Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
1.
Eur J Immunol ; : e2451181, 2024 Sep 05.
Artigo em Inglês | MEDLINE | ID: mdl-39233540

RESUMO

Ascertaining the presence of weakly positive anti-HLA donor-specific antibodies (DSA) in organ transplantation with multiplex single antigen beads assays may be challenging despite their high sensitivity due to technical variability issues. Through extensive datasets of Next-Generation Sequencing HLA typings and single antigen analyses, we reassessed the mean fluorescence intensity (MFI) positivity threshold of the assay to enhance accuracy. By showing that some beads were more prone to false positivity than others, we propose a nuanced approach that accounts for nonspecific intrinsic reactivities at the HLA antigen level, that is, on a bead-by-bead basis, as it enhances assay precision and reliability. This is substantiated by a comprehensive statistical analysis of MFI values and the implementation of the determination of a "Quantile Adjusted Threshold 500" (QAT500) value for each bead. Applied to DSA detection during patients' follow-up, this approach discriminated better and earlier low-strength DSA that would later raise their MFI above the clinically relevant threshold of 3000. Moving from a subjective interpretation to a more objective and precise methodology allows for standardizing HLA antibody and DSA detection. The study emphasizes the need for further research with real clinical data to validate and refine this approach.

2.
HLA ; 104(3): e15675, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39247974

RESUMO

The determination of panel reactive antibodies (cPRA) scores plays a critical role in assessing the immunological compatibility between organ transplant recipients and potential donors. Traditional cPRA methods focus on a limited number of HLA loci using physical cytotoxicity tests. However, advancements such as the Luminex single antigen (LSA) assay, which uses mean fluorescence intensity (MFI) of individualised HLA antigens for antibody evaluation, provide a foundation for a more precise assessment. We developed cPRAdictor, a novel cPRA calculation tool using a large series of HLA-type individuals in France with NGS. cPRAdictor was applied to a cohort of 5962 kidney transplant candidates in Paris. We analysed how extending the range of HLA specificities could affect cPRA values. Implementing cPRAdictor revealed and allowed quantification of the significant discrepancies in cPRA values that appeared when HLA loci C and DP, and antigen-specific antibodies were taken into account. Notably, over 43% of the immunised transplant candidates showed an increase in calculated cPRA values when considering C/DP loci and antigen-specific antibodies, negatively impacting their eligibility and prioritisation in the transplantation programme. These findings highlight the necessity of revisiting cPRA calculation methodologies to include a broader spectrum of immunological data, as more exhaustive and precise information regarding anti-HLA antibodies in patients' sera and donor and recipient HLA typing are available prospectively. This will strongly improve both accuracy and equity at the organ allocation step, especially for highly sensitised candidates for whom organ offers are very limited in number.


Assuntos
Antígenos HLA , Teste de Histocompatibilidade , Isoanticorpos , Listas de Espera , Humanos , Teste de Histocompatibilidade/métodos , Antígenos HLA/imunologia , Isoanticorpos/sangue , Isoanticorpos/imunologia , Paris , Transplante de Rim , Doadores de Tecidos , Transplante de Órgãos/métodos , Histocompatibilidade
3.
J Immunol ; 212(12): 1981-1991, 2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-38647382

RESUMO

In transplantation, anti-HLA Abs, especially targeting the DQ locus, are well-known to lead to rejection. These Abs identified by Luminex single Ag assays recognize polymorphic amino acids on HLA, named eplets. The HLA Eplet Registry included 83 DQ eplets, mainly deduced from amino acid sequence alignments, among which 66 have not been experimentally verified. Because eplet mismatch load may improve organ allocation and transplant outcomes, it is imperative to confirm the genuine reactivity of eplets to validate this approach. Our study aimed to confirm 29 nonverified eplets, using adsorption of eplet-positive patients' sera on human spleen mononuclear cells and on transfected murine cell clones expressing a unique DQα- and DQß-chain combination. In addition, we compared the positive beads patterns obtained in the two commercially available Luminex single Ag assays. Among the 29 nonverified DQ eplets studied, 24 were confirmed by this strategy, including the 7 DQα eplets 40E, 40ERV, 75I, 76 V, 129H, 129QS, and 130A and the 17 DQß eplets 3P, 23L, 45G, 56L, 57 V, 66DR, 66ER, 67VG, 70GT, 74EL, 86A, 87F, 125G, 130R, 135D, 167R, and 185I. However, adsorption results did not allow us to conclude for the five eplets 66IT, 75S, 160D, 175E, and 185T.


Assuntos
Antígenos HLA-DQ , Humanos , Animais , Camundongos , Antígenos HLA-DQ/imunologia , Teste de Histocompatibilidade/métodos , Rejeição de Enxerto/imunologia , Leucócitos Mononucleares/imunologia , Sequência de Aminoácidos
4.
HLA ; 103(3): e15441, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38507216

RESUMO

The current practice of HLA genotyping in deceased donors poses challenges due to limited resolution within time constraints. Nevertheless, the assessment of compatibility between anti-HLA sensitized recipients and mismatched donors remains a critical medical need, particularly when dealing with allele-specific (second field genotyping level) donor-specific antibodies. In this study, we present a customized protocol based on the NanoTYPE® HLA typing kit, employing the MinION® sequencer, which enables rapid HLA typing of deceased donors within a short timeframe of 3.75 h on average at a three-field resolution with almost no residual ambiguities. Through a prospective real-time analysis of HLA typing in 18 donors, we demonstrated the efficacy and precision of our nanopore-based method in comparison to the conventional approach and without delaying organ allocation. Indeed, this duration was consistent with the deceased donor organ donation procedure leading to organ allocation via the French Biomedicine Agency. The improved resolution achieved with our protocol enhances the security of organ allocation, particularly benefiting highly sensitized recipients who often present intricate HLA antibody profiles. By overcoming technical challenges and providing comprehensive genotyping data, this approach holds the potential to significantly impact deceased donor HLA genotyping, thereby facilitating optimal organ allocation strategies.


Assuntos
Sequenciamento por Nanoporos , Humanos , Estudos Prospectivos , Antígenos HLA/genética , Alelos , Doadores de Tecidos , Teste de Histocompatibilidade/métodos
5.
HLA ; 103(3): e15424, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38516926

RESUMO

Associations between HLA genotype and disease susceptibility encompass almost all the classic HLA loci. The level of typing resolution enabling a correct identification of an HLA disease susceptibility gene depends on the disease itself and/or on the accumulated knowledge about the molecular involvement of the HLA allele(s) engaged. Therefore, the application of Next Generation Sequencing technologies to HLA disease association, which would improve typing resolution, could prove useful to better understand disease severity. In the present study, we tested a nanopore sequencing approach developed by Omixon Biocomputing Ltd, dedicated to on-demand locus typing for HLA and disease, as an alternative to the conventional widely used sequence specific oligoprobe (SSO) approach. A total of 145 DNA samples used in routine diagnosis by SSO were retrospectively analyzed with nanopore technology, for HLA-A*02 immunotherapy decision for A*29, B*27, B*51, B*57 identification in class I, and DRB1, DQA1, and DQB1 for bullous dermatosis, rheumatoid arthritis, diabetes, and celiac disease requests in class II. Each locus was typed in a separate experiment, except for DQB1 and DQA1, which were analyzed together. Concordance between typings reached 100% for all the loci tested. Ambiguities by nanopore were only found for missing exon coverage. This approach was found to be very well adapted to the routine flow imposed by the SSO technique. This study illustrates the use of the new NanoTYPE MONO kit for single locus HLA sequencing for HLA and disease association diagnosis.


Assuntos
Nanoporos , Humanos , Suscetibilidade a Doenças , Estudos Retrospectivos , Teste de Histocompatibilidade/métodos , Alelos , Sequenciamento de Nucleotídeos em Larga Escala , Haplótipos , Frequência do Gene
6.
Nat Commun ; 15(1): 609, 2024 Jan 19.
Artigo em Inglês | MEDLINE | ID: mdl-38242876

RESUMO

Antibodies reactive to human leukocyte antigens (HLA) represent a barrier for patients awaiting transplantation. Based on reactivity patterns in single-antigen bead (SAB) assays, various epitope matching algorithms have been proposed to improve transplant outcomes. However, some antibody reactivities cannot be explained by amino acid motifs, leading to uncertainty about their clinical relevance. Antibodies against the HLA class II molecule, DQß0603:DQα0103, present in some candidates, represent one such example. Here, we show that peptides derived from amino acids 119-148 of the HLA class I heavy chain are bound to DQß0603:DQα0103 proteins and contribute to antibody reactivity through an HLA-DM-dependent process. Moreover, antibody reactivity is impacted by the specific amino acid sequence presented. In summary, we demonstrate that polymorphic HLA class I peptides, bound to HLA class II proteins, can directly or indirectly be part of the antibody binding epitope. Our findings have potential important implications for the field of transplant immunology and for our understanding of adaptive immunity.


Assuntos
Antígenos HLA , Antígenos de Histocompatibilidade Classe I , Humanos , Especificidade de Anticorpos , Antígenos de Histocompatibilidade Classe I/genética , Anticorpos , Epitopos , Peptídeos
7.
HLA ; 102(3): 369-370, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37226587

RESUMO

The novel HLA-C*05:278N allele has a premature stop codon in exon 4.


Assuntos
Genes MHC Classe I , Antígenos HLA-C , Humanos , Antígenos HLA-C/genética , Alelos , Éxons/genética , Códon sem Sentido , Análise de Sequência de DNA
8.
HLA ; 102(3): 375-377, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37231997

RESUMO

HLA-DRB1*07:143N and HLA-DRB1*07:144 differ from DRB1*07:01:01:01 by single mismatches in exons 3 and 2 respectively.


Assuntos
Cadeias HLA-DRB1 , Humanos , Cadeias HLA-DRB1/genética , Sequência de Bases , Alinhamento de Sequência , Alelos , Éxons/genética
9.
HLA ; 102(3): 390-391, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37208969

RESUMO

The novel HLA-DPB1*1455:01N allele differs from DPB1*05:01:01:01 by one amino acid deletion in exon 3.


Assuntos
Doadores de Tecidos , Humanos , Sequência de Bases , Alelos , Cadeias beta de HLA-DP/genética
10.
HLA ; 102(2): 157-167, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37067656

RESUMO

Several technical limitations of Luminex single antigen (LSA) assays have been described so far. This study focused on a reactivity pattern observed in many sera that cannot be explained by eplets described in the Epitope Registry database and sometimes appearing against a self-HLA allele or antigen. In most cases, this pattern is revealed by a discrepant result when compared with other assays (Luminex PRA, cell-binding assays such as flow cytometry cross match, LSA from another manufacturer…). We focus here on the Cw1/12/15 pattern appearing on the LABScreen class I LSA provided by One Lambda. We documented its behavior using this LSA after acid denaturation of the beads, using Lifecodes LSA from Immucor, and adsorption of sera either on spleen mononuclear cells from deceased donors or on single HLA transfected cell clones. We studied 33 sera from different patients positive for the three Cw beads, selected from our routine patients' LSA database. Nine patients had transplants from a Cw12 or Cw15 donor without any pejorative evolution of the graft, nor post-transplant MFI (mean fluorescence intensity) increase of the Cw1/12/15 beads. A significant increase of MFI was observed after acid denaturation of the LABScreen beads. All sera tested by Lifecodes LSA were negative for these Cw beads. Finally, we found no significant difference of MFI after adsorption on cells from either origin. Therefore, the Cw1/12/15 pattern appears to be a false positive reactivity of the LABScreen single antigen assay.


Assuntos
Transplante de Rim , Humanos , Alelos , Teste de Histocompatibilidade , Antígenos de Histocompatibilidade Classe I , Doadores de Tecidos , Antígenos HLA , Isoanticorpos , Rejeição de Enxerto
12.
HLA ; 101(6): 682-683, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36635211

RESUMO

The novel HLA-C*03:618N allele has one change in exon 1 leading to a premature stop codon.


Assuntos
Genes MHC Classe I , Antígenos HLA-C , Humanos , Antígenos HLA-C/genética , Alelos , Éxons/genética , Códon sem Sentido , Análise de Sequência de DNA
13.
Am J Transplant ; 23(2): 294-297, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36695676

RESUMO

Lung transplant candidates who are highly sensitized against human leucocyte antigen present an ongoing challenge with regards to finding immunologically acceptable donors. Desensitization strategies aimed at reducing preformed donor-specific antibodies have a number of limitations. Imlifidase, an IgG-degrading enzyme derived from Streptococcus pyogenes, is a novel agent that has been used to convert positive crossmatches to negative in kidney transplant candidates, allowing transplantation to occur. We present the first case of imlifidase use for antibody depletion in a highly sensitized lung transplant candidate who went on to undergo a successful bilateral lung transplant.


Assuntos
Transplante de Rim , Transplante de Pulmão , Humanos , Anticorpos , Imunossupressores , Transplante de Rim/efeitos adversos , Doadores de Tecidos , Antígenos HLA , Transplante de Pulmão/efeitos adversos , Teste de Histocompatibilidade , Dessensibilização Imunológica , Rejeição de Enxerto/tratamento farmacológico , Rejeição de Enxerto/etiologia
14.
HLA ; 101(6): 698-699, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36593756

RESUMO

The new HLA-DRB1*15:213 allele results from one nucleotide substitution in exon 3 of HLA-DRB1*15:02:01.


Assuntos
Transplante de Coração , Humanos , Cadeias HLA-DRB1/genética , Alelos , Sequência de Bases , Éxons
15.
HLA ; 101(6): 671-672, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36594565

RESUMO

The novel allele B*08:304 differs from B*08:01:01:01 by one nucleotide substitution in exon 2.


Assuntos
Antígenos HLA-B , Nucleotídeos , Humanos , Sequência de Bases , Alelos , Éxons/genética , Antígenos HLA-B/genética , Análise de Sequência de DNA
16.
HLA ; 101(2): 143-145, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36268577

RESUMO

The novel HLA-A*01:420N allele has two changes in exon 4 leading to premature stop codon.


Assuntos
Códon sem Sentido , Antígenos HLA-A , Humanos , Sequência de Bases , Alelos , Éxons/genética , Antígenos HLA-A/genética , Análise de Sequência de DNA
17.
HLA ; 100(6): 648-649, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35979851

RESUMO

The novel allele HLA-C*17:64Q differs from HLA-C*17:01:01:02 by insertion of a Lysine in exon 2.


Assuntos
Genes MHC Classe I , Antígenos HLA-C , Humanos , Antígenos HLA-C/genética , Alelos , Análise de Sequência de DNA/métodos , Éxons/genética
18.
Transplantation ; 106(12): 2456-2461, 2022 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-35849751

RESUMO

BACKGROUND: HLAs contain combinations of multiple eplets, sometimes shared between numerous HLA alleles. Some authors suggested that single antigen bead (SAB) assays may underestimate the signal of anti-HLA antibodies (Ab) when several beads share the targeted eplet. However, this assumption has not yet been validated experimentally. METHODS: We selected 5 eplets shared by 1-24 beads of the routine SAB kits: the eplet 163LS/G; the 3 eplets 127K, 62GE, and 62GRN thereafter called cross-reactive group 2C; the 82LR eplet, well-known as Bw4; the locally called QB2A5 eplet associated with the DQA1*05:01/DQB1*02:01 combination; and the 40GR DQ eplet. We selected a dozen of sera for each eplet with Ab mean fluorescence intensity (MFI) between 1000 and 15 000 for the beads carrying the targeted eplet. We tested them with the classical SAB panel (SABp), with an isolated bead carrying the eplet (isolated SAB [SABi]) and with a mixture of both (SABp+i). RESULTS: No significant difference in MFI was detected among SABi, SABp, and SABp+i conditions for all the eplets. CONCLUSIONS: We noticed only a nonsignificant difference in the Ab MFI signal due to eplet sharing on the SAB assay. We, therefore, conclude that this phenomenon should no longer be considered as a significant risk factor during patient follow-up pre- or posttransplantation.


Assuntos
Soro Antilinfocitário , Antígenos HLA , Humanos , Teste de Histocompatibilidade , Isoanticorpos , Rejeição de Enxerto/diagnóstico , Rejeição de Enxerto/prevenção & controle
19.
HLA ; 99(6): 573-579, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35411722

RESUMO

Complement-mediated interference is a well described phenomenon in single antigen bead (SAB) Luminex assay that leads to falsely low or negative results for anti-HLA antibody (Ab). In a context of high amount of Ab, the enrichment of the Ab around the bead can lead to complement cascade activation and deposition, thereafter impairing Ab detection. EDTA is now routinely used to circumvent this interference. In this report, we attempted to decipher the role of the phycoerythrin (PE) label conjugated to the secondary Ab in this interference. Indeed, PE is a huge molecule (240 kDa) that could participate to limiting access of the conjugate to its Ab target on the bead. To this purpose, 22 sera displaying complement interference without pre-treatment with EDTA were compared on SAB assay with three detection strategies: the recommended PE-conjugated secondary Ab (IgGPE), an Alexa Fluor 532-conjugated Ab (IgGAF) bearing a tiny 724 Da fluorochrome, and a biotinylated Ab followed by PE-conjugated streptavidin (IgGBiot). Complement interference occurred with the three detection methods, but its depth, defined by the percentage of MFI loss with neat serum, was the highest for IgGPE. Our study highlighted the partial role of the PE fluorochrome in complement interference in SAB assays.


Assuntos
Antígenos HLA , Isoanticorpos , Alelos , Proteínas do Sistema Complemento , Ácido Edético , Corantes Fluorescentes , Teste de Histocompatibilidade/métodos , Humanos , Ficoeritrina
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA