Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
ASAIO J ; 69(6): 569-575, 2023 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-37000917

RESUMO

Nonsurgical bleeding occurs in a significant proportion of patients implanted with continuous-flow ventricular assist devices (CF-VADs) and is associated with nonphysiologic flow with diminished pulsatility. An in vitro vascular pulse perfusion model seeded with adult human aortic endothelial cells (HAECs) was used to identify biomarkers sensitive to changes in pulsatility. Diminished pulsatility resulted in an ~45% decrease in von Willebrand factor (vWF) levels from 9.80 to 5.32 ng/ml (n = 5, p < 0.05) and a threefold increase in angiopoietin-2 (ANGPT-2) levels from 775.29 to 2471.93 pg/ml (n = 5, p < 0.05) in cultured HAECs. These changes are in agreement with evaluation of patient blood samples obtained pre-CF-VAD implant and 30-day postimplant: a decrease in plasma vWF level by 50% from ~45.59 to ~22.49 µg/ml (n = 15, p < 0.01) and a 64% increase in plasma ANGPT-2 level from 7,073 to 11,615 pg/ml (n = 8, p < 0.05). This study identified vWF and ANGPT-2 as highly sensitive to changes in pulsatility, in addition to interleukin-6 (IL-6), IL-8, and tumor necrosis-α (TNF-α). These biomarkers may help determine the optimal level of pulsatility and help identify patients at high risk of nonsurgical bleeding.


Assuntos
Coração Auxiliar , Doenças de von Willebrand , Adulto , Humanos , Fator de von Willebrand , Células Endoteliais , Coração Auxiliar/efeitos adversos , Angiopoietina-2 , Hemorragia/etiologia , Biomarcadores , Doenças de von Willebrand/etiologia
2.
Cells Tissues Organs ; 212(4): 352-362, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-35640546

RESUMO

The heart is a dynamic organ, and the cardiac tissue experiences changes in pressure and stretch during the cardiac cycle. Existing cell culture and animal models are limited in their capacity to decouple and tune specific hemodynamic stresses implicated in the development of physiological and pathophysiological cardiac tissue remodeling. This study focused on creating a system to subject engineered cardiac tissue to either pressure or stretch stimuli in isolation and the subsequent evaluation of acute tissue remodeling. We developed a cardiac tissue chip containing three-dimensional (3-D) cell-laden hydrogel constructs and cultured them within systems where we could expose them to either pressure changes or volume changes as seen in the left ventricle. Acute cellular remodeling with each condition was qualitatively and quantitatively assessed using histology, immunohistochemistry, gene expression studies, and soluble factor analysis. Using our unique model system, we isolated the effects of pressure and stretch on engineered cardiac tissue. Our results confirm that both pressure and stretch mediate acute stress responses in the engineered cardiac tissue. However, both experimental conditions elicited a similar acute phase injury response within this timeframe. This study demonstrates our ability to subject engineered cardiac tissue to either pressure or stretch stimuli in isolation, both of which elicited acute tissue remodeling responses.


Assuntos
Coração , Engenharia Tecidual , Animais , Engenharia Tecidual/métodos , Técnicas de Cultura de Células
3.
Cells Tissues Organs ; 211(3): 324-334, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-33631743

RESUMO

Cardiopulmonary bypass (CPB) results in short-term (3-5 h) exposure to flow with diminished pulsatility often referred to as "continuous flow". It is unclear if short-term exposure to continuous flow influences endothelial function, particularly, changes in levels of pro-inflammatory and pro-angiogenic cytokines. In this study, we used the endothelial cell culture model (ECCM) to evaluate if short-term (≤5 h) reduction in pulsatility alters levels of pro-inflammatory/pro-angiogenic cytokine levels. Human aortic endothelial cells (HAECs) cultured within the ECCM provide a simple model to evaluate endothelial cell function in the absence of confounding factors. HAECs were maintained under normal pulsatile flow for 24 h and then subjected to continuous flow (diminished pulsatile pressure and flow) as observed during CPB for 5 h. The ECCM replicated pulsatility and flow morphologies associated with normal hemodynamic status and CPB as seen with clinically used roller pumps. Levels of angiopoietin-2 (ANG-2), vascular endothelial growth factor-A (VEGF-A), and hepatocyte growth factor were lower in the continuous flow group in comparison to the pulsatile flow group whereas the levels of endothelin-1 (ET-1), granulocyte colony stimulating factor, interleukin-8 (IL-8) and placental growth factor were higher in the continuous flow group in comparison to the pulsatile flow group. Immunolabelling of HAECs subjected to continuous flow showed a decrease in expression of ANG-2 and VEGF-A surface receptors, tyrosine protein kinase-2 and Fms-related receptor tyrosine kinase-1, respectively. Given that the 5 h exposure to continuous flow is insufficient for transcriptional regulation, it is likely that pro-inflammatory/pro-angiogenic signaling observed was due to signaling molecules stored in Weible-Palade bodies (ET-1, IL-8, ANG-2) and via HAEC binding/uptake of soluble factors in media. These results suggest that even short-term exposure to continuous flow can potentially activate pro-inflammatory/pro-angiogenic signaling in cultured HAECs and pulsatile flow may be a successful strategy in reducing the undesirable sequalae following continuous flow CPB.


Assuntos
Ponte Cardiopulmonar , Células Endoteliais , Ponte Cardiopulmonar/efeitos adversos , Feminino , Humanos , Interleucina-8 , Fator de Crescimento Placentário , Fator A de Crescimento do Endotélio Vascular
4.
Artif Organs ; 46(5): 887-898, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-34866200

RESUMO

BACKGROUND: Patients with continuous flow ventricular assist devices (CF-VADs) are at high risk for non-surgical bleeding, speculated to associate with the loss of pulsatility following CF-VAD placement. It has been hypothesized that continuous shear stress causes elongation and increased enzymatic degradation of von Willebrand Factor (vWF), a key player in thrombus formation at sites of vascular damage. However, the role of loss of pulsatility on the unravelling behavior of vWF has not been widely explored. METHODS: vWF molecules were immobilized on the surface of microfluidic devices and subjected to various pulsatile flow profiles, including continuous flow and pulsatile flow of different magnitudes, dQ/dt (i.e., first derivative of flow rate) of pulsatility and pulse frequencies to mimic in vivo shear flow environments with and without CF-VAD support. VWF elongation was observed using total internal reflection fluorescence (TIRF) microscopy. Besides, the vWF level is measured from the patients' blood sample before and after CF-VAD implantation from a clinical perspective. To our knowledge, this work is the first in providing direct, visual observation of single vWF molecule extension under controlled-pulsatile shear flow. RESULTS: Unravelling of vWF (total sample size n ~ 200 molecules) is significantly reduced under pulsatile flow (p < 0.01) compared to continuous flow. An increase in the magnitude of pulsatility further reduces unravelling lengths, while lower frequency of pulsatility (20 vs. 60 pulses per min) does not have a major effect on the maximum or minimum unravelling lengths. Evaluation of CF-VAD patient blood samples (n = 13) demonstrates that vWF levels decreased by ~40% following CF-VAD placement (p < 0.01), which correlates to single-molecule observations from a clinical point of view. CONCLUSIONS: Pulsatile flow reduces unfolding of vWF compared to continuous flow and a lower pulse frequency of 20 pulses/minute yielded comparable vWF unfolding to 60 pulses/minute. These findings could shed light on non-surgical bleeding associated with the loss of pulsatility following CF-VAD placement.


Assuntos
Coração Auxiliar , Trombose , Coração Auxiliar/efeitos adversos , Hemorragia/etiologia , Humanos , Fluxo Pulsátil , Trombose/etiologia , Fator de von Willebrand/metabolismo
5.
Micromachines (Basel) ; 12(2)2021 Jan 28.
Artigo em Inglês | MEDLINE | ID: mdl-33525451

RESUMO

Tissue chips (TCs) and microphysiological systems (MPSs) that incorporate human cells are novel platforms to model disease and screen drugs and provide an alternative to traditional animal studies. This review highlights the basic definitions of TCs and MPSs, examines four major organs/tissues, identifies critical parameters for organization and function (tissue organization, blood flow, and physical stresses), reviews current microfluidic approaches to recreate tissues, and discusses current shortcomings and future directions for the development and application of these technologies. The organs emphasized are those involved in the metabolism or excretion of drugs (hepatic and renal systems) and organs sensitive to drug toxicity (cardiovascular system). This article examines the microfluidic/microfabrication approaches for each organ individually and identifies specific examples of TCs. This review will provide an excellent starting point for understanding, designing, and constructing novel TCs for possible integration within MPS.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA