Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
1.
J Nucl Cardiol ; 29(3): 1234-1244, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-33398793

RESUMO

BACKGROUND: Myocardial blood flow (MBF) can be quantified using dynamic PET studies. These studies also inherently contain tomographic images of early bolus displacement, which can provide cardiopulmonary transit times (CPTT) as measure of cardiopulmonary physiology. The aim of this study was to assess the incremental prognostic value of CPTT in heart transplant (OHT) recipients. METHODS: 94 patients (age 56 ± 16 years, 78% male) undergoing dynamic 13N-ammonia stress/rest studies were included, of which 68 underwent right-heart catherization. A recently validated cardiac allograft vasculopathy (CAV) score based on PET measures of regional perfusion, peak MBF and left-ventricular (LV) ejection fraction (LVEF) was used to identify patients with no, mild or moderate-severe CAV. Time-activity curves of the LV and right ventricular (RV) cavities were obtained and used to calculate the difference between the LV and RV bolus midpoint times, which represents the CPTT and is expressed in heartbeats. Patients were followed for a median of 2.5 years for the occurrence of major adverse cardiac events (MACE), including cardiovascular death, hospitalization for heart failure or acute coronary syndrome, or re-transplantation. RESULTS: CPTT was significantly correlated with cardiac filling pressures (r = .434, P = .0002 and r = .439, P = .0002 for right atrial and pulmonary wedge pressure), cardiac output (r = - .315, P = .01) and LVEF (r = - .513, P < .0001). CPTT was prolonged in patients with MACE (19.4 ± 6.0 vs 14.5 ± 3.0 heartbeats, P < .001, N = 15) with CPTT ≥ 17.75 beats showing optimal discriminatory value in ROC analysis. CPTT ≥ 17.75 heartbeats was associated with a 10.1-fold increased risk (P < .001) of MACE and a 7.3-fold increased risk (P < .001) after adjusting for PET-CAV, age, sex and time since transplant. CONCLUSION: Measurements of cardiopulmonary transit time provide incremental risk stratification in OHT recipients and enhance the value of multiparametric dynamic PET imaging, particularly in identifying high-risk patients.


Assuntos
Transplante de Coração , Adulto , Idoso , Biomarcadores , Feminino , Átrios do Coração , Transplante de Coração/efeitos adversos , Transplante de Coração/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Tomografia por Emissão de Pósitrons , Medição de Risco
3.
Q J Nucl Med Mol Imaging ; 54(2): 145-56, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20588211

RESUMO

There is an extensive literature validating the use of positron emission tomography (PET) for the evaluation of regional myocardial perfusion. With PET perfusion imaging, the reported average sensitivity for detecting angiographic stenosis of >50% is 91% (range 83-100%) and the specificity is 89% (range 73-100%). While a sensitive approach for diagnosing obstructive coronary artery disease (CAD), PET (like single photon emission computed tomography) also underestimates the extent of underlying disease. However, PET's unique ability to record changes (from baseline) in left ventricular function during peak stress, as well as quantify myocardial perfusion (in mL/min/g of tissue) and derive estimates of myocardial perfusion reserve can help mitigate this limitation. Recent data suggest that PET can also provide accurate risk prediction in patients with known or suspected CAD, and that this information is additive to clinical risk prediction models. The integration of computed tomography (CT) in hybrid PET/CT scanners offers not only accurate and efficient attenuation correction, but also the possibility of providing diagnostic and prognostic information with the addition of coronary artery calcium scoring and CT coronary angiography. The combination of short lived PET radiopharmaceuticals (e.g., Rubidium-82 and N-13 ammonia) with new technology for the acquisition of the CT imaging data (e.g., prospective gating) allow a comprehensive examination of anatomy and function at a relatively low radiation dose.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Imagem de Perfusão do Miocárdio , Tomografia por Emissão de Pósitrons , Tomografia Computadorizada por Raios X , Angiografia Coronária , Humanos , Processamento de Imagem Assistida por Computador , Prognóstico , Compostos Radiofarmacêuticos
4.
Q J Nucl Med Mol Imaging ; 50(1): 44-52, 2006 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-16557203

RESUMO

Positron emission tomography (PET) is an investigative tool that has allowed unprecedented in vivo quantification of physiologic processes including myocardial perfusion and metabolism. Several technical features make PET an ideal technology for the noninvasive evaluation of cardiac physiology. The exponential growth in the number of PET cameras worldwide, offers new opportunities for cardiac applications of PET. Moreover, the integration of PET and multidetector CT (PET/CT) technology will likely accelerate the clinical use of this modality in cardiology for revealing the degree and location of anatomic stenoses and their physiologic significance, the atherosclerotic plaque burden and its composition. Integrated PET/CT is a powerful noninvasive modality to establish the diagnosis, define risk, and guide management with a single study of CAD patients.


Assuntos
Doença da Artéria Coronariana/diagnóstico , Tomografia por Emissão de Pósitrons/métodos , Técnica de Subtração , Tomografia Computadorizada por Raios X/métodos , Humanos , Padrões de Prática Médica , Integração de Sistemas
5.
Pediatr Cardiol ; 24(2): 138-44, 2003.
Artigo em Inglês | MEDLINE | ID: mdl-12360390

RESUMO

Positron emission tomography (PET) myocardial perfusion imaging has higher spatial resolution than conventional single photon emission computed tomography (SPECT) imaging and allows accurate and reproducible quantification of myocardial blood flow (MBF). In this article, we describe the role of PET myocardial perfusion imaging in clinical decision making in children with suspected coronary abnormalities. We performed a PET myocardial perfusion study using N-13 ammonia in 10 children (median age, 14 years; range, 1-17 years). The indications included exercise-induced chest pain and ST segment changes during exercise testing, coronary artery ectasia, hypertrophic cardiomyopathy with myocardial bridging of the left anterior descending coronary artery, and suspected left coronary stenosis in an infant with William's syndrome. MBF was assessed at baseline and during adenosine hyperemia in all 10 patients and postexercise in 8 patients. Myocardial perfusion was homogeneous at baseline in all 10 patients, during adenosine perfusion in 9 of 10 patients, and postexercise in all 8 patients. Three patients with homogeneous rest and stress perfusion had impaired myocardial flow reserve. The infant with William's syndrome developed a large, reversible perfusion defect in the left coronary territory during adenosine stress and underwent surgical repair. Myocardial flow reserve findings were valuable for clinical decision making in individual patients. We conclude that MBF quantification with N-13 ammonia and PET provides supplemental perfusion information and is helpful in clinical decision making in children with suspected coronary abnormalities.


Assuntos
Anomalias dos Vasos Coronários/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador , Tomografia Computadorizada de Emissão/métodos , Adenosina , Adolescente , Criança , Pré-Escolar , Circulação Coronária/fisiologia , Anomalias dos Vasos Coronários/fisiopatologia , Teste de Esforço , Feminino , Hemodinâmica/fisiologia , Humanos , Lactente , Masculino , Perfusão , Estudos Retrospectivos , Estudos de Amostragem , Sensibilidade e Especificidade , Índice de Gravidade de Doença
6.
J Am Coll Cardiol ; 37(8): 2120-5, 2001 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-11419897

RESUMO

OBJECTIVES: The purpose of this study was to assess myocardial blood flow (MBF) and flow reserve in systemic right ventricles (RV) in long-term survivors of the Mustard operation. BACKGROUND: There is a high prevalence of systemic RV dysfunction and impaired exercise performance in long-term survivors of the Mustard operation. A mismatch between myocardial blood supply and systemic ventricular work demand has been proposed as a potential mechanism. METHODS: We assessed MBF at rest and during intravenous adenosine hyperemia in 11 long-term survivors of a Mustard repair (age 18+/-5 years, median age at repair 0.7 years, follow-up after repair 17+/-5 years) and 13 healthy control subjects (age 23+/-7 years), using N-13 ammonia and positron emission tomography imaging. RESULTS: There was no difference in basal MBF between the systemic RV of survivors of the Mustard operation and the systemic left ventricle (LV) of healthy control subjects (0.80+/-0.19 vs. 0.74+/-0.15 ml/g/min, respectively, p = NS). However, the hyperemic flows were significantly lower in systemic RVs than they were in systemic LVs (2.34+/-0.0.69 vs. 3.44+/-0.62 ml/g/min respectively, p < 0.01). As a result, myocardial flow reserve was lower in systemic RVs than it was in systemic LVs (2.93+/-0.63 vs. 4.74+/-1.09, respectively, p < 0.01). CONCLUSIONS: Myocardial flow reserve is impaired in systemic RVs in survivors of the Mustard operation. This may contribute to systemic ventricular dysfunction in these patients.


Assuntos
Circulação Coronária , Transposição dos Grandes Vasos/cirurgia , Disfunção Ventricular Direita/fisiopatologia , Adolescente , Adulto , Criança , Feminino , Seguimentos , Coração/diagnóstico por imagem , Humanos , Hiperemia/fisiopatologia , Masculino , Período Pós-Operatório , Fluxo Sanguíneo Regional , Tomografia Computadorizada de Emissão , Disfunção Ventricular Direita/diagnóstico por imagem
7.
Artif Organs ; 25(4): 306-12, 2001 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-11318760

RESUMO

In this pilot study, we assessed the feasibility of using positron emission tomography (PET) imaging for in vivo measurement of skeletal muscle ventricle (SMV) tissue blood flow. In 4 dogs, with SMVs prepared from their latissimus dorsi muscle, we quantified SMV tissue blood flow by PET and related it to the tissue flow measured by radiolabeled microspheres under similar physiologic conditions. The tissue blood flow was estimated in SMVs wrapped around a mandrel (not in circulation) at rest and during SMV stimulation (30 and 90 contraction-cycles/min). SMV tissue perfusion was heterogeneous, especially during SMV contraction. Furthermore, there was a linear relationship between SMV tissue flows estimated by PET and those measured by microspheres. We conclude that in vivo imaging of SMV is feasible by PET. Quantification of SMV tissue blood flow by PET has promise as a means of assessing changes in blood flow, but further technical progress needs to be made before absolute flows can be reliably measured.


Assuntos
Ventrículo de Músculo Esquelético/irrigação sanguínea , Tomografia Computadorizada de Emissão , Animais , Cães , Estudos de Viabilidade , Microesferas , Contração Muscular , Radioisótopos de Nitrogênio , Radioisótopos , Ventrículo de Músculo Esquelético/fisiologia
8.
J Nucl Med ; 41(7): 1227-34, 2000 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-10914914

RESUMO

UNLABELLED: Myocardial hibernation refers to a state of persistent left ventricular dysfunction resulting from a chronically reduced blood flow, which is improved or reversed with revascularization. Increased glucose uptake in areas with reduced blood flow at rest on PET has been used successfully to diagnose hibernating myocardium. However, hibernation may represent persistent myocardial stunning resulting from repeated episodes of ischemia and reperfusion rather than from chronic underperfusion. We sought to determine the inter-relationship between blood flow, metabolism, and function in a canine model of repetitive myocardial stunning. METHODS: Ten dogs underwent 4 sequential 5-min intervals of balloon occlusion of the anterior descending or circumflex arteries, each separated by 5 min of reperfusion. Regional blood flow, metabolism, and function were evaluated 3-4 h after reperfusion in all dogs and 24 h and 1 wk after reperfusion in 5 dogs. Regional wall motion was evaluated with echocardiography. Regional blood flow was assessed with radioactive microspheres and by [(13)N]ammonia and PET. Measurements of oxidative metabolism and glucose uptake (during hyperinsulinemic-euglycemic clamping) were derived with [(11)C]-acetate, FDG, and PET. RESULTS: Regional wall motion was severely decreased after the 4 cycles of ischemia, remained impaired 24 h after reperfusion, and normalized after 1 wk. During reflow, blood flow in stunned regions was restored to near-normal levels (0.89 +/- 0.07 versus 0.95 +/- 0.07 mL/g/min, P = 0.023). However, glucose uptake in stunned regions was significantly decreased at 4 h (73% +/- 5% of remote, P < 0.001), remained depressed after 24 h of reflow (83% +/- 4% of remote, P = 0.013), and fully recovered at 1 wk (101% +/- 10% of remote, P = 0.88). Similarly, oxidative metabolism in stunned regions was significantly decreased at 4 h (84% +/- 2% of remote, P < 0.001) and at 24 h (90% +/- 2% of remote, P = 0.005) and recovered to near-normal levels after 1 wk of reperfusion (97% +/- 1% of remote, P = 0.024). The time course of change in postischemic dysfunction correlated with the recovery of oxidative metabolism (r=0.57; P=0.009). CONCLUSION: Myocardium subjected to repetitive stunning showed a prolonged yet reversible reduction in systolic function that was associated with a significant downregulation of glucose and oxidative metabolism despite restoration of normal myocardial blood flow. These findings suggest a unique metabolic adaptation in repetitive stunning that is different from that typically seen in clinical and experimental models of hibernation.


Assuntos
Miocárdio Atordoado/fisiopatologia , Tomografia Computadorizada de Emissão , Animais , Radioisótopos de Carbono , Circulação Coronária , Cães , Ecocardiografia , Fluordesoxiglucose F18 , Glucose/metabolismo , Coração/diagnóstico por imagem , Hemodinâmica , Microesferas , Contração Miocárdica , Reperfusão Miocárdica , Miocárdio Atordoado/diagnóstico por imagem , Miocárdio Atordoado/metabolismo , Miocárdio/metabolismo , Consumo de Oxigênio , Compostos Radiofarmacêuticos
9.
Acad Emerg Med ; 6(10): 998-1004, 1999 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-10530657

RESUMO

OBJECTIVE: To assess the prognostic value of resting Tc-99m sestamibi scanning for adverse cardiac events (ACEs) in ED chest pain patients with a low probability of acute cardiac ischemia (ACI). METHODS: Sixty-nine consenting, hemodynamically stable patients with chest pain and a nondiagnostic electrocardiogram received an injection of 25 mCi of sestamibi during or within two hours of active pain. Scans were interpreted locally by a nuclear cardiologist or radiologist. Interrater reliability was assessed. ACEs of myocardial infarction (MI), death, or revascularization were assessed during the index hospitalization and over a one-year follow-up period. RESULTS: For ACEs, rest scanning with sestamibi had a sensitivity of 71% (95% CI = 0.33 to 0.97), a specificity of 92% (95% CI = 0.82 to 0.97), and an accuracy of 90% (95% CI = 0.87 to 0.99). The positive predictive value was 50% (95% CI = 0.19 to 0.82) and the negative predictive value was 97% (95% CI = 0.87 to 0.98). Sestamibi scanning was highly discriminating, with 62% of patients with positive scans but only 3% with negative scans having ACEs (p<0.001, log rank test). CONCLUSION: In patients with low-risk chest pain, sestamibi scanning has good specificity and moderate sensitivity for ACEs over a 12-month period.


Assuntos
Dor no Peito/diagnóstico por imagem , Isquemia Miocárdica/diagnóstico por imagem , Tecnécio Tc 99m Sestamibi , Dor no Peito/diagnóstico , Diagnóstico Diferencial , Eletrocardiografia , Serviços Médicos de Emergência , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/diagnóstico , Isquemia Miocárdica/diagnóstico , Revascularização Miocárdica , Cintilografia , Sensibilidade e Especificidade
10.
Circulation ; 100(8): 813-9, 1999 Aug 24.
Artigo em Inglês | MEDLINE | ID: mdl-10458716

RESUMO

BACKGROUND: C ardiac sympathetic signals play an important role in the regulation of myocardial perfusion. We hypothesized that sympathetically mediated myocardial blood flow would be impaired in diabetics with autonomic neuropathy. METHODS AND RESULTS: We studied 28 diabetics (43+/-7 years old) and 11 age-matched healthy volunteers. PET was used to delineate cardiac sympathetic innervation with [(11)C]hydroxyephedrine ([(11)C]HED) and to measure myocardial blood flow at rest, during hyperemia, and in response to sympathetic stimulation by cold pressor testing. The response to cardiac autonomic reflex tests was also evaluated. Using ultrasonography, we also measured brachial artery reactivity during reactive hyperemia (endothelium-dependent dilation) and after sublingual nitroglycerin (endothelium-independent dilation). Based on [(11)C]HED PET, 13 of 28 diabetics had sympathetic-nerve dysfunction (SND). Basal flow was regionally homogeneous and similar in the diabetic and normal subjects. During hyperemia, the increase in flow was greater in the normal subjects (284+/-88%) than in the diabetics with SND (187+/-80%, P=0.084) and without SND (177+/-72%, P=0.028). However, the increase in flow in response to cold was lower in the diabetics with SND (14+/-10%) than in those without SND (31+/-12%) (P=0.015) and the normal subjects (48+/-24%) (P<0.001). The flow response to cold was related to the myocardial uptake of [(11)C]HED (P<0.001). Flow-mediated brachial artery dilation was impaired in the diabetics compared with the normal subjects, but it was similar in the diabetics with and without SND. CONCLUSIONS: Diabetic autonomic neuropathy is associated with an impaired vasodilator response of coronary resistance vessels to increased sympathetic stimulation, which is related to the degree of SND.


Assuntos
Doenças do Sistema Nervoso Autônomo/fisiopatologia , Circulação Coronária/fisiologia , Neuropatias Diabéticas/fisiopatologia , Adulto , Radioisótopos de Carbono , Temperatura Baixa , Vasos Coronários/fisiopatologia , Diabetes Mellitus Tipo 1/complicações , Diabetes Mellitus Tipo 2/complicações , Humanos , Pessoa de Meia-Idade , Sistema Nervoso Simpático/fisiopatologia , Resistência Vascular/fisiologia , Vasodilatação/fisiologia
13.
J Thorac Cardiovasc Surg ; 116(6): 997-1004, 1998 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-9832692

RESUMO

OBJECTIVES: Our purpose was to evaluate the long-term benefit of myocardial viability assessment for stratifying risk and selecting patients with low ejection fraction for coronary artery bypass grafting and to determine the relation between the severity of anginal symptoms, the amount of ischemic myocardium, and clinical outcome. METHODS: We studied 93 consecutive patients with severe coronary artery disease and low ejection fraction (median, 25%) who underwent positron emission tomography to delineate the extent of perfusion-metabolism mismatch (reflecting hibernating myocardium) for potential myocardial revascularization. Median follow-up was 4 years (range, 0 to 6.2 years). RESULTS: Fifty patients received medical therapy, and 43 patients underwent bypass grafting. In Cox survival models, heart failure class, prior myocardial infarction, and positron emission tomographic mismatch were the best predictors of survival. Patients with positron emission tomographic mismatch receiving bypass grafting had improved 4-year survival compared with those on medical therapy (75% versus 30%; P =.007) and a significant improvement in angina and heart failure symptoms. In patients without positron emission tomographic mismatch, bypass grafting tended to improve survival and symptoms only in those patients with severe angina (100% versus 60%; P =.085), whereas no survival advantage was apparent in patients with minimal or no anginal symptoms (63% versus 52%; P =.462). CONCLUSIONS: Patients with low ejection fraction and evidence of viable myocardium by positron emission tomography have improved survival and symptoms with coronary bypass grafting compared with medical therapy. In patients without evidence of viability, survival and symptom improvement with bypass grafting are apparent only among those patients with severe angina.


Assuntos
Ponte de Artéria Coronária , Doença das Coronárias/mortalidade , Tomada de Decisões , Disfunção Ventricular Esquerda/mortalidade , Idoso , Causas de Morte , Angiografia Coronária , Doença das Coronárias/diagnóstico , Doença das Coronárias/cirurgia , Feminino , Seguimentos , Humanos , Masculino , Estudos Retrospectivos , Índice de Gravidade de Doença , Volume Sistólico , Taxa de Sobrevida , Tomografia Computadorizada de Emissão , Resultado do Tratamento , Disfunção Ventricular Esquerda/diagnóstico , Disfunção Ventricular Esquerda/cirurgia
14.
J Nucl Cardiol ; 5(6): 558-66, 1998.
Artigo em Inglês | MEDLINE | ID: mdl-9869477

RESUMO

BACKGROUND: Stress perfusion imaging can assess effectively the amount of jeopardized myocardium, but its use for identifying underperfused but viable myocardium has yielded variable results. We evaluated the relation between measurements of myocardial perfusion at rest and during pharmacologic stress and the patterns of tissue viability as determined by positron emission tomographic (PET) imaging. METHODS AND RESULTS: We studied 33 patients with coronary artery disease and left ventricular (LV) dysfunction (LV ejection fraction, 30%+/-8%). PET imaging was used to evaluate regional myocardial perfusion at rest and during pharmacologic stress with [13N]-ammonia as a flow tracer, and to delineate patterns of tissue viability (i.e., perfusion-metabolism mismatch or match) using [18F]-deoxyglucose (FDG). We analyzed 429 myocardial regions, of which 229 were dysfunctional at rest. Of these, 30 had normal perfusion and 199 were hypoperfused. A severe resting defect (deficit >40% below normal) predicted lack of significant tissue viability; 31 of 35 regions (89%) had a PET match pattern denoting transmural fibrosis. Although regions with mild or moderate resting defects (deficit <40% below normal) showed evidence of metabolic activity, perfusion measurements alone failed to identify regions with PET mismatch (reflecting hibernating myocardium). Reversible stress defects were observed with slightly higher frequency in regions with a PET mismatch (10 of 37) than in those with a PET match (36 of 162) pattern of viability. A reversible stress defect was a specific (78%) marker, but was a relatively insensitive marker (27%) of viable myocardium as defined by the PET mismatch pattern. CONCLUSIONS: In patients with LV dysfunction, the severity of regional contractile abnormalities correlates with the severity of flow deficit at rest. Severe reductions in resting blood flow in these dysfunctional regions identify predominantly nonviable myocardium that is unlikely to have improved function after revascularization. Although dysfunctional myocardium with mild to moderate flow reductions contains variable amounts of viable tissue (as assessed by FDG uptake), flow measurements alone do not distinguish between regions with PET mismatch (potentially reversible dysfunction) and PET match (irreversible dysfunction). The presence of an irreversible defect on stress imaging is a relatively specific (78%) marker of PET match, whereas a reversible stress defect is a rather insensitive (27%) marker of viability, as defined by the PET mismatch pattern.


Assuntos
Circulação Coronária/efeitos dos fármacos , Miocárdio/patologia , Tomografia Computadorizada de Emissão , Disfunção Ventricular Esquerda/diagnóstico por imagem , Idoso , Amônia , Doença das Coronárias/complicações , Dipiridamol/farmacologia , Feminino , Fluordesoxiglucose F18 , Coração/diagnóstico por imagem , Humanos , Masculino , Contração Miocárdica , Radioisótopos de Nitrogênio , Compostos Radiofarmacêuticos , Sobrevivência de Tecidos , Vasodilatadores/farmacologia , Disfunção Ventricular Esquerda/patologia , Disfunção Ventricular Esquerda/fisiopatologia
15.
Curr Opin Cardiol ; 13(6): 415-24, 1998 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-9822874

RESUMO

The distinction of left ventricular (LV) dysfunction caused by fibrosis from that arising from viable (hibernating and/or stunned) myocardium has important implications for the management of patients with ischemic cardiomyopathy. In many of these patients, LV function can improve significantly after revascularization. Using positron emission tomography (PET), increased glucose uptake in dysfunctional segments with reduced blood flow at rest (PET mismatch) indicates presence of viable myocardium, whereas a concordant reduction in blood flow and glucose uptake (PET match) reflects myocardial scar. The average positive and negative predictive accuracies of PET for predicting improved function after revascularization are 76% and 82%, respectively. The greater the number of viable myocardial segments, the greater is the probability that revascularization will improve global LV function and, consequently, improve heart failure symptoms and survival. Early revascularization affords a more complete recovery of LV function. In patients with PET mismatch, early referral to revascularization improves long-term survival over medical therapy, regardless of symptoms. In patients without PET mismatch, long-term survival is similar with medical therapy or revascularization especially if minimal or no anginal symptoms are present. Noninvasive evaluation of myocardial viability should be an important component of the diagnostic evaluation of patients with heart failure due to coronary artery disease. This approach will likely enhance the selection of patients with poor cardiac function in whom revascularization will likely improve both the quality and quantity of life.


Assuntos
Ventrículos do Coração/diagnóstico por imagem , Isquemia Miocárdica/cirurgia , Revascularização Miocárdica , Disfunção Ventricular Esquerda/fisiopatologia , Cardiomiopatia Dilatada/complicações , Cardiomiopatia Dilatada/diagnóstico por imagem , Cardiomiopatia Dilatada/fisiopatologia , Progressão da Doença , Seguimentos , Ventrículos do Coração/fisiopatologia , Humanos , Isquemia Miocárdica/complicações , Isquemia Miocárdica/fisiopatologia , Prognóstico , Reprodutibilidade dos Testes , Tomografia Computadorizada de Emissão , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/etiologia
16.
J Am Coll Cardiol ; 31(2): 437-43, 1998 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-9462590

RESUMO

OBJECTIVES: This study sought to evaluate regional myocardial flow reserve in long-term survivors of repair of anomalous left coronary artery from pulmonary artery (ALCAPA) and to relate the flow abnormalities to the patients' exercise performance. BACKGROUND: Patients with ALCAPA usually present during infancy with severe ischemic cardiomyopathy. The left ventricular function recovers after surgical repair. However, the extent of recovery of myocardial blood flow (MBF) and its potential physiologic significance in long-term survivors are unknown. METHODS: We evaluated MBF (ml/g per min) at baseline and during maximal coronary vasodilation by adenosine in 11 patients after ALCAPA repair (median age 17 years, range 7 to 22) using nitrogen-13 ammonia and dynamic positron emission tomographic imaging. Patients also underwent an incremental exercise test with metabolic monitoring. In each patient, MBF was quantified in the three major vascular territories: the left anterior descending and left circumflex coronary artery territories and the right coronary artery (control region) territory. RESULTS: Basal MBF was mildly reduced in the left coronary territories versus the control region (0.79 +/- 0.14 vs. 0.85 +/- 0.19, p = 0.05). During hyperemia, flow in the left coronary territories was significantly lower than that in the control region (2.1 +/- 0.5 vs. 2.6 +/- 0.5, p < 0.001). As a result, myocardial flow reserve was lower in the left coronary territories than in the control region (2.6 +/- 0.7 vs. 3.2 +/- 0.7, p < 0.001). Exercise performance was impaired in patients when compared with age-matched control subjects. Maximal oxygen consumption correlated linearly with maximal hyperemic flows in the left coronary artery territories (r = 0.73, p = 0.03). CONCLUSIONS: Long-term survivors of ALCAPA repair demonstrate regional impairment of myocardial flow reserve. This may contribute to impaired exercise performance by limiting cardiac output reserve.


Assuntos
Circulação Coronária/fisiologia , Anomalias dos Vasos Coronários/cirurgia , Artéria Pulmonar/anormalidades , Sobreviventes , Adenosina , Adolescente , Adulto , Amônia , Pressão Sanguínea/fisiologia , Dióxido de Carbono/metabolismo , Débito Cardíaco/fisiologia , Estudos de Casos e Controles , Criança , Anomalias dos Vasos Coronários/fisiopatologia , Vasos Coronários/efeitos dos fármacos , Vasos Coronários/fisiopatologia , Teste de Esforço , Frequência Cardíaca/fisiologia , Humanos , Hiperemia/fisiopatologia , Isquemia Miocárdica/etiologia , Isquemia Miocárdica/fisiopatologia , Radioisótopos de Nitrogênio , Consumo de Oxigênio/fisiologia , Esforço Físico/fisiologia , Artéria Pulmonar/fisiopatologia , Artéria Pulmonar/cirurgia , Compostos Radiofarmacêuticos , Tomografia Computadorizada de Emissão , Vasodilatadores , Função Ventricular Esquerda/fisiologia
17.
N Engl J Med ; 336(17): 1208-15, 1997 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-9110908

RESUMO

BACKGROUND: The role of cardiac sympathetic nerves in regulating coronary blood flow is controversial. We sought to determine the degree to which cardiac efferent sympathetic signals modulate coronary blood flow. The heterogeneous sympathetic reinnervation in transplanted hearts provides a model for studying the vasomotor responses to adrenergic stimulation in reinnervated and denervated coronary territories of the same heart. METHODS: We studied 14 cardiac-transplant recipients who had normal coronary arteries and no evidence of rejection and 8 normal subjects. We used positron-emission tomography with [(11)C]hydroxyephedrine, an analogue of norepinephrine, to delineate sympathetic innervation. Using [(13)N]ammonia, we measured myocardial blood flow at rest, during adenosine-induced hyperemia, and in response to sympathetic stimulation induced by cold pressor testing. RESULTS: In the transplant recipients, the uptake of [(11)C]hydroxyephedrine was greater in the territory served by the left anterior descending artery (0.15+/-0.01) than in those served by the right coronary artery (0.07+/-0.01, P<0.001) or the circumflex artery (0.09+/-0.01, P<0.001). The basal flow was similar in all three regions, as was the percent increase in flow during hyperemia. However, the increase in flow in response to cold pressor testing was higher in the territory of the left anterior descending artery (46+/-10 percent) than in those of the right coronary artery (16+/-5 percent, P=0.01) or the circumflex artery (23+/-6 percent, P=0.06), although the changes in hemodynamics and levels of circulating catecholamines were similar. No such regional differences were observed in the normal subjects. CONCLUSIONS: Increases in coronary blood flow in response to sympathetic stimulation correlated with the regional norepinephrine content in the cardiac sympathetic-nerve terminals. These findings suggest that cardiac adrenergic signals play an important part in regulating myocardial blood flow.


Assuntos
Circulação Coronária/fisiologia , Transplante de Coração/fisiologia , Coração/inervação , Sistema Nervoso Simpático/fisiologia , Adulto , Radioisótopos de Carbono/metabolismo , Efedrina/análogos & derivados , Efedrina/metabolismo , Epinefrina/sangue , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Miocárdio/metabolismo , Neurônios Eferentes/fisiologia , Norepinefrina/sangue , Terminações Pré-Sinápticas/metabolismo , Valores de Referência , Tomografia Computadorizada de Emissão
18.
J Am Coll Cardiol ; 28(3): 757-62, 1996 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-8772768

RESUMO

OBJECTIVES: The purpose of this investigation was to determine whether myocardial blood flow and flow reserve, based on quantitative measurements derived from positron emission tomographic (PET) imaging, would be globally impaired in children with a previous history of Kawasaki disease and normal epicardial coronary arteries. BACKGROUND: Kawasaki disease is an acute inflammatory process of the arterial walls that results in panvasculitis in early childhood. Children with a history of Kawasaki disease and normal epicardial coronary arteries were previously considered to have normal coronary flow reserve. However, recent studies have reported exercise-induced regional perfusion abnormalities on single-photon positron emission tomographic (SPECT) imaging. METHODS: We assessed myocardial blood flow and flow reserve at rest and during adenosine stress with nitrogen-13 ammonia and PET in 10 children with a history of Kawasaki disease and in 10 healthy young adult volunteers. All children had acute Kawasaki disease 4 to 15 years before the PET study. None of the children had epicardial coronary artery abnormalities at the acute stage of the disease or during follow-up, as assessed by echocardiography. RESULTS: Rest blood flows normalized to the rate-pressure product, an index of cardiac work, were similar in both the patients with Kawasaki disease and healthy adult volunteers (82 +/- 14 vs. 77 +/- 16 ml/100 g per min [mean +/- SD], p = NS). However, hyperemic blood flows were significantly lower in the patients with Kawasaki disease than in the control subjects (263 +/- 64 vs. 340 +/- 57 ml/100 g per min, p = 0.01). As a result, estimates of myocardial flow reserve were lower in the patients with Kawasaki disease than in the healthy young adult volunteers (3.2 +/- 0.7 vs. 4.6 +/- 0.9, p = 0.003). In addition, total coronary resistance was higher in the patients with Kawasaki disease than in the healthy adult volunteers (33 +/- 11 vs. 24 +/- 5 mm Hg/ml per g per min, p = 0.04). Quantitative analysis of perfusion images demonstrated no evidence of regional perfusion abnormalities. CONCLUSIONS: Children with a previous history of Kawasaki disease and normal epicardial coronary arteries exhibit normal rest myocardial blood flows but reduced hyperemic flows and flow reserve. The abnormal hyperemic blood flows and flow reserve suggest an impaired vasodilatory capacity, possibly due to residual damage of the coronary microcirculation.


Assuntos
Circulação Coronária , Vasos Coronários/patologia , Síndrome de Linfonodos Mucocutâneos/fisiopatologia , Tomografia Computadorizada de Emissão , Adenosina/farmacologia , Adolescente , Adulto , Criança , Circulação Coronária/efeitos dos fármacos , Feminino , Humanos , Masculino , Síndrome de Linfonodos Mucocutâneos/diagnóstico por imagem , Síndrome de Linfonodos Mucocutâneos/patologia , Resistência Vascular , Vasodilatadores/farmacologia
19.
Circulation ; 92(12): 3436-44, 1995 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-8521565

RESUMO

BACKGROUND: Studies of patients with coronary artery disease and left ventricular dysfunction have shown that preoperative quantification of myocardial viability may be clinically useful to identify those patients who will benefit most from revascularization both functionally and prognostically. However, the relation between preoperative extent of viability and change in heart failure symptoms has not been documented carefully. We assessed the relation between the magnitude of improvement in heart failure symptoms after coronary artery bypass surgery (CABG) and the extent of myocardial viability as assessed by use of quantitative analysis of preoperative positron emission tomography (PET) images. METHODS AND RESULTS: We studied 36 patients with ischemic cardiomyopathy (mean left ventricular ejection fraction, 28 +/- 6%) undergoing CABG. Preoperative extent and severity of perfusion abnormalities and myocardial viability (flow-metabolism mismatch) were assessed by use of quantitative analysis of PET images with 13N ammonia and fluorine-18-deoxyglucose. Each patient's functional status was determined before and after CABG by use of a Specific Activity Scale. Mean perfusion defect size and severity were 63 +/- 13% and 33 +/- 12%, respectively. Total extent of a PET mismatch correlated linearly and significantly with percent improvement in functional status after CABG (r = .87, P < .0001). A blood flow-metabolism mismatch > or = 18% was associated with a sensitivity of 76% and a specificity of 78% for predicting a change in functional status after revascularization. Patients with large mismatches (> or = 18%) achieved a significantly higher functional status compared with those with minimal or no PET mismatch (< 5%) (5.7 +/- 0.8 versus 4.9 +/- 0.7 metabolic equivalents, P = .009). This resulted in an improvement of 107% in patients with large mismatches compared with only 34% in patients with minimal or no PET mismatch. CONCLUSIONS: In patients with ischemic cardiomyopathy, the magnitude of improvement in heart failure symptoms after CABG is related to the preoperative extent and magnitude of myocardial viability as assessed by use of PET imaging. Patients with large perfusion-metabolism mismatches exhibit the greatest clinical benefit after CABG.


Assuntos
Ponte de Artéria Coronária , Doença das Coronárias/cirurgia , Insuficiência Cardíaca/fisiopatologia , Disfunção Ventricular Esquerda/fisiopatologia , Idoso , Amônia , Doença das Coronárias/diagnóstico por imagem , Doença das Coronárias/fisiopatologia , Desoxiglucose/análogos & derivados , Tolerância ao Exercício , Feminino , Radioisótopos de Flúor , Fluordesoxiglucose F18 , Coração/diagnóstico por imagem , Insuficiência Cardíaca/diagnóstico por imagem , Humanos , Masculino , Miocárdio/metabolismo , Radioisótopos de Nitrogênio , Tomografia Computadorizada de Emissão
20.
Circulation ; 91(7): 1944-51, 1995 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-7895351

RESUMO

BACKGROUND: Coronary arteriography is considered the "gold standard" for evaluating the severity of a coronary stenosis. Because the resistance to blood flow through a stenotic lesion depends on a number of lesion characteristics, the physiological significance of coronary lesions of intermediate severity is often difficult to determine from angiography alone. This study of patients with coronary artery disease seeks to determine the relation between myocardial blood flow and flow reserve measured by positron emission tomography (PET) and the percent area stenosis on quantitative coronary arteriography. METHODS AND RESULTS: We studied 28 subjects: 18 patients with coronary artery disease (66 +/- 8 years) and 10 age-matched healthy volunteers (64 +/- 13 years) with dynamic N-13 ammonia PET imaging at rest and after dipyridamole (0.56 mg/kg). The percent cross-sectional area stenosis was quantified on the coronary arteriograms as described by Brown et al. In the 18 patients, a total of 41 non-infarct-related coronary vessels were analyzed. Myocardial blood flows in normal regions of patients with coronary artery disease were not different than those in healthy volunteers, both at rest and after dipyridamole. As a result, the myocardial flow reserve was also similar in both groups (2.4 +/- 0.4 versus 2.6 +/- 0.7, respectively; P = NS). Quantitative PET estimates of hyperemic blood flow (r = .81, P < .00001), flow reserve (r = .78, P < .00001), and an index of the "minimal coronary resistance" (r = .78, P < .00001) were inversely and nonlinearly correlated with the percent area stenosis on angiography. Of note, PET estimates of myocardial flow reserve successfully differentiated coronary lesions of intermediate severity (50% to 70% and 70% to 90%; 2.4 +/- 0.4 versus 1.8 +/- 0.5, respectively; P = .04). CONCLUSIONS: In patients with coronary artery disease, non-invasive measurements of myocardial blood flow and flow reserve by PET are inversely and nonlinearly related to stenosis severity as defined by quantitative angiography. Importantly, coronary lesions of intermediate severity have a differential flow reserve that decreases as stenosis increases that can be detected noninvasively by PET, thus allowing better definition of the functional importance of known coronary stenosis.


Assuntos
Angiografia Coronária/métodos , Circulação Coronária/fisiologia , Doença das Coronárias/fisiopatologia , Coração/diagnóstico por imagem , Tomografia Computadorizada de Emissão , Idoso , Amônia , Doença das Coronárias/diagnóstico por imagem , Vasos Coronários/patologia , Vasos Coronários/fisiopatologia , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Radioisótopos de Nitrogênio , Resistência Vascular/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA