RESUMO
BACKGROUND: Approaches targeting the sodium-glucose cotransporter (SGLT) could represent a promising future therapeutic strategy for numerous oncological and metabolic diseases. In this study, we evaluated the safety, biodistribution and radiation dosimetry of the glucose analogue positron emission tomography (PET) agent [18F] labeled alpha-methyl-4-deoxy-4-[18F]fluoro-D-glucopyranoside ([18F]Me4FDG) with high sodium-glucose cotransporter and low glucose transporter (GLUT) affinity. For this purpose, five healthy volunteers (1 man, 4 women) underwent multiple whole-body PET/computed tomography (CT) examinations starting with injection and up to 4 h after injection of averaged (2.4 ± 0.1) MBq/kg (range: 2.3-2.5 MBq/kg) administered activity. The PET/CT scans were conducted in 5 separate sessions, blood pressure and temperature were measured, and blood and urine samples were collected before the scans and one hour after injection to assess toxicity. Measurements of [18F]Me4FDG radioactivity in organs of interest were determined from the PET/CT scans at 5 time points. Internal dosimetry was performed on voxel level using a fast Monte Carlo approach. RESULTS: All studied volunteers could well tolerate the [18F]Me4FDG and no adverse event was reported. The calculated effective dose was (0.013 ± 0.003) mSv/MBq. The organs with the highest absorbed dose were the kidneys with 0.05 mSv/MBq per kidney. The brain showed almost no uptake. After 60 min, (12 ± 15) % of the administered dose was excreted into the bladder. CONCLUSION: Featuring an effective dose of only 0.013 ± 0.003 mSv/MBq and no occurrence of side effects, the glucose analogue [18F]Me4FDG seems to be a safe radio-tracer with a favorable biodistribution for PET imaging and also within several consecutive scans. TRIAL REGISTRATION NUMBER: NCT03557138, Registered 22 February 2017, https://ichgcp.net/clinical-trials-registry/NCT03557138 .
RESUMO
PURPOSE: Long axial field-of-view (LAFOV) positron emission tomography (PET) systems allow to image all major organs with one bed position, which is particularly useful for acquiring whole-body dynamic data using short-lived radioisotopes like 82Rb. METHODS: We determined the absorbed dose in target organs of three subjects (29, 40, and 57 years old) using two different methods, i.e., MIRD and voxel dosimetry. The subjects were injected with 407.0 to 419.61 MBq of [82Rb]Cl and were scanned dynamically for 7 min with a LAFOV PET/CT scanner. RESULTS: Using the MIRD formalism and voxel dosimetry, the absorbed dose ranged from 1.84 to 2.78 µGy/MBq (1.57 to 3.92 µGy/MBq for voxel dosimetry) for the heart wall, 2.76 to 5.73 µGy/MBq (3.22 to 5.37 µGy/MBq for voxel dosimetry) for the kidneys, and 0.94 to 1.88 µGy/MBq (0.98 to 1.92 µGy/MBq for voxel dosimetry) for the lungs. The total body effective dose lied between 0.50 and 0.76 µSv/MBq. CONCLUSION: Our study suggests that the radiation dose associated with [82Rb]Cl PET/CT can be assessed by means of dynamic LAFOV PET and that it is lower compared to literature values.
Assuntos
Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Radiometria , Radioisótopos de Rubídio , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Pessoa de Meia-Idade , Adulto , Radiometria/métodos , Masculino , Doses de Radiação , FemininoRESUMO
PURPOSE: Amyloid positron emission tomography (PET) with [18F]florbetaben (FBB) is an established tool for detecting Aß deposition in the brain in vivo based on visual assessment of PET scans. Quantitative measures are commonly used in the research context and allow continuous measurement of amyloid burden. The aim of this study was to demonstrate the robustness of FBB PET quantification. METHODS: This is a retrospective analysis of FBB PET images from 589 subjects. PET scans were quantified with 15 analytical methods using nine software packages (MIMneuro, Hermes BRASS, Neurocloud, Neurology Toolkit, statistical parametric mapping (SPM8), PMOD Neuro, CapAIBL, non-negative matrix factorization (NMF), AmyloidIQ) that used several metrics to estimate Aß load (SUVR, centiloid, amyloid load, and amyloid index). Six analytical methods reported centiloid (MIMneuro, standard centiloid, Neurology Toolkit, SPM8 (PET only), CapAIBL, NMF). All results were quality controlled. RESULTS: The mean sensitivity, specificity, and accuracy were 96.1 ± 1.6%, 96.9 ± 1.0%, and 96.4 ± 1.1%, respectively, for all quantitative methods tested when compared to histopathology, where available. The mean percentage of agreement between binary quantitative assessment across all 15 methods and visual majority assessment was 92.4 ± 1.5%. Assessments of reliability, correlation analyses, and comparisons across software packages showed excellent performance and consistent results between analytical methods. CONCLUSION: This study demonstrated that quantitative methods using both CE marked software and other widely available processing tools provided comparable results to visual assessments of FBB PET scans. Software quantification methods, such as centiloid analysis, can complement visual assessment of FBB PET images and could be used in the future for identification of early amyloid deposition, monitoring disease progression and treatment effectiveness.
Assuntos
Doença de Alzheimer , Peptídeos beta-Amiloides , Humanos , Peptídeos beta-Amiloides/metabolismo , Estudos Retrospectivos , Reprodutibilidade dos Testes , Processamento de Imagem Assistida por Computador/métodos , Encéfalo/metabolismo , Compostos de Anilina , Tomografia por Emissão de Pósitrons/métodos , Amiloide , Software , Doença de Alzheimer/diagnóstico por imagem , Doença de Alzheimer/patologiaRESUMO
PURPOSE: Selective internal radiation therapy (SIRT) is a treatment for various kinds of liver tumours by injecting 90Y bearing microspheres into the liver vessels. To perform meaningful post-treatment dosimetry, quantitative imaging is performed. METHODS: This work uses a Monte-Carlo based reconstruction software with scatter and attenuation correction and collimator modelling that allows the quantification of 90Y bremsstrahlung SPECT/CT data. A dataset comprising 17 patients and measurements on a Jaszczak phantom, a NEMA IEC Body phantom and an anthropomorphic liver phantom are analysed and activities and dose values are acquired. These measured values are compared with applied activities and pre-treatment calculations, allowing to assess the quality of the SPECT reconstruction. A detailed uncertainty budget is presented, including uncertainties of the dose calibrator, the count rate, non-included interactions and other factors. RESULTS: The applied method is validated by finding measurements repeatable within the given uncertainty, and it is shown the influence of various parameters on the reconstruction process is negligible. Furthermore, activities and doses measured in the phantoms show good agreement with calculated values, if they are corrected for partial volume effects. CONCLUSIONS: The strict observation of metrological requirements and the creation of an uncertainty budget increase the reliability and traceability of this novel approach to 90Y dosimetry. It gives an example of successful voxel-based dosimetry based on quantitative 90Y SPECT/CT image data.
Assuntos
Tomografia Computadorizada de Emissão de Fóton Único , Tomografia Computadorizada por Raios X , Humanos , Método de Monte Carlo , Imagens de Fantasmas , Reprodutibilidade dos TestesRESUMO
OBJECTIVE: To evaluate a home-built Java-based program (GFRcalc) to simplify the calculation of glomerular filtration rate (GFR) after administration of chromium-51 ethylenediaminetetraacetic acid (51Cr-EDTA) for routine clinical use. MATERIALS AND METHODS: In the program GFRcalc, the GFR was calculated based on the biological half-life of the 51Cr-EDTA concentration using the slope-intercept method of between two and five blood samples. Additional features included the ability to export patient data and generate clinical reports as well as to calculate the error of the fit of the GFR measurement in cases with three or more blood samples collected. The GFR was calculated from one, two and three blood samples of 133 patients with body surface-corrected GFR of 21-213 ml/min/1.73 m2. The Pearson correlation coefficient and the error of the fit for the GFR measurement were calculated for the three-sample method. RESULTS: The correlation coefficient for the three-sample method and the fit error correlated well for small fit errors; in case of fit errors >10%, the correlation coefficient partially differed in results compared to the other methods. The three-sample GFR values differed by approximately 17% from the single-sample GFRs. The fit errors of the three-sample GFRs correlated (r = 0.57) with their difference from the two-sample GFRs. CONCLUSION: In this study, the fit error that GFRcalc provided for the three-sample GFR offered a simple and reliable method to check the results obtained. This could also allow physicians to assess the reliability of the results and base their decisions on the quality of the measurement.
Assuntos
Confiabilidade dos Dados , Taxa de Filtração Glomerular , Software , Adolescente , Adulto , Idoso , Criança , Pré-Escolar , Cromo , Ácido Edético , Feminino , Humanos , Lactente , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Fatores de Tempo , Adulto JovemRESUMO
PURPOSE: Even though [(123)I]FP-CIT SPECT provides high accuracy in detecting nigrostriatal cell loss in neurodegenerative parkinsonian syndromes (PS), some patients with an inconclusive diagnosis remain. We investigated whether the diagnostic accuracy in patients with clinically uncertain PS with previously inconclusive findings can be improved by the use of iterative reconstruction algorithms and an improved semiquantitative evaluation which additionally implemented a correction algorithm for patient age and gamma camera dependency (EARL-BRASS; Hermes Medical Solutions, Sweden). METHODS: We identified 101 patients with inconclusive findings who underwent an [(123)I]FP-CIT SPECT between 2003 and 2010 as part of the diagnostic process of suspected PS at the University of Munich, and re-evaluated these scans using iterative reconstruction algorithms and the new corrected EARL-BRASS. Clinical follow-up was obtained in 62 out of the 101 patients and constituted the gold standard for the re-evaluation to assess the possible improvement in diagnostic accuracy. RESULTS: Clinical follow-up confirmed the diagnosis of PS in 11 of the 62 patients. In patients in whom both visual and semiquantitative analysis showed concordant findings (48 patients), a high negative predictive value (93 %), positive predictive value (100 %) and accuracy (94 %) were found, and thus a correct diagnosis was obtained in 45 of the 48 patients. Among the 14 patients with discordant findings, the additional semiquantitative analysis correctly identified all five of nine patients patients without PS by nonpathological semiquantitative findings in visually pathological or inconclusive scans. In contrast, four of the remaining five patients with decreased semiquantitative values but visually normal scans did not show a PS during follow-up. CONCLUSION: The age-corrected and camera-corrected mode of evaluation using EARL-BRASS provided a notable improvement in the diagnostic accuracy of [(123)I]FP-CIT SPECT in PS patients with previously inconclusive findings. The gain in accuracy might be achieved by better discrimination between physiological low striatal [(123)I]FP-CIT binding due to age-related loss of the dopamine transporter or pathological loss of binding.
Assuntos
Bases de Dados Factuais , Transtornos Parkinsonianos/diagnóstico por imagem , Tomografia Computadorizada de Emissão de Fóton Único , Tropanos , Incerteza , Estudos de Casos e Controles , Europa (Continente) , Feminino , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Sensibilidade e EspecificidadeRESUMO
PURPOSE: Apart from binding to the dopamine transporter (DAT), [(123)I]FP-CIT shows moderate affinity for the serotonin transporter (SERT), allowing imaging of both monoamine transporters in a single imaging session in different brain areas. The aim of this study was to systematically evaluate extrastriatal binding (predominantly due to SERT) and its age and gender dependencies in a large cohort of healthy controls. METHODS: SPECT data from 103 healthy controls with well-defined criteria of normality acquired at 13 different imaging centres were analysed for extrastriatal binding using volumes of interest analysis for the thalamus and the pons. Data were examined for gender and age effects as well as for potential influence of striatal DAT radiotracer binding. RESULTS: Thalamic binding was significantly higher than pons binding. Partial correlations showed an influence of putaminal DAT binding on measured binding in the thalamus but not on the pons. Data showed high interindividual variation in extrastriatal binding. Significant gender effects with 31 % higher binding in women than in men were observed in the thalamus, but not in the pons. An age dependency with a decline per decade (±standard error) of 8.2 ± 1.3 % for the thalamus and 6.8 ± 2.9 % for the pons was shown. CONCLUSION: The potential to evaluate extrastriatal predominant SERT binding in addition to the striatal DAT in a single imaging session was shown using a large database of [(123)I]FP-CIT scans in healthy controls. For both the thalamus and the pons, an age-related decline in radiotracer binding was observed. Gender effects were demonstrated for binding in the thalamus only. As a potential clinical application, the data could be used as a reference to estimate SERT occupancy in addition to nigrostriatal integrity when using [(123)I]FP-CIT for DAT imaging in patients treated with selective serotonin reuptake inhibitors.
Assuntos
Neostriado/diagnóstico por imagem , Ponte/diagnóstico por imagem , Compostos Radiofarmacêuticos/farmacocinética , Tálamo/diagnóstico por imagem , Tropanos/farmacocinética , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Proteínas da Membrana Plasmática de Transporte de Dopamina/metabolismo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Especificidade de Órgãos , Ligação Proteica , Proteínas da Membrana Plasmática de Transporte de Serotonina/metabolismo , Fatores Sexuais , Tomografia Computadorizada de Emissão de Fóton ÚnicoRESUMO
BACKGROUND: Internal dose assessment after radionuclide therapy is usually performed using home-made software packages. The dose assessment includes image registration, region-of-interest drawing, time-activity curve generation, and manual calculation of residence times followed by dose calculation with the OLINDA/MIRD software. The drawback of these methods is that several steps have to be performed using various software products possibly installed on different workstations. The aforementioned approaches are error-prone as well as difficult and time-consuming. In this article, we present a commercial software package that implements all the required dose calculation steps in 1 application, which greatly facilitates the internal dose assessment. METHODS AND RESULTS: The workflow of the newly developed software package "Hybrid Dosimetry" proceeds from automatic image registration to region-of-interest drawing, followed by time-activity curve fitting and dose calculation according to the MIRD method. The software is available online and can be run on independent computers using images in the common DICOM format. We used the package for internal dosimetry of 8 patients treated with Lu-DOTATATE and compared the results with manual dose calculation. CONCLUSIONS: The online software package presented is platform independent and allows fast dose calculations. The results obtained with the new package were in perfect agreement with manual methods.
Assuntos
Sistemas On-Line , Compostos Radiofarmacêuticos/uso terapêutico , Dosagem Radioterapêutica , Software , Relação Dose-Resposta à Radiação , Feminino , Humanos , Masculino , Pessoa de Meia-IdadeRESUMO
BACKGROUND: Experimental models are essential tools in the development and evaluation of novel treatment options, but the preclinical model of renal ischemia-reperfusion injury is limited to the retrieval of (very) early functional data, leaving the pivotal long-term outcome unknown. The present study applies technetium-99m-mercapto-acetyl-tri-glycine [99mTc-MAG3] scintigraphy for the longitudinal follow-up examination of long-term kidney function after renal ischemia-reperfusion injury. METHODS: Unilateral warm ischemia was induced in scid beige mice by vascular clamping of the kidney hilum for 40 min. 99mTc-MAG3 scintigraphy was performed prior to injury, 8 and 14 days post ischemia. The fractional uptake rate [FUR] was calculated from scintigraphy data as a measure of renal clearance. RESULTS: FUR demonstrated a significant functional impairment of the ischemic kidney 8 and 14 days after injury (P < 0.05 vs. baseline), while contralateral non-ischemic kidneys showed no significant changes. In histological analysis, ischemic kidneys exhibited tubular dilatation and cytoplasmic degeneration as signs of hypoxia without any evidence for necrosis. CONCLUSIONS: FUR enables the detection of renal dysfunction and longitudinal long-term follow-up examination in the same individual. Our model may facilitate preclinical therapy evaluation for the identification of effective renoprotective therapies.
RESUMO
BACKGROUND: The concept of acupuncture point localisation in Traditional Chinese Medicine (TCM) is based on millenary practical experience. Modern imaging methods such as PET, MRI and SPECT have been used primary for the investigation of the mechanisms of action of acupuncture. In this pilot single-case study we have evaluated the technical possibilities for in-vivo imaging of the anatomical relations of acupuncture points using state of the art MRI. METHODS: Preliminary experiments relating to the quality of acupuncture needles under the setting of MRI were done both with stainless steel and gold needles. In a second step, in-vivo imaging was carried out. A licensed acupuncture practitioner (RM) chose two points belonging to the so-called extraordinary vessels. In 2 sequential, separate procedures, he inserted himself gold acupuncture needles using a neutral technique (known as Ping Bu Ping Xie) into the Dai mai and Shen mai points, i.e. gall bladder 26 and bladder 62. Imaging was done on a Siemens Magnetom Avanto MR scanner using a head array and body coil. Mainly T1-weighted imaging sequences, as routinely used for patient exams, were used to obtain multi-slice images. RESULTS: In the preliminary experiments only acupuncture needles made of gold showed enough stability in order to be used for further imaging procedures. Using an onion and a banana as an object, further studies showed that the gold needles produced a void defect that corresponds to the tip of the inserted needle, while at the same time an artefactually increased diameter was observed. The in-vivo experiments showed that the Dai mai point was in relation to the abdominal internal oblique muscle. The Shen mai point artefact showed up close to the longus and brevis peroneal tendons at the fibular malleolus. Side effects related to heating or burning were not observed. Improved anatomical recognition was obtained using 3D-volume rendering techniques. CONCLUSION: Through an adequate choice of acupuncture material (gold needles) as well as of ideal MRI imaging sequences it has been possible to visualize the anatomical characteristics at the acupuncture points Dai mai and Shen mai in-vivo. At the selected sites the needles showed a relation to tendino-fascial and muscular structures. These anatomical structures fit well into the recently described WOMED concept of lateral tension in which these acupuncture points play a regulatory role.
Assuntos
Abdome/anatomia & histologia , Terapia por Acupuntura/métodos , Imageamento por Ressonância Magnética/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Projetos PilotoRESUMO
OBJECTIVES: Hashimoto's encephalitis is a term which describes encephalopathy associated with autoimmune thyroiditis, but it is not based on evidence, whether Hashimoto's encephalitis is a distinct clinical entity by itself. In previously reported cases of Hashimoto's encephalitis, abnormal brain perfusion studies have been reported. The aim of this study was to evaluate the prevalence of brain perfusion abnormalities in euthyroid patients with autoimmune thyroiditis. METHODS: 99mTc Ethyl cystein dimer (ECD) single photon emission computed tomography (SPECT) studies were performed in a study group of 41 euthyroid patients with autoimmune thyroiditis and a matched control group of 35 healthy individuals. All study participants had a normal neurological investigation and a detailed neurological history taking. Individuals with known or suspected morphological brain abnormalities were excluded from the study. Zung's Self-Rating Anxiety Scale (SAS) and Zung's Self-Rating Depression Scale (SDS) were used to detect depression and mood disorders. Automatic quantification of perfusion was performed with both a voxel-based analysis as well as a volume-of-interest (VOI) based analysis of 46 predefined cortical and subcortical regions. The findings from both groups were compared to a reference template. RESULTS: In the voxel-based analysis, there was a significant difference between patients and controls in the mean volume of perfusion defects deviating 2SD below the normal values (21.8 ml vs. 10.4 ml; P = 0.02). Hyperperfused areas, however, did not differ significantly between study patients and controls. A significant correlation of the perfusion defects with time since diagnosis of autoimmune thyroiditis was seen (r = 0.42). In the VOI-based analysis, abnormal regions were more frequent in the study group when compared to controls (P < 0.01) However, no topographic pattern was apparent. Regarding neurological findings, no significant difference was found between study patients and controls. However, both the SAS and SDS scores differed significantly between the two groups, but there was neither a correlation between the two scores and perfusion abnormalities nor an association with depression in our study group. CONCLUSIONS: These findings of impaired brain perfusion in patients with autoimmune thyroiditis further strengthen the hypothesis of a possible cerebral involvement in autoimmune thyroiditis in individual cases. The presence of cerebral hypoperfusion suggests a cerebral vasculitis as the most likely pathogenetic model.