Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
1.
Korean J Orthod ; 54(3): 160-170, 2024 May 25.
Artigo em Inglês | MEDLINE | ID: mdl-38800861

RESUMO

Objective: Owing to the availability of 3D software, scanners, and printers, clinicians are encouraged to produce in-office aligners. Recently, a new directprinting resin (Tera Harz TC-85DAC) has been introduced. Studies on its mechanical characteristics and biological effects have been published; however, evidence on its efficacy in orthodontic treatment remains scarce. This pilot study aimed to investigate the accuracy of teeth movement achieved with directprinted aligners. Methods: Seventeen patients (eight males and nine females) with a mean age of 27.67 ± 8.95 years, presenting with dental rotations < 30° and spaces/crowding < 5 mm, were recruited for this study. The teeth movement was planned starting from a T0 digital dental cast. The 3D direct-printed aligners were produced using Tera Harz TC-85DAC resin. Once the orthodontic treatment was completed, a final digital cast was obtained (T1). The planned teeth positions were then superimposed onto the T0 and T1 digital models. The differences between the programmed movements and the achieved overall torque, tip, rotation, and transverse dimensions were assessed using the paired t test or Wilcoxon's signed rank test. Results: The overall accuracies for torque, tip, and rotation were 67.6%, 64.2%, and 72.0%, respectively. The accuracy of the change in transverse diameter was 99.6%. Conclusions: Within the limits of the present pilot study (difficulties with abnormally shaped teeth and use of attachments), it can be concluded that 3D printed aligners can be successfully printed in-house and utilized for mildly crowded cases, with a comparable accuracy of tooth movement to that of other aligners.

2.
Medicina (Kaunas) ; 60(5)2024 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-38792929

RESUMO

Background and Objectives: The objective of this retrospective controlled study is to compare class II growing patients who underwent treatment with two different functional appliances: the Fraenkel regulator (FR-2), utilized as the control group, and the elastodontic device "Cranium Occluded Postural Multifunctional Harmonizers" (AMCOP), utilized as the test group. Materials and Methods: The study sample consisted of 52 patients with class II division I malocclusion (30 males, 22 females, mean age 8.6 ± 1.4 years) who were treated with the two different types of appliances: Group 1 (n = 27, mean age 8 [7.00, 9.00] years, 12 females, 15 males) received treatment with AMCOP, while Group 2 (n = 25, mean age 9.2 years [8.20, 10.00], 10 females, 15 males) received treatment with FR-2. The mean treatment duration for Group 1 was 28.00 [21.50, 38.00] months, while for Group 2 it was 23.70 [17.80, 27.40] months. Cephalometric analyses were performed on lateral cephalograms taken before treatment (T1) and after treatment (T2). Results: Significant intragroup differences were observed over time in Group 1 for 1^/PP. Similarly, significant intragroup differences were observed over time in Group 2 for SNB, ANB, and IMPA. Conclusions: Both treatment modalities resulted in the correction of class II malocclusion with dentoalveolar compensation, although the treatment duration with AMCOP tended to be longer on average.


Assuntos
Má Oclusão Classe II de Angle , Humanos , Masculino , Feminino , Criança , Estudos Retrospectivos , Má Oclusão Classe II de Angle/terapia , Aparelhos Ortodônticos Funcionais , Aparelhos Ortodônticos Removíveis , Cefalometria/métodos , Resultado do Tratamento
3.
Front Oral Health ; 5: 1389628, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38745852

RESUMO

Introduction: A condylion-gonion-menton (Co-Go-Me) angle threshold of 125.5° has been introduced as a predictive parameter of cephalometric mandibular response in the orthopedic treatment of growing Class II patients with functional appliances, despite some contradictions in the literature. Considering the lack of studies evaluating the role of skeletal anchorage, this study aims to reassess the threshold of 125.5° in the Co-Go-Me angle as a useful predictor in growing skeletal Class II patients treated with acrylic splint Herbst appliance and two mini-screws in the lower arch (STM2). Methods: Thirty-five consecutively treated patients (20 males, 15 females; mean age, 11.37 years) with mandibular retrusion were classified into two groups according to their Co-Go-Me baseline values (Group 1, <125.5°; Group 2, >125.5°). The STM2 protocol involved the use of the MTH Herbst appliance with an acrylic splint in the lower arch and two interradicular mini-screws as anchorage reinforcement. Cephalometric analysis was performed by the same operator for each patient at baseline (T0) and at the end of the Herbst phase (T1). The effects of time and group on the variables were assessed by a repeated-measures analysis of variance. The primary research outcome was the difference between the groups in terms of mandibular responsiveness to treatment referred to as the relative difference (T1-T0) in Co_Gn. Results: The mean duration of the treatment was 9.5 months. No statistically significant differences between groups were detected at baseline, except from the expected SN/GoMe° (p < 0.001) and Co-Go mm (p = 0.028). No statistically significant changes between groups, which were caused by the treatment, were found considering the mandibular sagittal and vertical skeletal parameters. Similarly, no statistically significant differences were found in the dental changes between the high-angle and low-angle patients, apart from the upper molar sagittal position (p = 0.013). Discussion and conclusions: The 125.5° threshold in the Co-Go-Me value was not a reliable predictive parameter for the mandibular response in growing patients treated with the MTH Herbst appliance and lower skeletal anchorage. Due to its effective control in the sagittal and vertical planes, the STM2 technique might be an appropriate protocol to use in treating skeletal Class II patients, regardless of the growth pattern.

4.
Prog Orthod ; 24(1): 20, 2023 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-37271798

RESUMO

INTRODUCTION: Maxillary expansion in patients at the end of their growth relies on the possibility to use miniscrew supported expanders to apply expansion forces directly to the midpalatal suture. Although miniscrews provide a stable anchorage unit, several studies have reported that they do not remain in exactly the same position during treatment. The aim of the present study was to analyze miniscrew position changes after the expansion using bone-borne appliances in late adolescent patients. METHODS: Nineteen patients (13 females, 6 males), with a mean age of 17.81 (SD = 4.66), were treated with a Bone-Borne Expander Device. The appliance was designed with 4 miniscrews: 2 in the anterior palatal area, at the third rugae level; 2 in the posterior area. A CBCT and an intraoral scan were obtained before treatment (T0), and then, a second CBCT was obtained after the expansion (T1). Data on peri-suture bone thickness were collected at T0, then the CBCTs were superimposed, and changes between mini-screws position on T0 and T1 were evaluated, both by linear and angular displacements. RESULTS: Significant longitudinal differences were found in the distance of the head and the tip of miniscrews measured at the occlusal plane, as well as angular changes. Correlations between displacement measurements and peri-suture bone thickness and height measurements were found as well. CONCLUSIONS: While acting as bone anchor units, miniscrews do not remain in the same position during bone-borne expansion. The amount of displacement was related to peri-sutural total bone height and cortical thickness, especially in the anterior area of the naso-frontal maxillary complex.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Procedimentos de Ancoragem Ortodôntica , Masculino , Feminino , Humanos , Adolescente , Tomografia Computadorizada de Feixe Cônico/métodos , Técnica de Expansão Palatina , Palato , Maxila/diagnóstico por imagem
5.
Clin Implant Dent Relat Res ; 25(3): 438-446, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36991573

RESUMO

INTRODUCTION: To compare the clinical outcomes of anterior single maxillary implants placed using conventional or guided implant surgery. METHODS: In this retrospective clinical study 44 patients rehabilitated with a single anterior implant in the maxillary arch were included. Twenty-four implants were inserted applying a guided surgery approach (GS), and 20 applying a conventional freehand approach (CS). Outcome measures were: implant survival rate and complications; mean bone level (MBL) evaluated at surgery (T0), after 6 weeks (6 W), and after 1 year (1Y), 2 years (2Y), 3 years (3Y), 4 years (4Y), and 5 years (5Y); patients' satisfaction evaluated through a questionnaire filled out before surgery (BS) and at 1 week, 6 W, 2Y and 5Y; Pink esthetic score (PES) and white esthetic score (WES) evaluated at 1Y, 3Y and 5 Y. Significance of differences between groups were tested by Fisher's exact test, Mann-Whitney U test, and Wilcoxon's signed rank test. RESULTS: During the 5-year follow-up there were no drop-outs and no implant failed. No significant differences between groups were found in MBL. A significant difference between groups was found in VAS scores regarding speech at 2 years, aesthetics at 6 weeks, confidence at 1 week and 6 weeks, satisfaction at T0 and at 1 W, pain/comfort at 1 W and at 6 W; all VAS scores resulted significantly improved compared to baseline. No significant differences in WES were found, while significant differences in PES scores between CS and GS groups were found at 3 and 5 years (p value = 0.023 and 0.004 respectively) with better outcomes for GS. A significant difference over time was found in PES between 5-year and one-year values. CONCLUSIONS: Guided surgery and conventional surgery implants did not show any difference in MBL during the 5-year observation period. Guided surgical procedure guarantee optimal esthetic outcome and seems able to guarantee better soft tissue result over time, even though more long-term studies are necessary to confirm this data.


Assuntos
Implantes Dentários para Um Único Dente , Implantes Dentários , Humanos , Estudos Retrospectivos , Resultado do Tratamento , Estética Dentária , Coroas , Maxila/cirurgia
6.
Am J Orthod Dentofacial Orthop ; 162(6): e312-e318, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36192323

RESUMO

INTRODUCTION: The anterior area of the palate is widely used as an insertion site for orthodontic miniscrews. These temporary anchorage devices can be placed either directly or using an insertion guide, and various kinds of digital planning and guides are currently available. This study aimed to verify if the guided procedure can guarantee the correct position of the miniscrews on the patient compared with the digital project. METHODS: Twenty-five consecutively treated patients were included in the study. Angular and linear displacements of the miniscrews were evaluated among 3 groups: the planned position, the model position, and the achieved position. RESULTS: The median achieved angle between 2 digitally planned screws was 6.22° (interquartile range: 4.35°, 9.08°) and the difference between the angles in the planning and the achievement groups was significant (P <0.001). Lateral and vertical differences were also found among the 3 groups. CONCLUSIONS: Results show that the examined workflow is clinically efficient. Differences between the digitally planned position of the orthodontic miniscrews, the control position, and the achieved position were detected both for angular and linear measurements but were not clinically significant.


Assuntos
Procedimentos de Ancoragem Ortodôntica , Humanos , Estereolitografia , Reprodutibilidade dos Testes , Parafusos Ósseos , Maxila/cirurgia
7.
Artigo em Inglês | MEDLINE | ID: mdl-35912539

RESUMO

BACKGROUND: During the debonding phase every clinician has to take care of preserving the enamel structure and tooth temperature. The objective of this study is to analyze in vitro the increase of the pulp chamber temperature and the wearing of enamel surface, during adhesive removal after debonding. METHODS: 60 extracted human teeth were selected. An orthodontic bracket was bonded on each tooth and after bracket removal, intraoral scanner pictures were used to evaluate ARI for each tooth. 3 different burs were tested: Tungsten-carbide multiple blade, Arkansas stone and Ceramic bur. A mechanical arm controlled by a dedicated software was used to reproduce a repeatable act of composite removal. To analyze in vitro the pulp chamber temperature during the composite removal procedure, teeth were treated endodontically placing a thermocouple through the root canal from the apex. A software registered temperature changes in a continuous manner. The enamel surface of every tooth was tested after the removal of composite with an optical stereoscopic microscope. RESULTS: An association existed between maximum internal pulp chamber temperature variation and irrigation (P-value < 0.0001) and between maximum internal pulp chamber temperature variation and bur type (P-value = 0.0133), with a significantly lower temperature increase produced by the Arkansas bur. A significant difference among groups was detected for ESI and EDI assessment (P-value = 0.002, P-value = 0.010). CONCLUSIONS: Considering the initial setup, temperature variation analysis showed more conservative results using the Arkansas burs with irrigation. ESI and EDI indexes showed significant enamel surface damage using Tungsten-carbide burs.

8.
Eur J Orthod ; 44(5): 530-536, 2022 09 19.
Artigo em Inglês | MEDLINE | ID: mdl-35201320

RESUMO

OBJECTIVES: This retrospective CBCT study aimed to evaluate the palatal anatomical characteristics using the third palatal ruga as a reliable clinical reference for miniscrew placement. METHODS: Thirty-six subjects (mean age17.1 y.o. ± 4.1) were randomly selected and their records (CBCT volume and maxillary digital models) were included.BlueSkyPlan CBCT software viewer (BluSkyBio, V4.7) was used to measure the following outcomes at the level of third palatal ruga, 2 mm anteriorly and 2 mm posteriorly: total bone depth, cortical bone thickness, and mucosa thickness. The outcomes were evaluated on lines perpendicular to the palatal mucosa laying on different sagittal planes: the mid-palatal plane, 2 and 4 mm paramedian planes. RESULTS: The maximum mean amount of bone depth was registered 2 mm posteriorly to the third ruga and 4 mm paramedian (9.7 mm). No significant difference was observed between the third ruga insertion site and its corresponding 2 mm posterior site. Cortical bone of palatal vault did not change significantly in anteroposterior direction for all the considered sites. Significant differences were found comparing cortical bone at the suture level with cortical bone 2-mm and 4-mm paramedian at all anteroposterior levels. Palatal mucosa increases its thickness in paramedian insertion sites, and it decreases in posterior insertion sites. CONCLUSIONS: Both third palatal ruga and 2 mm posteriorly to third ruga (4 mm paramedian) could be the optimal insertion site for palatal miniscrew placement, depending on individual anatomic conditions. The thickness of the cortical palatal bone showed, at 4 mm paramedian, optimal characteristics for miniscrew primary stability. Palatal mucosa thickness values suggest miniscrew neck extension of 2.0-2.5 mm for optimal mucosa adaptation.


Assuntos
Procedimentos de Ancoragem Ortodôntica , Adolescente , Tomografia Computadorizada de Feixe Cônico , Osso Cortical/diagnóstico por imagem , Humanos , Maxila/diagnóstico por imagem , Mucosa Bucal/diagnóstico por imagem , Palato/diagnóstico por imagem , Estudos Retrospectivos , Adulto Jovem
9.
Eur J Orthod ; 44(4): 452-457, 2022 08 16.
Artigo em Inglês | MEDLINE | ID: mdl-35028669

RESUMO

BACKGROUND: Surface treatment of miniscrews was implemented to determine whether its application increased bone-to-surface contact and enhanced the interlock between the device and the surrounding bone. OBJECTIVES: To compare the success rate of surface-treated and non-treated orthodontic miniscrews used as reinforcement of anchorage during treatment with the Herbst appliance. TRIAL DESIGN: Split-mouth design with an allocation ratio of 1:1. METHODS: Eligibility criteria to enrol patients were skeletal and dental class II patients with a retrusive chin, use of the Herbst appliance to correct malocclusion, need for skeletal anchorage using a miniscrew both in the left and right side of the mouth, absence of systemic diseases, absence of using drugs that alter bone metabolism, and good oral hygiene. Patients received self-drilling miniscrews without surface treatment and with surface treatment. Both types presented a 1.4 or 1.2 mm diameter. Miniscrews were inserted between the first molar and second premolars or between the two premolars. The force applied to the screws was an elastic chain from the head of the miniscrews to a direct button applied on the canines. The success rate of each type of miniscrew was considered the primary outcome, and the association of success with demographical, clinical, and geometrical characteristics was investigated. Differences were tested by the generalised linear mixed effects model for the split-mouth design. Differences with a P-value < 0.05 were selected as significant. RANDOMISATION: A randomisation list was created for the mouth side assignment. BLINDING: The study was single blinded with regard to the statistical analysis. RESULTS: Thirty-nine miniscrews of the non-treated type and 39 miniscrews of the surface-treated type were inserted in 39 patients (23 female and 16 male, mean age: 15.55 ± 7.91) recruited between March 2018 and December 2020 with a split-mouth study design. The mean therapy duration was 9.3 months (SD = 1.31). No differences in failure rate were observed between miniscrew types. No serious harm was observed. CONCLUSIONS: The success rate of surface-treated and non-treated miniscrews showed no significant differences. REGISTRATION: This trial was not registered.


Assuntos
Procedimentos de Ancoragem Ortodôntica , Aparelhos Ortodônticos Funcionais , Animais , Parafusos Ósseos/efeitos adversos , Feminino , Masculino , Boca , Desenho de Aparelho Ortodôntico
10.
Orthod Craniofac Res ; 25(2): 192-198, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-34344059

RESUMO

BACKGROUND: Direct and 3D-assisted methods are an available alternative when inserting temporary anchorage devices (TADs) in the anterior palate for orthodontic anchorage. This study aimed to evaluate the differences between a planned insertion versus a direct method on digital models. SETTINGS AND SAMPLE POPULATION: Seventy TADs were inserted by the direct insertion method in 35 patients who needed palatal TADs for orthodontic anchorage. For each patient, placement was independently planned by the superimposition of lateral cephalograms and corresponding plaster models. After mini-implant placement, impressions were taken with scanbodies. For the measurement of both linear and angle deviations, virtual planning models and postoperative oral scans were compared using 3D software for automatic surface registration and calculations. RESULTS: Comparing TADs positioned by the direct method and the digitally planned method, a mean linear distance was found of 2.54 ± 1.51 mm in the occlusal view and 2.41 ± 1.33 mm in the sagittal view. No significant difference has been found between TADs positioned in the right and left palatal sides. A mean distance of 7.65 ± 2.16 mm was found between the tip of the digitally planned TAD and the central incisors root apex. CONCLUSIONS: Both direct and 3D-assisted TAD insertion methods are safe and accurate in the anterior palate. However, the use of insertion guides facilitates TAD insertion, allowing less-experienced clinicians to use palatal implants.


Assuntos
Procedimentos de Ancoragem Ortodôntica , Tomografia Computadorizada de Feixe Cônico , Humanos , Imageamento Tridimensional/métodos , Procedimentos de Ancoragem Ortodôntica/métodos , Palato/diagnóstico por imagem
11.
Rev. bras. med. esporte ; 27(6): 549-552, Nov.-Dec. 2021. tab
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1351792

RESUMO

ABSTRACT Introduction: Rowers are especially prone to oral health problems due to the massive consumption of supplements and isotonic drinks that lead eating disorders, due to the need for weight control, and to the development of teeth clenching caused by the constant activation of the chewing muscles during sports activity. Objective: To evaluate the oral health status of a group of Brazilian rowers and to identify the main risk factors influencing their oral health. Methods: One hundred and twenty rowers (84 men and 36 women) with an age of 24.16 ± 5.74 years participated in this study; an average height of 1.79 ± 0.09 cm and body mass of 75.02 ± 11.64 kg were detected by means of a questionnaire focused on the main factors that influence the deterioration in athletes' oral health. Results: The dental results revealed a significant number of rowers with the oral breathing pattern (46.7%), malocclusion (65.8%), bruxism (33.3%) and noise and/or pain in the TMJ (temporomandibular joint) (20.8%). The use of supplements and isotonic drinks (48.3%) and the incidence of bleeding gums (30.83%) were also found. Conclusion: The results show the importance of making rowers aware of the relevance of oral health and the need for prevention systems, ideally including sports dentistry specialists within the sports medicine departments of rowing clubs. Level of evidence II; Retrospective study.


RESUMEN Introducción: Los remeros son especialmente propensos a sufrir problemas de salud bucodental debido al uso masivo de suplementos e isotónicos, con tendencia a trastornos alimentarios por la exigencia de control de peso y el apretamiento dental, por la constante activación de los músculos masticatorios durante la actividad deportiva. Objetivo: Evaluar el estado bucal de un grupo de remeros brasileños e identificar los principales factores de riesgo para la salud bucal de estos deportistas. Material y método: En este estudio participaron 120 remeros (84 hombres y 36 mujeres) con una edad de 24,16 ± 5,74 años; una altura de 1,79 ± 0,09 cm y una masa corporal de 75,02 ± 11,64 kg, por medio de un cuestionario que indagó sobre los principales problemas de la salud bucodental de los deportistas. Resultados: Los resultados relativos al área dental revelaron un número significativo de remeros con patrón de respiración oral (46,7%), con historia de maloclusión (65,8%), con parafunción de bruxismo (33,3%) y con ruido y/o dolor de la ATM (articulación temporomandibular) (20,8%). El uso de suplementos e isotónicos (48,3%) y la incidencia de sangrado gingival (30,83%) son también datos relevantes encontrados. Conclusión: Los resultados obtenidos muestran la importancia de concientizar a esta categoría deportiva sobre la relevancia de la salud bucodental y establecer sistemas de prevención, preferiblemente con la inclusión de un especialista en odontología deportiva en el departamento de medicina deportiva de los clubes de remo. Nivel de evidencia II; Estudio retrospectivo.


RESUMO Introdução: Os remadores são particularmente propensos a problemas de saúde oral devido ao uso generalizado de suplementos e isotônicos, tendência a distúrbios alimentares pela exigência do controle de peso e ao cerramento dos dentes causado pela ativação constante dos músculos mastigatórios durante a atividade esportiva. Objetivo: Avaliar os distúrbios orais dos remadores brasileiros e identificar os principais fatores de risco de saúde bucal desses atletas. Métodos: Participaram deste estudo 120 remadores (84 homens e 36 mulheres) com idade de 24,16 ± 5,74 anos, estatura de 1,79 ± 0,09 cm e massa corporal de 75,02 ± 11,64 kg, que foram avaliados com um questionário que investigou os principais problemas de comprometimento da saúde oral dos atletas. Resultados: Os resultados odontológicos revelaram um número significativo de remadores com padrão respiratório oral (46,7%), com histórico de maloclusão (65,8%), com parafunção oclusal de bruxismo (33,3%) e com ruído e/ou dor na ATM (articulação temporomandibular) (20,8%). O uso de suplementos e isotônicos (48,3%) e a incidência de sangramento gengival (30,83%) também são achados relevantes. Conclusão: Os resultados obtidos mostram a importância de conscientizar essa categoria esportiva sobre a relevância da saúde oral e de estabelecer sistemas de prevenção, de preferência, com a inclusão de um especialista em odontologia do esporte no departamento de medicina esportiva dos clubes de remo. Nível de evidência II; Estudo retrospectivo.

13.
Am J Orthod Dentofacial Orthop ; 159(4): e363-e375, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33573898

RESUMO

INTRODUCTION: Rapid palatal expansion is a common therapy during orthodontic treatment and could be a preliminary step for correcting different malocclusions; furthermore, this treatment could be necessary at any age. Different anchorage approaches have been proposed to obtain an effective skeletal result, although every device produces both dental and skeletal effects. This study aimed to compare the dentoskeletal effects of a bone-borne palatal expander considering 2 groups of patients of different ages. METHODS: Twenty-four patients consecutively treated were included in the study; patients were divided into 2 groups according to their age: group 1 with age ≤16 years and group 2 patients >16 years. All patients had a preexpansion cone-beam computed tomography scan; a second scan was required at the end of activations. All patients received a bone-borne appliance anchored on 4 miniscrews. RESULTS: Significant intragroup differences were found for maxillary width and dental diameters. No significant differences were found between groups with regard to longitudinal changes, except for the maxillary right plane. CONCLUSIONS: The use of bone-borne maxillary expansion was effective in generating palatal widening both in growing and young adult patients. No significant skeletal or dental differences were found between groups.


Assuntos
Má Oclusão , Técnica de Expansão Palatina , Adolescente , Tomografia Computadorizada de Feixe Cônico , Humanos , Má Oclusão/diagnóstico por imagem , Má Oclusão/terapia , Maxila/diagnóstico por imagem , Desenho de Aparelho Ortodôntico , Adulto Jovem
14.
Head Face Med ; 17(1): 1, 2021 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-33451343

RESUMO

BACKGROUND: The aim of the present study was to compare two different anchorage systems efficiency to disinclude impacted maxillary canines using as evaluation tool superimposed Cone Beam Computed Tomography (CBCTs). METHODS: The study has been conducted with two parallel groups with an allocation ratio of 1:1. Group test received treatment using as anchorage a miniscrew, control group was treated using an anchorage unit a trans palatal arch (TPA). Both groups received a calibrated traction force of 50 g. CBCT before treatment and 3 months after traction were superimposed and canine tip and root movement were evaluated in mm/month ratio. RESULTS: No differences were observed between groups for apex displacement, tip displacement and observation timespan. Twenty-two patients (12 female, 10 male, mean age:13.4 years) undergoing orthodontic treatment for impacted maxillary canines were recruited for this study. No differences were observed between groups for apex displacement, tip displacement and observation timespan. CONCLUSIONS: The present pilot study provided no evidence that indirect anchorage on miniscrews could make canine disimpaction faster than anchorage on a TPA. An apex root movement of 0.4-0.8 mm per month was found, while average canine tip movement ranged between 1.08 mm and 1.96 mm per month. No miniscrews failures were observed. TRIAL REGISTRATION: The study reports the preliminary results of the randomized clinical trial registered at www.register.clinicaltrials.gov (registration number: NCT01717417 ).


Assuntos
Dente Canino , Dente Impactado , Adolescente , Tomografia Computadorizada de Feixe Cônico , Dente Canino/diagnóstico por imagem , Feminino , Humanos , Masculino , Maxila/diagnóstico por imagem , Projetos Piloto , Dente Impactado/diagnóstico por imagem , Dente Impactado/cirurgia
15.
Orthod Craniofac Res ; 24(3): 386-395, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33274528

RESUMO

OBJECTIVES: To compare torque recordings of immediately loaded orthodontic miniscrews between insertion time and different post-placement timepoints (2 weeks, 4 weeks and removal time, respectively). SETTING AND SAMPLE POPULATION: Parallel trial with an allocation ratio of 1:1. Eligibility criteria were needs of fixed orthodontic treatment, no systemic disease and absence of using drugs altering bone metabolism. MATERIAL AND METHODS: Patients received miniscrews, 2.0 mm diameter and 10 mm length. All miniscrews underwent inter-radicular placement, and they were placed in the maxilla or in the mandible, palatally or buccally. No pre-drilling was performed. Miniscrews were loaded immediately after the insertion and were used for distalization, intrusion, extrusion, mesialization or indirect anchorage. Patients were randomly divided into three groups. For each patient, Maximum Insertion Torque (MIT) was evaluated at baseline. MIT was measured again after 2 weeks and after 4 weeks by tightening the screw a quarter of turn in Groups 1 and 2, respectively. At the end of the treatment, maximal removal torque was evaluated in Group 3. Torque variation with respect to insertion time was considered as the primary outcome. Baseline and longitudinal differences were tested using the linear mixed-effects (LME) model. RESULTS: Forty seven patients and 74 miniscrews were followed up. An association existed between maximum insertion torque and the observation time. A torque decrease of 26.9% and 30% after 2 weeks was observed for mandibular and maxillary miniscrews, respectively. After 1 month, torque values were similar to the baseline records. The overall success rate was 79.7%. No serious harm was observed. CONCLUSIONS: Maximum insertion torque undergoes a loss during the first 2 weeks, and its values may depend on the insertion site and the anchorage purpose. Removal torque value is almost the same as the initial torque after 1 month.


Assuntos
Procedimentos de Ancoragem Ortodôntica , Parafusos Ósseos , Humanos , Mandíbula , Desenho de Aparelho Ortodôntico , Torque
16.
Int J Dent ; 2020: 1018793, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32399031

RESUMO

INTRODUCTION: The Herbst device is widely used for correction of class II malocclusions; however, most of the researches carried out on the Herbst appliance in literature do not take into account patients with a different mandibular divergence. The aim of this study was to investigate the effects of Herbst on dental and skeletal structures and to evaluate possible influence of vertical facial growth patterns. METHODS: A retrospective study was conducted on lateral cephalograms of 75 growing patients (mean age: 9.9 ± 1.9 years) with class II malocclusion treated with Herbst. Subjects were divided into 3 groups using the mandibular divergence index (SN and GoMe angle). Cephalometric parameters were evaluated using the modified SO (sagittal occlusion) Pancherz's analysis. A statistical analysis was conducted to evaluate differences among groups using ANOVA. RESULTS: Our study showed differences in response to treatment depending on patient's facial vertical growth pattern. Cranial base angle and mandibular rotation were significantly different (p < 0.05) between hypodivergent patients and normodivergent patients and between hypodivergent and hyperdivergent subjects. CONCLUSION: Hypodivergent patients increased their mandibular divergence during treatment to a greater extent than normodivergents; moreover, hyperdivergent patients exhibited a decreased mandibular divergence at the end of the treatment.

17.
Minerva Stomatol ; 69(2): 79-86, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32181609

RESUMO

BACKGROUND: Class II is one of the most common malocclusions. The prevailing aspect in Class II patients is a mandibular deficiency. Various removable and fixed functional therapies are used in order to enhance the mandibular growth or position. The aim of this prospectively controlled study was to evaluate long-term dentoskeletal changes obtained by a functional appliance for Class II. METHODS: Prospective controlled study, based on a sample size calculation. 26 Class II Division 1 patients (11.8±1.5 years) were consecutively treated with the propulseur universal light (PUL) appliance and a multi bracket appliance (PG), they were compared to a sample of 26 Class II untreated patients (11.5±0.8 years) (CG). Lateral cephalograms were taken before and after the PUL therapy, and after multibracket treatment. Interaction analysis was carried out to test whether the PUL parameters in treatment groups were different according to the acquisition times, using the Linear Mixed-Effects Model. RESULTS: Significant ANB, Overjet and WITS differences existed in treatment groups according to the time. In particular, comparing to T1 vs. T0, the relative difference (RD) means in the control group were -0.34, -0.31 and 0.17 for ANB, Overjet and WITS, respectively. The corresponding RD means in the treated group PG were -1.58, -4.27 and -2.38. Comparing to T2 vs. T0, the RD means in the control group were -0.36, -0.51 and 0.63 for ANB, Overjet and WITS, respectively. While the corresponding RD means in the treated group were -2.08, -5.12 and -2.50. CONCLUSIONS: The PUL appliance successfully corrected class II malocclusion. The long term correction was mainly due to dentoalveolar effects: therapy success was 91% for overjet correction and 76% for ANB correction. During the post functional appliance period, overjet was stable in 77% of the treated subjects, and ANB in 74% of the treated subjects.


Assuntos
Má Oclusão Classe II de Angle , Má Oclusão , Aparelhos Ortodônticos Funcionais , Cefalometria , Humanos , Mandíbula , Estudos Prospectivos , Resultado do Tratamento
18.
J Orofac Orthop ; 80(6): 304-314, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31552447

RESUMO

PURPOSE: Torque control in lingual orthodontics is key to obtain optimal esthetic results. The aim of this in vitro experimental study was to verify the efficiency of the ligature-archwire-slot system in torque control using a customized lingual appliance. METHODS: An idealized cast with eight extracted human teeth was created and a set of customized lingual brackets was obtained. Tests were performed with the following wires: 0.016â€³â€¯× 0.022″ nickel-titanium (NiTi), 0.016â€³â€¯× 0.024″ stainless steel (SS), 0.017â€³â€¯× 0.025″ ßIII titanium (ßIIITi), 0.0182â€³â€¯× 0.0182″ ßIIITi, 0.018â€³â€¯× 0.025″ SS, 0.018â€³â€¯× 0.025″ NiTi, 0.018â€³â€¯× 0.025″ ßIIITi, and three types of ligatures were tested using a universal testing machine to calculate the efficiency in torque control. A blind statistical analysis was performed. RESULTS: Based on post hoc multiple comparisons, differences were found for two of the three ligatures when using the 0.016â€³â€¯× 0.022″ NiTi wires (p < 0.001 for both ligatures). When considering all ligatures, 0.018â€³â€¯× 0.025″ SS and 0.018â€³â€¯× 0.025″ ßIIITi were significantly different from all other wires (p < 0.001 in all cases). With a moment of 5 Nmm, the 0.016â€³â€¯× 0.022″ NiTi wire developed median angles of 26.7, 29.8, and 38.7° with the three ligatures, respectively, while the 0.018â€³â€¯× 0.025″ SS developed median angles of 12.9, 10.7, and 12.7°, respectively. CONCLUSIONS: The ligature type and geometry did not affect the efficiency of torque control, except for the 0.016â€³â€¯× 0.022″ NiTi wire. The wires generating the greatest moments were the 0.018â€³â€¯× 0.025″ SS and 0.018â€³â€¯× 0.025″ ßIIITi.


Assuntos
Braquetes Ortodônticos , Fios Ortodônticos , Ligas Dentárias , Análise do Estresse Dentário , Estética Dentária , Humanos , Teste de Materiais , Desenho de Aparelho Ortodôntico , Titânio , Torque
19.
Minerva Stomatol ; 68(4): 150-159, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31357848

RESUMO

BACKGROUND: An alternative approach to surgery for treating class II adult borderline patients is the non-extraction and multiloop edgewise archwire (MEAW) technique. The aim of the present study is to compare dentoskeletal effects of the orthognathic surgery with the MEAW technique. METHODS: Thirteen adults (ten women, three men; mean age, 27.8 years) were consecutively treated using the MEAW approach. The control group was made of 13 adults (nine women, four men; mean age, 26.2 years) treated by orthognathic surgery and the multibracket appliance before and after surgery. Lateral headfilms before and after all the treatments were traced for linear and angular measurements, and data were blindly analyzed. ANOVA was conducted to compare any difference over time between the two treatments. Differences over time for each variable, separately for surgery and MEAW, were assessed by Wilcoxon test. RESULTS: No significant differences between the two groups were detected at baseline. Both treatments were effective in correcting dental discrepancies. A significant difference over time between the two treatments was found in several cephalometric measurements. CONCLUSIONS: Considering the limits of the present sample the following conclusion emerged: in the MEAW group, the malocclusion correction was predominantly dentoalveolar, and a significant profile change was observed. Significant skeletal and occlusal plane changes were obtained with the orthognathic surgery approach.


Assuntos
Má Oclusão Classe II de Angle , Cirurgia Ortognática , Procedimentos Cirúrgicos Ortognáticos , Adulto , Cefalometria , Feminino , Humanos , Masculino , Aparelhos Ortodônticos Fixos , Fios Ortodônticos , Resultado do Tratamento
20.
J Mech Behav Biomed Mater ; 81: 46-51, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29482179

RESUMO

BACKGROUND: The clinical success of orthodontic miniscrews is strictly related to primary stability, which depends on bone viscoelastic properties too. In this study, we evaluated the short time mechanical response of native bone to miniscrews, by a laboratory test based on dynamic loading. METHODS: Thirty-six segments of porcine ribs were first scanned by cone-beam computerized tomography to obtain insertion-site cortical thickness, cortical and marrow bone density. Twelve different types of miniscrews were implanted in the bone samples to evaluate the elastic compliance of the implants in response to a point force applied at the screw head normally to the screw axis. The compliance was measured dynamically in a Dynamic Mechanical Analysis apparatus as the Fourier Response Function between the signals of displacement and force. The measurements were repeated in five days successive to the insertion of the miniscrew. FINDINGS: The elastic compliance was positively related to observation timepoints, but it was not related neither to the screw type nor to the value of the insertion torque. INTERPRETATION: Stability behavior is significantly related to the short time response of native bone rather than to the screw design or the insertion torque values.


Assuntos
Osso e Ossos , Teste de Materiais , Fenômenos Mecânicos , Ortodontia/instrumentação , Animais , Estresse Mecânico , Suínos , Torque
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA