Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Front Neurol ; 15: 1338899, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38333608

RESUMO

Introduction: Mononeuritis multiplex is frequently related to vasculitic neuropathy and has been reported only sporadically as an adverse event of immune checkpoint inhibitors. Methods: Case series of three patients with mononeuritis multiplex-all with mesothelioma-identified in the databases of two French clinical networks (French Reference Center for Paraneoplastic Neurological Syndromes, Lyon; OncoNeuroTox, Paris; January 2015-October 2022) set up to collect and investigate n-irAEs on a nationwide level. Results: Three patients (male; median age 86 years; range 72-88 years) had pleural mesothelioma and received 10, 4, and 6 cycles, respectively, of first-line nivolumab plus ipilimumab combined therapy. In patient 1, the neurological symptoms involved the median nerves, and in the other two patients, there was a more diffuse distribution; the symptoms were severe (common terminology criteria for adverse events, CTCAE grade 3) in all patients. Nerve conduction studies indicated mononeuritis multiplex in all patients. Peripheral nerve biopsy demonstrated necrotizing vasculitis in patients 1 and 3 and marked IgA deposition without inflammatory lesions in patient 2. Immune checkpoint inhibitors were permanently withdrawn, and corticosteroids were administered to all patients, leading to complete symptom regression (CTCAE grade 0, patient 2) or partial improvement (CTCAE grade 2, patients 1 and 3). During steroid tapering, patient 1 experienced symptom recurrence and spreading to other nerve territories (CTCAE grade 3); he improved 3 months after rituximab and cyclophosphamide administration. Discussion: We report the occurrence of mononeuritis multiplex, a very rare adverse event of immune checkpoint inhibitors, in the three patients with mesothelioma. Clinicians must be aware of this severe, yet treatable adverse event.

2.
Eur Radiol ; 29(12): 6762-6771, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31264015

RESUMO

PURPOSE: To assess whether virtual non-contrast (VNC) images derived from contrast dual-layer dual-energy computed tomography (DL-DECT) images could replace true non-contrast (TNC) images for aortic intramural hematoma (IMH) diagnosis in acute aortic syndrome (AAS) imaging protocols by performing quantitative as well as qualitative phantom and clinical studies. MATERIALS AND METHODS: Patients with confirmed IMH were included retrospectively in two centers. For in vitro imaging, a custom-made phantom of IMH was placed in a semi-anthropomorphic thorax phantom (QRM GmbH) and imaged on a DL-DECT at 120 kVp under various conditions of patient size, radiation exposure, and reconstruction modes. For in vivo imaging, 21 patients (70 ± 13 years) who underwent AAS imaging protocols at 120 kVp were included. In both studies, contrast-to-noise ratio (CNR) between hematoma and lumen was compared using a paired t test. Diagnostic confidence (1 = non-diagnostic, 4 = exemplary) for VNC and TNC images was rated by two radiologists and compared. Effective radiation doses for each acquisition were calculated. RESULTS: In both the phantom and clinical studies, we observed that the CNRs were similar between the VNC and TNC images. Moreover, both methods allowed differentiating the hyper-attenuation within the hematoma from the blood. Finally, we obtained equivalent high diagnostic confidence with both VNC and TNC images (VNC = 3.2 ± 0.7, TNC = 3.1 ± 0.7; p = 0.3). Finally, by suppressing TNC acquisition and using VNC, the mean effective dose reduction would be 40%. CONCLUSION: DL-DECT offers similar performances with VNC and TNC images for IMH diagnosis without compromise in diagnostic image quality. KEY POINTS: • Dual-layer dual-energy CT enables virtual non-contrast imaging from a contrast-enhanced acquisition. • Virtual non-contrast imaging with dual-layer dual-energy CT reduces the number of acquisitions and radiation exposure in acute aortic syndrome imaging protocol. • Dual-layer dual-energy CT has the potential to become a suitable imaging tool for acute aortic syndrome.


Assuntos
Doenças da Aorta/diagnóstico por imagem , Hematoma/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Idoso , Algoritmos , Feminino , Humanos , Técnicas In Vitro , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA