Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
1.
Vet Med Sci ; 10(3): e1326, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-37987511

RESUMO

BACKGROUND: No guidelines for administering and monitoring anticoagulants intraprocedurally are currently available in dogs, despite the prevalence of procedures necessitating systemic anticoagulation with heparin. OBJECTIVES: To evaluate an activated clotting time (ACT)-based heparin dose-response (HDR) test to predict the individual required heparin dose in dogs during intravascular procedures, and to investigate both the in vitro heparin - ACT and in vitro heparin - factor anti-Xa activity (anti-Xa) relationships in dogs. METHODS: Blood was collected from eight healthy beagles undergoing a cardiac procedure and utilised to establish baseline ACT and for in vitro evaluation. Subsequently, 100 IU/kg heparin was administered intravenously (IV) and ACT was remeasured (HDR test). The required heparin dose for an ACT target response ≥300 s was calculated for each individual and ACT was remeasured after administration of this dose. For in vitro testing, a serial heparin blood dilution (0-0.5-1-2-4 international unit (IU)/mL) was prepared and ACT and anti-Xa were determined using whole blood and frozen plasma, respectively. RESULTS: The HDR test overestimated the required heparin dose in 3/7 dogs. In vitro, ACT and anti-Xa increased significantly with increasing blood heparin concentration. Heparin - ACT was nonlinear in 4/8 dogs at heparin concentrations >2 IU/mL, whereas heparin - anti-Xa remained linear throughout the tested range. CONCLUSIONS: The HDR test poorly estimated the required heparin dose in dogs. This is most likely attributed to a nonlinear heparin - ACT relationship, as observed in vitro. Anti-Xa is a promising alternative for ACT; however, unavailability as a point-of-care test and lack of in vivo target values restrict its current use.


Assuntos
Procedimentos Endovasculares , Heparina , Cães , Animais , Heparina/farmacologia , Anticoagulantes/farmacologia , Coagulação Sanguínea , Procedimentos Endovasculares/veterinária
2.
J Thromb Haemost ; 16(10): 2016-2023, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-30079628

RESUMO

Essentials Triple-positivity is associated with a high risk for a first thrombotic event and recurrence. Identification of triple-positives is dependent on the solid phase assay used. In triple-positivity, IgM only adds value in thrombotic risk stratification together with IgG. Thrombotic risk in triple-positive patients with IgM only, depends on the platform. ABSTRACT: Background The antiphospholipid syndrome (APS) is characterized by thrombosis and/or pregnancy morbidity with the persistent presence of antiphospholipid antibodies (aPL). Triple-positivity (i.e. positivity for lupus anticoagulant [LAC], anti-cardiolipin [aCL] and anti-ß2glycoprotein I [aß2GPI] antibodies) is associated with a high thrombotic risk. Objectives We investigated the variability in triple-positivity detection by measuring the same samples with four commercially available solid phase assays. In addition, the added clinical value of aPL in LAC-positive patients was investigated, as well as the association of IgM triple-positivity and thrombosis. Patients/Methods We included 851 patients from seven European medical centers. Anti-CL and aß2GPI IgG/IgM antibodies were determined by four platforms: BioPlex® 2200, ImmunoCap® EliA, ACL AcuStar® and QUANTA Lite ELISA® . Results Triple-positivity detection by solid phase assays varied, ranging from 89 up to 118 in thrombotic APS patients (n = 258), of which 86 were detected independent of the platform. Lupus anticoagulant positivity resulted in an odds ratio (OR) for thrombosis of 3.4; triple-positivity (irrespective of the isotype) increased the OR from 4.3 up to 5.2, dependent on the platform. Triple-positivity solely for the IgM isotype did not increase the OR for thrombosis compared with LAC positivity. The highest OR for thrombosis was reached for positivity for IgG and IgM aß2GPI and aCL (8.6 up to 28.9). Conclusions Triple-positivity proved to be highly associated with thrombosis, but identification is assay dependent. Within triple-positivity, IgM antibodies only have an added clinical value in patients positive for IgG antibodies.


Assuntos
Anticorpos Anticardiolipina/sangue , Anticorpos Antifosfolipídeos/sangue , Síndrome Antifosfolipídica/diagnóstico , Imunoensaio/métodos , Imunoglobulina G/sangue , Inibidor de Coagulação do Lúpus/sangue , Trombose/etiologia , beta 2-Glicoproteína I/imunologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Síndrome Antifosfolipídica/sangue , Síndrome Antifosfolipídica/complicações , Biomarcadores/sangue , Ensaio de Imunoadsorção Enzimática , Europa (Continente) , Feminino , Humanos , Imunoglobulina M/sangue , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prognóstico , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Trombose/sangue , Adulto Jovem
8.
Int J Lab Hematol ; 40(3): 292-303, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29405578

RESUMO

INTRODUCTION: Haemostasis testing is influenced by many pre-analytical variables, such as storage time and temperature, which can affect the stability of coagulation factors and influence the results of coagulation assays. We investigated the stability of haemostasis tests after storage of aliquoted plasma at RT, including the variability of measurement principle and reagent used for determination. METHODS: Blood samples from 20 healthy volunteers were obtained, processed to PPP and aliquoted. Aliquots were stored at RT for 0 hour, 2 hours, 4 hours, 6 hours, 8 hours, 12 hours, 24 hours and 48 hours. PT, aPTT, fibrinogen, D-Dimers and coagulation factors (FII, FV, FVII, FX, FVIII, FIX, FXI, FXII) were determined by STA-R Max® and ACL-TOP® . VWF:Ag and vWF:RCo were determined by AcuStar® . Clinically relevant changes, compared to the initial measurement, were denoted as a percentage change of > 10% according to the 99% CI. RESULTS: For both analysers, a clinically relevant change of > 10% was observed for FV after 2 hours, FVIII after 4 hours and for aPTT, FII, FVII, FX and FXII after 48 hours of storage at RT. Statistically significant, but no clinically relevant differences were observed after 48-hours storage for PT, fibrinogen and FIX. D-Dimers, FXI, vWF:Ag and vWF:RCo were found stable up to 48 hours at RT. CONCLUSION: Overall, compared to the limits given by the current CLSI guidelines, for most coagulation parameters investigated in this study a longer storage period could be accepted. Time intervals for FVIII and FV dosage were shorter than recommended by the CLSI guidelines. For PT determination, our findings were consistent.


Assuntos
Coagulação Sanguínea , Preservação de Sangue/métodos , Temperatura , Fatores de Coagulação Sanguínea/análise , Preservação de Sangue/normas , Voluntários Saudáveis , Hemostasia , Humanos , Plasma , Fatores de Tempo
10.
J Thromb Haemost ; 15(1): 91-95, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27813343

RESUMO

Essentials Inter-lab variation studies for antiphospholipid antibodies (aPL) with the same assay are lacking. We carried out an assessment of repeatability and reproducibility of an automated aPL assay. High intra-center repeatability for anticardiolipin and aß2 GPI makes duplicate testing unnecessary. Inter-lab reproducibility was high except for aß2GPI IgG. SUMMARY: Background Inter-assay variability is a well-known problem in antiphospholipid antibody testing, because of the lack of standardization. Inter-laboratory reproducibility for the same assay is similarly important. Objectives Testing repeatability and reproducibility of HemosIL® AcuStar for anticardiolipin (aCL) and antiß2-glycoprotein I antibodies (aß2GPI) IgG and IgM. Patients/Methods In this observational study, out of 420 samples from the thrombophilia centers of Ghent and Geneva, 100 samples were randomly selected and successively analyzed in three centers: Ghent (C1, in duplicate for repeatability evaluation), Geneva (C2) and Frankfurt (C3). Results Results from 99 samples were available, including 25 from patients with antiphospholipid syndrome (APS) and 74 from non-APS patients. The intra-center repeatability expressed as intra-class correlation coefficient (ICC) was higher than 0.99 for each parameter. Differences between two measurements rarely exceeded 1 U mL-1 for values below 100 U mL-1 , except for aß2GPI IgG, where differences varied from -4 to 4 U mL-1 . The inter-center ICCs were higher than 0.99, except for aCL IgM (ICC = 0.961). These ICCs remained high even when considering values below 100 U mL-1 (0.943, 0.964 and 0.977 for aCL IgG, aCL gM and aß2GPI IgM, respectively), except for aß2GPI IgG (ICC = 0.652). Qualitative comparison showed less than 5% discordant classification between centers, with somewhat more discordant results for aß2GPI IgG. Conclusions In terms of discriminating properties, the HemosIL® AcuStar has excellent intra-center repeatability and a good inter-center reproducibility for aCL IgG, aCL IgM and aß2GPI IgM. Some concern may arise for aß2GPI IgG.


Assuntos
Anticorpos Antifosfolipídeos/sangue , Medições Luminescentes/normas , Síndrome Antifosfolipídica/imunologia , Automação , Feminino , Humanos , Imunoglobulina G/sangue , Imunoglobulina M/sangue , Gravidez , Reprodutibilidade dos Testes , Trombofilia , beta 2-Glicoproteína I/imunologia
12.
J Thromb Haemost ; 14(9): 1779-87, 2016 09.
Artigo em Inglês | MEDLINE | ID: mdl-27314634

RESUMO

UNLABELLED: Essentials Antibodies to domain 1 of ß2 glycoprotein I (aD1) are a subset of antiphospholipid antibodies. We evaluated the added diagnostic value of an automated aD1 assay in antiphospholipid syndrome. AD1 IgG correctly classifies patients at risk for thrombosis. Agreement between aD1 and aß2GPI IgG is high, limiting the added value of aD1 in our setting. Click to hear Professor de Groot's perspective on new mechanistic understanding in antiphospholipid syndrome SUMMARY: Background Laboratory diagnosis of antiphospholipid syndrome (APS) includes lupus anticoagulant (LAC), anticardiolipin (aCL) or anti-ß2 glycoprotein I (aß2 GPI) antibodies. Antibodies targeting domain 1 of ß2 GPI (aD1) constitute a pathogenic subset of autoantibodies. Objectives In this cohort study, we determined the clinical performance characteristics, additional diagnostic value and the contribution to APS risk stratification of an automated aD1 assay. Patients/Methods LAC, aCL, aß2 GPI and aD1 IgG were measured in 101 APS patients, 123 patients with autoimmune disorders, 82 diseased controls and 120 healthy controls. aD1 antibodies were detected by QUANTA Flash(®) Beta2GPI-Domain 1 chemiluminescence immunoassay. Results With a cut-off value of 20.0 CU, the aD1 IgG assay identifies APS patients in a clinically affected patient cohort with a sensitivity of 53.5% and specificity of 98.8%. It implied a high odds ratio (OR) for clinical events (OR, 17.0; 95% confidence interval [CI], 7.1-40.5). aD1 IgG did not add diagnostic value to the formal aPL panel because aß2 GPI IgG was nearly as specific but more sensitive for APS (sensitivity 56.4%) with a higher OR for clinical events (36.2; 95% CI, 11.1-117.9). High aD1 titers identify triple-positive patients and patients with thrombosis in a ß2 GPI-dependent LAC-positive population. Agreement between aD1 IgG and aß2 GPI IgG was high (positive and negative agreement 91.7% and 98.4%, respectively). Conclusion Detection of aD1 IgG correctly classifies patients at risk of thrombosis. However, the contribution of aD1 IgG to APS diagnosis and risk stratification depends upon the solid phase assays used for aCL and aß2 GPI detection.


Assuntos
Anticorpos/imunologia , Síndrome Antifosfolipídica/imunologia , Trombose/imunologia , beta 2-Glicoproteína I/imunologia , Adulto , Anticorpos Anticardiolipina/imunologia , Anticorpos Antifosfolipídeos/imunologia , Síndrome Antifosfolipídica/diagnóstico , Autoanticorpos/imunologia , Estudos de Coortes , Feminino , Humanos , Imunoensaio , Imunoglobulina G/química , Inibidor de Coagulação do Lúpus/imunologia , Masculino , Pessoa de Meia-Idade , Razão de Chances , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Medição de Risco , Sensibilidade e Especificidade , Trombose/diagnóstico
13.
J Thromb Haemost ; 14(8): 1530-48, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-27279342

RESUMO

UNLABELLED: Essentials The clinical value of IgM antibodies in thrombotic antiphospholipid syndrome (APS) is debated. By review of literature, we reconsidered the clinical value of IgM antibodies in thrombotic APS. More significant correlations with thrombosis were found for the IgG compared to IgM isotype. Unavailability of paired IgG/IgM results hampers evaluating the added value of IgM positivity. Click to hear Dr de Groot's perspective on antiphospholipid syndrome SUMMARY: Background Despite the update of the classification criteria for the antiphospholipid syndrome (APS), difficulties persist in the identification of patients at risk for thrombosis. Current guidelines include assays detecting IgG/IgM anti-ß2 -glycoprotein I and anti-cardiolipin antibodies, although the relevance of IgM antibodies has been debated. Objectives Through a review of the literature from 2001 to 2014, we aimed to formally establish the thrombotic risk stratification potential of IgM as compared with IgG anti-phospholipid antibodies (aPLs). Patients/methods One thousand two hundred and twenty-eight articles were selected by a computer-assisted search of the literature. Of the 177 studies that met our inclusion criteria, the clinical value of IgG/IgM aPLs was established through analysis of odds ratios for thrombosis or percentage of positives in the thrombotic population. Results/conclusions We clearly found more significant correlations with thrombosis for the IgG than for the IgM isotype. Nonetheless, in a minority of studies, significant associations with thrombosis were found for IgM but not IgG antibodies. The unavailability of paired results of IgG and IgM for each separate patient hampers evaluation of the added value of isolated IgM positivity. To fully take advantage of results obtained by future studies, we strongly encourage scientists to provide all studied information per patient. We planned a large multicenter study to investigate clinical associations of isolated/combined positivity for criteria/non-criteria aPLs. Importantly, because of the presence of non-pathogenic aPLs, quantitative assays are characterized by a high false-positivity rate. Optimization of functional assays, such as thrombin generation measuring the whole scheme of coagulation, may help to reduce APS-related morbidity and mortality.


Assuntos
Anticorpos Antifosfolipídeos/imunologia , Síndrome Antifosfolipídica/imunologia , Imunoglobulina G/imunologia , Imunoglobulina M/imunologia , Trombose/imunologia , Anticorpos Anticardiolipina/sangue , Anticorpos Anticardiolipina/imunologia , Anticorpos Antifosfolipídeos/sangue , Síndrome Antifosfolipídica/sangue , Autoanticorpos/sangue , Autoanticorpos/imunologia , Cardiolipinas/imunologia , Humanos , Imunoglobulina G/sangue , Imunoglobulina M/sangue , Razão de Chances , Trombose/sangue , beta 2-Glicoproteína I/sangue , beta 2-Glicoproteína I/imunologia
14.
J Thromb Haemost ; 13(8): 1475-8, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26017873

RESUMO

BACKGROUND: According to the ISTH guidelines for lupus anticoagulant (LAC) testing, the second step in the three-step procedure (screening, mixing, and confirmation) is the mixing test, which improves the discrimination between the presence of an inhibitor and coagulation factor deficiencies such as those occurring in patients receiving vitamin K antagonists (VKAs). OBJECTIVES: From a retrospective analysis of dilute Russell viper venom (dRVVT) results, we evaluated the impact of the mixing test result on the interpretation of LAC positivity. METHODS: We interpreted the dRVVT clotting times with and without taking into account the results of the mixing test in a patient population with prolonged screening test (n = 267) with special attention to the patients receiving VKAs. RESULTS AND CONCLUSIONS: The number of samples classified as 'LAC positive' differed substantially depending on the method of interpretation; 170 and 235 of 267 samples were classified as LAC positive with the three- and two-step procedure, respectively. Discrepancy between the two-step (without mixing step) and the three-step procedure was due to not including a mixing test and was more pronounced in the VKA patient population. Screen/confirm ratios carried out on a 1:1 mix of patient and normal pooled plasma (NPP) gave a lower incidence of 59 of 267. We advise continuing to perform mixing test to avoid false-positives. In patients with discrepant results between the two- and three-step dRVVT interpretation, mainly observed in VKA-treated patients, we advise retesting of the patients preferable beyond the period of anticoagulant therapy and additional testing for anti-beta2GPI and/or anti-cardiolipin antibodies.


Assuntos
Síndrome Antifosfolipídica/diagnóstico , Coagulação Sanguínea , Inibidor de Coagulação do Lúpus/sangue , Tempo de Protrombina , Anticoagulantes/uso terapêutico , Síndrome Antifosfolipídica/sangue , Síndrome Antifosfolipídica/tratamento farmacológico , Biomarcadores/sangue , Coagulação Sanguínea/efeitos dos fármacos , Humanos , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos , Vitamina K/antagonistas & inibidores
16.
Lupus ; 24(7): 736-45, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25391540

RESUMO

Lupus anticoagulant-hypoprothrombinemia syndrome (LA-HPS) is a rare acquired disorder caused by prothrombin antibodies. The disease is most common in the pediatric age group (<16 years), and more prevalent in women. There are well-established clinical diseases associated with LA-HPS, most notably systemic lupus erythematosus (SLE) and viral infections. The clinical manifestation of LA-HPS varies greatly in severity and it may cause severe life-threatening bleeding diathesis. LA-HPS is to be suspected when a patient presents with bleeding and a prolonged activated partial thromboplastin and prothrombin time, in combination with a lupus anticoagulant. The diagnosis is confirmed in the laboratory by identification of reduced prothrombin levels. There are no standardized recommendations for treatment of the hemorrhage associated with the syndrome; corticosteroids are used as first-line treatment. This review summarizes what is currently known about the pathogenesis, clinical features, diagnosis, treatment and prognosis of LA-HPS, and presents two case reports.


Assuntos
Síndrome Antifosfolipídica/sangue , Hipoprotrombinemias/sangue , Inibidor de Coagulação do Lúpus/sangue , Lúpus Eritematoso Sistêmico/sangue , Adulto , Anticorpos Antifosfolipídeos/sangue , Pré-Escolar , Feminino , Humanos , Masculino
17.
J Thromb Haemost ; 12(12): 2034-7, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25244443

RESUMO

BACKGROUND: The HemosIL AcuStar antiphospholipid assay (Instrumentation Laboratory, Bedford, MA, USA) is a fully automated assay using chemiluminescent technology for the detection of anticardiolipin and anti-beta2 glycoprotein-1 antibodies. This assay showed excellent agreement between results of different laboratories. The cutoff values to define positivity were calculated in 250 healthy blood bank donors but were associated with large confidence intervals (CIs). OBJECTIVE: The objective of this study was to more precisely determine the cutoff values of the HemosIL AcuStar antiphospholipid assay by increasing the number of healthy blood bank donors through a multicenter study and by applying a normalization procedure of the distribution of each antibody. METHODS: Five laboratories participated to this study, allowing the inclusion of 626 samples. We used a Box-Cox power transformation method to normalize the distribution and calculate the 99th percentile and the corresponding 95%CI for each antibody. RESULTS: The revised cutoff values were overall lower than those initially calculated with more stringent CIs and yielded a 4.2% increase in sensitivity with a 2.7% decrease in specificity regarding thrombotic events or obstetric complications. CONCLUSIONS: We provide refined cutoff values for the detection of anticardiolipin and anti-beta2 glycoprotein-1 antibodies with the HemosIL AcuStar Antiphospholipid assay that should be preferred for routine use.


Assuntos
Anticorpos Anticardiolipina/sangue , Anticorpos/sangue , Síndrome Antifosfolipídica/sangue , Síndrome Antifosfolipídica/imunologia , Cardiolipinas/imunologia , beta 2-Glicoproteína I/imunologia , Adulto , Algoritmos , Automação , Doadores de Sangue , Cardiolipinas/sangue , Técnicas de Laboratório Clínico/normas , Feminino , Voluntários Saudáveis , Humanos , Luminescência , Masculino , Pessoa de Meia-Idade , Modelos de Riscos Proporcionais , Valores de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Trombose , beta 2-Glicoproteína I/sangue
18.
Int J Lab Hematol ; 36(3): 352-63, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24750682

RESUMO

The laboratory criteria that define patients with antiphospholipid syndrome (APS) include lupus anticoagulant (LAC), anticardiolipin antibodies and anti-ß2 glycoprotein I antibodies (aß2GPI). All assays show methodological shortcomings and the combination of the three tests, each with different sensitivity and specificity, and hence, differences in clinical utility make the laboratory diagnosis of APS challenging. Consensus guidelines and proposals for antiphospholipid antibodies (aPL) testing have been published in the last 20 years and have led to a substantial improvement. Despite efforts so far, standardization is not reached yet, but progress has been made. On-going efforts to reduce the interlaboratory/interassay variations remain important; even an absolute standardization cannot be feasibly achieved. Taking into account the methodological shortcomings of the means we have available, more detailed guidelines may help in adequate performance of aPL testing. This review will focus on the efforts and achievements in standardization and on the weaknesses and strengths of the current available laboratory methods.


Assuntos
Anticorpos Antifosfolipídeos , Síndrome Antifosfolipídica/diagnóstico , Testes Diagnósticos de Rotina/métodos , Testes Diagnósticos de Rotina/normas , Humanos , Inibidor de Coagulação do Lúpus
19.
Int J Lab Hematol ; 36(3): 398-407, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24750687

RESUMO

Acquired hemophilia A (AHA) is a rare bleeding disorder caused by autoantibodies against clotting factor VIII (FVIII). FVIII autoantibody is characterized as polyclonal immunoglobulin G directed against the FVIII procoagulant activity. This disease occurs most commonly in the elderly population and with preponderance of men in nonpregnancy-related AHA. There are well-established clinical associations with AHA such as malignancy, other autoimmune diseases and pregnancy. However, up to 50% of reported cases remain idiopathic. The clinical manifestation of AHA includes mostly spontaneous hemorrhages into skin, muscles and soft tissues, or mucous membranes. AHA should be suspected when a patient with no previous history of bleeding presents with bleeding and an unexplained prolonged activated partial thromboplastin time. The diagnosis is confirmed in the laboratory by the subsequent identification of reduced FVIII levels and FVIII inhibitor titration. There is a high mortality, making prompt diagnosis and treatment vitally important. The principles of treatment consist in controlling the bleeding and eradicating the inhibitor. Because of the overall high relapse rate (15-33%), it is also recommended to follow up these patients. The review summarizes what is currently known about the epidemiology, pathogenesis, clinical features, diagnosis, treatment and prognosis of AHA and starts with a case report.


Assuntos
Hemofilia A/diagnóstico , Idoso de 80 Anos ou mais , Fator VIII/metabolismo , Feminino , Hemofilia A/tratamento farmacológico , Hemofilia A/epidemiologia , Hemofilia A/imunologia , Humanos , Tempo de Tromboplastina Parcial , Prognóstico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA