Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
1.
Interv Neuroradiol ; : 15910199241252519, 2024 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-38715369

RESUMO

BACKGROUND: There have been immense advancements in the hardware and software of digital subtraction angiography systems over the last several years. These advancements continue to make progress toward the goals of offering better visualization and reducing radiation exposure. A newer advancement in this arena is presenting three-dimension data over time resulting in four-dimensional-digital subtracted angiography visualization. We have evaluated these protocols related to the evaluation of the treatment of intracranial aneurysms with pipeline flow diversion. METHODS: Four-dimensional-digital subtracted angiography imaging was acquired on an Artis Q Biplane angiographic system (Siemens Healthcare AG, Forchheim, Germany). A six second four-dimensional-digital subtracted angiography protocol was performed pre and post flow diverter placement. Pre and post reconstructed images were sent through a dedicated prototype research workstation (Syngo X-Workplace; Siemens Healthineers AG) for further flow evaluation. RESULTS: The treatment of an aneurysm with flow diversion led to a filling delay of 0.278 ± 0.422 s inside the aneurysms, whereas distal to the aneurysms the filling of the vessel segment occurred earlier post procedural (negative filling delay of -0.15 ± 0.31 s. The flow ratio inside the aneurysm decreased to 63.6 ± 23% of its pre-treatment value and distal to the aneurysm the flow remained substantially the same (flow ratio: 95.6 ± 0.29%). Data showed a relative filling delay of the aneurysm normalized to the distal vessel of 0.43 ± 0.36 s. The relative flow ratio of the aneurysm in comparison to the distal parent vessel was 72.2 ± 31%. CONCLUSIONS: Analysis of a four-dimensional-digital subtracted angiography acquisition allows assessment of the effects of flow diversion treatment on aneurysm hemodynamic parameters and shows a significant decrease in flow inside the aneurysm compared to the parent vessel distal to the aneurysm.

2.
J Stroke Cerebrovasc Dis ; 32(8): 107216, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37392484

RESUMO

OBJECTIVES: Dual-energy CT allows differentiation between blood and iodinated contrast. This study aims to determine the predictive value of contrast density and volume on post-thrombectomy dual-energy CT for delayed hemorrhagic transformation and its impact on 90-day outcomes. MATERIALS AND METHODS: A retrospective analysis was performed on patients who underwent thrombectomy for anterior circulation large-vessel occlusion at a comprehensive stroke center from 2018-2021. Per institutional protocol, all patients underwent dual-energy CT immediately post-thrombectomy and MRI or CT 24 hours afterward. The presence of hemorrhage and contrast staining was evaluated by dual-energy CT. Delayed hemorrhagic transformation was determined by 24-hour imaging and classified into petechial hemorrhage or parenchymal hematoma using ECASS III criteria. Univariable and multivariable analyses were performed to determine predictors and outcomes of delayed hemorrhagic transformation. RESULTS: Of 97 patients with contrast staining and without hemorrhage on dual-energy CT, 30 and 18 patients developed delayed petechial hemorrhage and delayed parenchymal hematoma, respectively. On multivariable analysis, delayed petechial hemorrhage was predicted by anticoagulant use (OR,3.53;p=0.021;95%CI,1.19-10.48) and maximum contrast density (OR,1.21;p=0.004;95%CI,1.06-1.37;per 10 HU increase), while delayed parenchymal hematoma was predicted by contrast volume (OR,1.37;p=0.023;95%CI,1.04-1.82;per 10 mL increase) and low-density lipoprotein (OR,0.97;p=0.043;95%CI,0.94-1.00;per 1 mg/dL increase). After adjusting for potential confounders, delayed parenchymal hematoma was associated with worse functional outcomes (OR,0.07;p=0.013;95%CI,0.01-0.58) and mortality (OR,7.83;p=0.008;95%CI,1.66-37.07), while delayed petechial hemorrhage was associated with neither. CONCLUSION: Contrast volume predicted delayed parenchymal hematoma, which was associated with worse functional outcomes and mortality. Contrast volume can serve as a useful predictor of delayed parenchymal hematoma following thrombectomy and may have implications for patient management.

3.
J Stroke Cerebrovasc Dis ; 32(8): 107217, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37392485

RESUMO

OBJECTIVES: Dual-energy CT allows differentiation between blood and iodinated contrast. We aimed to determine predictors of subarachnoid and intraparenchymal hemorrhage on dual-energy CT performed immediately post-thrombectomy and the impact of these hemorrhages on 90-day outcomes. MATERIALS AND METHODS: A retrospective analysis was performed on patients who underwent thrombectomy for anterior circulation large-vessel occlusion and subsequent dual-energy CT at a comprehensive stroke center from 2018-2021. The presence of contrast, subarachnoid hemorrhage, or intraparenchymal hemorrhage immediately post-thrombectomy was assessed by dual-energy CT. Univariable and multivariable analyses were performed to identify predictors of post-thrombectomy hemorrhages and 90-day outcomes. Patients with unknown 90-day mRS were excluded. RESULTS: Of 196 patients, subarachnoid hemorrhage was seen in 17, and intraparenchymal hemorrhage in 23 on dual-energy CT performed immediately post-thrombectomy. On multivariable analysis, subarachnoid hemorrhage was predicted by stent retriever use in the M2 segment of MCA (OR,4.64;p=0.017;95%CI,1.49-14.35) and the number of thrombectomy passes (OR,1.79;p=0.019;95%CI,1.09-2.94;per an additional pass), while intraparenchymal hemorrhage was predicted by preprocedural non-contrast CT-based ASPECTS (OR,8.66;p=0.049;95%CI,0.92-81.55;per 1 score decrease) and preprocedural systolic blood pressure (OR,5.10;p=0.037;95%CI,1.04-24.93;per 10 mmHg increase). After adjusting for potential confounders, intraparenchymal hemorrhage was associated with worse functional outcomes (OR,0.25;p=0.021;95%CI,0.07-0.82) and mortality (OR,4.30;p=0.023,95%CI,1.20-15.36), while subarachnoid hemorrhage was associated with neither. CONCLUSIONS: Intraparenchymal hemorrhage immediately post-thrombectomy was associated with worse functional outcomes and mortality and can be predicted by low ASPECTS and elevated preprocedural systolic blood pressure. Future studies focusing on management strategies for patients presenting with low ASPECTS or elevated blood pressure to prevent post-thrombectomy intraparenchymal hemorrhage are warranted.


Assuntos
Isquemia Encefálica , Acidente Vascular Cerebral , Hemorragia Subaracnóidea , Humanos , Hemorragia Subaracnóidea/diagnóstico por imagem , Hemorragia Subaracnóidea/etiologia , Hemorragia Subaracnóidea/cirurgia , Estudos Retrospectivos , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/cirurgia , Trombectomia/efeitos adversos , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Isquemia Encefálica/complicações
4.
Transl Stroke Res ; 2023 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-37195548

RESUMO

Cerebral blood volume mapping can characterize hemodynamic changes within brain tissue, particularly after stroke. This study aims to quantify blood volume changes in the perihematomal parenchyma and pericavity parenchyma after minimally invasive intracerebral hemorrhage evacuation (MIS for ICH). Thirty-two patients underwent MIS for ICH with pre- and post-operative CT imaging and intraoperative perfusion imaging (DynaCT PBV Neuro, Artis Q, Siemens). The pre-operative and post-operative CT scans were segmented using ITK-SNAP software to calculate hematoma volumes and to delineate the pericavity tissue. Helical CT segmentations were registered to cone beam CT data using elastix software. Mean blood volumes were computed inside subvolumes by dilating the segmentations at increasing distances from the lesion. Pre-operative perihematomal blood volumes and post-operative pericavity blood volumes (PBV) were compared. In 27 patients with complete imaging, post-operative PBV significantly increased within the 6-mm pericavity region after MIS for ICH. The mean relative PBV increased by 21.6 and 9.1% at 3 mm and 6 mm, respectively (P = 0.001 and 0.016, respectively). At the 9-mm pericavity region, there was a 2.83% increase in mean relative PBV, though no longer statistically significant. PBV analysis demonstrated a significant increase in pericavity cerebral blood volume after minimally invasive ICH evacuation to a distance of 6 mm from the border of the lesion.

5.
J Neuroimaging ; 33(3): 368-374, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36916873

RESUMO

BACKGROUND AND PURPOSE: The risk of symptomatic intracranial hemorrhage (ICH) approaches 5% despite mechanical thrombectomy (MT) efficacy for ischemic stroke secondary to large vessel occlusion. Flat-panel detector CT (FDCT) imaging with Syngo Dyna CT imaging (Siemens Medical Solutions, Malvern, PA) can be used immediately following MT to detect ICH. PURPOSE: To evaluate the accuracy and reliability of FDCT imaging with Dyna CT compared to conventional post-MT CT and MRI. METHODS: Head FDCT (20 second, 70 kV) was performed immediately following MT on 26 consecutive patients; postprocedural CT or MRI was obtained ∼24 hours later. Two blinded, independent neuroradiologists evaluated all imaging, identifying ICH, stroke, and presence of subarachnoid contrast. Cohen's κ statistic was used to assess interrater agreement for each imaging outcome and compared the FDCT to conventional imaging. RESULTS: FDCT for ICH demonstrated a strong degree of interrater reliability (κ = 0.896; 95% confidence interval [CI], 0.734-1.057). Negligible reliability was seen for ischemia determination on immediate post-MT FDCT (κ = 0.149; 95% CI, -0.243 to 0.541). ICH evaluation between FDCT and post-MT conventional CT revealed modest interrater reliability (κ = 0.432; 95% CI, -0.100 to 0.965), which did not reach statistical significance. There was no substantive reliability in the evaluation of ICH between FDCT and post-MT MRI (κ = 0.118, 95% CI, -0.345 to 0.580). CONCLUSION: FDCT, such as Dyna CT, immediately post-MT is a promising tool that can expedite the detection of ICH with a high degree of reliability, although the detection of ischemic parenchymal changes is limited.


Assuntos
Isquemia Encefálica , Acidente Vascular Cerebral , Humanos , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X/métodos , Hemorragias Intracranianas/diagnóstico por imagem , Hemorragias Intracranianas/etiologia , Trombectomia , Isquemia Encefálica/diagnóstico por imagem , Isquemia Encefálica/cirurgia , Estudos Retrospectivos , Resultado do Tratamento
6.
Interv Neuroradiol ; : 15910199231157462, 2023 Feb 14.
Artigo em Inglês | MEDLINE | ID: mdl-36788203

RESUMO

BACKGROUND: Management of large vessel occlusion (LVO) patients after thrombectomy is affected by the presence of intracranial hemorrhage (ICH) on post-procedure imaging. Differentiating contrast staining from hemorrhage on post-procedural imaging has been facilitated by dual-energy computed tomography (DECT), traditionally performed in dedicated computed tomography (CT) scanners with subsequent delays in treatment. We employed a novel method of DECT using the Siemens cone beam CT (DE-CBCT) in the angiography suite to evaluate for post-procedure ICH and contrast extravasation. METHODS: After endovascular treatment for LVO was performed and before the patient was removed from the operating table, DE-CBCT was performed using the Siemens Q-biplane system, with two separate 20-second CBCT scans at two energy levels: 70 keV (standard) and 125 keV with tin filtration (nonstandard). Post-procedurally, patients also underwent a standard DECT using Siemens SOMATOM Force CT scanner. Two independent reviewers blindly evaluated the DE-CBCT and DECT for hemorrhage and contrast extravasation. RESULTS: We successfully performed intra-procedural DE-CBCT in 10 subjects with no technical failure. The images were high-quality and subjectively useful to differentiate contrast from hemorrhage. The one hemorrhage seen on standard DECT was very small and clinically silent. The interrater reliability was 100% for both contrast and hemorrhage detection. CONCLUSION: We demonstrate that intra-procedural DE-CBCT after thrombectomy is feasible and provides clinically meaningful images. There was close agreement between findings on DE-CBCT and standard DECT. Our findings suggest that DE-CBCT could be used in the future to improve stroke thrombectomy patient workflow and to more efficiently guide the postoperative management of these patients.

7.
Ann Otol Rhinol Laryngol ; 131(11): 1287-1292, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34918575

RESUMO

OBJECTIVES: Congenital vascular lesions commonly present in the head and neck, and most are managed conservatively. Location and rapid growth, however, may necessitate surgical intervention. Endoscopic endonasal surgery (EES) in the pediatric population has emerged as a viable option in treating sinonasal and skull base lesions. Utilizing these techniques in newborns carries unique challenges. The objective of this report is to describe the successful use of direct intralesional embolization followed by endoscopic endonasal resection of a venous malformation in a postnatal patient. METHODS: We reviewed the case reported and reviewed the pertinent literature. RESULTS: A 6-week-old infant was found to have a large right-sided sinonasal lesion confirmed as a venous malformation. Rapid growth, impending orbital compromise, and potential long-term craniofacial abnormalities demanded the need for urgent surgical intervention. Risk of bleeding was mitigated with direct intralesional embolization. Immediately afterward, the patient underwent endoscopic endonasal resection of the lesion. EES in the very young presents multiple challenges both anatomically and behaviorally. A multidisciplinary approach lead to a successful outcome. CONCLUSION: We report a case of a 6-week-old infant, the youngest reported patient to the authors' knowledge, who successfully underwent direct intralesional embolization followed by endoscopic endonasal resection of a sinonasal vascular malformation. This report highlights the challenges of this technique in the very young and demonstrates it as a viable treatment strategy for sinonasal vascular anomalies in this population.


Assuntos
Neoplasias da Base do Crânio , Neoplasias Vasculares , Criança , Endoscopia/métodos , Humanos , Recém-Nascido , Imageamento por Ressonância Magnética , Base do Crânio/cirurgia , Neoplasias da Base do Crânio/cirurgia
8.
J Neurointerv Surg ; 14(5)2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-34635580

RESUMO

Evidence is growing to support minimally invasive surgical evacuation of intraparenchymal hematomas, particularly those with minimal residual hematoma volumes following evacuation. To maximize the potential for neurologic recovery, it is imperative that the trajectory for access to the hematoma minimizes disruption of normal parenchyma. Flat panel detector CT-based navigation and needle guidance software provides a platform that uses flat panel detector CT imaging obtained on the angiography table to aid reliable and safe access to the hematoma. In addition to providing a high degree of accuracy, this method also allows convenient and rapid re-imaging to assess navigation accuracy and the degree of hematoma evacuation prior to procedural completion. We provide a practical review of the syngo iGuide needle guidance software and the methodology for incorporating its use, and the software of other vendors, in a variety of minimally invasive methods for evacuation of intraparenchymal hematomas.


Assuntos
Hemorragia Cerebral , Hematoma , Hemorragia Cerebral/cirurgia , Hematoma/diagnóstico por imagem , Hematoma/cirurgia , Humanos , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Tomografia Computadorizada por Raios X/métodos , Resultado do Tratamento
9.
J Neurointerv Surg ; 12(5): 512-520, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32005760

RESUMO

Wide-necked bifurcation aneurysms (WNBAs) make up 26-36% of all brain aneurysms. Treatments for WNBAs pose unique challenges due to the need to preserve major bifurcation vessels while achieving a durable occlusion of the aneurysm. Intrasaccular flow disruption is an innovative technique for the treatment of WNBAs. The Woven EndoBridge (WEB) device is the only United States Food and Drug Administration approved intrasaccular flow disruption device. In this review article we discuss various aspects of treating WNBAs with the WEB device, including indications for use, aneurysm/device selection strategies, antiplatelet therapy requirement, procedural technique, potential complications and bailouts, and management strategies for residual/recurrent aneurysms after initial WEB treatment.


Assuntos
Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/métodos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/cirurgia , Stents Metálicos Autoexpansíveis , Embolização Terapêutica/instrumentação , Embolização Terapêutica/métodos , Feminino , Humanos , Masculino , Resultado do Tratamento
10.
Int J Pediatr Otorhinolaryngol ; 130: 109805, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31864085

RESUMO

OBJECTIVES/PURPOSE: 1. Understand three different techniques for embolization of juvenile nasal angiofibroma (JNA) and assess their combined efficacy. 2. Perform successful endoscopic intralesional embolization of highly vascular sinonasal neoplasms. METHODS: In this study, we present the case of a 10-year-old male patient diagnosed with juvenile nasal angiofibroma (JNA) who successfully underwent trimodal embolization and resection at a tertiary academic medical center after failed coil embolization in his home country. We examine the clinical details of the case and a review of pertinent literature. RESULTS: Preoperative embolization is common in the treatment of JNA, but there is little consensus as to the proper timeframe and techniques utilized. In our case, preoperative imaging revealed a vascular tumor with intracranial extension consistent with UPMC Stage V JNA. Diagnostic angiogram revealed significant arborization from the internal and external carotid systems. A trimodal embolization technique, utilizing transarterial, percutaneous, and direct endoscopic intralesional injection of n-Butyl Cyanoacrylate (n-BCA) was performed. A two-staged endoscopic and open resection was subsequently performed one week later with minimal blood loss. In our case, combining intralesional embolization with traditional transarterial techniques resulted in an improved operative field and a successful clinical result. CONCLUSION: Embolization of highly vascular sinonasal tumors with n-BCA is not limited to endovascular techniques, but can be safely combined with percutaneous and endoscopic intralesional embolization up to one week prior to surgical resection.


Assuntos
Angiofibroma/terapia , Embolização Terapêutica , Neoplasias Nasofaríngeas/terapia , Angiofibroma/diagnóstico por imagem , Angiofibroma/patologia , Angiografia , Criança , Endoscopia , Humanos , Masculino , Neoplasias Nasofaríngeas/diagnóstico por imagem , Neoplasias Nasofaríngeas/patologia
11.
Int J Comput Assist Radiol Surg ; 14(7): 1117-1126, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30977093

RESUMO

PURPOSE: 2D digital subtraction angiography (DSA) has become an important technique for interventional neuroradiology tasks, such as detection and subsequent treatment of aneurysms. In order to provide high-quality DSA images, usually undiluted contrast agent and a high X-ray dose are used. The iodinated contrast agent puts a burden on the patients' kidneys while the use of high-dose X-rays expose both patients and medical staff to a considerable amount of radiation. Unfortunately, reducing either the X-ray dose or the contrast agent concentration usually results in a sacrifice of image quality. MATERIALS AND METHODS: To denoise a frame, the proposed spatiotemporal denoising method utilizes the low-rank nature of a spatially aligned temporal sequence where variation is introduced by the flow of contrast agent through a vessel tree of interest. That is, a constrained weighted rank-1 approximation of the stack comprising the frame to be denoised and its temporal neighbors is computed where the weights are used to prevent the contribution of non-similar pixels toward the low-rank approximation. The method has been evaluated using a vascular flow phantom emulating cranial arteries into which contrast agent can be manually injected (Vascular Simulations Replicator, Vascular Simulations, Stony Brook NY, USA). For the evaluation, image sequences acquired at different dose levels as well as different contrast agent concentrations have been used. RESULTS: Qualitative and quantitative analyses have shown that with the proposed approach, the dose and the concentration of the contrast agent could both be reduced by about 75%, while maintaining the required image quality. Most importantly, it has been observed that the DSA images obtained using the proposed method have the closest resemblance to typical DSA images, i.e., they preserve the typical image characteristics best. CONCLUSION: Using the proposed denoising approach, it is possible to improve the image quality of low-dose DSA images. This improvement could enable both a reduction in contrast agent and radiation dose when acquiring DSA images, thereby benefiting patients as well as clinicians. Since the resulting images are free from artifacts and as the inherent characteristics of the images are also preserved, the proposed method seems to be well suited for clinical images as well.


Assuntos
Angiografia Digital/métodos , Processamento de Imagem Assistida por Computador/métodos , Imagens de Fantasmas , Artérias , Artefatos , Meios de Contraste , Humanos
12.
J Neurol Sci ; 401: 12-16, 2019 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-30991296

RESUMO

INTRODUCTION: Flat panel imaging for emergent large vessel occlusion can be acquired prior to mechanical thrombectomy (MT). In this study, we examined patients undergoing MT with computed tomography angiography (CTA) to determine agreement on the site of occlusion and CTA collateral score (CS). METHODS: Flat Panel CTA (FP-CTA) was acquired before MT. Time between CTA and FP-CTA acquisition, site of occlusion, and CS were reported. Significant CS change was defined as >2-point change, or any change to/from a malignant profile (CS = 0 to CS > 0, or vice versa). RESULTS: Eleven patients (mean age, 60.8 years; NIHSS, 17; 55.0% female) were included; IV tPA was administered to 7. Intra-reader occlusion site, dichotomous CS, and continuous CS correlation between CTA and FP-CTA were 96.6%, 90.0%, and 86.6%, respectively. Inter-reader correlation for occlusion site was 93% for CTA and 100% for FP-CTA; dichotomous CS correlation was 87% for both CTA and FP-CTA; correlation of continuous CS was 77% for CTA and 87% for FP-CTA. CONCLUSION: Standard CTA and FP-CTA have high intra and inter-reader correlation determining site of occlusion and CS in ELVO setting. This angiographic tool may have potential applications for both triage and patient selection.


Assuntos
Transtornos Cerebrovasculares/diagnóstico por imagem , Transtornos Cerebrovasculares/tratamento farmacológico , Circulação Colateral/fisiologia , Angiografia por Tomografia Computadorizada/métodos , Trombólise Mecânica/métodos , Idoso , Circulação Colateral/efeitos dos fármacos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Estudos Prospectivos
13.
Appl Spectrosc ; 67(10): 1200-4, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24067577

RESUMO

Nearly all circular dichroism (CD) and linear dichroism (LD) spectrometers use a photoelastic modulator (PEM) in which an optical element is stressed using a high-tension voltage (HT) signal to induce birefringence. The birefringence consequently produces a phase difference between perpendicular polarization states of light passing through the PEM that is appropriate to CD or LD measurements. However, even without external stress (i.e., at zero HT) the PEM exhibits an inherent static birefringence. This article discusses the characterization of the static birefringence inherent to a PEM and its effect on the measurement of CD and LD, as well as the development and implementation of a novel model that accommodates for the presence of static birefringence. The model is validated with CD and LD experiments using purely chiral or linearly structured molecules (camphorsulfonic acid and chrysazin).

14.
Appl Spectrosc ; 67(1): 40-8, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23317669

RESUMO

Both the voltage-induced and the inherent (static) birefringence of a photoelastic modulator (PEM) affect the phase difference between orthogonal components of light passing through the PEM. This phase difference determines the polarization state of the light and is essential for determining true circular and linear dichroism (CD and LD, respectively) spectroscopy. Presented here are a more complete theoretical model of CD and LD and a new technique to determine the phase difference and static birefringence of a PEM in CD and LD. The intensity of the light for various configurations of the analyzer is interpreted (by using Mueller matrices and Stokes parameters) to calibrate the voltage-induced phase difference and to characterize the static birefringence in the photoelastic modulator. The effects of the static birefringence as well as intermediate polarization states (between left- and right-circularly polarized light) on LD and CD are characterized. Appropriate adjustments to the voltage applied to the PEM in order to mitigate these effects are discussed. It is expected that the techniques presented here will have a broad impact on the calibration of CD and LD spectrometers.

15.
Appl Spectrosc ; 66(2): 180-7, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22449282

RESUMO

Circular dichroism (CD), defined as the difference in absorption between left and right circularly polarized light, is used to spectroscopically study the structures of chiral materials. In this article, various methodologies are presented for characterizing the performance of CD spectrometers to determine (1) experimental conditions for optimal data collection, (2) noise characteristics dependent on machine parameters, (3) the relative significance of spectral data as a function of detector gain, and (4) stray light and dark current as a function of wavelength. The results of case studies of two commercial CD spectrometers (specifically, Jasco J810 and J815) are described. The analyses show that the variation of CD signal is Poisson distributed and hence can be considered shot noise. Also, optimum scan parameters are established and a weighting function of CD data significance is produced so that wavelength-dependent gain (as determined by the high tension, HT, voltage applied to the photomultiplier tube, PMT, detector) can be accommodated. Lastly, the amount of stray light and dark current for the photomultiplier tube is determined. Though specific to the Jasco CD spectrometers characterized in this study, it is expected that all CD spectrometers exhibit similar behavior and the methodology described here can be usefully applied to characterize CD spectrometers independent of manufacturer.


Assuntos
Dicroísmo Circular/métodos , Razão Sinal-Ruído , Fótons , Distribuição de Poisson , Reprodutibilidade dos Testes , Processamento de Sinais Assistido por Computador , Estereoisomerismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA