Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Biosens Bioelectron ; 67: 708-14, 2015 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-25459059

RESUMO

Microcystins are a major group of cyanobacterial heptapeptide toxins found in freshwater and brackish environments. There is currently an urgent requirement for highly-sensitive, rapid and in-expensive detection methodologies for these toxins. A novel single chain fragment variable (scFv) fragment was generated and is the first known report of a recombinant anti-microcystin avian antibody. In a surface plasmon resonance-based immunoassay, the antibody fragment displayed cross-reactivity with seven microcystin congeners (microcystin-leucine-arginine (MC-LR) 100%, microcystin-tyrosine-arginine (MC-YR) 79.7%, microcystin-leucine-alanine (MC-LA) 74.8%, microcystin-leucine-phenylalanine (MC-LF) 67.5%, microcystin-leucine-tryptophan (MC-LW) 63.7%, microcystin-arginine-arginine (MC-RR) 60.1% and nodularin (Nod) 69.3%, % cross reactivity). Following directed molecular evolution of the parental clone the resultant affinity-enhanced antibody fragment was applied in an optimized fluorescence immunoassay on a planar waveguide detection system. This novel immuno-sensing format can detect free microcystin-LR with a functional limit of detection of 0.19 ng mL(-1)and a detection range of 0.21-5.9 ng mL(-1). The assay is highly reproducible (displaying percentage coefficients of variance below 8% for intra-day assays and below 11% for inter-day assays), utilizes an inexpensive cartridge system with low reagent volumes and can be completed in less than twenty minutes.


Assuntos
Técnicas Biossensoriais , Imunoensaio , Microcistinas/isolamento & purificação , Cianobactérias/química , Água Doce/análise , Fragmentos de Imunoglobulinas/química , Fragmentos de Imunoglobulinas/imunologia , Toxinas Marinhas , Microcistinas/química , Proteínas Recombinantes/química , Proteínas Recombinantes/imunologia , Ressonância de Plasmônio de Superfície
2.
Talanta ; 122: 8-15, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24720955

RESUMO

A highly sensitive broad specificity monoclonal antibody was produced and characterised for microcystin detection through the development of a rapid surface plasmon resonance (SPR) optical biosensor based immunoassay. The antibody displayed the following cross-reactivity: MC-LR 100%; MC-RR 108%; MC-YR 68%; MC-LA 69%; MC-LW 71%; MC-LF 68%; and Nodularin 94%. Microcystin-LR was covalently attached to a CM5 chip and with the monoclonal antibody was employed in a competitive 4 min injection assay to detect total microcystins in water samples below the WHO recommended limit (1 µg/L). A 'total microcystin' level was determined by measuring free and intracellular concentrations in cyanobacterial culture samples as this toxin is an endotoxin. Glass bead beating was used to lyse the cells as a rapid extraction procedure. This method was validated according to European Commission Decision 96/23/EC criteria. The method was proven to measure intracellular microcystin levels, the main source of the toxin, which often goes undetected by other analytical procedures and is advantageous in that it can be used for the monitoring of blooms to provide an early warning of toxicity. It was shown to be repeatable and reproducible, with recoveries from spiked samples ranging from 74 to 123%, and had % CVs below 10% for intra-assay analysis and 15% for inter-assay analysis. The detection capability of the assay was calculated as 0.5 ng/mL for extracellular toxins and 0.05 ng/mL for intracellular microcystins. A comparison of the SPR method with LC-MS/MS was achieved by testing six Microcystis aeruginosa cultures and this study yielded a correlation R(2) value of 0.9989.


Assuntos
Anticorpos Monoclonais/metabolismo , Cianobactérias/metabolismo , Líquido Intracelular/metabolismo , Microcistinas/metabolismo , Peptídeos Cíclicos/metabolismo , Ressonância de Plasmônio de Superfície/métodos , Animais , Cianobactérias/química , Líquido Intracelular/química , Líquido Intracelular/microbiologia , Camundongos , Camundongos Endogâmicos BALB C , Microcistinas/análise , Microcystis/química , Microcystis/metabolismo , Peptídeos Cíclicos/análise , Reprodutibilidade dos Testes , Ressonância de Plasmônio de Superfície/normas
3.
Anal Chim Acta ; 769: 108-13, 2013 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-23498128

RESUMO

The study details the development of a fully validated, rapid and portable sensor based method for the on-site analysis of microcystins in freshwater samples. The process employs a novel lysis method for the mechanical lysis of cyanobacterial cells, with glass beads and a handheld frother in only 10 min. The assay utilises an innovative planar waveguide device that, via an evanescent wave excites fluorescent probes, for amplification of signal in a competitive immunoassay, using an anti-microcystin monoclonal with cross-reactivity against the most common, and toxic variants. Validation of the assay showed the limit of detection (LOD) to be 0.78 ng mL(-1) and the CCß to be 1 ng mL(-1). Robustness of the assay was demonstrated by intra- and inter-assay testing. Intra-assay analysis had % C.V.s between 8 and 26% and recoveries between 73 and 101%, with inter-assay analysis demonstrating % C.V.s between 5 and 14% and recoveries between 78 and 91%. Comparison with LC-MS/MS showed a high correlation (R(2)=0.9954) between the calculated concentrations of 5 different Microcystis aeruginosa cultures for total microcystin content. Total microcystin content was ascertained by the individual measurement of free and cell-bound microcystins. Free microcystins can be measured to 1 ng mL(-1), and with a 10-fold concentration step in the intracellular microcystin protocol (which brings the sample within the range of the calibration curve), intracellular pools may be determined to 0.1 ng mL(-1). This allows the determination of microcystins at and below the World Health Organisation (WHO) guideline value of 1 µg L(-1). This sensor represents a major advancement in portable analysis capabilities and has the potential for numerous other applications.


Assuntos
Cianobactérias/metabolismo , Água Doce/análise , Imunoensaio , Microcistinas/análise , Anticorpos Monoclonais/imunologia , Cromatografia Líquida de Alta Pressão , Microcistinas/imunologia , Microcystis/crescimento & desenvolvimento , Microcystis/metabolismo , Espectrometria de Massas em Tandem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA