Magn Reson Med ; 89(3): 937-950, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36352772

RESUMO

PURPOSE: The MP2RAGE sequence is typically optimized for either T1 -weighted uniform image (UNI) or gray matter-dominant fluid and white matter suppression (FLAWS) contrast images. Here, the purpose was to optimize an MP2RAGE protocol at 7 Tesla to provide UNI and FLAWS images simultaneously in a clinically applicable acquisition time at <0.7 mm isotropic resolution. METHODS: Using the extended phase graph formalism, the signal evolution of the MP2RAGE sequence was simulated incorporating T2 relaxation, diffusion, RF spoiling, and B1 + variability. Flip angles and TI were optimized at different TRs (TRMP2RAGE ) to produce an optimal contrast-to-noise ratio for UNI and FLAWS images. Simulation results were validated by comparison to MP2RAGE brain scans of 5 healthy subjects, and a final protocol at TRMP2RAGE  = 4000 ms was applied in 19 subjects aged 8-62 years with and without epilepsy. RESULTS: FLAWS contrast images could be obtained while maintaining >85% of the optimal UNI contrast-to-noise ratio. Using TI1 /TI2 /TRMP2RAGE of 650/2280/4000 ms, 6/8 partial Fourier in the inner phase-encoding direction, and GRAPPA factor = 4 in the other, images with 0.65 mm isotropic resolution were produced in <7.5 min. The contrast-to-noise ratio was around 20% smaller at TRMP2RAGE  = 4000 ms compared to that at TRMP2RAGE  = 5000 ms; however, the 20% shorter duration makes TRMP2RAGE  = 4000 ms a good candidate for clinical applications example, pediatrics. CONCLUSION: FLAWS and UNI images could be obtained in a single scan with 0.65 mm isotropic resolution, providing a set of high-contrast images and full brain coverage in a clinically applicable scan time. Images with excellent anatomical detail were demonstrated over a wide age range using the optimized parameter set.


Assuntos
Substância Branca , Humanos , Criança , Substância Branca/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Encéfalo/diagnóstico por imagem , Substância Cinzenta , Neuroimagem
2.
Front Radiol ; 3: 1327075, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38304343

RESUMO

Introduction: Ultra-high field MR imaging offers marked gains in signal-to-noise ratio, spatial resolution, and contrast which translate to improved pathological and anatomical sensitivity. These benefits are particularly relevant for the neonatal brain which is rapidly developing and sensitive to injury. However, experience of imaging neonates at 7T has been limited due to regulatory, safety, and practical considerations. We aimed to establish a program for safely acquiring high resolution and contrast brain images from neonates on a 7T system. Methods: Images were acquired from 35 neonates on 44 occasions (median age 39 + 6 postmenstrual weeks, range 33 + 4 to 52 + 6; median body weight 2.93 kg, range 1.57 to 5.3 kg) over a median time of 49 mins 30 s. Peripheral body temperature and physiological measures were recorded throughout scanning. Acquired sequences included T2 weighted (TSE), Actual Flip angle Imaging (AFI), functional MRI (BOLD EPI), susceptibility weighted imaging (SWI), and MR spectroscopy (STEAM). Results: There was no significant difference between temperature before and after scanning (p = 0.76) and image quality assessment compared favorably to state-of-the-art 3T acquisitions. Anatomical imaging demonstrated excellent sensitivity to structures which are typically hard to visualize at lower field strengths including the hippocampus, cerebellum, and vasculature. Images were also acquired with contrast mechanisms which are enhanced at ultra-high field including susceptibility weighted imaging, functional MRI, and MR spectroscopy. Discussion: We demonstrate safety and feasibility of imaging vulnerable neonates at ultra-high field and highlight the untapped potential for providing important new insights into brain development and pathological processes during this critical phase of early life.

3.
Front Pharmacol ; 12: 643492, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33959011

RESUMO

Background: An advanced stage, centrally localized invasive tumor is a major cause of sudden death in lung cancer patients. Currently, chemotherapy, radiotherapy, laser ablation, or surgical resection if possible are the available state-of-the-art treatments but none of these guarantee remedy or long-term relief and are often associated with fatal complications. Allowing localized chemotherapy, by direct and confined drug delivery only at the tumor site, could be a promising option for preoperative down staging or palliative therapy. Here we report the localized and targeted application of intra tumor delivery of chemotherapeutics using a novel device based on the principle of electrospray. Methods: C57BL/6J mice were injected with Lewis lung carcinoma cells subcutaneously. After 15 days, the animals were anesthetized and the tumors were exposed by skin incision. Tumors were electrosprayed with 100 µg cisplatin on days 0 and 2, and tumor volumes were measured daily. Animals were sacrificed on day 7 after the first electrospray and tumors were analyzed by immunohistochemistry. Results: In this proof-of-concept study, we report that the tumor volume was reduced by 81.2% (22.46 ± 12.14 mm3) after two electrospray mediated Cisplatin deliveries, while the control tumor growth, at the same time point, increased by 200% (514.30 ± 104.50 mm3). Moreover, tunnel and Caspase-3 positive cells were increased after Cisplatin electrospray compared to other experimental groups of animals. Conclusion: Targeted drug delivery by electrospray is efficient in the subcutaneous mouse model of lung cancer and offers a promising opportunity for further development toward its clinical application.

4.
NMR Biomed ; 32(5): e4049, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30697827

RESUMO

In order to acquire consistent k-space data in MR elastography, a fixed temporal relationship between the MRI sequence and the underlying period of the wave needs to be ensured. To this end, conventional GRE-MRE enforces synchronization through repeated triggering of the transducer and forcing the sequence repetition time to be equal to an integer multiple of the wave period. For wave frequencies below 100 Hz, however, this leads to prolonged acquisition times, as the repetition time scales inversely with frequency. A previously developed multi-shot approach (eXpresso MRE) to multi-slice GRE-MRE tackles this issue by acquiring an integer number of slices per wave period, which allows acquisition to be accelerated in typical scenarios by a factor of two or three. In this work, it is demonstrated that the constraints imposed by the eXpresso scheme are overly restrictive. We propose a generalization of the sequence in three steps by incorporating sequence delays into imaging shots and allowing for interleaved wave-phase acquisition. The Ristretto scheme is compared in terms of imaging shot and total scan duration relative to eXpresso and conventional GRE-MRE and is validated in three different phantom studies. First, the agreement of measured displacement fields in different stages of the sequence generalization is shown. Second, performance is compared for 25, 36, 40, and 60 Hz actuation frequencies. Third, the performance is assessed for the acquisition of different numbers of slices (13 to 17). In vivo feasibility is demonstrated in the liver and the breast. Here, Ristretto is compared with an optimized eXpresso sequence, leading to scan accelerations of 15% and 5%, respectively, without compromising displacement field and stiffness estimates in general. The Ristretto concept allows us to choose imaging shot durations on a fine grid independent of the number of slices and the wave frequency, permitting 2- to 4.5-fold acceleration of conventional GRE-MRE acquisitions.


Assuntos
Técnicas de Imagem por Elasticidade , Imageamento por Ressonância Magnética , Feminino , Humanos , Imagens de Fantasmas , Razão Sinal-Ruído , Fatores de Tempo
5.
Phys Med Biol ; 64(4): 045007, 2019 02 06.
Artigo em Inglês | MEDLINE | ID: mdl-30566925

RESUMO

BACKGROUND: Magnetic resonance elastography (MRE) is used to non-invasively estimate biomechanical tissue properties via the imaging of propagating mechanical shear waves. Several factors including mechanical transducer design, MRI sequence design and viscoelastic reconstruction influence data quality and hence the reliability of the derived biomechanical properties. PURPOSE: To design and characterize a novel mechanical MRE transducer concept based on a rotational eccentric mass, coined the gravitational transducer. MATERIALS AND METHODS: Table top measurements were performed using accelerometers to characterize the frequency response of the new transducer concept at different driving frequencies (f VIB) and different rotating masses. These were compared to a commercially available pneumatically driven MRE transducer. MR data were acquired on a 3T scanner using a fractionally encoded gradient echo MRE sequence in three healthy volunteers. Acceleration and displacement spectra were plotted in units of g and mm, respectively, and visually compared, emphasizing the ratio between the peaks at f VIB and its 2nd harmonic, a known cause of error in the reconstruction of biomechanical properties as is explored in more detail in numerical simulations here. No formal statistical testing was performed in this proof-of-principle paper. RESULTS: The new transducer concept shows-as expected from theory-a quadratic or linear increase of acceleration amplitude with increase in f VIB or mass, respectively. Furthermore, different versions of the transducer show markedly lower 2nd harmonic-to-f VIB ratios compared to the commercially available pneumatically driven transducer. Displacement was constant over a range of f VIB, in accordance with theory. Phantom and in vivo data show low nonlinearity and excellent data quality. CONCLUSION: The table top measurements are in concordance with the theory behind a transducer based on a rotational eccentric mass. The resulting constant displacement amplitude irrespective of f VIB and low 2nd harmonic-to-f VIB ratio result in low nonlinearity and high data fidelity in both phantom and in vivo examples.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Fígado/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Modelos Teóricos , Imagens de Fantasmas , Transdutores , Simulação por Computador , Gravitação , Voluntários Saudáveis , Humanos
6.
Am J Clin Nutr ; 105(3): 609-617, 2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-28100512

RESUMO

Background: Postexercise nutrition is paramount to the restoration of muscle energy stores by providing carbohydrate and fat as precursors of glycogen and intramyocellular lipid (IMCL) synthesis. Compared with glucose, fructose ingestion results in lower postprandial glucose and higher lactate and triglyceride concentrations. We hypothesized that these differences in substrate concentration would be associated with a different partition of energy stored as IMCLs or glycogen postexercise.Objective: The purpose of this study was to compare the effect of isocaloric liquid mixed meals containing fat, protein, and either fructose or glucose on the repletion of muscle energy stores over 24 h after a strenuous exercise session.Design: Eight male endurance athletes (mean ± SEM age: 29 ± 2 y; peak oxygen consumption: 66.8 ± 1.3 mL · kg-1 · min-1) were studied twice. On each occasion, muscle energy stores were first lowered by a combination of a 3-d controlled diet and prolonged exercise. After assessment of glycogen and IMCL concentrations in vastus muscles, subjects rested for 24 h and ingested mixed meals providing fat and protein together with 4.4 g/kg fructose (the fructose condition; FRU) or glucose (the glucose condition; GLU). Postprandial metabolism was assessed over 6 h, and glycogen and IMCL concentrations were measured again after 24 h. Finally, energy metabolism was evaluated during a subsequent exercise session.Results: FRU and GLU resulted in similar IMCL [+2.4 ± 0.4 compared with +2.0 ± 0.6 mmol · kg-1 wet weight · d-1; time × condition (mixed-model analysis): P = 0.45] and muscle glycogen (+10.9 ± 0.9 compared with +12.3 ± 1.9 mmol · kg-1 wet weight · d-1; time × condition: P = 0.45) repletion. Fructose consumption in FRU increased postprandial net carbohydrate oxidation and decreased net carbohydrate storage (estimating total, muscle, and liver glycogen synthesis) compared with GLU (+117 ± 9 compared with +135 ± 9 g/6 h, respectively; P < 0.01). Compared with GLU, FRU also resulted in lower plasma glucose concentrations and decreased exercise performance the next day.Conclusions: Mixed meals containing fat, protein, and either fructose or glucose elicit similar repletion of IMCLs and muscle glycogen. Under such conditions, fructose lowers whole-body glycogen synthesis and impairs subsequent exercise performance, presumably because of lower hepatic glycogen stores. This trial was registered at clinicaltrials.gov as NCT01866215.


Assuntos
Dieta , Metabolismo Energético , Exercício Físico/fisiologia , Frutose/farmacologia , Glucose/farmacologia , Glicogênio/metabolismo , Músculo Esquelético/efeitos dos fármacos , Adulto , Metabolismo dos Carboidratos , Carboidratos da Dieta/metabolismo , Carboidratos da Dieta/farmacologia , Gorduras na Dieta/metabolismo , Proteínas Alimentares/metabolismo , Frutose/metabolismo , Glucose/metabolismo , Humanos , Metabolismo dos Lipídeos/efeitos dos fármacos , Fígado/efeitos dos fármacos , Fígado/metabolismo , Masculino , Refeições , Músculo Esquelético/metabolismo , Oxirredução , Resistência Física/fisiologia , Fenômenos Fisiológicos da Nutrição Esportiva
7.
NMR Biomed ; 29(6): 796-805, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-27074205

RESUMO

Glycogen is a major substrate in energy metabolism and particularly important to prevent hypoglycemia in pathologies of glucose homeostasis such as type 1 diabetes mellitus (T1DM). (13) C-MRS is increasingly used to determine glycogen in skeletal muscle and liver non-invasively; however, the low signal-to-noise ratio leads to long acquisition times, particularly when glycogen levels are determined before and after interventions. In order to ease the requirements for the subjects and to avoid systematic effects of the lengthy examination, we evaluated if a standardized preparation period would allow us to shift the baseline (pre-intervention) experiments to a preceding day. Based on natural abundance (13) C-MRS on a clinical 3 T MR system the present study investigated the test-retest reliability of glycogen measurements in patients with T1DM and matched controls (n = 10 each group) in quadriceps muscle and liver. Prior to the MR examination, participants followed a standardized diet and avoided strenuous exercise for two days. The average coefficient of variation (CV) of myocellular glycogen levels was 9.7% in patients with T1DM compared with 6.6% in controls after a 2 week period, while hepatic glycogen variability was 13.3% in patients with T1DM and 14.6% in controls. For comparison, a single-session test-retest variability in four healthy volunteers resulted in 9.5% for skeletal muscle and 14.3% for liver. Glycogen levels in muscle and liver were not statistically different between test and retest, except for hepatic glycogen, which decreased in T1DM patients in the retest examination, but without an increase of the group distribution. Since the CVs of glycogen levels determined in a "single session" versus "within weeks" are comparable, we conclude that the major source of uncertainty is the methodological error and that physiological variations can be minimized by a pre-study standardization. For hepatic glycogen examinations, familiarization sessions (MR and potentially strenuous interventions) are recommended. Copyright © 2016 John Wiley & Sons, Ltd.


Assuntos
Algoritmos , Espectroscopia de Ressonância Magnética Nuclear de Carbono-13/métodos , Diabetes Mellitus Tipo 1/metabolismo , Glicogênio/metabolismo , Fígado/metabolismo , Músculo Esquelético/metabolismo , Adulto , Humanos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
8.
Magn Reson Med ; 75(5): 1867-74, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26185908

RESUMO

PURPOSE: To reliably determine the amplitude of the transmit radiofrequency ( B1+) field in moving organs like the liver and heart, where most current techniques are usually not feasible. METHODS: B1+ field measurement based on the Bloch-Siegert shift induced by a pair of Fermi pulses in a double-triggered modified Point RESolved Spectroscopy (PRESS) sequence with motion-compensated crusher gradients has been developed. Performance of the sequence was tested in moving phantoms and in muscle, liver, and heart of six healthy volunteers each, using different arrangements of transmit/receive coils. RESULTS: B1+ determination in a moving phantom was almost independent of type and amplitude of the motion and agreed well with theory. In vivo, repeated measurements led to very small coefficients of variance (CV) if the amplitude of the Fermi pulse was chosen above an appropriate level (CV in muscle 0.6%, liver 1.6%, heart 2.3% with moderate amplitude of the Fermi pulses and 1.2% with stronger Fermi pulses). CONCLUSION: The proposed sequence shows a very robust determination of B1+ in a single voxel even under challenging conditions (transmission with a surface coil or measurements in the heart without breath-hold).


Assuntos
Coração/fisiologia , Espectroscopia de Ressonância Magnética , Adulto , Eletrocardiografia , Feminino , Voluntários Saudáveis , Humanos , Processamento de Imagem Assistida por Computador/métodos , Fígado/fisiologia , Masculino , Modelos Estatísticos , Movimento , Músculos/fisiologia , Imagens de Fantasmas , Ondas de Rádio , Reprodutibilidade dos Testes , Adulto Jovem