Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
1.
Interv Neuroradiol ; : 15910199241245156, 2024 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-38576332

RESUMO

PURPOSE: Pulsatile tinnitus can be caused by a high-riding jugular bulb (HRJB), characterized by the superior position of the jugular bulb in the petrous temporal bone. The anatomical position and morphology of this entity make it challenging for endovascular treatment. We report our experience with two patients successfully treated with a stent-assisted Woven EndoBridge (WEB; Microvention, Tustin, CA, USA) device. MATERIALS AND METHODS: We describe two cases of HRJB in patients presenting with disabling pulsatile tinnitus. Temporary balloon occlusion of the jugular bulb prior to the intervention reduced tinnitus intensity. Both patients were subsequently treated under general anesthesia with the WEB device deployed in the HRJB which was held by a stent deployed in the sigmoid sinus. RESULTS: Both procedures were successful with good positioning of the WEB device and no procedural complications. Both patients had complete resolution of pulsatile tinnitus immediately after the procedure. Follow-up imaging showed successful occlusion of the venous cavity with a widely patent stent. CONCLUSION: Among patients with pulsatile tinnitus caused by an ipsilateral HRJB, a stent-assisted WEB device seems to be a viable endovascular option with angiographic and clinical success.

2.
Interv Neuroradiol ; : 15910199241240504, 2024 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-38529582

RESUMO

The Woven EndoBridge (WEB) is an intra-aneurysmal flow disruptor designed for the treatment of broad-based arterial aneurysms with a high safety and effectiveness profile.1, 2 It does not require concomitant antiplatelet therapy compared to other devices such as flow diverters or intracranial stents. Innominate artery pseudoaneurysms are a rare consequence of blunt traumatic injury, infection, or atherosclerotic disease.3, 4 We describe the case of an innominate artery pseudoaneurysm successfully treated with a WEB SL device instead of stenting, therefore alleviating the need for dual antiplatelet therapy. The treatment was successful and uneventful and postprocedural computed tomography angiography confirmed the complete occlusion of the pseudoaneurysm.

3.
World Neurosurg ; 185: e700-e712, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38417622

RESUMO

OBJECTIVE: Parent vessel occlusion (PVO) is a time-honored treatment for unclippable or uncoilable intracranial aneurysms. Flow diversion (FD) is a recent endovascular alternative that can occlude the aneurysm and spare the parent blood vessel. Our aim was to compare outcomes of FD with endovascular PVO. METHODS: This is a prespecified treatment subgroup analysis of the Flow diversion in Intracranial Aneurysms trial (FIAT). FIAT was an investigator-led parallel-group all-inclusive pragmatic randomized trial. For each patient, clinicians had to prespecify an alternative management option to FD before stratified randomization. We report all patients for whom PVO was selected as the best alternative treatment to FD. The primary outcome was a composite of core-lab determined angiographic occlusion or near-occlusion at 3-12 months combined with an independent clinical outcome (mRS<3). Primary analyses were intent-to-treat. There was no blinding. RESULTS: There were 45 patients (16.2% of the 278 FIAT patients randomized between 2011 and 2020 in 3 centers): 22 were randomly allocated to FD and 23 to PVO. Aneurysms were mainly large or giant (mean 22 mm) anterior circulation (mainly carotid) aneurysms. A poor primary outcome was reached in 11/22 FD (50.0%) compared to 9/23 PVO patients (39.1%) (RR: 1.28, 95% CI [0.66-2.47]; P = 0.466). Morbidity (mRS >2) at 1 year occurred in 4/22 FD and 6/23 PVO patients. Angiographic results and serious adverse events were similar. CONCLUSIONS: The comparison between PVO and FD was inconclusive. More randomized trials are needed to better determine the role of FD in large aneurysms eligible for PVO.


Assuntos
Procedimentos Endovasculares , Aneurisma Intracraniano , Humanos , Aneurisma Intracraniano/cirurgia , Aneurisma Intracraniano/diagnóstico por imagem , Procedimentos Endovasculares/métodos , Feminino , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento , Idoso , Adulto , Embolização Terapêutica/métodos , Angiografia Cerebral
5.
J Neurointerv Surg ; 2023 Oct 30.
Artigo em Inglês | MEDLINE | ID: mdl-37903560

RESUMO

Tandem occlusions, characterized by the simultaneous presence of an intracranial large vessel occlusion and extracranial carotid artery stenosis or occlusion,1 pose a unique endovascular challenge.2 3 Typically, the extracranial occlusion is a result of atherosclerotic plaque; however, dissections are also a possible cause. It is currently uncertain whether an intracranial first approach or an extracranial first approach should be employed.4 5 A new technique has been developed which allows for the simultaneous treatment of both the intracranial and the extracranial lesion.6 We describe a variation of this technique: the stent retriever for tandem acute revascularization technique (START), which consists of simultaneously treating the intracranial lesion with stent retriever and contact aspiration, and the extracranial lesion with balloon angioplasty. We present a technical video explaining all the steps of START.(video 1)neurintsurg;jnis-2023-021011v1/V1F1V1Video 1Description and example of the START.

6.
J Neurointerv Surg ; 2023 Oct 24.
Artigo em Inglês | MEDLINE | ID: mdl-37875343

RESUMO

Pulsatile tinnitus is a symptom with a potentially significant impact on the quality of life of patients.1 In some cases the pulsatile tinnitus is secondary to an arterial, arteriovenous, or a venous condition that can be treated endovascularly.2-5 One of the newly recognized entities that can cause pulsatile tinnitus is the presence of an ipsilateral aneurysmal diverticulum of the transverse sinus. The Woven EndoBridge (WEB) is an intra-aneurysmal flow disruptor for the treatment of broad-based arterial aneurysms with a high safety and effectiveness profile.3 The initial version of the WEB with a dual-layer structure evolved into a single-layer structure in two different versions (WEB SL, a barrel shape, and WEB SLS, a spherical shape).4 The WEB system does not require concomitant antiplatelet therapy, unlike other intraluminal devices such as flow diverters or intracranial stents. We describe a case of pulsatile tinnitus secondary to an aneurysmal diverticulum of the transverse sinus successfully treated with a WEB SL device instead of stent-assisted coiling, therefore alleviating the need for antiplatelets (video 1). The patient had an immediate clinical response with complete and persisting disappearance of her pulsatile tinnitus.neurintsurg;jnis-2023-020981v1/V1F1V1Video 1.

7.
J Neuroradiol ; 50(6): 600, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37699501

RESUMO

Detachable-tip microcatheters are frequently used for endovascular embolization of arteriovenous shunts. Occasionally, the detachable tip can break during navigation resulting in the loss of the microcatheter tip in a vessel, which can lead to thrombo-embolic complications and also limit further navigation into the vessel to complete treatment. We present a case of dural AV-fistula embolization that was complicated by the accidental detachment and loss of the tip of a microcatheter during navigation to injection site. The proximal tip of the broken catheter was not visible and therefore we were unable to capture its proximal part with a Snare. Ultimately, we navigated a microcatheter distal to the broken segment and successfully snared the microcatheter fragment retrogradely. (Video 1).


Assuntos
Embolização Terapêutica , Humanos , Embolização Terapêutica/efeitos adversos , Embolização Terapêutica/métodos , Catéteres/efeitos adversos , Cateterismo , Microcirurgia , Desenho de Equipamento
8.
World Neurosurg ; 179: 109-117, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37619840

RESUMO

BACKGROUND: Rotational angiography, often referred to as a "spin", is typically presented in 2D. Since rotational angiograms are composed of images acquired from multiple angles, we took advantage of this property to develop a method for converting any rotational angiogram into a 3 dimensional (3D) video. METHODS: Our aim was to develop a low cost and easily distributable solution without requiring additional hardware or altering acquisition techniques. Six previously acquired rotational angiograms from our institution were imported using custom-written code and exported as anaglyph (red-cyan) videos. RESULTS: The resulting 3D videos convey anatomical depth that is not apparent from viewing the 2D images alone. Processing time was 1.3 ± 0.6 s (mean ± SD) per angiogram. The only associated cost was $10 for red-cyan 3D glasses. Using our software, any rotational angiogram with at least 0.3 frames per degree of rotation can be converted into 3D. CONCLUSIONS: Our solution is an inexpensive and rapid method for generating stereoscopic videos from existing angiograms. It does not require any additional hardware and is readily deployable in low-resource settings. Because the videos are in anaglyph format, they are viewable on any 2 dimensional (2D) display in the interventional suite or operating room, on a mobile device, or at home.


Assuntos
Angiografia , Software , Humanos , Imageamento Tridimensional/métodos
9.
Neurointervention ; 18(1): 67-71, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36717084

RESUMO

We describe a minimally invasive endovascular approach to treat an arteriovenous fistula of the scalp. We performed a direct puncture of the lesion through the patient's scalp for liquid embolic agent injection along with external compression of the superficial temporal artery to perform a "manual pressure-cooker technique." The combination of these minimally invasive techniques resulted in an excellent clinical and radiographic outcome.

10.
Interv Neuroradiol ; 29(2): 134-140, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35112888

RESUMO

BACKGROUND: The Low-profile Visible Intraluminal Support device (LVIS Jr) has become a commonly used intracranial stent for the treatment of intracranial aneurysms. However long-term stability and effectiveness remains to be seen. The purpose of the study was to assess the long-term efficacy, safety and durability of LVIS Jr. in a retrospective multicenter registry. METHODS: Patients with saccular aneurysms treated at centers across Canada using LVIS Jr for intracranial aneurysms were included in this retrospective registry between the dates of January 2013 and April 2019. Self reported outcomes were collected and used to assess both perioperative and long term safety and effectiveness. Both univariate and multivariate analysis were performed. RESULTS: Total of 196 patients (132 Women; mean age of 57.6 years) underwent endovascular aneurysm treatment with at least 1 LVIS Jr. stent. Mean aneurysm dome size was 7.4 mm, and mean neck size of 4.3 mm. Mean clinical and imaging follow up were 950 and 899 days respectively. Class I/II was achieved in 85% on long term follow up. Periprocedural morbidity and mortality was 4.6% and 2% and additional delayed morbidity and mortality was 3% and 2.5%. Aneurysm size >10 mm was independent predictor of periprocedural complication (OR 2.59, p = 0.048) while an increased dome to neck ratio >1.5 was independent predictor of increased delayed complications (OR 3.99, p = 0.02). CONCLUSION: The LVIS Jr. intracranial stent is an effective device in the treatment of intracranial aneurysms. Satisfactory long term occlusion rates can be achieved safely with stent-assisted coil embolization.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Embolização Terapêutica , Procedimentos Endovasculares , Aneurisma Intracraniano , Humanos , Feminino , Pessoa de Meia-Idade , Aneurisma Intracraniano/terapia , Aneurisma Intracraniano/cirurgia , Estudos Retrospectivos , Aneurisma da Aorta Abdominal/cirurgia , Resultado do Tratamento , Angiografia Cerebral/métodos , Canadá , Procedimentos Endovasculares/métodos , Stents , Embolização Terapêutica/métodos , Sistema de Registros
12.
Oper Neurosurg (Hagerstown) ; 23(4): 326-333, 2022 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-36103334

RESUMO

BACKGROUND: The scanning fiber endoscope (SFE) is a novel medical imaging device that has been used in various vascular beds as a form of angioscopy, as well as in tracts and duct systems for endoluminal imaging. Owing to its miniaturized form, high resolution, and flexibility, it has demonstrated success in imaging across a wide range of diagnostic applications. OBJECTIVE: To demonstrate, by performing a third ventriculostomy and visualizing the cranial nerves and brainstem anatomy, that, without modification, the SFE can be used through a transcranial approach in a therapeutic intraventricular neurosurgical application. METHODS: A 3.7 French SFE system was used without modification on a live porcine model to perform a third ventriculostomy and acquire high-resolution images of the animal's ventricular system, cranial nerves, and brainstem. A side-by-side comparison was made with one of the current standard-of-care rigid endoscopes as a context for size and image quality. RESULTS: High-resolution video-rate imaging was used to assist the successful, uncomplicated performance of a third ventriculostomy. High-resolution endoscopic images of the brainstem and cranial nerves were acquired. CONCLUSION: Although the SFE has been shown to be a superior device for imaging, here we demonstrate its first use as a potential therapeutic device in intracranial neurosurgery.


Assuntos
Neurocirurgia , Animais , Endoscópios , Endoscopia , Procedimentos Neurocirúrgicos/métodos , Suínos , Ventriculostomia
13.
Neurohospitalist ; 12(2): 318-322, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35419159

RESUMO

We present the case of a 73-year-old woman with a 3-month history of non-traumatic thoracic myelopathy. Initial MRI showed a T6-conus T2 signal hyperintensity. Based on this presentation, and given a personal and family history of autoimmune disease, our patient was first managed as an inflammatory transverse myelitis. Subsequent worsening after lumbar puncture and steroids prompted re-evaluation, ultimately identifying the cause as a thoracic spinal dural AV fistula. Both investigation of possible transverse myelitis with lumbar puncture and empiric treatment with steroids may not only result in diagnostic delays but also precipitate venous infarction and irreversible harm. While the MRI often provides the initial diagnosis, clinical suspicion for this under-diagnosed cause of myelopathy should be raised in older patients with a more progressive thoracic myelopathy with worsening after lumbar puncture and/or steroids. Definitive and time-sensitive treatment by interventional neuroradiology or neurosurgery results in stabilization or improvement of disability in most cases.

14.
J Neurointerv Surg ; 12(12): 1153-1156, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33028673

RESUMO

BACKGROUND: The COVID-19 pandemic has changed the way medicine is practiced, including the implementation of virtual care in many specialties. In the field of interventional neuroradiology (INR), virtual clinics are an uncommon practice with minimal literature to support its use. Our objective was to report prospective, single-centre data regarding patient and physician experience with virtual INR clinics for routine follow-up appointments. METHODS: We surveyed all patients that participated in a virtual INR clinic follow-up appointment at our hospital over a 3 month period. Information gathered included length of appointment delays (ie, wait times), length of appointment times, overall satisfaction, and perceived safety metrics. A survey was also sent out to all physicians who participated in virtual clinics with similar questions. RESULTS: 118/122 patients and 6/6 physicians completed the survey. Wait times before previous in-person appointments were perceived to be much longer than virtual appointments, whereas in-person appointment times were longer. 112/118 (94.9%) patients and 4/6 (67%) physicians reported general satisfaction with their virtual clinic experience. There were 8/118 patients who felt their conditions could not be safely assessed virtually, compared with 1/6 (17%) physicians. Lastly, 72.2% of patients reported that they would prefer virtual or telephone visits in the future for non-urgent follow-up, and 5/6 (83%) of physicians reported the same. CONCLUSION: Virtual INR clinics are more efficient and are preferred among patients and physicians for non-urgent follow-up appointments. Our study demonstrates the feasibility of a virtual platform for INR care, which could be sustainable for future practice.


Assuntos
Agendamento de Consultas , Betacoronavirus , Infecções por Coronavirus/epidemiologia , Neurorradiografia/tendências , Satisfação do Paciente , Pneumonia Viral/epidemiologia , Inquéritos e Questionários , Adulto , Idoso , COVID-19 , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Neurorradiografia/métodos , Pandemias/prevenção & controle , Médicos/tendências , Estudos Prospectivos , SARS-CoV-2
15.
J Neurointerv Surg ; 11(2): 166-170, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30194108

RESUMO

BACKGROUND: Little is known about in-stent stenosis (ISS) in patients with aneurysms treated with flow diverter (FD) stents. The reported incidence in the literature varies significantly. OBJECTIVE: The aim of this study was to assess the incidence, severity, distribution, clinical significance, and possible predictors for ISS. METHODS: Between July 2012 and June 2016 we retrospectively reviewed all patients treated with SILK FDs in our center. Only cases with short-term (4±2 months) and long-term (>1 year) follow-ups with digital subtraction angiograms were included. ISS was graded as mild (<25%), moderate (25-50%) or severe (>50%). The following predictors for ISS were assessed: gender, age, the presence of subarachnoid hemorrhage, aneurysm size, location, occlusion status, and post-stenting angioplasty. RESULTS: Thirty-six patients met the inclusion criteria. At mid-term follow-up, ISS was observed in 16/36 patients (44%). Eleven patients (69%) had mild ISS, three (19%) moderate, and two (12%) severe ISS. ISS was diffuse in 11 patients (69%) and focal in five patients (31%). All patients were asymptomatic. Thirteen patients were maintained on dual antiplatelet therapy and three on aspirin alone. At long-term follow-up, complete ISS resolution was seen in 11 patients, improvement in three and worsening in two patients. No de novo ISS occurrence was observed. On univariate analysis there was no significant predictor for ISS. CONCLUSIONS: Transient ISS after FD deployment is a common asymptomatic finding on mid-term angiographic follow-up. Complete resolution or improvement at long-term follow-up is seen in most patients who are maintained on dual antiplatelet therapy.


Assuntos
Angiografia Cerebral/tendências , Oclusão de Enxerto Vascular/diagnóstico por imagem , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/terapia , Stents Metálicos Autoexpansíveis/tendências , Adulto , Idoso , Angiografia Digital/efeitos adversos , Angiografia Digital/tendências , Aspirina/administração & dosagem , Angiografia Cerebral/efeitos adversos , Feminino , Seguimentos , Oclusão de Enxerto Vascular/epidemiologia , Humanos , Incidência , Aneurisma Intracraniano/epidemiologia , Pessoa de Meia-Idade , Estudos Retrospectivos , Stents Metálicos Autoexpansíveis/efeitos adversos , Fatores de Tempo , Resultado do Tratamento
16.
Interv Neuroradiol ; 24(6): 624-630, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29871561

RESUMO

OBJECTIVE: Numerous studies have suggested a relationship between delayed occlusion of intracranial aneurysms treated with the Pipeline Embolization Device (PED) and the presence of an incorporated branch. However, in some cases, flow diversion may still be the preferred treatment option. This study sought to determine whether geometric factors pertaining to relative size and angulation of branch vessel(s) can be measured in a reliable fashion and whether they are related to occlusion rates. METHODS: Eighty aneurysms treated at a single neurovascular center from November 2008 to June 2014 were identified. Two blinded raters prospectively reviewed the imaging performed at the time of the procedure and measured the following geometric variables: inflow jet/incorporated branch direction angle and branch artery/ parent artery ratio. Delayed occlusion was defined as the absence of complete aneurysmal occlusion at one year. Analysis was performed using logistic regression and intra-class correlation co-efficient (ICC). RESULTS: Twenty-four (30%) aneurysms with 28 incorporated branches were identified. A trend toward higher inflow jet/incorporated branch direction angle was found in the group of aneurysms demonstrating delayed occlusion when compared to the group with complete occlusion. ICC revealed high correlation. Overall lower one-year occlusion rates of 53% versus 73% for aneurysms with and without incorporated branches, respectively, were also noted. CONCLUSIONS: The presence of an incorporated branch conferred a 20% absolute risk increase for delayed aneurysmal occlusion. Incorporated branches with a larger angle between the inflow jet and the incorporated branch direction exhibited a trend toward lower occlusion rates. This might be further investigated using a multicenter approach in conjunction with other potentially relevant clinical and angiographic variables.


Assuntos
Prótese Vascular , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/cirurgia , Procedimentos Neurocirúrgicos/métodos , Adulto , Idoso , Angiografia Digital , Anticoagulantes/uso terapêutico , Embolização Terapêutica/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Radiografia Intervencionista , Estudos Retrospectivos , Medição de Risco , Tomografia Computadorizada por Raios X , Resultado do Tratamento
17.
J Neurointerv Surg ; 2016 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-26962043

RESUMO

The pipeline embolization device (PED) is a well recognized treatment for intracranial aneurysms. However, uncertainty remains regarding its effects on flow alteration, which is particularly highlighted by persistently perfused aneurysmal remnants and non-regressing, non-perfused aneurysmal masses. Here we present a 68-year-old woman with an incidental giant fusiform right paraophthalmic aneurysm electively treated with a PED. After lowering her antiplatelet therapy to promote aneurysm thrombosis, she was found to have a progressively enlarging perfused aneurysmal remnant. Angiography revealed PED occlusion, but curiously the development of a peri-construct collateral channel which feeds the aneurysmal remnant, and gives rise to distal branches and contributes to middle cerebral artery flow. The large 'thrombosed' aneurysmal mass showed tiny internal vessels on cone beam CT angiography as well as florid enhancement on MRI, further confirming that apparently thrombosed remnants are biologically active and may be remodeled depending on flow demand.

18.
BMJ Case Rep ; 20162016 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-26944374

RESUMO

The pipeline embolization device (PED) is a well recognized treatment for intracranial aneurysms. However, uncertainty remains regarding its effects on flow alteration, which is particularly highlighted by persistently perfused aneurysmal remnants and non-regressing, non-perfused aneurysmal masses. Here we present a 68-year-old woman with an incidental giant fusiform right paraophthalmic aneurysm electively treated with a PED. After lowering her antiplatelet therapy to promote aneurysm thrombosis, she was found to have a progressively enlarging perfused aneurysmal remnant. Angiography revealed PED occlusion, but curiously the development of a peri-construct collateral channel which feeds the aneurysmal remnant, and gives rise to distal branches and contributes to middle cerebral artery flow. The large 'thrombosed' aneurysmal mass showed tiny internal vessels on cone beam CT angiography as well as florid enhancement on MRI, further confirming that apparently thrombosed remnants are biologically active and may be remodeled depending on flow demand.


Assuntos
Procedimentos Cirúrgicos Eletivos/efeitos adversos , Embolização Terapêutica/instrumentação , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/cirurgia , Idoso , Angiografia Cerebral/métodos , Embolização Terapêutica/métodos , Feminino , Humanos , Aneurisma Intracraniano/patologia , Imageamento por Ressonância Magnética/métodos , Artéria Cerebral Média/patologia , Trombose
19.
J Air Waste Manag Assoc ; 65(7): 844-55, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26079558

RESUMO

UNLABELLED: Energy generation and consumption are the main contributors to greenhouse gases emissions in California. Natural gas is one of the primary sources of energy in California. A study was recently conducted to develop current, reliable, and California-specific source emission factors (EFs) that could be used to establish a more accurate methane emission inventory for the California natural gas industry. Twenty-five natural gas facilities were surveyed; the surveyed equipment included wellheads (172), separators (131), dehydrators (17), piping segments (145), compressors (66), pneumatic devices (374), metering and regulating (M&R) stations (19), hatches (34), pumps (2), and customer meters (12). In total, 92,157 components were screened, including flanges (10,101), manual valves (10,765), open-ended lines (384), pressure relief valves (358), regulators (930), seals (146), threaded connections (57,061), and welded connections (12,274). Screening values (SVs) were measured using portable monitoring instruments, and Hi-Flow samplers were then used to quantify fugitive emission rates. For a given SV range, the measured leak rates might span several orders of magnitude. The correlation equations between the leak rates and SVs were derived. All the component leakage rate histograms appeared to have the same trend, with the majority of leakage rates<0.02 cubic feet per minute (cfm). Using the cumulative distribution function, the geometric mean was found to be a better indicator than the arithmetic mean, as the mean for each group of leakage rates found. For most component types, the pegged EFs for SVs of ≥10,000 ppmV and of ≥50,000 ppmV are relatively similar. The component-level average EFs derived in this study are often smaller than the corresponding ones in the 1996 U.S. Environmental Protection Agency/Gas Research Institute (EPA/GRI) study. IMPLICATIONS: Twenty-five natural gas facilities in California were surveyed to develop current, reliable, and California-specific source emission factors (EFs) for the natural gas industry. Screening values were measured by using portable monitoring instruments, and Hi-Flow samplers were then used to quantify fugitive emission rates. The component-level average EFs derived in this study are often smaller than the corresponding ones in the 1996 EPA/GRI study. The smaller EF values from this study might be partially attributable to the employment of the leak detection and repair program by most, if not all, of the facilities surveyed.


Assuntos
Poluentes Atmosféricos/química , Monitoramento Ambiental/métodos , Indústrias Extrativas e de Processamento/métodos , Metano/química , Gás Natural , California , Indústrias Extrativas e de Processamento/instrumentação , Campos de Petróleo e Gás
20.
J Neurosurg ; 123(3): 621-8, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26047409

RESUMO

OBJECT: Aneurysmal subarachnoid hemorrhage (aSAH) is associated with substantial morbidity and mortality, with better outcomes reported following endovascular coiling compared with neurosurgical clipping of the aneurysm. The authors evaluated the contribution of perioperative complications and neurological decline to patient outcomes after both aneurysm-securing procedures. METHODS: A post hoc analysis of perioperative complications from the Clazosentan to Overcome Neurological iSChemia and Infarction Occurring after Subarachnoid hemorrhage (CONSCIOUS-1) study was performed. Glasgow Coma Scale (GCS) scores for patients who underwent neurosurgical clipping and endovascular coiling were analyzed preoperatively and each day following the procedure. Complications associated with a decline in postoperative GCS scores were identified for both cohorts. Because patients were not randomized to the aneurysm-securing procedures, propensity-score matching was performed to balance selected covariates between the 2 cohorts. Using a multivariate logistic regression, the authors evaluated whether a perioperative decline in GCS scores was associated with long-term outcomes on the extended Glasgow Outcome Scale (eGOS). RESULTS: Among all enrolled subjects, as well as the propensity-matched cohort, patients who underwent clipping had a significantly greater decline in their GCS scores postoperatively than patients who underwent coiling (p = 0.0024). Multivariate analysis revealed that intraoperative hypertension (p = 0.011) and intraoperative induction of hypotension (p = 0.0044) were associated with a decline in GCS scores for patients undergoing clipping. Perioperative thromboembolism was associated with postoperative GCS decline for patients undergoing coiling (p = 0.03). On multivariate logistic regression, postoperative neurological deterioration was strongly associated with a poor eGOS score at 3 months (OR 0.86, 95% CI 0.78-0.95, p = 0.0032). CONCLUSIONS: Neurosurgical clipping following aSAH is associated with a greater perioperative decline in GCS scores than endovascular coiling, which is in turn associated with poorer long-term outcomes. These findings provide novel insight into putative mechanisms of improved outcomes following coiling, highlighting the potential importance of perioperative factors when comparing outcomes between clipping and coiling and the need to mitigate the morbidity of surgical strategies following aSAH.


Assuntos
Aneurisma Roto/terapia , Procedimentos Endovasculares/efeitos adversos , Aneurisma Intracraniano/terapia , Procedimentos Neurocirúrgicos/efeitos adversos , Complicações Pós-Operatórias/etiologia , Adulto , Aneurisma Roto/cirurgia , Método Duplo-Cego , Procedimentos Endovasculares/métodos , Feminino , Humanos , Aneurisma Intracraniano/cirurgia , Masculino , Pessoa de Meia-Idade , Procedimentos Neurocirúrgicos/métodos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA