1.
Int J Mol Sci ; 25(5)2024 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-38473945

RESUMO

A reversed-phase high-performance liquid chromatographic (HPLC) method was developed for the simultaneous determination of the potential impurities of dexketoprofen, including the distomer R-ketoprofen. After screening the separation capability of four polysaccharide columns (Lux Amylose-1, Lux Amylose-2, Lux Cellulose-1 and Lux Cellulose-2) in polar organic and in reversed-phase modes, appropriate enantioseparation was observed only on the Lux Amylose-2 column in an acidified acetonitrile/water mixture. A detailed investigation of the mobile phase composition and temperature for enantio- and chemoselectivity showed many unexpected observations. It was observed that both the resolution and the enantiomer elution order can be fine-tuned by varying the temperature and mobile phase composition. Moreover, hysteresis of the retention times and enantioselectivity was also observed in reversed-phase mode using methanol/water mixtures on amylose-type columns. This could indicate that the three-dimensional structure of the amylose column can change by transitioning from a polar organic to a reversed-phase mode, which affects the enantioseparation process. Temperature-dependent enantiomer elution order and rare enthalpic/entropic controlled enantioseparation in the operative temperature range were also observed in reversed-phase mode. To find the best methodological conditions for the determination of dexketoprofen impurities, a full factorial optimization design was performed. Using the optimized parameters (Lux Amylose-2 column with water/acetonitrile/acetic acid 50/50/0.1 (v/v/v) at a 1 mL/min flow rate at 20 °C), baseline separations were achieved between all compounds within 15 min. Our newly developed HPLC method was validated according to the current guidelines, and its application was tested on commercially available pharmaceutical formulations. According to the authors' knowledge, this is the first study to report hysteretic behavior on polysaccharide columns in reversed-phase mode.


Assuntos
Amilose , Cromatografia de Fase Reversa , Cetoprofeno/análogos & derivados , Trometamina , Amilose/química , Temperatura , Polissacarídeos/química , Celulose/química , Cromatografia Líquida de Alta Pressão/métodos , Água , Acetonitrilas , Estereoisomerismo
2.
Sci Rep ; 13(1): 14778, 2023 Sep 07.
Artigo em Inglês | MEDLINE | ID: mdl-37679395

RESUMO

The chiral separation capability of Chiral-CD-Ph column, containing phenylcarbamate-ß-cyclodextrin as the chiral selector in polar organic mode was investigated. A total of twenty-five compounds with different structures and acid-base properties were evaluated, and twenty of them were separated using acetonitrile or methanol as eluent. The effects of various chromatographic parameters, such as the type and proportion of organic modifier, flow rate, and column temperature were analyzed in detail in relation to chromatographic performance. A U-shape retention curve was observed when a mixture of acetonitrile and methanol was used as the eluent, indicating different types of interactions in different solvent mixtures. Van 't Hoff analysis was used for calculation of thermodynamic parameters which revealed that the enantioseparation is mainly enthalpy controlled; however, entropic control was also observed. The enantiomer recognition ability at the atomic level was also investigated through a molecular docking study, which revealed surface binding in polar organic mode instead of inclusion complexation. Our work proves that the phenylcarbamate-ß-cyclodextrin-based chiral stationary phase can be effectively used in polar organic mode for the chiral separation of structurally diverse compounds. Furthermore, it is important to note that our study demonstrated that surface binding is responsible for the formation of supramolecular complexes in certain cyclodextrin derivatives.

3.
Int J Mol Sci ; 24(3)2023 Jan 21.
Artigo em Inglês | MEDLINE | ID: mdl-36768492

RESUMO

The interaction between human serum albumin (HSA) and apremilast (APR), a novel antipsoriatic drug, was characterized by multimodal analytical techniques including high-performance liquid chromatography (HPLC), fluorescence spectroscopy and molecular docking for the first time. Using an HSA chiral stationary phase, the APR enantiomers were well separated, indicating enantioselective binding between the protein and the analytes. The influence of chromatographic parameters-type and concentration of the organic modifier, buffer type, pH, ionic strength of the mobile phase, flow rate and column temperature-on the chromatographic responses (retention factor and selectivity) was analyzed in detail. The results revealed that the eutomer S-APR bound to the protein to a greater extent than the antipode. The classical van 't Hoff method was applied for thermodynamic analysis, which indicated that the enantioseparation was enthalpy-controlled. The stability constants of the protein-enantiomer complexes, determined by fluorescence spectroscopy, were in accordance with the elution order observed in HPLC (KR-APR-HSA = 6.45 × 103 M-1, KS-APR-HSA = 1.04 × 104 M-1), showing that, indeed, the later-eluting S-APR displayed a stronger binding with HSA. Molecular docking was applied to study and analyze the interactions between HSA and the APR enantiomers at the atomic level. It was revealed that the most favored APR binding occurred at the border between domains I and II of HSA, and secondary interactions were responsible for the different binding strengths of the enantiomers.


Assuntos
Albumina Sérica Humana , Albumina Sérica , Humanos , Albumina Sérica Humana/metabolismo , Simulação de Acoplamento Molecular , Albumina Sérica/metabolismo , Estereoisomerismo , Cromatografia Líquida de Alta Pressão/métodos , Termodinâmica , Ligação Proteica , Sítios de Ligação , Espectrometria de Fluorescência