1.
Artif Organs ; 45(3): 278-288, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32969519

RESUMO

The damage caused to the fabric of endovascular stent-grafts most often occurs at the contact zones between the fabrics where they are attached to the apices of Z-shaped stents as a result of normal physiologic pulsatile movement within angulated vessels in vivo. Although design improvements were made over the years, the risks were not fully eliminated even with the newer M-shaped stent reconfiguration. In this study, we proposed to create and manufacture a novel fabric for stent-grafts with specifically designed reinforced zones to enhance resistance to fabric abrasion. These reinforced zones are set at the vicinity of the apices of the Z-shaped stents and between two adjacent Z-shaped stents where folding and pleating are commonly observed to occur in angulated vessels. Three innovative weaving structures with two different types of yarns and two controls were designed and prepared. Two commonly used commercial devices supported, respectively, with ringed stents, and Z-shaped stents were selected as the references for comparison. Textile structures including thickness, water permeability, mechanical properties, (more specifically tensile and bursting stress, as well as fatigue simulation) were tested on all fabrics. Compared to commercially available plain weaves, the fabrics with locally reinforced zones showed improved mechanical characteristics and fatigue resistant properties. A fabric designed with specifically reinforced zones has now clearly been shown to effectively reduce the abrasion caused by the apices of Z-shaped stents. However, further optimization may still be possible.


Assuntos
Implante de Prótese Vascular/efeitos adversos , Endoleak/prevenção & controle , Procedimentos Endovasculares/efeitos adversos , Desenho de Prótese , Têxteis , Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Endoleak/etiologia , Procedimentos Endovasculares/instrumentação , Teste de Materiais , Stents/efeitos adversos
2.
Ann Biomed Eng ; 45(6): 1462-1474, 2017 06.
Artigo em Inglês | MEDLINE | ID: mdl-28361184

RESUMO

The rupture of an atherosclerotic plaque in the coronary circulation remains the main cause of heart attack. As a fiber-oriented structure, the fiber structure, in particular in the fibrous cap (FC), may affect both loading and material strength in the plaque. However, the role of fiber orientation and dispersion in plaque rupture is unclear. Local orientation and dispersion of fibers were calculated for the shoulder regions, mid FC, and regions with intimal thickening (IT) from histological images of 16 human coronary atherosclerotic lesions. Finite element analysis was performed to assess the effect of these properties on mechanical conditions. Fibers in shoulder regions had markedly reduced alignment (Median [interquartile range] 12.9° [6.6, 18.0], p < 0.05) compared with those in mid FC (6.1° [5.5, 9.0]) and IT regions (6.7° [5.1, 8.6]). Fiber dispersion was highest in shoulders (0.150 [0.121, 0.192]), intermediate in IT (0.119 [0.103, 0.144]), and lowest in mid FC regions (0.093 [0.081, 0.105], p < 0.05). When anisotropic properties were considered, stresses were significantly higher for the mid FC (p = 0.030) and IT regions (p = 0.002) and no difference was found for the shoulder or global regions. Shear (sliding) stress between fibers in each region and their proportion of maximum principal stress were: shoulder (25.8 kPa [17.1, 41.2], 12.4%), mid FC (13.9 kPa [5.8, 29.6], 13.8%), and IT (36.5 kPa [25.9, 47.3], 15.5%). Fiber structure within the FC has a marked effect on principal stresses, resulting in considerable shear stress between fibers. Fiber structure including orientation and dispersion may determine mechanical strength and thus rupture of atherosclerotic plaques.


Assuntos
Placa Aterosclerótica/fisiopatologia , Anisotropia , Artérias , Análise de Elementos Finitos , Humanos , Placa Aterosclerótica/diagnóstico por imagem , Estresse Mecânico
3.
J Mech Behav Biomed Mater ; 69: 39-49, 2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-28038405

RESUMO

Vascular grafts made by tissue engineering processes are prone to buckling and twisting, which can impede blood flow and lead to collapse of the vessel. These vascular conduits may suffer not only from insufficient tensile strength, but also from vulnerabilities related to compression, torsion, and pulsatile pressurization. Aiming to develop a tissue engineering-inspired blood conduit, composite vascular graft (cVG) prototypes were created by combining a flexible polylactic acid (PLA) knitted fabric with a soft polycaprolactone (PCL) matrix. The graft is to be populated in-situ with cellular migration and proliferation into the device. Comprehensive characterizations probed the relationship between structure and mechanical properties of the different cVG prototypes. The composite grafts exhibited major improvements in mechanical characteristics compared to single-material devices, with particular improvement in compression and torsional resistance. A commercial expanded polytetrafluoroethylene (ePTFE) vascular graft was used as a control against the proposed composite vascular grafts. CVG devices showed high tensile strength, high bursting strength, and improved suture retention. Compression, elastic recovery, and compliance were similar to those for the ePTFE graft.


Assuntos
Prótese Vascular , Teste de Materiais , Poliésteres/análise , Politetrafluoretileno/análise , Têxteis/análise , Complacência (Medida de Distensibilidade) , Desenho de Prótese , Resistência à Tração
4.
Materials (Basel) ; 9(2)2016 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-28787913

RESUMO

Whereas buckling can cause type III endoleaks, long-term twisting of a stent-graft was investigated here as a mechanism leading to type V endoleak or endotension. Two experimental device designs supported with Z-stents having strut angles of 35° or 45° were compared to a ringed control under accelerated twisting. Damage to each device was assessed and compared after different durations of twisting, with focus on damage that may allow leakage. Stent-grafts with 35° Z-stents had the most severe distortion and damage to the graft fabric. The 45° Z-stents caused less fabric damage. However, consistent stretching was still seen around the holes for sutures, which attach the stents to the graft fabric. Larger holes may become channels for fluid percolation through the wall. The ringed stent-graft had the least damage observed. Stent apexes with sharp angles appear to be responsible for major damage to the fabrics. Device manufacturers should consider stent apex angle when designing stent-grafts, and ensure their devices are resistant to twisting.

5.
J Biomech ; 47(6): 1438-46, 2014 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-24548335

RESUMO

Vascular stents are expanded in blood vessels with lumens larger than their cardiac counterparts. Extreme radial expansion significantly reduces the expanded length of some designs, resulting in insufficient lesion coverage and inaccurate placement. It is hypothesized that expansion mechanisms of a balloon-expandable stent, driven by plastic hinges, are controlled by the cell topology. This hypothesis is first tested for stent expansion using kinematic and kinetic analyses, followed by more detailed finite element (FE) calculations. Three balloon-expandable stent designs are laser micro-machined for experimental verification of the length-diameter relations predicted by the analytical and FE models. It is found that stent designs with positive, negative, or zero foreshortening over expansion phase can be designed by tailoring unit cell geometries and hence obtain desired length-diameter and pressure-diameter characteristics.


Assuntos
Desenho de Prótese , Stents , Fenômenos Biomecânicos , Vasos Sanguíneos/fisiologia , Desenho de Equipamento , Análise de Elementos Finitos , Humanos , Modelos Teóricos , Plásticos/química , Pressão , Reprodutibilidade dos Testes , Estresse Mecânico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA