Br J Haematol ; 175(4): 724-732, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27605462

RESUMO

Sickle cell disease (SCD) is a significant healthcare burden worldwide, but most affected individuals reside in low-resource areas where access to diagnostic testing may be limited. We developed and validated a rapid, inexpensive, disposable diagnostic test, the HemoTypeSC™ , based on novel monoclonal antibodies (MAbs) that differentiate normal adult haemoglobin (Hb A), sickle haemoglobin (Hb S) and haemoglobin C (Hb C). In competitive enzyme-linked immunosorbent assays, each MAb bound only its target with <0·1% cross-reactivity. With the HemoTypeSC™ test procedure, the sensitivity for each variant was <5·0 g/l. The accuracy of HemoTypeSC™ was evaluated on 100 whole blood samples from individuals with common relevant haemoglobin phenotypes, including normal (Hb AA, N = 20), carrier or trait (Hb AS, N = 22; Hb AC, N = 20), SCD (Hb SS, N = 22; Hb SC, N = 13), and Hb C disease (Hb CC, N = 3). The correct haemoglobin phenotype was identified in 100% of these samples. The accuracy of the test was not affected by Hb F (0-94·8% of total Hb) or Hb A2 (0-5·6% of total Hb). HemoTypeSC™ requires <1 µl of whole blood and no instruments or power sources. The total time-to-result is <20 min. HemoTypeSC™ may be a practical solution for point-of-care testing for SCD and carrier status in low-resource settings.


Assuntos
Anemia Falciforme/sangue , Anemia Falciforme/diagnóstico , Anticorpos Monoclonais , Testes Hematológicos/métodos , Sistemas Automatizados de Assistência Junto ao Leito , Animais , Diagnóstico Diferencial , Ensaio de Imunoadsorção Enzimática , Feminino , Testes Hematológicos/normas , Humanos , Camundongos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Traço Falciforme/sangue , Traço Falciforme/diagnóstico
2.
J Clin Microbiol ; 53(9): 2805-9, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26063858

RESUMO

Urinary tract infections (UTIs) are frequently encountered in clinical practice and most commonly caused by Escherichia coli and other Gram-negative uropathogens. We tested RapidBac, a rapid immunoassay for bacteriuria developed by Silver Lake Research Corporation (SLRC), compared with standard bacterial culture using 966 clean-catch urine specimens submitted to a clinical microbiology laboratory in an urban academic medical center. RapidBac was performed in accordance with instructions, providing a positive or negative result in 20 min. RapidBac identified as positive 245/285 (sensitivity 86%) samples with significant bacteriuria, defined as the presence of a Gram-negative uropathogen or Staphylococcus saprophyticus at ≥10(3) CFU/ml. The sensitivities for Gram-negative bacteriuria at ≥10(4) CFU/ml and ≥10(5) CFU/ml were 96% and 99%, respectively. The specificity of the test, detecting the absence of significant bacteriuria, was 94%. The sensitivity and specificity of RapidBac were similar on samples from inpatient and outpatient settings, from male and female patients, and across age groups from 18 to 89 years old, although specificity was higher in men (100%) compared with that in women (92%). The RapidBac test for bacteriuria may be effective as an aid in the point-of-care diagnosis of UTIs especially in emergency and primary care settings.


Assuntos
Bacteriúria/diagnóstico , Testes Diagnósticos de Rotina/métodos , Imunoensaio/métodos , Sistemas Automatizados de Assistência Junto ao Leito , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Escherichia coli/isolamento & purificação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade , Staphylococcus saprophyticus/isolamento & purificação , Fatores de Tempo , Adulto Jovem