1.
Int J Hyg Environ Health ; 256: 114298, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38056371

RESUMO

OBJECTIVES: Hexavalent chromium (Cr(VI)) is classified as a human carcinogen. Occupational Cr(VI) exposure can occur during different work processes, but the current exposure to Cr(VI) at Swedish workplaces is unknown. METHODS: This cross-sectional study (SafeChrom) recruited non-smoking men and women from 14 companies with potential Cr(VI) exposure (n = 113) and controls from 6 companies without Cr(VI) exposure (n = 72). Inhalable Cr(VI) was measured by personal air sampling (outside of respiratory protection) in exposed workers. Total Cr was measured in urine (pre- and post-shift, density-adjusted) and red blood cells (RBC) (reflecting Cr(VI)) in exposed workers and controls. The Bayesian tool Expostats was used to assess risk and evaluate occupational exposure limit (OEL) compliance. RESULTS: The exposed workers performed processing of metal products, steel production, welding, plating, and various chemical processes. The geometric mean concentration of inhalable Cr(VI) in exposed workers was 0.15 µg/m3 (95% confidence interval: 0.11-0.21). Eight of the 113 exposed workers (7%) exceeded the Swedish OEL of 5 µg/m3, and the Bayesian analysis estimated the share of OEL exceedances up to 19.6% for stainless steel welders. Median post-shift urinary (0.60 µg/L, 5th-95th percentile 0.10-3.20) and RBC concentrations (0.73 µg/L, 0.51-2.33) of Cr were significantly higher in the exposed group compared with the controls (urinary 0.10 µg/L, 0.06-0.56 and RBC 0.53 µg/L, 0.42-0.72). Inhalable Cr(VI) correlated with urinary Cr (rS = 0.64) and RBC-Cr (rS = 0.53). Workers within steel production showed the highest concentrations of inhalable, urinary and RBC Cr. Workers with inferred non-acceptable local exhaustion ventilation showed significantly higher inhalable Cr(VI), urinary and RBC Cr concentrations compared with those with inferred acceptable ventilation. Furthermore, workers with inferred correct use of respiratory protection were exposed to significantly higher concentrations of Cr(VI) in air and had higher levels of Cr in urine and RBC than those assessed with incorrect or no use. Based on the Swedish job-exposure-matrix, approximately 17 900 workers were estimated to be occupationally exposed to Cr(VI) today. CONCLUSIONS: Our study demonstrates that some workers in Sweden are exposed to high levels of the non-threshold carcinogen Cr(VI). Employers and workers seem aware of Cr(VI) exposure, but more efficient exposure control strategies are required. National strategies aligned with the European strategies are needed in order to eliminate this cause of occupational cancer.


Assuntos
Poluentes Ocupacionais do Ar , Exposição Ocupacional , Masculino , Humanos , Feminino , Poluentes Ocupacionais do Ar/análise , Suécia , Estudos Transversais , Teorema de Bayes , Monitoramento Ambiental , Cromo/urina , Exposição Ocupacional/análise , Aço Inoxidável/análise , Carcinógenos
2.
Biosens Bioelectron ; 75: 375-82, 2016 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-26342573

RESUMO

Wastewater samples from a Swedish chemi-thermo-mechanical pulp (CTMP) mill collected at different purification stages in a wastewater treatment plant (WWTP) were analyzed with an amperometric enzyme-based biosensor array in a flow-injection system. In order to resolve the complex composition of the wastewater, the array consists of several sensing elements which yield a multidimensional response. We used principal component analysis (PCA) to decompose the array's responses, and found that wastewater with different degrees of pollution can be differentiated. With the help of partial least squares regression (PLS-R), we could link the sensor responses to the Microtox® toxicity parameter, as well as to global organic pollution parameters (COD, BOD, and TOC). From investigating the influences of individual sensors in the array, it was found that the best models were in most cases obtained when all sensors in the array were included in the PLS-R model. We find that fast simultaneous determination of several global environmental parameters characterizing wastewaters is possible with this kind of biosensor array, in particular because of the link between the sensor responses and the biological effect onto the ecosystem into which the wastewater would be released. In conjunction with multivariate data analysis tools, there is strong potential to reduce the total time until a result is yielded from days to a few minutes.


Assuntos
Técnicas Biossensoriais , Monitoramento Ambiental , Poluentes Químicos da Água/isolamento & purificação , Águas Residuárias/química , Poluentes Químicos da Água/química
3.
Biosens Bioelectron ; 21(4): 608-17, 2005 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-16202874

RESUMO

Four wastewater samples of different treatment qualities; untreated, alarm, alert and normal, from a Swedish chemi-thermo-mechanical pulp mill and pure water were investigated using an amperometric bio-electronic tongue in a batch cell. The aim was to explore enzymatically modified screen-printed amperometric sensors for the discrimination of wastewater quality and to counteract the inherent drift. Seven out of eight platinum electrodes on the array were modified with four different enzymes; tyrosinase, horseradish peroxidase, acetyl cholinesterase and butyryl cholinesterase. At a constant potential the current intensity on each sensor was measured for 200s, 100s before injection and 100s after injection of the sample. The dynamic biosensor response curves from the eight sensors were used for principal component analysis (PCA). A simple baseline and sensitivity correction equivalent to multiplicative drift correction (MDC), using steady state intensities of reference sample (catechol) recordings, was employed. A clear pattern emerged in perfect agreement with prior knowledge of the samples explaining 97% of the variation in the data by two principal components (PCs). The first PC described the treatment quality of the samples and the second PC described the difference between treated and untreated samples. Horseradish peroxidase and pure platinum sensors were found to be the determinant sensors, while the rest did not contribute much to the discrimination. The wastewater samples were characterized by the chemical oxygen demand (COD), biological oxygen demand (BOD), total organic carbon (TOC), inhibition of nitrification, inhibition of respiration and toxicity towards Vibrio fischeri using Microtox, the freshwater alga Pseudokirchneriella subcapita and the freshwater crustacean Daphnia magna.


Assuntos
Técnicas Biossensoriais/instrumentação , Técnicas de Química Combinatória/métodos , Eletroquímica/instrumentação , Monitoramento Ambiental/instrumentação , Enzimas Imobilizadas/química , Resíduos Industriais/análise , Poluentes da Água/análise , Algoritmos , Técnicas Biossensoriais/métodos , Técnicas de Química Combinatória/instrumentação , Sistemas Computacionais , Eletroquímica/métodos , Monitoramento Ambiental/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Análise de Componente Principal , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
4.
Talanta ; 65(2): 298-305, 2005 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-18969799

RESUMO

In this paper, it is demonstrated that a single-receptor biosensor can be used to quantitatively determine each analyte in binary mixtures using multivariate data analysis tools based on the dynamic responses received from flow injection peaks. Mixtures with different concentrations of two phenolic compounds, catechol and 4-chlorophenol, were measured with a graphite electrode modified with tyrosinase enzyme at an applied potential of -50mV versus Ag/AgCl. A correction algorithm based on measurements of references in-between samples was applied to compensate for biosensor ageing as well as differences caused by deviations between biosensor preparations. After correction, the relative prediction errors with partial least squares regression (PLS-R) for catechol and 4-chlorophenol were 7.4 and 5.5%, respectively, using an analysis sequence measured on one biosensor. Additional validation mixtures of the two phenols were measured with a new biosensor, prepared with the same procedure but with a different batch of tyrosinase enzyme. Using the mixture responses for the first sensor as a calibration set in PLS-R, the relative prediction errors of the validation mixtures, after applying correction procedures, were 7.0% for catechol and 16.0% for 4-chlorophenol. These preliminary results indicate that by applying correction algorithms it could be possible to use less stable biosensors in continuous on-line measurements together with multivariate data analysis without time-consuming calibration procedures.

5.
Biosens Bioelectron ; 20(2): 176-83, 2004 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-15308219

RESUMO

Direct electron transfer (DET) was shown between the heme containing enzyme theophylline oxidase (ThO) and the surface of both graphite and gold electrodes. As proof on graphite a steady state current for theophylline was recorded using the electrode modified with adsorbed ThO. The electrode showed a Michaelis-Menten-like response to theophylline with a detection limit of 0.2 mM and a Michaelis-Menten constant equal to 3.2 mM. These initial results open up a possibility for the development of reagentless third generation biosensor based on heterogeneous DET between ThO and an electrode. On gold DET between ThO and the surface of aldrithiol modified gold was studied with spectroelectrochemical measurements. DET was observed for soluble ThO as a change of its spectrum in a gold capillary responding to a change in the applied potential. It was shown that the redox conversion of the heme domain of the enzyme is directly (mediatorlessly) driven by the potential applied at the gold electrode. The measurements enabled an estimation of the formal potential (E degrees ') of the redox process equal to -275 +/- 50 mV versus Ag|AgClsat at pH 7.0. The experimentally determined number of the electrons involved in this heterogeneous electron transfer process was estimated to be equal to 0.53. The low precision in determination of the E degrees ' and the value of the number of electrons lower than one indicate that kinetic restrictions disturbed the evaluation of the true thermodynamic values from relatively fast spectroelectrochemical measurements.


Assuntos
Técnicas Biossensoriais/métodos , Materiais Revestidos Biocompatíveis/química , Eletroquímica/métodos , Oxirredutases/análise , Oxirredutases/química , Teofilina/análise , Teofilina/química , Técnicas Biossensoriais/instrumentação , Eletroquímica/instrumentação , Transporte de Elétrons , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA