides an incomplete understanding of biological processes, which are dynamic, cyclic and self-organizing. This paper proposes an alternative approach that revolves around the concept of trade-offs. The aim is to include the biological context, such as environmental characteristics, that may provide information crucial to the transfer of biological information to an engineering application. The proposed design process is exemplified by an illustrative case study.

20.
Biomicrofluidics ; 11(5): 054115, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-29152026

RESUMO

High efficiency isolation of cells or particles from a heterogeneous mixture is a critical processing step in lab-on-a-chip devices. Acoustic techniques offer contactless and label-free manipulation, preserve viability of biological cells, and provide versatility as the applied electrical signal can be adapted to various scenarios. Conventional acoustic separation methods use time-of-flight and achieve separation up to distances of quarter wavelength with limited separation power due to slow gradients in the force. The method proposed here allows separation by half of the wavelength and can be extended by repeating the modulation pattern and can ensure maximum force acting on the particles. In this work, we propose an optimised phase modulation scheme for particle separation in a surface acoustic wave microfluidic device. An expression for the acoustic radiation force arising from the interaction between acoustic waves in the fluid was derived. We demonstrated, for the first time, that the expression of the acoustic radiation force differs in surface acoustic wave and bulk devices, due to the presence of a geometric scaling factor. Two phase modulation schemes are investigated theoretically and experimentally. Theoretical findings were experimentally validated for different mixtures of polystyrene particles confirming that the method offers high selectivity. A Monte-Carlo simulation enabled us to assess performance in real situations, including the effects of particle size variation and non-uniform acoustic field on sorting efficiency and purity, validating the ability to separate particles with high purity and high resolution.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA