Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
1.
J Clin Med ; 13(8)2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38673430

RESUMO

Objectives: Conduction system pacing (CSP) and atrioventricular junction ablation (AVJA) improve the outcomes in patients with symptomatic, refractory atrial fibrillation (AF). In this setting, AVJA can be performed simultaneously with implantation or in a second procedure a few weeks after implantation. Comparison data on these two alternative strategies are lacking. Methods: A prospective, multicentre, observational study enrolled consecutive patients with symptomatic, refractory AF undergoing CSP and AVJA performed in a single procedure or in two separate procedures. Data on the long-term outcomes and healthcare resource utilization were prospectively collected. Results: A total of 147 patients were enrolled: for 105 patients, CSP implantation and AVJA were performed simultaneously (concomitant AVJA); in 42, AVJA was performed in a second procedure, with a mean of 28.8 ± 19.3 days from implantation (delayed AVJA). After a mean follow-up of 12 months, the rate of procedure-related complications was similar in both groups (3.8% vs. 2.4%; p = 0.666). Concomitant AVJA was associated with a lower number of procedure-related hospitalizations per patient (1.0 ± 0.1 vs. 2.0 ± 0.3; p < 0.001) and with a lower number of hospital treatment days per patient (4.7 ± 1.8 vs. 7.4 ± 1.9; p < 0.001). Conclusions: Concomitant AVJA resulted as being as safe as delayed AVJA and was associated with a lower utilization of healthcare resources.

2.
Heart Rhythm ; 21(6): 874-880, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38428448

RESUMO

BACKGROUND: Cardiac resynchronization therapy (CRT) with biventricular pacing (BVP) is a well-established therapy in patients with reduced left ventricular ejection fraction, heart failure, and left bundle branch block. Left bundle branch area pacing (LBBAP) has recently been shown to be a feasible and effective alternative to BVP. Comparative data on the risk of complications between LBBAP and BVP among patients undergoing CRT are lacking. OBJECTIVE: The aim of this study was to compare the long-term risk of procedure-related complications between LBBAP and BVP in a cohort of patients undergoing CRT. METHODS: This prospective, multicenter, observational study enrolled 668 consecutive patients (mean age 71.2 ± 10.0 years; 52.2% male; 59.4% with New York Heart Association class III-IV heart failure symptoms) with left ventricular ejection fraction 33.4% ± 4.3% who underwent BVP (n = 561) or LBBAP (n = 107) for a class I or II indication for CRT. Propensity score matching for baseline characteristics yielded 93 matched pairs. The rate and nature of intraprocedural and long-term post-procedural complications occurring during follow-up were prospectively collected and compared between the 2 groups. RESULTS: During a mean follow-up of 18 months, procedure-related complications were observed in 16 patients: 12 in BVP (12.9%) and 4 in LBBAP (4.3%) (P = .036). Compared with patients who underwent LBBAP, those who underwent BVP showed a lower complication-free survival (P = .032). In multivariate analysis, BVP resulted an independent predictive factor associated with a higher risk of complications (hazard ratio 3.234; P = .042). Complications related to the coronary sinus lead were most frequently observed in patients who underwent BVP (50.0% of all complications). CONCLUSION: LBBAP was associated with a lower long-term risk of device-related complications compared with BVP in patients with an indication for CRT.


Assuntos
Bloqueio de Ramo , Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Pontuação de Propensão , Sistema de Registros , Volume Sistólico , Humanos , Masculino , Feminino , Idoso , Terapia de Ressincronização Cardíaca/métodos , Terapia de Ressincronização Cardíaca/efeitos adversos , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/fisiopatologia , Estudos Prospectivos , Bloqueio de Ramo/terapia , Bloqueio de Ramo/fisiopatologia , Volume Sistólico/fisiologia , Resultado do Tratamento , Fascículo Atrioventricular/fisiopatologia , Seguimentos , Função Ventricular Esquerda/fisiologia
3.
Pacing Clin Electrophysiol ; 46(10): 1258-1268, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37665040

RESUMO

BACKGROUND: Conduction system pacing (CSP), including His-bundle pacing (HBP) and left bundle branch area pacing (LBBAP), have been proposed as alternatives to biventricular pacing (BVP) in patients scheduled for ablate and pace (A&P) strategy. The aim of this study was to compare the clinical outcomes, including the rate and nature of device-related complications, between BVP and CSP in a cohort of patients undergoing A&P. METHODS: Prospective, multicenter, observational study, enrolling consecutive patients undergoing A&P. The risk of device-related complications and of heart failure (HF) hospitalization was prospectively assessed. RESULTS: A total of 373 patients (75.3 ± 8.7 years, 53.9% male, 68.9% with NYHA class ≥III) were enrolled: 263 with BVP, 68 with HBP, and 42 with LBBAP. Baseline characteristics of the three groups were similar. Compared to BVP and HBP, LBBAP was associated with the shortest mean procedural and fluoroscopy times and with the lowest acute capture thresholds (all p < .05). At 12-month follow-up LBBAP maintained the lowest capture thresholds and showed the longest estimated residual battery longevity (all p < .05). At 12-months follow-up the three study groups showed a similar risk of device-related complications (5.7%, 4.4%, and 2.4% for BVP, HBP, and LBBAP, respectively; p = .650), and of HF hospitalization (2.7%, 1.5%, and 2.4% for BVP, HBP, and LBBAP, respectively; p = .850). CONCLUSIONS: In the setting of A&P, CSP is a feasible pacing modality, with a midterm safety profile comparable to BVP. LBBAP offers the advantage of reducing procedural times and obtaining lower and stable capture thresholds, with a positive impact on the device longevity.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Humanos , Masculino , Feminino , Estudos Prospectivos , Sistema de Condução Cardíaco , Doença do Sistema de Condução Cardíaco , Fontes de Energia Elétrica , Insuficiência Cardíaca/terapia , Fascículo Atrioventricular , Resultado do Tratamento , Eletrocardiografia , Estimulação Cardíaca Artificial
4.
Heart Rhythm ; 20(7): 984-991, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36906165

RESUMO

BACKGROUND: Conduction system pacing (CSP) using His bundle pacing (HBP) or left bundle branch area pacing (LBBAP) has emerged as an alternative to right ventricular pacing (RVP). Comparative data on the risk of complications between CSP and RVP are lacking. OBJECTIVE: This prospective, multicenter, observational study aimed to compare the long-term risk of device-related complications between CSP and RVP. METHODS: A total of 1029 consecutive patients undergoing pacemaker implantation with CSP (including HBP and LBBAP) or RVP were enrolled. Propensity score matching for baseline characteristics yielded 201 matched pairs. The rate and nature of device-related complications occurring during follow-up were prospectively collected and compared between the 2 groups. RESULTS: During a mean follow-up duration of 18 months, device-related complications were observed in 19 patients: 7 in RVP (3.5%) and 12 in CSP (6.0%) (P = .240). On dividing the matched cohort into 3 groups with similar baseline characteristics according to pacing modality (RVP, n = 201; HBP, n = 128; LBBAP, n = 73), patients with HBP showed a significantly higher rate of device-related complications than did patients with RVP (8.6% vs 3.5%; P = .047) and patients with LBBAP (8.6% vs 1.3%; P = .034). Patients with LBBAP showed a rate of device-related complications similar to that of patients with RVP (1.3% vs 3.5%; P = .358). Most of the complications observed in patients with HBP (63.6%) were lead related. CONCLUSION: Globally, CSP was associated with a risk of complications similar to that of RVP. Considering HBP and LBBAP separately, HBP showed a significantly higher risk of complications than did both RVP and LBBAP whereas LBBAP showed a risk of complications similar to that of RVP.


Assuntos
Fascículo Atrioventricular , Estimulação Cardíaca Artificial , Humanos , Estudos Prospectivos , Pontuação de Propensão , Estimulação Cardíaca Artificial/efeitos adversos , Estimulação Cardíaca Artificial/métodos , Eletrocardiografia/métodos , Doença do Sistema de Condução Cardíaco , Resultado do Tratamento
5.
J Cardiovasc Dev Dis ; 10(2)2023 Feb 02.
Artigo em Inglês | MEDLINE | ID: mdl-36826558

RESUMO

AIMS: To explore the impact of the use of intracardiac echocardiography (ICE) in the ablation of supraventricular arrhythmias requiring transseptal catheterization (TSC), whilst analyzing the reduction in periprocedural complications and complications specifically related to TSC. METHODS: A retrospective multicenter study collecting data from consecutive atrial fibrillation (AF) and supraventricular ablation procedures that required TSC was performed in five Italian centers. Based on physician discretion, TSC was performed with or without ICE. Periprocedural complications, separating all complications from complications directly related to TSC, were collected. Independent predictors of periprocedural complications and TSC-related complications were investigated. RESULTS: A total of 2181 TSCs were performed on 1862 patients at five Italian centers from 2006 to 2021, in 76% of cases by AF ablation and in 24% by ablation of other arrhythmias with a circuit in the left atrium. Overall, 1134 (52%) procedures were performed with ICE support and 1047 (48%) without ICE. A total of 67 (3.1%) complications were detected, 19 (1.7%) in the ICE group and 48 (4.6%) in the no ICE group, p < 0.001. A total of 42 (1.5%) complications directly related to TSC: 0.9% in the ICE group and 3.1% in the no ICE group (p < 0.001). The independent predictors of all complications were age (OR 1,02 95% C.I 1.00-1.05; p = 0.036), TSC with the use of ICE (OR 0.27 95% C.I 0.15-0.46; p < 0.001) and AF ablation (OR 2,25 95%C.I 1.05-4.83; p = 0.037). The independent predictors for TSC complications were age (OR 1.03 95% C.I 1.01-1.06; p = 0.013) and TSC with the use of ICE (OR 0.24 95% C.I 0.11-0.49; p < 0.001). CONCLUSIONS: ICE reduced periprocedural and TSC-related complications during electrophysiological procedures for ablation of left atrial arrhythmias.

6.
Minerva Cardiol Angiol ; 71(4): 438-443, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-33146479

RESUMO

BACKGROUND: Radiofrequency ablation of the cavotricuspid isthmus is currently the first-choice treatment of typical atrial flutter and usually it is performed electively. The purpose of this study was to see whether performing on-line ablation has similar clinical results compared to the conventional strategy. METHODS: Consecutive patients (465) who underwent ablation of the cavotricuspid isthmus for typical atrial flutter (AFL) at our electrophysiology laboratory in the 2008-2017 decade were studied. We evaluated the acute and long-term clinical outcomes of those who were treated electively (337) compared to those who had online ablation (128), that is within 24 hours of presenting to the Department of Cardiology. In patients treated on an emergency basis, a transesophageal echocardiogram was performed to rule atrial thrombi when needed. RESULTS: No significant intraprocedural difference was observed between the 2 patient groups, with comparable acute electrophysiological success (99% vs. 98%) and serious complications. Even at the subsequent 4-year follow-up, there were no significant differences in the recurrence of typical AFL, onset of atrial fibrillation and other clinical events. CONCLUSIONS: Online ablation of typical atrial flutter performed at the time of the clinical presentation of the arrhythmia, was shown to be comparable in terms of procedural safety and clinical efficacy in the short and long term compared to an elective ablation strategy.


Assuntos
Fibrilação Atrial , Flutter Atrial , Ablação por Cateter , Ablação por Radiofrequência , Humanos , Flutter Atrial/cirurgia , Flutter Atrial/etiologia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Resultado do Tratamento , Fibrilação Atrial/cirurgia
7.
J Cardiovasc Electrophysiol ; 33(11): 2288-2296, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35930617

RESUMO

INTRODUCTION: In patients with symptomatic permanent atrial fibrillation (PEAF) and narrow QRS, atrio-ventricular junction ablation (AVJA) plus cardiac resynchronization therapy (CRT) is superior to medical therapy in reducing heart failure (HF) hospitalization and all-cause mortality. To compare the mortality of a population of patients with HF, reduced EF (rEF), and PEAF treated with AVJA plus CRT with that of a contemporary cohort of patients in sinus rhythm (SR) with similar baseline characteristics. METHODS AND RESULTS: In this prospective, multicentre, observational study, all-cause mortality in a group of consecutive patients undergoing AVJA and implantable cardioverter-defibrillator (ICD) combined with CRT implantation for HFrEF, narrow QRS, and PEAF with uncontrolled ventricular rate was compared with that of a contemporary cohort of patients in SR undergoing ICD implantation (not combined with CRT) for HFrEF and narrow QRS. Individual 1:1 propensity matching of baseline characteristics was performed. A total of 824 patients were enrolled. Propensity matching yielded 107 matched pairs. After a median follow-up of 52 months, all-cause mortality was similar in patients treated with AVJA plus CRT and in the control group (p = .434). In AVJA plus CRT patients, mortality was significantly lower than in control group patients with a history of paroxysmal/persistent AF (n = 45, p = .020), and similar to that of patients without a history of AF (n = 62, p = .459). CONCLUSIONS: After adjustment for patient characteristics, the long-term prognosis of patients with HFrEF, narrow QRS, and PEAF who underwent AVJA plus CRT was similar to that of a population of patients in SR with similar characteristics.


Assuntos
Fibrilação Atrial , Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Disfunção Ventricular Esquerda , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/etiologia , Estudos Prospectivos , Volume Sistólico , Resultado do Tratamento , Disfunção Ventricular Esquerda/terapia
8.
Pacing Clin Electrophysiol ; 44(9): 1532-1539, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34374444

RESUMO

BACKGROUND: His bundle pacing (HBP), alone or optimized in association with coronary sinus pacing (HBP+LV) has recently been proposed as an alternative to conventional cardiac resynchronization therapy (CRT). However, there is lack of controlled studies that assessed clinical outcome. METHODS: We did a single-center, propensity-score matched, case-control study of comparison of HBP and HBP+LV versus conventional CRT in patients with heart failure (HF) and standard indications for CRT. The study group patients were consecutively enrolled in the year 2019. The control group patients were selected, by propensity score matching, among those CRT implantations performed in the years 2015-2018. RESULTS: There were 27 patients in each group. In the active group, 12 (44%) patients received HBP alone and 12 (44%) patients HBP+LV pacing. HBP failed in three (11%) patients. In the control group, conventional CRT was achieved in 26 (96%) patients and failed in one. Paced QRS width was shorter in the active than in the control group (128 ± 18 vs. 148 ± 27 ms, p = .004). During a mean of 9.6 months of follow-up, a composite clinical outcome of death, hospitalization for HF or worsening HF occurred in three (11%) in the active group and in four (15%) in the control group, p = .58. No difference was also observed with softer endpoints: NYHA class (1.9 ± 0.7 vs. 2.1 ± 0.7), subjective improvement (74% vs. 74%) and LV ejection fraction (40.7% vs. 40.7%). CONCLUSION: Compared with conventional CRT, a shorter QRS width can be obtained with HBP alone or in association with coronary sinus pacing but we were unable to show a better clinical outcome. There is urgent need for large, randomized trials.


Assuntos
Fascículo Atrioventricular/fisiopatologia , Terapia de Ressincronização Cardíaca/métodos , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Idoso , Estudos de Casos e Controles , Feminino , Humanos , Masculino , Pontuação de Propensão
9.
J Electrocardiol ; 68: 85-89, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34403948

RESUMO

PURPOSE: The implantation site of the His bundle (HB) lead may influence pacing parameters. Our aim was to characterize the anatomical location of the HB lead tip and its relationship with acute electrical parameters. METHODS: Consecutive patients who underwent HB lead implantation, guided by standard fluoroscopy and electrophysiology, were prospectively enrolled. The relationship between HB lead tip and tricuspid valve plane (TVP) was assessed with post-procedure transthoracic echocardiography. RESULTS: Twenty-five patients were studied. In 11 patients (44%), the HB lead tip did not cross the TVP (A group): in 7 cases it was screwed in the right atrium at a mean distance of -6.1 mm from the TVP and, in 4 cases, at the level of the tricuspid annulus. In the remaining 14 patients (56%), the lead tip crossed the TVP (V group): it was screwed in the right ventricle at a mean distance of 9.3 mm from the TVP. A and V groups had comparable HB capture thresholds (1.6 ± 1 V vs 1.7 ± 0.7 V, 1 ms pulse-width; p = 0.66); selective HB capture was significantly more represented in the A group (91% vs 21%; p = 0.001). Significantly higher R-wave amplitudes were seen in the V group (6.7 ± 3 vs 2.5 ± 1.7 mV; p = 0.0004), and they positively correlated with the distance from the TVP (p = 0.0038). Atrial oversensing was never observed. CONCLUSION: In a consecutive cohort of HB pacing recipients, the rate of patients who had an effective HB capture in the atrium was substantial and was characterized by different electrophysiological properties than in the ventricle.


Assuntos
Fascículo Atrioventricular , Estimulação Cardíaca Artificial , Ecocardiografia , Eletrocardiografia , Frequência Cardíaca , Humanos
10.
J Electrocardiol ; 64: 95-98, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33412431

RESUMO

We present the case of a professional soccer player affected by right bundle branch block and symptomatic 2:1 atrio-ventricular block during effort, due to progressive cardiac conduction disease (Lev-Lenegre disease), who received successful left bundle branch area pacing after a failed attempt at His bundle pacing. The electrocardiographic outcome of paced QRS was consistent with a rapid electrical activation of the left ventricle through the Purkinje system. The pursue of physiological pacing was preferred over conventional, given the young age of our patient and the expectedly high burden of stimulation, to reduce the long-term risk of pacing-induced cardiomyopathy.


Assuntos
Fascículo Atrioventricular , Estimulação Cardíaca Artificial , Atletas , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/terapia , Eletrocardiografia , Humanos
11.
Europace ; 22(11): 1737-1741, 2020 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-33078193

RESUMO

AIMS: Indications, methodology, and diagnostic criteria for carotid sinus massage (CSM) and tilt testing (TT) have been standardized by the 2018 Guidelines on Syncope of the European Society of Cardiology. Aim of this study was to assess their effectiveness in a large cohort which reflects the performance under 'real-world' conditions. METHODS AND RESULTS: We analysed all patients who had undergone CSM and TT in the years 2003-2019 for suspected reflex syncope. Carotid sinus massage was performed according to the 'Method of Symptoms'. Tilt testing was performed according to the 'Italian protocol' which consists of a passive phase followed by a sublingual nitroglycerine phase. For both tests, positive test was defined as reproduction of spontaneous symptoms in the presence of bradycardia and/or hypotension. Among 3293 patients (mean age 73 ± 12 years, 48% males), 2019 (61%) had at least one test positive. A bradycardic phenotype was found in 420 patients (13%); of these, 60% were identified by CSM, 37% by TT, and 3% had both test positive. A hypotensive phenotype was found in 1733 patients (53%); of these, 98% were identified by TT and 2% had both TT and CSM positive. CONCLUSION: The overall diagnostic yield of the tests in patients >40-year-old with suspected reflex syncope was 61%. Both CSM and TT are useful for identifying those patients with a bradycardic phenotype, whereas CSM has a limited value for identifying the hypotensive phenotype. Since the overlap of responses between tests is minimal, both CSM and TT should be performed in every patient over 40 years receiving investigation for unexplained but possible reflex syncope.


Assuntos
Seio Carotídeo , Teste da Mesa Inclinada , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Feminino , Humanos , Itália , Masculino , Massagem , Pessoa de Meia-Idade , Reflexo , Síncope/diagnóstico
12.
Pacing Clin Electrophysiol ; 43(10): 1190-1193, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32364652

RESUMO

AIMS: The reproducibility of carotid sinus massage (CSM) is debated. The aim of this study was to assess the reproducibility according to the methodology and diagnostic criteria defined by the guidelines on syncope of the European Society of Cardiology. METHOD: Among 2800 patients with syncope who underwent CSM in the years 2005-2019, 109 patients (62 males; mean age 76 ± 10 years) had performed a second CSM after a median of 28 months. Carotid sinus hypersensitivity (CSH) was diagnosed when CSM elicited a pause of >3 s and/or a fall in systolic blood pressure >50 mm Hg without reproduction of spontaneous symptoms. Carotid sinus syndrome (CSS) was established when spontaneous symptoms were reproduced in the presence of bradycardia and/or hypotension. RESULTS: The reproducibility of CSM was 78% for 18 CSS patients, 41% for 29 CSH patients, and 77% for 62 negative patients. The corresponding interrater agreement was good for CSS (kappa = 0.66), moderate for negative CSM (kappa = 0.42), and poor for CSH (kappa = 0.30). Combining CSH and negative tests, their reproducibility rose to 90% with kappa = 0.66. CONCLUSION: CSS but not CSH has a good reproducibility. About half of patients with CSH had a negative response at the second test, thus suggesting a great overlap between them.


Assuntos
Seio Carotídeo/fisiopatologia , Síncope/diagnóstico , Síncope/fisiopatologia , Idoso , Feminino , Humanos , Itália , Masculino , Reprodutibilidade dos Testes
13.
J Cardiovasc Electrophysiol ; 31(3): 647-657, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31957086

RESUMO

INTRODUCTION: Dyssynchrony persists in many patients despite cardiac resynchronization therapy (CRT). Aim of this proof-of-concept study was to achieve better CRT, with a QRS approximating the normal width and axis, by using His bundle pacing (HBP) and nonconventional pacing configurations. METHODS AND RESULTS: In 20 patients with CRT indications, we performed an acute intrapatient comparison between conventional biventricular (CONV) and three nonconventional pacing modalities: HBP alone, His bundle, and coronary sinus pacing (HBP + CS), and HBP + CS plus right ventricular pacing (TRIPLE). Electrical dyssynchrony was assessed by means of QRS width and axis; "quasi-normal" axis meant an R/S ratio ≥ 1 in leads I and V6 and ≤1 in V1. Mechanical dyssynchrony was assessed by speckle tracking echocardiography. QRS width was 153 ± 18 ms on CONV, shortened to 137 ± 16 ms on HBP + CS (P = .001) and to 130 ± 14 ms on TRIPLE (P = .001), while it remained unchanged on HBP (159 ± 32 ms; P = .17). The rate of patients with "quasi-normal" axis was 5% on CONV, and increased to 90% on HBP (P = .0001), to 63% on HBP + CS (P = .001), and to 44% on TRIPLE (P = .02). On radial strain analysis, the time-to-peak difference between anteroseptal and posterolateral segments was 143 ± 116 ms on CONV, shortened to 121 ± 127 ms on HBP (P = .79), to 67 ± 70 ms on HBP + CS (P = .02), and to 76 ± 55 ms on TRIPLE (P = .05). On discharge, HBP was chosen in 15% of patients, HBP + CS in 55%, and TRIPLE in 30%; CONV was never chosen. CONCLUSION: Nonconventional modalities of CRT provide acute additional electrical and mechanical resynchronization. An interpatient variability exists.


Assuntos
Arritmias Cardíacas/terapia , Fascículo Atrioventricular/fisiopatologia , Terapia de Ressincronização Cardíaca/métodos , Insuficiência Cardíaca/terapia , Potenciais de Ação , Idoso , Idoso de 80 Anos ou mais , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatologia , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Estudo de Prova de Conceito , Estudos Prospectivos , Fatores de Tempo , Resultado do Tratamento
14.
J Am Heart Assoc ; 7(9)2018 04 19.
Artigo em Inglês | MEDLINE | ID: mdl-29674334

RESUMO

BACKGROUND: The mechanism of inappropriate sinus tachycardia (IST) remains incompletely understood. METHODS AND RESULTS: We prospectively compared 3 patient groups: 11 patients with IST (IST Group), 9 control patients administered isoproterenol (Isuprel Group), and 15 patients with cristae terminalis atrial tachycardia (AT Group). P-wave amplitude in lead II and PR interval were measured at a lower and higher heart rate (HR1 and HR2, respectively). P-wave amplitude increased significantly with the increase in HR in the IST Group (0.16±0.07 mV at HR1=97±12 beats per minute versus 0.21±0.08 mV at HR2=135±21 beats per minute, P=0.001). The average increase in P-wave amplitude in the IST Group was similar to the Isuprel Group (P=0.26). PR interval significantly shortened with the increases in HR in the IST Group (146±15 ms at HR1 versus 128±16 ms at HR2, P<0.001). A similar decrease in the PR interval was noted in the Isuprel Group (P=0.6). In contrast, patients in the atrial tachycardia Group experienced PR lengthening during atrial tachycardia when compared with baseline normal sinus rhythm (153±25 ms at HR1=78±17 beats per minute versus 179±29 ms at HR2=140±28 beats per minute, P<0.01). CONCLUSIONS: We have shown that HR increases in patients with IST were associated with an increase in P-wave amplitude in lead II and PR shortening similar to what is seen in healthy controls following isoproterenol infusion. The increase in P-wave amplitude and absence of PR lengthening in IST support an extrinsic mechanism consistent with a state of sympatho-excitation with cephalic shift in sinus node activation and enhanced atrioventricular nodal conduction.


Assuntos
Potenciais de Ação , Nó Atrioventricular/fisiopatologia , Frequência Cardíaca , Nó Sinoatrial/fisiopatologia , Taquicardia Sinusal/fisiopatologia , Adulto , Idoso , Estudos de Casos e Controles , Eletrocardiografia , Técnicas Eletrofisiológicas Cardíacas , Feminino , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Taquicardia Sinusal/diagnóstico , Fatores de Tempo , Wisconsin , Adulto Jovem
16.
Pacing Clin Electrophysiol ; 39(10): 1126-1131, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27565449

RESUMO

BACKGROUND: According to the ACC/AHA/HRS guidelines, cardiac pacing is reasonable in patients with bifascicular block (BF-B) and syncope when other causes have been excluded. The purpose of this study was to assess the long-term outcome of patients with BF-B and unexplained syncope following cardiac pacing. METHODS AND RESULTS: Between 2009 and 2015, we identified 43 consecutive patients (mean age of 78 ± 12 years, 64% males) who presented with syncope and BF-B and had received a pacemaker (PM). During a mean follow-up period of 31 ± 21 months, syncope recurred in seven patients (16%): 7% (95% standard error [SE] ± 3%) at 1 year and 18% (95% SE ± 7%) at 5 years. At univariable analysis, the only predictor of syncope recurrence was empiric pacing (P = 0.03). There were no syncope recurrences in the 12 patients who received a PM following a positive electrophysiological study (EPS) and the five patients with documentation of paroxysmal atrioventricular block (AVB) during cardiac monitoring (insertable loop recorder [ILR]), (EPS/ILR Group, n = 17) compared to seven of 26 (27%) patients who received empiric pacing (Empiric Group, n = 26; P = 0.02). Progression to high-degree AVB was documented during follow-up in 16 (37%) patients: nine of 17 (53%) patients in the EPS/ILR Group and seven of 26 (27%) patients in the Empiric Group (P = 0.11). There were no injuries reported during ILR monitoring. CONCLUSIONS: We have shown that syncope recurs not infrequently in patients with BF-B who received pacing for syncope. Nearly one in four patients who had empiric pacing suffered syncope recurrence compared to no recurrences in patients who received a PM following a positive EPS or documentation of transient AVB.


Assuntos
Estimulação Cardíaca Artificial , Bloqueio Cardíaco/terapia , Síncope/terapia , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Bloqueio Cardíaco/complicações , Humanos , Masculino , Recidiva , Resultado do Tratamento
17.
J Cardiovasc Electrophysiol ; 27(11): 1319-1324, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27489134

RESUMO

INTRODUCTION: The aim of this study was to assess long-term results after single and multiple procedures of catheter ablation of ventricular tachycardia (VT). While it is generally accepted that multiple procedures are sometimes necessary in order to achieve long-term clinical success, the literature on this issue displays wide variability. METHODS: We assessed the outcome of 160 consecutive patients who underwent 214 ablation procedures in the period 2008 to May 2015: 93 had overt structural heart disease (SHD) (previous myocardial infarction in 74 cases) and 67 had no SHD. RESULTS: After the first procedure, the 1-year actuarial recurrence rates were 25% in patients with SHD and 5% in those without. However, recurrences increased progressively after the first year, reaching 46% and 35%, respectively, at 5 years. Overall, VT recurred in 35/93 (38%) patients with SHD and 22/67 (33%) patients without. Redo (1 to 4) procedures were performed in 28 (20%) patients with SHD and 18 (27%) patients without. After the last procedure, the 1-year actuarial recurrence rates were 5% in patients with SHD and 7% in those without, and the corresponding rates at 5 years were 23% and 7%. During follow-up, 21 patients died (all in the SHD group): no death was related to VT recurrence. CONCLUSIONS: During long-term follow-up, VT frequently recurs after the first procedure, both in patients with SHD and in those without; multiple procedures are needed in order to increase the success rate.

18.
Europace ; 18(11): 1735-1739, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26851815

RESUMO

AIMS: Although syncope is the main reason for cardiac pacing in ∼40% of patients affected by atrioventricular block (AVB), very few data are available on the benefit of cardiac pacing in preventing syncopal recurrences. METHODS AND RESULTS: We retrospectively evaluated 229 consecutive patients (124 males, age 80 ± 10 years) who had received a permanent pacemaker from January 2009 to December 2013 for AVB and syncope (94 patients, 41%) or AVB without syncope (135 patients, 59%). In patients with AVB and syncope, a third-degree or Mobitz II second-degree AVB had been documented in 73 and was only suspected in another 21, all of whom had bundle branch block. Follow-up was available in 223 patients. At 5 years, the actuarial syncope recurrence rate was 1% (95% CI, 0-3) in patients with documented AVB plus syncope and 3% (95% CI, 1-5) in those without syncope, whereas it was 14% (95% CI, 0-28) in patients with undocumented AVB plus syncope (P = 0.001). The actuarial combined recurrence rate of syncope and/or pre-syncope was 2% (95% CI, 0-4) in patients without syncope, 8% (95% CI, 0-17) in patients with documented AVB plus syncope, and 19% (95% CI, 1-37) in patients with undocumented AVB plus syncope, P = 0.002. All syncopes occurred in patients without overt structural heart disease (SHD), the corresponding actuarial estimate being 4% (95% CI, 0-6) at 1 year and 6% (95% CI, 4-8) at 5 years (P = 0.002 vs. patients with SHD). CONCLUSIONS: Cardiac pacing is highly effective in preventing syncopal recurrences when AVB is documented. Syncope may recur in a non-negligible minority of paced patients when AVB is suspected but not documented and in patients without SHD.


Assuntos
Bloqueio Atrioventricular/terapia , Bloqueio de Ramo/terapia , Estimulação Cardíaca Artificial , Marca-Passo Artificial , Síncope/epidemiologia , Síncope/prevenção & controle , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Itália , Masculino , Recidiva , Estudos Retrospectivos
19.
Europace ; 17(3): 403-8, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25336663

RESUMO

AIMS: Left atrial ablation fails to prevent symptomatic recurrences of atrial fibrillation (AF) in 20-30% of patients up to 3 years of follow-up despite multiple procedures. Data are lacking on the long-term clinical outcome of those patients for whom the decision was taken to renounce performing further ablation procedures. METHODS AND RESULTS: In this multicentre study, 218 (34%) of 631 consecutive patients, who had undergone AF catheter ablation in the years 2001-11 for drug-refractory symptomatic AF, had symptomatic AF recurrences after 1.5 ± 0.6 procedures. Their long-term clinical outcome was assessed in March 2012 (minimum follow-up 1 year). At a mean of 5.1 ± 2.6 years since their last ablation, 82 (38%) patients improved, 103 (47%) remained unchanged and 33 (15%) worsened, but only 17 (8%) had such a severe impairment of their quality of life as to require atrioventricular junction ablation and pacing (#13) or cardiac surgery (#4); 22 (10%) patients had had adverse clinical events (death in five, heart failure in five, stroke and transient ischaemic cerebral attack in four, severe haemorrhage in four, pacemaker or implantable cardioverter-defibrillator implantation in seven) and 98 (45%) patients had developed permanent AF. Compared with patients without permanent AF, fewer patients with permanent AF improved (3% vs. 66%, P = 0.001) and more got worse (28% vs. 5%, P = 0.001). At multivariable logistic regression, single ablation procedure, left atrial diameter, persistent AF and time from the last ablation were independent predictors of permanent AF. CONCLUSION: More than 5 years after a failed AF ablation, a small minority of patients had such an impaired quality of life as to require non-pharmacological interventions. Almost half developed permanent AF, which significantly impaired quality of life. Permanent AF was more common in patients who had left atrial enlargement, history of persistent AF, longer follow-up, and had performed a single ablation procedure, thus hypothesizing that reablation could reduce the chronicization of arrhythmia. A low risk of stroke was observed in the long-term follow-up.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Idoso , Antiarrítmicos/uso terapêutico , Anticoagulantes/efeitos adversos , Fibrilação Atrial/complicações , Fibrilação Atrial/tratamento farmacológico , Estudos de Coortes , Desfibriladores Implantáveis , Progressão da Doença , Feminino , Insuficiência Cardíaca/etiologia , Hemorragia/induzido quimicamente , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Marca-Passo Artificial , Qualidade de Vida , Recidiva , Reoperação , Estudos Retrospectivos , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Falha de Tratamento
20.
Circ Arrhythm Electrophysiol ; 7(3): 505-10, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24762808

RESUMO

BACKGROUND: Assessment of the vasodepressor reflex in carotid sinus syndrome is influenced by the method of execution of the carotid sinus massage and the coexistence of the cardioinhibitory reflex. METHODS AND RESULTS: Carotid sinus massage reproduced spontaneous symptoms in 164 patients in the presence of hypotension or bradycardia (method of symptoms). When an asystolic pause was induced, the vasodepressor reflex was reassessed after suppression of the asystolic reflex by means of 0.02 mg/kg IV atropine. An isolated vasodepressor form was found in 32 (20%) patients, who had lowest systolic blood pressure (SBP) of 65±15 mm Hg. Of these, only 21 (66%) patients had an SBP fall ≥50 mm Hg, which is the universally accepted cut-off value for the diagnosis of the vasodepressor form. Conversely, a lowest SBP value of ≤85 mm Hg (corresponding to the fifth percentile) detected 97% of vasodepressor patients, but was also present in 84% of the 132 patients with an asystolic reflex. These latter patients had both asystole ≥3 s (mean 7.6±2.2 s) and SBP fall to 63±22 mm Hg: in 46 (28%) patients, symptoms persisted after atropine (mixed form), in the remaining 86 (52%) patients, symptoms did not (cardioinhibitory form) persist. CONCLUSIONS: The current definition of ≥50 mm Hg SBP fall failed to identify one third of patients with isolated vasodepressor form. A cut-off value of symptomatic SBP of ≤85 mm Hg seems more appropriate, but it is unable to identify cardioinhibitory forms. In asystolic forms, atropine testing is able to distinguish a cardioinhibitory form from a mixed form.


Assuntos
Barorreflexo/efeitos dos fármacos , Pressão Sanguínea , Síncope Vasovagal/diagnóstico , Síncope/diagnóstico , Idoso , Idoso de 80 Anos ou mais , Atropina , Barorreflexo/fisiologia , Estudos de Coortes , Feminino , Humanos , Masculino , Massagem , Postura , Estudos Retrospectivos , Sensibilidade e Especificidade , Síndrome
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA