Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Biomedicines ; 12(3)2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38540297

RESUMO

BACKGROUND: Periodontitis and post-menopausal osteoporosis include common chronic bone disorders worldwide, with similar etiopathogenetic events. This study evaluated the effect of systemic melatonin administration on the alveolar bone destruction of periodontitis progression in an experimental periodontitis model in osteoporotic rats. METHODS: Forty-four Wistar rats were randomly divided into six experimental groups: control (C; n = 6); osteoporosis (O; n = 6); ligated periodontitis (LP; n = 8); osteoporosis- and periodontitis-induced (O+LP; n = 8); osteoporosis- and periodontitis-induced through 30 mg/kg/day melatonin administration (ML30; n = 8); and osteoporosis- and periodontitis-induced through 50 mg/kg/day melatonin administration (ML50; n = 8). The rats underwent bilateraloophorectomy and were maintained for 4 months to induce osteoporosis. After 4 months, 4-0 silk ligatures were placed submarginally around the mandibular first molar of each rat to induce experimental periodontitis, and melatonin was administered in the ML30 and ML50 groups for 30 days. Changes in alveolar bone levels were clinically measured, and tissues were histopathologically examined. RESULTS: Osteoclastic activity in the LP and O+LP groups was significantly higher than in the other groups (p < 0.05), but was similar in the C, O, and ML30 groups (p > 0.05). RANKL activity was the highest in the O+LP group, while melatonin decreased RANKL activity in the melatonin-administered groups (p < 0.05). Systemically administered melatonin significantly decreased alveolar bone loss in the ML30 and ML50 groups compared with that in the periodontitis groups (p < 0.05). CONCLUSIONS: Melatonin inhibited alveolar bone destruction by decreasing the RANKL expression and inflammatory cell infiltration and increased osteoblastic activity in a rat model with osteoporosis and periodontitis.

2.
Dent Traumatol ; 40(3): 251-265, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38234013

RESUMO

BACKGROUND/AIM: Thermoplastic mouthguards have been a reliable means of protection against impacts and shocks for a century. Although orofacial injuries are prevalent among basketball players, many athletes still avoid using mouthguards due to concerns regarding impaired breathing, speech interference, and nausea. This study aims to compare basketball players' subjective assessments of two different thicknesses of custom-made mouthguards (MGs) with boil-and-bite MGs (B&B MG). MATERIAL AND METHODS: A total of 60 systematically healthy male professional basketball players, without active orthodontic treatment, were enrolled and randomly assigned to three groups: Group 1 (received B&B MGs; n = 20), Group 2 (received custom-made MGs with a 3 mm thickness [ethyl vinyl asetat]; n = 20), and Group 3 (received custom-made MGs with a 5 mm thickness; n = 20). To evaluate MG comfort and usability, 12 key factors, including comfort, fit, stability, tiredness, thirsting, oral dryness, nausea, speaking, breathing, drinking, ease of wear and removal, and inclination to chew, were assessed. The athletes were made to rate these factors using a 10 cm-long Visual Analog Scale, measured at three-time intervals, and the values for both inter-group and intra-group were compared. RESULTS: Data from 48 basketball players were retrieved, and data analysis revealed that B&B MGs had the least favorable parameter values. Among the B&B MG group, stability was reported to be poorer during the initial measurement (p < .05). In the second measurement, B&B MGs showed significantly lower values for comfort, stability, tiredness, speaking, and inclination to chew (p < .05). During the third measurement, the B&B MG group exhibited significantly reduced values for comfort, breathing, drinking, and speaking (p < .05). In contrast, no statistically significant difference was observed between 3 and 5 mm thickness MGs in these measurements. CONCLUSIONS: Custom-made MGs with different thicknesses consistently outperformed B&B MGs in all measurements, indicating the potential to tailor MG thickness based on sport, age, professional level of athlete, and presence of other protective equipment. While custom-made mouthguards are considered the gold standard, dentists who provide B&B MGs can lead to cost savings while maintaining protection and encouraging athletes to use higher-quality custom-made mouthguards.


Assuntos
Basquetebol , Desenho de Equipamento , Protetores Bucais , Humanos , Masculino , Basquetebol/lesões , Adulto
3.
Lasers Med Sci ; 39(1): 48, 2024 Jan 27.
Artigo em Inglês | MEDLINE | ID: mdl-38279075

RESUMO

This study aimed to investigate the effects of 0.6% hyaluronic acid (HA) gel on the healing process and postoperative pain levels after diode laser-assisted labial frenectomy in pediatric patients. Ninety-six pediatric patients (females, 50 and males, 46) aged 8-14 years were randomly divided into four groups as follows: (1) conventional frenectomy with 0.6% topically administered HA (CFH, n = 24); (2) conventional frenectomy with placebo gel (CFP, n = 24); (3) frenectomy performed by diode laser with 0.6% topically administered HA (DLH, n = 24); and (4) frenectomy performed by diode laser with placebo gel (DLP, n = 24). HA application was continued for 1 week thrice daily after the frenectomy. Visual analog scale forms were collected from patients 1 week after the operation. In addition, the plaque index, gingival index, periodontal probing depth, and keratinized tissue width and thickness were recorded. This process was repeated 1 and 3 months after the first visit. The DLH group revealed significant differences in the probing depth, bleeding on probing, keratinized gingiva width, and attached gingiva width according to dual comparisons of the initial, first, and third-month values (p = 0.010, p = 0.007, p<0.001, and p = 0.001, respectively). Significant differences were observed between the CFP and CFH groups according to the initial and initial third-month values with regard to the bleeding on probing (p=0.019 and p = 0.019, respectively). The attached gingival thickness revealed significant differences between the CFP and CFH groups for the initial and initial-third-month comparisons (p = 0.005 and p = 0.007, respectively). The mean values of the initial and initial-third-month differences were significantly higher in the CFH group than those in the CFP group. HA- and laser-assisted labial frenectomies revealed better outcomes in terms of the probing depth, attached gingiva width, keratinized gingiva width, healing process, and postoperative comfort.


Assuntos
Arsenicais , Gálio , Ácido Hialurônico , Lasers Semicondutores , Masculino , Feminino , Humanos , Criança , Lasers Semicondutores/uso terapêutico , Índio , Frenectomia Oral , Gengiva
4.
J Clin Pediatr Dent ; 48(1): 171-183, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38239170

RESUMO

Fixed space maintainers (FSMs) are commonly utilized in pediatric dentistry to prevent space loss following premature tooth extraction. Although previous studies have examined the survival rates and causes of FSM failure, the impact of arm design on failure has not been investigated. This study aimed to investigate the tensile and compressive stresses related to FSMs with different arm designs and evaluate the effect of arm designs on FSM failure. Cone beam computed tomography images of a child who experienced premature loss of a primary mandibular left second molar tooth were retrieved from our database, then processed and simulated using the Rhinoceros software. Finite element analysis was performed to evaluate the stresses on four distinct FSM arm designs under simulated chewing forces. The results showed that the straight-arm FSM design exhibited the highest von Mises principal stress, while FSMs with curved arms and surrounding primary mandibular left first molar in the mesial area demonstrated the lowest von Mises stress accumulation. Intense stress accumulation on the distal surface of tooth 74 was observed in the test models due to the transmitted forces by the FSM. The maximum principal stresses accumulated at the base of the alveolar socket of the mesial root of tooth 36, while the minimum principal stresses were identified at the mesio-marginal area of the alveolar crest. The arm design played a crucial role in enabling the appliance to effectively withstand the stresses accumulating on the Space maintainer (SM) and orthodontic band. Bending the SM arms to match the surrounding profile with curvature increased the stress absorption capacity by increasing the arm length.


Assuntos
Mantenedor de Espaço em Ortodontia , Extração Dentária , Criança , Humanos , Análise de Elementos Finitos , Dente Molar/diagnóstico por imagem , Ligamento Periodontal , Estresse Mecânico , Mantenedor de Espaço em Ortodontia/instrumentação , Desenho de Equipamento
5.
Artigo em Inglês | MEDLINE | ID: mdl-37592845

RESUMO

Perianaesthetic dental trauma is a common anaesthesia-related complication. Theprevious studies have shown a lack of knowledge regarding mouthguard usage and controversial results related to perianaesthetic dental trauma prevention. This study aimed to conduct a finite element analysis of the compressive and tensile stresses on the tooth-periodontal ligament-bone complex using custom-made mouthguards of different thicknesses and glass fibre splints to prevent perianaesthetic dental trauma. Custom-fitted ethylene-vinyl acetate mouthguards of two different thicknesses (2 and 3 mm) and glass fibre splint were modelled. A linear static finite element analysis was performed by applying a rigid Macintosh laryngoscope to the palatal surface of the maxillary central incisors at 150 N. The model without a mouthguard and glass fibre splint showed the highest stress values at the palatinal root surfaces during the impact. Increasing the mouthguard thickness significantly decreased the stress-strain values regardless of the presence of the glass fibre splint. Maximum stresses in the group using the 3 mm mouthguard were the lowest compared with the other groups.

6.
Dent Traumatol ; 37(6): 786-794, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34216178

RESUMO

BACKGROUND/AIM: Peri-anesthetic dental trauma is a common anesthesia-related complication. It is the reason for a significant number of malpractice lawsuits against anesthetists through insurance companies. The frequency, outcomes, and risk factors related to peri-anesthetic dental trauma have been well documented. The aim of this study was to evaluate anesthetists' awareness, knowledge, and attitudes toward peri-anesthetic dental trauma. MATERIAL AND METHODS: This nationwide, cross-sectional, descriptive study comprising 220 anesthetists was conducted in Turkey between June 2019 and May 2020. A specific questionnaire was created using Google Forms and delivered to 591 participants via WhatsApp. Pearson's Chi-squared test and the Fisher-Freeman-Halton tests were used to analyze the results. RESULTS: The overall response rate was 37.2% (220 out of 591 participants). Of the 80.5% of the participants who encountered peri-anesthetic dental trauma during their practice, 32.8% had encountered avulsion and 32.8% reported that they had caused soft tissue injuries. More than one-third of the participants (38.9%) stated that the patient group that was the most at-risk for peri-anesthetic dental trauma was older people with missing teeth. Half of the participants (50.9%) stated that avulsed teeth could be replanted; among them, 21.8% and 11.8% specified that the ideal replantation time was <30 min and that the ideal storage medium for the avulsed tooth was fresh milk, respectively. Furthermore, 88.1% of the participants noted that peri-anesthetic dental trauma occurred more frequently during emergency intubations and only 20.9% were aware of custom-made mouthguards. CONCLUSIONS: Anesthetists lack knowledge around peri-anesthetic dental trauma and its interventions.


Assuntos
Anestésicos , Reimplante Dentário , Idoso , Anestesistas , Estudos Transversais , Conhecimentos, Atitudes e Prática em Saúde , Humanos
7.
J Obstet Gynaecol ; 39(8): 1075-1080, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31177888

RESUMO

The aim of this study was to determine the accuracy of the 24-h urine collection in preeclamptic pregnant women. This study included 65 singletons with preeclampsia and 53 singleton patients in a control-matched group. The ratio of inaccurate 24-h urine collection was measured by calculating expected urine creatinine excretion according to the proportion of pre-pregnancy weight and the lean body mass (LBM) of the patients. Comparisons were made between the accurately-collected 24-h urine protein excretion rates and the instant and 24-h urine protein/creatinine (P/Cr) and albumin/creatinine (A/Cr) ratios. Twenty-four-hour urine collection used to diagnose patients with preeclampsia was incorrectly collected 15-73.5% of the time among the patients and the control group. Instant and 24-h urine P/Cr and A/Cr ratios were correlated with total 24-h proteinuria among the patients in whom urine was collected correctly. Considering the 24-h urine P/Cr ratio, rather than the 24-h urine protein excretion value, is a better way to diagnose preeclampsia. IMPACT STATEMENT What is already known on this subject? Twenty-four-hour urine collection is considered as the gold standard of diagnosing proteinuria in preeclampsia, in case of the correctly collected. What do the results of this study add? Generally, in the literature the correctness of 24-h proteinuria is not questioned. However, it is actually quite important in daily practice to make the correct diagnosis of the proteinuria not to misdiagnose preeclampsia. What are the implications of these findings for clinical practice and/or further research? In this article, we aimed to show the importance of accurately collected 24-h urine in preeclampsia. We consider and advise to change the gold standard of this technique to 24-h protein/creatinine (P/Cr) ratio, in order to make correct diagnosis of the preeclampsia.


Assuntos
Albuminúria/urina , Creatinina/urina , Pré-Eclâmpsia/urina , Proteinúria/urina , Adulto , Feminino , Idade Gestacional , Humanos , Gravidez , Sensibilidade e Especificidade
8.
Srp Arh Celok Lek ; 144(5-6): 273-9, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-29648744

RESUMO

Introduction: Periodontitis is a chronic inflammatory and osteolytic disease. Vitamin B complex is a class of water-soluble vitamins that play important roles in cell metabolism. Objective: The aim of this study was to evaluate the effects of riboflavin (RBF), nicotinamide (NA), and folic acid (FA) on alveolar bone loss in experimental periodontitis rat model. Methods: Sixty-four male Wistar rats were randomly divided into the following eight groups: Control, Ligated, RBF50 (RBF, 50 mg/kg daily), NA50 (NA, 50 mg/kg daily), FA50 (FA, 50 mg/kg daily), RBF100 (RBF, 100 mg/kg daily), NA100 (NA, 100 mg/kg daily), and FA100 (FA, 100 mg/kg daily). Periodontitis was induced using silk ligature around the right first mandibular molar. After 11 days the rats were sacrificed. Mandible and serum samples were collected. Changes in alveolar bone levels were measured clinically, and periodontal tissues were examined histopathologically. Serum IL-1ß (pg/ml) levels were analyzed by using ELISA. Results: Mean alveolar bone loss in the mandibular first molar tooth revealed to be significantly lower in RBF100 group than in the Control group. In the Ligated group, alveolar bone loss was significantly higher than in all other groups. The ratio of presence of inflammatory cell infiltration in the Ligated group was significantly higher than in the Control group. The differences in the serum IL-1ß levels between the groups were not statistically significant. Osteoclasts that were observed in the Ligated group were significantly higher than those of the Control and FA100 groups. The osteoblastic activity in the Ligated group, RBF100, and NA100 groups were shown to be significantly higher than those in the Control group. Conclusion: This study has demonstrated that systemic administration of RBF, NA, and FA in different dosages (50­100 mg/kg) reduced alveolar bone loss in periodontal disease in rats.


Assuntos
Perda do Osso Alveolar/patologia , Ácido Fólico/farmacologia , Niacinamida/farmacologia , Periodontite/patologia , Riboflavina/farmacologia , Perda do Osso Alveolar/prevenção & controle , Animais , Modelos Animais de Doenças , Interleucina-1beta/sangue , Periodontite/tratamento farmacológico , Ratos Wistar
9.
J Pak Med Assoc ; 64(1): 79-81, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24605720

RESUMO

A case of unilateral absent ovary together with clear cell type epithelioid leiomyoma of uterus mimicking ovarian malignancy discovered during laparotomy is presented. Unilateral absence of an ovary is an extremely rare finding. Although the exact pathophysiological mechanism is not known, it could result from a defect in embryological development or asymptomatic torsion of ovary. Clear cell type epithelioid leiomyoma of uterus is also a rare variant, composed of round or polygonal 'clear' cells rather than typical spindle-shaped cells and ultra structurally differs from non-uterine counterparts.


Assuntos
Adenocarcinoma de Células Claras/diagnóstico , Leiomioma Epitelioide/diagnóstico , Neoplasias Ovarianas/diagnóstico , Ovário/anormalidades , Neoplasias Uterinas/diagnóstico , Adenocarcinoma de Células Claras/patologia , Feminino , Humanos , Leiomioma Epitelioide/patologia , Pessoa de Meia-Idade , Neoplasias Uterinas/patologia
10.
Mediators Inflamm ; 2013: 862982, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23606795

RESUMO

In vitro literature studies have suggested that atherosclerotic oxidized low density lipoprotein (OxLDL) inhibits trophoblast invasion. The objective of this study was to determine the levels of OxLDL and to examine the relationship between antioxidative estradiol, estriol, and prooxidative progestin in normal and preeclamptic placental tissues and measure the serum activity of antioxidative paraoxonase (PON1). The study included 30 preeclamptic and 32 normal pregnant women. OxLDL was determined with ELISA, estradiol, unconjugated estriol, and progesterone that were determined with chemiluminescence method in placental tissues. Serum PON1 activity was determined with spectrophotometric method. Levels of OxLDL (P = 0.027), estriol (P < 0.001), estradiol (P = 0.008), and progesterone (P = 0.009) were lower in the placental tissues of preeclamptic group compared to the normal pregnant women. Serum PON1 activity was higher in preeclamptic group (P = 0.040) and preeclamptic group without intrauterine growth restriction (P = 0.008) compared to normal pregnant women. Tissue estriol of preeclamptic group without/with IUGR (P < 0.001, P = 0.002) was lower than the normal group. Results of our study suggest that the events leading to fetoplacental insufficiency lead to a reduction in the levels of estriol limit deposition of OxLDL in placental tissues. The serum PON1 activity is probably important in the inhibition of OxLDL in preeclampsia.


Assuntos
Arildialquilfosfatase/sangue , Estrogênios/metabolismo , Lipoproteínas LDL/metabolismo , Placenta/metabolismo , Pré-Eclâmpsia/sangue , Progesterona/metabolismo , Adulto , Feminino , Humanos , Gravidez , Adulto Jovem
11.
Turk J Haematol ; 30(3): 341, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24385822
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA