Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
1.
Eur Radiol ; 2024 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-38789792

RESUMO

BACKGROUND: The aim of our current systematic dynamic phantom study was first, to optimize reconstruction parameters of coronary CTA (CCTA) acquired on photon counting CT (PCCT) for coronary artery calcium (CAC) scoring, and second, to assess the feasibility of calculating CAC scores from CCTA, in comparison to reference calcium scoring CT (CSCT) scans. METHODS: In this phantom study, an artificial coronary artery was translated at velocities corresponding to 0, < 60, and 60-75 beats per minute (bpm) within an anthropomorphic phantom. The density of calcifications was 100 (very low), 200 (low), 400 (medium), and 800 (high) mgHA/cm3, respectively. CCTA was reconstructed with the following parameters: virtual non-iodine (VNI), with and without iterative reconstruction (QIR level 2, QIR off, respectively); kernels Qr36 and Qr44f; slice thickness/increment 3.0/1.5 mm and 0.4/0.2 mm. The agreement in risk group classification between CACCCTA and CACCSCT scoring was measured using Cohen weighted linear κ with 95% CI. RESULTS: For CCTA reconstructed with 0.4 mm slice thickness, calcium detectability was perfect (100%). At < 60 bpm, CACCCTA of low, and medium density calcification was underestimated by 53%, and 15%, respectively. However, CACCCTA was not significantly different from CACCSCT of very low, and high-density calcifications. The best risk agreement was achieved when CCTA was reconstructed with QIR off, Qr44f, and 0.4 mm slice thickness (κ = 0.762, 95% CI 0.671-0.853). CONCLUSION: In this dynamic phantom study, the detection of calcifications with different densities was excellent with CCTA on PCCT using thin-slice VNI reconstruction. Agatston scores were underestimated compared to CSCT but agreement in risk classification was substantial. CLINICAL RELEVANCE STATEMENT: Photon counting CT may enable the implementation of coronary artery calcium scoring from coronary CTA in daily clinical practice. KEY POINTS: Photon-counting CTA allows for excellent detectability of low-density calcifications at all heart rates. Coronary artery calcium scoring from coronary CTA acquired on photon counting CT is feasible, although improvement is needed. Adoption of the standard acquisition and reconstruction protocol for calcium scoring is needed for improved quantification of coronary artery calcium to fully employ the potential of photon counting CT.

2.
Eur Radiol ; 2024 Jan 04.
Artigo em Inglês | MEDLINE | ID: mdl-38175219

RESUMO

OBJECTIVES: Cardiac motion artifacts hinder the assessment of coronary arteries in coronary computed tomography angiography (CCTA). We investigated the impact of motion compensation reconstruction (MCR) on motion artifacts in CCTA at various heart rates (HR) using a dynamic phantom. MATERIALS AND METHODS: An artificial hollow coronary artery (5-mm diameter lumen) filled with iodinated contrast agent (400 HU at 120 kVp), positioned centrally in an anthropomorphic chest phantom, was scanned using a dual-layer spectral detector CT. The artery was translated at constant horizontal velocities (0-80 mm/s, increment of 10 mm/s). For each velocity, five CCTA scans were repeated using a clinical protocol. Motion artifacts were quantified using the in-plane motion area. Regression analysis was performed to calculate the reduction in motion artifacts provided by MCR, by division of the slopes of non-MCR and MCR fitted lines. RESULTS: Reference mean (95% confidence interval) motion artifact area was 24.9 mm2 (23.8, 26.0). Without MCR, motion artifact areas for velocities exceeding 20 mm/s were significantly larger (up to 57.2 mm2 (40.1, 74.2)) than the reference. With MCR, no significant differences compared to the reference were shown for all velocities, except for 70 mm/s (29.0 mm2 (27.0, 31.0)). The slopes of the fitted data were 0.44 and 0.04 for standard and MCR reconstructions, respectively, resulting in an 11-time motion artifact reduction. CONCLUSION: MCR may improve CCTA assessment in patients by reducing coronary artery motion artifacts, especially in those with elevated HR who cannot receive beta blockers or do not attain the targeted HR. CLINICAL RELEVANCE STATEMENT: This vendor-specific motion compensation reconstruction may improve coronary computed tomography angiography assessment in patients by reduction of coronary artery motion artifacts, especially in those with elevated various heart rates (HR) who cannot receive beta blockers or do not attain the targeted HR. KEY POINTS: • Motion artifacts are known to hinder the assessment of coronary arteries on coronary CT angiography (CCTA), leading to more non-diagnostic scans. • This dynamic phantom study shows that motion compensation reconstruction (MCR) reduces motion artifacts at various velocities, which may help to decrease the number of non-diagnostic scans. • MCR in this study showed to reduce motion artifacts 11-fold.

3.
Semin Nucl Med ; 2023 Aug 26.
Artigo em Inglês | MEDLINE | ID: mdl-37640631

RESUMO

Imaging water pathways in the human body provides an excellent way of measuring accurately the blood flow directed to different organs. This makes it a powerful diagnostic tool for a wide range of diseases that are related to perfusion and oxygenation. Although water PET has a long history, its true potential has not made it into regular clinical practice. The article highlights the potential of water PET in molecular imaging and suggests its prospective role in becoming an essential tool for the 21st century precision medicine in different domains ranging from preclinical to clinical research and practice. The recent technical advances in high-sensitivity PET imaging can play a key accelerating role in empowering this technique, though there are still several challenges to overcome.

4.
JACC Cardiovasc Imaging ; 16(12): 1552-1564, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37318394

RESUMO

BACKGROUND: Substantial variation in Agatston scores (AS) acquired with different computed tomography (CT) scanners may influence patient risk classification. OBJECTIVES: This study sought to develop a calibration tool for state-of-the-art CT systems resulting in vendor-neutral AS (vnAS), and to assess the impact of vnAS on coronary heart disease (CHD) event prediction. METHODS: The vnAS calibration tool was derived by imaging 2 anthropomorphic calcium containing phantoms on 7 different CT and 1 electron beam tomography system, which was used as the reference system. The effect of vnAS on CHD event prediction was analyzed with data from 3,181 participants from MESA (Multi-Ethnic Study on Atherosclerosis). Chi-square analysis was used to compare CHD event rates between low (vnAS <100) and high calcium groups (vnAS ≥100). Multivariable Cox proportional hazard regression models were used to assess the incremental value of vnAS. RESULTS: For all CT systems, a strong correlation with electron beam tomography-AS was found (R2 >0.932). Of the MESA participants originally in the low calcium group (n = 781), 85 (11%) participants were reclassified to a higher risk category based on the recalculated vnAS. For reclassified participants, the CHD event rate of 15% was significantly higher compared with participants in the low calcium group (7%; P = 0.008) with a CHD HR of 3.39 (95% CI: 1.82-6.35; P = 0.001). CONCLUSIONS: The authors developed a calibration tool that enables calculation of a vnAS. MESA participants who were reclassified to a higher calcium category by means of the vnAS experienced more CHD events, indicating improved risk categorization.


Assuntos
Aterosclerose , Doença da Artéria Coronariana , Calcificação Vascular , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Cálcio , Valor Preditivo dos Testes , Tomografia Computadorizada por Raios X , Fatores de Risco , Medição de Risco , Vasos Coronários/diagnóstico por imagem , Calcificação Vascular/diagnóstico por imagem
5.
Eur Radiol ; 33(7): 4668-4675, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36729174

RESUMO

PURPOSE: To systematically assess the radiation dose reduction potential of coronary artery calcium (CAC) assessments with photon-counting computed tomography (PCCT) by changing the tube potential for different patient sizes with a dynamic phantom. METHODS: A hollow artery, containing three calcifications of different densities, was translated at velocities corresponding to 0, < 60, 60-75, and > 75 beats per minute within an anthropomorphic phantom. Extension rings were used to simulate average- and large -sized patients. PCCT scans were made with the reference clinical protocol (tube potential of 120 kilovolt (kV)), and with 70, 90, Sn100, Sn140, and 140 kV at identical image quality levels. All acquisitions were reconstructed at a virtual monoenergetic energy level of 70 keV. For each calcification, Agatston scores and contrast-to-noise ratios (CNR) were determined, and compared to the reference with Wilcoxon signed-rank tests, with p < 0.05 indicating significant differences. RESULTS: A decrease in radiation dose (22%) was achieved at Sn100 kV for the average-sized phantom. For the large phantom, Sn100 and Sn140 kV resulted in a decrease in radiation doses of 19% and 3%, respectively. Irrespective of CAC density, Sn100 and 140 kVp did not result in significantly different CNR. Only at Sn100 kV were there no significant differences in Agatston scores for all CAC densities, heart rates, and phantom sizes. CONCLUSION: PCCT at tube voltage of 100 kV with added tin filtration and reconstructed at 70 keV enables a ≥ 19% dose reduction compared to 120 kV, independent of phantom size, CAC density, and heart rate. KEY POINTS: • Photon-counting CT allows for reduced radiation dose acquisitions (up to 19%) for coronary calcium assessment by reducing tube voltage while reconstructing at a normal monoE level of 70 keV. • Tube voltage reduction is possible for medium and large patient sizes, without affecting the Agatston score outcome.


Assuntos
Calcinose , Cálcio , Humanos , Vasos Coronários/diagnóstico por imagem , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Imagens de Fantasmas
6.
J Nucl Cardiol ; 30(1): 239-250, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-35708853

RESUMO

BACKGROUND: Coronary artery calcium is a well-known predictor of major adverse cardiac events and is usually scored manually from dedicated, ECG-triggered calcium scoring CT (CSCT) scans. In clinical practice, a myocardial perfusion PET scan is accompanied by a non-ECG triggered low dose CT (LDCT) scan. In this study, we investigated the accuracy of patients' cardiovascular risk categorisation based on manual, visual, and automatic AI calcium scoring using the LDCT scan. METHODS: We retrospectively enrolled 213 patients. Each patient received a 13N-ammonia PET scan, an LDCT scan, and a CSCT scan as the gold standard. All LDCT and CSCT scans were scored manually, visually, and automatically. For the manual scoring, we used vendor recommended software (Syngo.via, Siemens). For visual scoring a 6-points risk scale was used (0; 1-10; 11-100; 101-400; 401-100; > 1 000 Agatston score). The automatic scoring was performed with deep learning software (Syngo.via, Siemens). All manual and automatic Agatston scores were converted to the 6-point risk scale. Manual CSCT scoring was used as a reference. RESULTS: The agreement of manual and automatic LDCT scoring with the reference was low [weighted kappa 0.59 (95% CI 0.53-0.65); 0.50 (95% CI 0.44-0.56), respectively], but the agreement of visual LDCT scoring was strong [0.82 (95% CI 0.77-0.86)]. CONCLUSIONS: Compared with the gold standard manual CSCT scoring, visual LDCT scoring outperformed manual LDCT and automatic LDCT scoring.


Assuntos
Cálcio , Doença da Artéria Coronariana , Humanos , Amônia , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Vasos Coronários , Tomografia por Emissão de Pósitrons
7.
J Nucl Cardiol ; 29(4): 1686-1697, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-34350553

RESUMO

BACKGROUND: With the appearance of cadmium-zinc-telluride (CZT) cameras, dynamic myocardial perfusion imaging (MPI) has been introduced, but comparable data to other MPI modalities, such as quantitative coronary angiography (CAG) with fractional flow reserve (FFR) and positron emission tomography (PET), are lacking. This study aimed to evaluate the diagnostic accuracy of dynamic CZT single-photon emission tomography (SPECT) in coronary artery disease compared to quantitative CAG, FFR, and PET as reference. MATERIALS AND METHODS: Different databases were screened for eligible citations performing dynamic CZT-SPECT against CAG, FFR, or PET. PubMed, OvidSP (Medline), Web of Science, the Cochrane Library, and EMBASE were searched on the 5th of July 2020. Studies had to meet the following pre-established inclusion criteria: randomized controlled trials, retrospective trails or observational studies relevant for the diagnosis of coronary artery disease, and performing CZT-SPECT and within half a year the methodological references. Studies which considered coronary stenosis between 50% and 70% as significant based only on CAG were excluded. Data extracted were sensitivity, specificity, likelihood ratios, and diagnostic odds ratios. Quality was assessed with QUADAS-2 and statistical analysis was performed using a bivariate model. RESULTS: Based on our criteria, a total of 9 studies containing 421 patients were included. For the assessment of CZT-SPECT, the diagnostic value pooled analysis with a bivariate model was calculated and yielded a sensitivity of 0.79 (% CI 0.73 to 0.85) and a specificity of 0.85 (95% CI 0.74 to 0.92). Diagnostic odds ratio (DOR) was 17.82 (95% CI 8.80 to 36.08, P < 0.001). Positive likelihood ratio (PLR) and negative likelihood ratio (NLR) were 3.86 (95% CI 2.76 to 5.38, P < 0.001) and 0.21 (95% CI 0.13 to 0.33, P < 0.001), respectively. CONCLUSION: Based on the results of the current systematic review and meta-analysis, dynamic CZT-SPECT MPI demonstrated a good sensitivity and specificity to diagnose CAD as compared to the gold standards. However, due to the heterogeneity of the methodologies between the CZT-SPECT MPI studies and the relatively small number of included studies, it warrants further well-defined study protocols.


Assuntos
Doença da Artéria Coronariana , Reserva Fracionada de Fluxo Miocárdico , Imagem de Perfusão do Miocárdio , Cádmio , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Humanos , Imagem de Perfusão do Miocárdio/métodos , Estudos Retrospectivos , Telúrio , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Tomografia Computadorizada por Raios X , Zinco
8.
BMC Med Imaging ; 21(1): 151, 2021 10 19.
Artigo em Inglês | MEDLINE | ID: mdl-34666714

RESUMO

BACKGROUND: Motion artifacts affect the images of coronary calcified plaques. This study utilized convolutional neural networks (CNNs) to classify the motion-contaminated images of moving coronary calcified plaques and to determine the influential factors for the classification performance. METHODS: Two artificial coronary arteries containing four artificial plaques of different densities were placed on a robotic arm in an anthropomorphic thorax phantom. Each artery moved linearly at velocities ranging from 0 to 60 mm/s. CT examinations were performed with four state-of-the-art CT systems. All images were reconstructed with filtered back projection and at least three levels of iterative reconstruction. Each examination was performed at 100%, 80% and 40% radiation dose. Three deep CNN architectures were used for training the classification models. A five-fold cross-validation procedure was applied to validate the models. RESULTS: The accuracy of the CNN classification was 90.2 ± 3.1%, 90.6 ± 3.5%, and 90.1 ± 3.2% for the artificial plaques using Inception v3, ResNet101 and DenseNet201 CNN architectures, respectively. In the multivariate analysis, higher density and increasing velocity were significantly associated with higher classification accuracy (all P < 0.001). The classification accuracy in all three CNN architectures was not affected by CT system, radiation dose or image reconstruction method (all P > 0.05). CONCLUSIONS: The CNN achieved a high accuracy of 90% when classifying the motion-contaminated images into the actual category, regardless of different vendors, velocities, radiation doses, and reconstruction algorithms, which indicates the potential value of using a CNN to correct calcium scores.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Redes Neurais de Computação , Placa Aterosclerótica/classificação , Placa Aterosclerótica/diagnóstico por imagem , Robótica , Tomografia Computadorizada por Raios X , Artefatos , Movimento (Física) , Imagens de Fantasmas , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador
9.
Diagnostics (Basel) ; 11(7)2021 Jun 23.
Artigo em Inglês | MEDLINE | ID: mdl-34201889

RESUMO

Quantitative flow ratio (QFR) is a new opportunity to analyze functional stenosis during invasive coronary angiography. Together with a well-known intravascular ultrasound (IVUS) and a new player in the field, near-infrared spectroscopy (NIRS), it is gaining a lot of interest. The aim of the study was to compare QFR results with integrated IVUS-NIRS results acquired simultaneously in the same coronary lesion. We retrospectively enrolled 66 patients in whom 66 coronary lesions were assessed by NIRS-IVUS and QFR. Lesions were divided into two groups based on QFR results as QFR-positive group (QFR ≤ 0.8) or QFR-negative group (QFR > 0.8). Based on ROC curve analysis, the best cut-off values of minimal lumen area (MLA), minimal lumen diameter (MLD) and percent diameter stenosis for predicting QFR ≤ 80 were 2.4 (AUC 0.733, 95%CI 0.61, 0.834), 1.6 (AUC 0.768, 95%CI 0.634, 0.872) and 59.5 (AUC 0.918, 95%CI 0.824, 0.971), respectively. In QFR-positive lesions, the maxLCBI4mm was significantly higher than in QFR-negative lesions (450.12 ± 251.0 vs. 329.47 ± 191.14, p = 0.046). The major finding of the present study is that values of IVUS-MLA, IVUS-MLD and percent diameter stenosis show a good efficiency in predicting QFR ≤ 0.80. Moreover, QFR-positive lesions are characterized by higher maxLCBI4mm as compared to the QFR-negative group.

11.
Cardiol J ; 28(6): 887-895, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-31909469

RESUMO

BACKGROUND: Previous studies suggest that higher plasma concentrations of several lipid molecules are associated with higher lipid core burden index (LCBI) near infrared spectroscopy (NIRS) imaging. The aim of this study was to investigate whether an association between plasma lipids depends on plaque morphology (thin cap fibrous atheroma [TCFA] vs. non-TFCA) as measured by near-infrared spectroscopy-intravascular ultrasound (NIRS-IVUS). METHODS: Sixty-four patients retrospectively enrolled were diagnosed with stable coronary artery disease or acute coronary syndrome who underwent NIRS-IVUS imaging. Before percutaneous coronary intervention, blood samples were collected for measurement of serum levels of total cholesterol (TC), lowdensity lipoprotein cholesterol (HDL-C), high-density lipoprotein cholesterol (HDL-C) and triglycerides (TG). Patients were divided into two groups based on maxLCBI4mm and IVUS imaging. Those with maxLCBI4mm ≥ 323 were included into TCFA group (n = 35) while others were assigned to the non-TCFA group (n = 29). RESULTS: Thin cap fibrous atheroma lesions were significantly longer than the non-TCFA lesions (25.66 ± 9.56 vs. 17.03 ± 9.22, p = 0.001). TCFA characterizes greater plaque burden (78.4 [70.9, 82.2] vs. 72.70 [64.77, 76,05]; p = 0.021) and plaque volume (176.1 [110.75, 247.5] vs. 68.1 [55.58, 143.35]; p = 0.000) as compared to non-TCFA. In TCFA suspected lesions, there was no correlation between max-LCBI4mm and LDL levels (r = 0.105, p = 0.549) nor TC levels (r = -0.035, p = 0.844) but a negative correlation was found between HDL-C and maxLCBI4mm (r = -0.453, p = 0.007). CONCLUSIONS: The present study showed that there was no correlation between plasma LDL-C, TC and TG level and the amount of lipids in coronary plaque assessed by NIRS in both TCFA and non-TCFA groups. Only HDL-C correlated with maxLCBI4mm in TCFA lesions.


Assuntos
Doença da Artéria Coronariana , Placa Aterosclerótica , HDL-Colesterol , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Fibrose , Humanos , Placa Aterosclerótica/diagnóstico , Valor Preditivo dos Testes , Estudos Retrospectivos , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Ultrassonografia de Intervenção/métodos
12.
Diagnostics (Basel) ; 10(9)2020 Aug 24.
Artigo em Inglês | MEDLINE | ID: mdl-32846991

RESUMO

Transluminal attenuation gradient (TAG) represents the slope of intraluminal contrast that decreases along a coronary vessel during coronary computed tomography angiography (CCTA). The aim of this study was to determine the added value of TAG to qualitative CCTA assessment of significant stenosis (>50%) detecting ischemia as determined by stress myocardial blood flow (MBF) or myocardial flow reserve (MFR) measured by positron emission tomography (PET). Individual contributions of TAG, qualitative assessment and the impact of calcium score were also investigated. METHODS: We studied 38 consecutive patients that were referred due to suspected or known coronary artery disease (CAD). All patients underwent a two-phase hybrid 13N-ammonia PET/CT and CCTA. RESULTS: TAG and presence of qualitatively assessed significant stenosis, but not calcium score, were associated with stress myocardial blood flow (MBF) and myocardial flow reserve (MFR). The area under the curves (AUC) of the linear predictor model including qualitative assessment and TAG was superior to the AUC of separate qualitative assessment or TAG for the detection of ischemia according to stress MBF (AUCs were: 88% vs. 79% and 77%; p = 0.01 and p = 0.01, respectively). CONCLUSIONS: TAG combined with qualitative CCTA assessment improved ischemia detection.

14.
Cardiol J ; 27(3): 238-245, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-30246238

RESUMO

BACKGROUND: The composition of plaque impacts the results of stenting. The following study evaluated plaque redistribution related to stent implantation using combined near-infrared spectroscopy and intravascular ultrasound (NIRS-IVUS) imaging. METHODS: The present study included 49 patients (mean age 66 ± 11 years, 75% males) presenting with non-ST elevation myocardial infarction (8%), unstable angina (49%) and stable coronary artery disease (43%). The following parameters were analyzed: mean plaque volume (MPV, mm3), plaque burden (PB, %), remodeling index (RI), and maximal lipid core burden index in a 4 mm segment (maxLCBI4mm). High-lipid burden lesions (HLB) were defined as by maxLCBI4mm > 265 with positive RI. Otherwise plaques were defined as low-lipid burden lesions (LLB). Measurements were done in the target lesion and in 4 mm edges of the stent before and after stent implantation. RESULTS: MPV and maxLCBI4mm decreased in both HLB (MPV 144.70 [80.47, 274.25] vs. 97.60 [56.82, 223.45]; maxLCBI4mm: 564.11 ± 166.82 vs. 258.11 ± 234.24, p = 0.004) and LLB (MPV: 124.50 [68.00, 186.20] vs. 101.10 [67.87, 165.95]; maxLCBI4mm: 339.07 ± 268.22 vs. 124.60 ± 160.96, p < 0.001), but MPV decrease was greater in HLB (28.00 [22.60, 57.10] vs. 13.50 [1.50, 28.84], p = 0.019). Only at the proximal stent edge of LLB, maxLCBI4mm decreased (34 [0, 207] vs. 0 [0, 45], p = 0.049) and plaque burden increased (45.48 [40.34, 51.55] vs. 51.75 [47.48, 55.76], p = 0.030). CONCLUSIONS: NIRS-IVUS defined HLB characterized more significant decreases in plaque volume by stenting. Plaque redistribution to the proximal edge of the implanted stent occurred only in LLB.


Assuntos
Síndrome Coronariana Aguda/terapia , Angina Instável/terapia , Doença da Artéria Coronariana/terapia , Vasos Coronários/diagnóstico por imagem , Lipídeos/análise , Infarto do Miocárdio sem Supradesnível do Segmento ST/terapia , Intervenção Coronária Percutânea , Espectroscopia de Luz Próxima ao Infravermelho , Ultrassonografia de Intervenção , Síndrome Coronariana Aguda/diagnóstico por imagem , Síndrome Coronariana Aguda/metabolismo , Idoso , Angina Instável/diagnóstico por imagem , Angina Instável/metabolismo , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/metabolismo , Vasos Coronários/metabolismo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio sem Supradesnível do Segmento ST/diagnóstico por imagem , Infarto do Miocárdio sem Supradesnível do Segmento ST/metabolismo , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/instrumentação , Placa Aterosclerótica , Valor Preditivo dos Testes , Estudos Retrospectivos , Stents , Resultado do Tratamento
16.
Postepy Kardiol Interwencyjnej ; 15(2): 151-157, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31497047

RESUMO

INTRODUCTION: There are no data presenting a serial assessment of vein graft healing after bioresorbable vascular scaffold (BVS) implantation at long-term follow-up. AIM: To describe ABSORB BVS healing in vein grafts by optical coherence tomography (OCT) and high-definition intravascular imaging (HD-IVUS) at long-term follow-up.Material and methods: The study group consisted of 6 patients. The first patient had serial OCT assessment of BVS implanted in the saphenous vein grafts (SVG) at baseline and at 3-, 6-, 18-month follow-up and the second patient had OCT assessment of BVS implanted in the SVG at baseline and 24-, 48-month follow-up. The second and the third patients had OCT and HD-IVUS imaging at baseline and 48-month follow-up. The last 3 patients had OCT imaging of BVS implanted in the native coronary artery at 48-month follow-up. RESULTS: There were no differences in neointimal hyperplasia after BVS implantation between each time point. However, complete scaffold coverage was observed only 48 months after implantation. Out of 202 analyzed scaffold struts, there were 67 (33%) black boxes detectable at 48-month follow-up. HD-IVUS presented plaque burden up to 67% at the segment of BVS implantation at 48-months follow-up. There was a difference in neointimal hyperplasia thickness (1.27 (0.953-1.696) vs. 0.757 (0.633-0.848), p < 0.001) between a native coronary artery and BVS scaffolds at 48-month follow-up. CONCLUSIONS: Bioresorbable vascular scaffold implanted in SVG characterized moderate neointimal hyperplasia as excessive as compared to native coronary arteries at long-term follow-up. The complete scaffold coverage was observed only 48 months after implantation.

17.
J Sex Med ; 16(9): 1469-1477, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31326306

RESUMO

INTRODUCTION: Establishing the influence of long-term, gender-affirming hormonal treatment (HT) on bone mineral density (BMD) in transgender individuals is important to improve the therapeutic guidelines for these individuals. AIM: To examine the effect of long-term HT and gonadectomy on BMD in transgender individuals. METHODS: 68 transwomen and 43 transmen treated with HT who had undergone gonadectomy participated in this study. Dual-energy x-ray absorptiometry (DXA) scans were performed to measure BMD at the lumbar spine and total hip. Laboratory values related to sex hormones were collected within 3 months of performing the DXA scan and analyzed. MAIN OUTCOME MEASURE: BMD and levels of sex hormones in transwomen and transmen. RESULTS: In transwomen, the mean BMD values at the lumbar spine and total hip at the first DXA scan were, respectively, 0.99 ± 0.15 g/cm2 (n = 68) and 0.94 ± 0.28 g/cm2 (n = 65). In transmen, the mean BMD values at the lumbar spine and total hip at the first DXA scan were, respectively, 1.08 ± 0.16 g/cm2 (n = 43) and 1.01 ± 0.18 g/cm2 (n = 43). A significant decrease in total hip BMD was found in both transwomen and transmen after 15 years of HT compared with 10 years of HT (P = .02). CONCLUSION: In both transwomen and transmen, a decrease was observed in total hip bone mineral density after 15 years of HT compared to the first 10 years of HT. Dobrolinska M, van der Tuuk K, Vink P, et al. Bone Mineral Density in Transgender Individuals After Gonadectomy and Long-Term Gender-Affirming Hormonal Treatment. J Sex Med 2019; 16:1469-1477.


Assuntos
Densidade Óssea/fisiologia , Castração/efeitos adversos , Vértebras Lombares/patologia , Pessoas Transgênero , Absorciometria de Fóton , Adulto , Densidade Óssea/efeitos dos fármacos , Feminino , Terapia de Reposição Hormonal/efeitos adversos , Humanos , Masculino
18.
Postepy Kardiol Interwencyjnej ; 14(2): 157-166, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30008768

RESUMO

INTRODUCTION: Coronary artery bypass grafting (CABG), although widely used for a long time in diffuse coronary artery disease (CAD), has serious limitations associated with graft aging and its degeneration. AIM: The relationship between saphenous vein graft (SVG) plaque morphology assessed by optical coherence tomography (OCT) and clinical findings has not been elucidated yet. MATERIAL AND METHODS: We compared the morphology of SVG in stenotic vs. non-stenotic lesions using OCT imaging in 29 patients hospitalized in our center within the OCTOPUS registry. RESULTS: Stenotic lesions were characterized by higher incidence of thin-cap fibroatheroma (TCFA) (33% vs. 0%, p = 0.0048), thrombus (28% vs. 0%, p = 0.0008), lipid-rich plaque (LRP) (75% vs. 35%, p = 0.0013) and plaque within the SVG valve (19% vs. 0%, p = 0.0114) as compared to non-stenotic lesions. Patients with intimal tearing or rupture (ITR) were older (75.8% vs. 68.9 years, p = 0.047) and had lower left ventricular ejection fraction (LVEF) (32.0% vs. 49.7%, p = 0.001) and glomerular filtration rate (GFR) (36.0 vs. 73.6 ml/min/1.73 m2, p = 0.010). Patients with calcified lesions vs. those without had lower high-density lipoprotein (HDL) cholesterol (33.2 vs. 44.1 mg/dl, p = 0.018), similarly to those with ruptured plaque vs. those without (28.3 vs. 41.7 mg/dl, p = 0.047). CONCLUSIONS: Presence of ITR was associated with advanced age, decreased LVEF and renal insufficiency. Decreased concentration of HDL was associated with higher occurrence of calcified and ruptured plaque.

19.
Postepy Kardiol Interwencyjnej ; 14(4): 363-372, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30603026

RESUMO

INTRODUCTION: Coronary artery bypass grafting (CABG) is a method of choice in treatment of diffuse coronary artery disease (CAD), although it has some limitations such as late saphenous vein graft (SVG) patency loss, which occurs in one fifth of all conduits at 5 years. Since atherosclerosis in SVG has diffuse characteristics, it appears that significantly and non-significantly stenosed lesions may have an equal impact on worse prognosis. AIM: To assess non-significant lesions of SVG by the use of optical coherence tomography (OCT) and investigate the clinical and laboratory findings with the potential impact on plaque composition. MATERIAL AND METHODS: Twenty-nine patients with 43 non-significant lesions were enrolled in the study. All variables were assessed using uni- and multivariable logistic regression analysis with each plaque morphology as a dependent variable. Odds ratio (OR) and 95% confidence interval (CI) were computed. RESULTS: Plaque rupture (PRT) was independently associated with age (OR = 1.49, 95% CI: 1.09-2.04, p = 0.015) and lower rates of high-density lipoproteins (HDL) cholesterol (OR = 0.67, 95% CI: 0.49-0.92, p = 0.016). Intimal tearing or rupture (ITR) was related to reduced GFR (OR = 0.52, 95% CI: 0.38-0.72, p = 0.0004). Lipid-rich plaque (LRP) was associated with raised platelet count (PLT) (OR = 1.51, 95% CI: 1.16-1.96, p = 0.004) and increased frequency of smoking (OR = 1.45, 95% CI: 1.12-1.89, p = 0.007). CONCLUSIONS: Atherosclerosis of SVG is not restricted to significantly stenosed lesions. Plaque composition is independently associated with different types of clinical and laboratory findings, mostly recognized as risk factors of CAD.

20.
Circ J ; 80(8): 1804-11, 2016 Jul 25.
Artigo em Inglês | MEDLINE | ID: mdl-27334029

RESUMO

BACKGROUND: The OCTOPUS registry prospectively evaluates the procedural and long-term outcomes of saphenous vein graft (SVG) PCI. The current study assessed the morphology of de novo lesions and in-stent restenosis (ISR) in patients undergoing PCI of SVG. METHODS AND RESULTS: Optical coherence tomography (OCT) of SVG lesions in consecutive patients presenting with stable CAD and ACS was carried out. Thirty-nine patients (32 de novo and 10 ISR lesions) were included in the registry. ISR occurred in 5 BMS and 5 DES. There were no differences in the presence of plaque rupture and thrombus between de novo lesions and ISR. Lipid-rich tissue was identified in both de novo lesions and in ISR (75% vs. 50%, P=0.071) with a higher prevalence in BMS than in DES (23% vs. 7.5%; P=0.048). Calcific de novo lesions were detected in older grafts as compared with non-calcific atheromas (159±57 vs. 90±62 months after CABG, P=0.001). Heterogeneous neointima was found only in ISR (70% vs. 0, P<0.001) and was observed with similar frequency in both BMS and DES (24% vs. 30%, P=0.657). ISR was detected earlier in DES than BMS (median, 50 months; IQR, 18-96 months vs. 27 months; IQR, 13-29 months, P<0.001). CONCLUSIONS: OCT-based characteristics of de novo and ISR lesions in SVG were similar except for heterogeneous tissue, which was observed only in ISR. (Circ J 2016; 80: 1804-1811).


Assuntos
Oclusão de Enxerto Vascular , Intervenção Coronária Percutânea , Veia Safena/diagnóstico por imagem , Stents , Tomografia de Coerência Óptica , Idoso , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Feminino , Oclusão de Enxerto Vascular/diagnóstico por imagem , Oclusão de Enxerto Vascular/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Placa Aterosclerótica/diagnóstico por imagem , Placa Aterosclerótica/cirurgia , Estudos Prospectivos , Transplantes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA