Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Materials (Basel) ; 17(7)2024 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-38612185

RESUMO

Compared to sensible heat storage, latent heat storage provides higher energy density due to the enthalpy difference of the storage medium undergoing a phase change. However, the heat storage capability of phase change materials is opposed by low thermal conductivity. To enable sufficient heat transfer within a latent heat storage unit, phase change materials can be used in combination with a metallic matrix. One approach is the infiltration of phase change materials into additively manufactured metallic lattice structures. In this work, the fabrication of aluminum lattice structures through laser powder bed fusion is described. During fabrication, the cell size and the strut diameter were varied to obtain specimens of different geometries. To obtain the thermal conductivity of the fabricated lattices, measurements were conducted based on the transient plane source method. Additionally, finite element simulations were carried out to evaluate the effect of fabrication and measurement uncertainties. The thermal conductivity of the fabricated lattices was found to be between 3 W/(m·K) and 130 W/(m·K). The numerically and analytically performed calculations provide good estimations of the experimentally obtained data.

2.
Bioengineering (Basel) ; 11(2)2024 Feb 09.
Artigo em Inglês | MEDLINE | ID: mdl-38391656

RESUMO

In revision operations, ceramic heads of modular hip implants can be replaced. As the surface of the stem taper can be damaged, additional adapter sleeves are applied. The components are usually connected manually by the surgeon in a one-step procedure by hammer impacts. In this study, we investigated a two-step joining procedure with reproducible impaction force. First, the adapter sleeve and head were joined quasi-statically with a force of 2 kN using an assembly device. In the second step, these components were applied to the stem taper using a pulse-controlled instrument. For reference, the joints were assembled according to standard conditions using a tensile testing machine. An average pull-off force of 1309 ± 201 N was achieved for the components joined by the instrument, and the average measured values for the components joined by the testing machine were 1290 ± 140 N. All specimens achieved a force >350 N when released and therefore met the acceptance criterion defined for this study. This study showed that a modified procedure in two steps with a defined force has a positive effect on the reproducibility of the measured joining forces compared to previous studies.

3.
J Pers Med ; 14(2)2024 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-38392613

RESUMO

The use of stereotactic frames is a common practice in neurosurgical interventions such as brain biopsy and deep brain stimulation. However, conventional stereotactic frames have been shown to require modification and adaptation regarding patient and surgeon comfort as well as the increasing demand for individualized medical treatment. To meet these requirements for carrying out state-of-the-art neurosurgery, a 3D print-based, patient-specific stereotactic system was developed and examined for technical accuracy. Sixteen patient-specific frames, each with two target points, were additively manufactured from PA12 using the Multi Jet Fusion process. The 32 target points aim to maximize the variability of biopsy targets and depths for tissue sample retrieval in the brain. Following manufacturing, the frames were measured three-dimensionally using an optical scanner. The frames underwent an autoclave sterilization process prior to rescanning. The scan-generated models were compared with the planned CAD models and the deviation of the planned target points in the XY-plane, Z-direction and in the resulting direction were determined. Significantly lower (p < 0.01) deviations were observed when comparing CAD vs. print and print vs. sterile in the Z-direction (0.17 mm and 0.06 mm, respectively) than in the XY-plane (0.46 mm and 0.16 mm, respectively). The resulting target point deviation (0.51 mm) and the XY-plane (0.46 mm) are significantly higher (p < 0.01) in the CAD vs. print comparison than in the print vs. sterile comparison (0.18 mm and 0.16 mm, respectively). On average, the results from the 32 target positions examined exceeded the clinically required accuracy for a brain biopsy (2 mm) by more than four times. The patient-specific stereotaxic frames meet the requirements of modern neurosurgical navigation and make no compromises when it comes to accuracy. In addition, the material is suitable for autoclave sterilization due to resistance to distortion.

4.
Sensors (Basel) ; 24(3)2024 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-38339753

RESUMO

This paper presents a new approach to monitoring ultrasonic systems using structurally integrated piezoceramics. These are integrated into the sonotrode at different points and with different orientations. The procedure for integrating the piezoceramics into the sonotrode and their performance is experimentally investigated. We examine whether the measured signal can be used to determine the optimal operating frequency of the ultrasonic system, if integrating several piezoceramics enables discernment of the current vibration shape, and if the piezoceramics can withstand the high strains caused by the vibrations in a frequency range of approximately 20-25 kHz. The signals from the piezoceramic sensors are compared to the real-time displacement at different points of the sonotrode using a 3D laser scanning vibrometer. To evaluate the performance of the sensors, different kinds of excitation of the ultrasonic system are chosen.

5.
Bioengineering (Basel) ; 11(1)2024 Jan 12.
Artigo em Inglês | MEDLINE | ID: mdl-38247952

RESUMO

Hip implants have a modular structure which enables patient-specific adaptation but also revision of worn or damaged friction partners without compromising the implant-bone connection. To reduce complications during the extraction of ceramic inlays, this work presents a new approach of a shape-memory-alloy-actuator which enables the loosening of ceramic inlays from acetabular hip cups without ceramic chipping or damaging the metal cup. This technical in vitro study exam-ines two principles of heating currents and hot water for thermal activation of the shape-memory-alloy-actuator to generate a force between the metal cup and the ceramic inlay. Mechanical tests concerning push-in and push-out forces, deformation of the acetabular cup according to international test standards, and force generated by the actuator were generated to prove the feasibility of this new approach to ceramic inlay revision. The required disassembly force for a modular acetabular device achieved an average value of 602 N after static and 713 N after cyclic loading. The actuator can provide a push-out force up to 1951 N. In addition, it is shown that the necessary modifications to the implant modules for the implementation of the shape-memory-actuator-system do not result in any change in the mechanical properties compared to conventional systems.

6.
Bioengineering (Basel) ; 10(10)2023 Oct 11.
Artigo em Inglês | MEDLINE | ID: mdl-37892910

RESUMO

Modern hip implants have a modular design. In case of wear or other damage it allows surgeons to change the tribological partners, i.e., the acetabular liner and femoral ball. In both revision and primary surgery, the secure joining of the implant components is important for the success of the operation. The two components, namely the ceramic liner and hip cup, are connected via a conical press connection and should be concentrically aligned to avoid chipping. Malseated liners can reduce the life span in situ. The amount of the joining force, which is usually applied via a hammer, depends on the surgeon. In this study, an alternative joining method for acetabular ceramic liners in hip cups was investigated, which intends to make the process more reproducible and thus safer. For this purpose, a handpiece was used to apply a defined force impulse of 4 kN. For the concentric alignment of a ceramic liner in the hip cup, an adapter was developed based on findings via a qualitative finite element (FE) analysis. Insertion and pushout tests of the acetabular cup-liner connection were performed in the laboratory with the new instrument (handpiece with the connected adapter) to evaluate the functionality of the instrument and the reproducibility of the new insertion method. For comparison, liners and acetabular cups were joined using a testing machine according to the standard. The presented results demonstrate the technical proof-of-concept of the new joining method under laboratory conditions. They meet the acceptance criteria of established manufacturers, which proves the equivalency to proven methods for joining modular implant components. To verify the improvement of the new joining method compared to the conventionally used joining method, an application-oriented study with different surgeons and the new joining instrument under clinical conditions is necessary.

7.
JMIR Rehabil Assist Technol ; 10: e46217, 2023 Aug 04.
Artigo em Inglês | MEDLINE | ID: mdl-37540557

RESUMO

BACKGROUND: Conservative scoliosis therapy in the form of assisted physiotherapeutic scoliosis exercises is supplemented by self-contained training at home, depending on the approach (eg, Schroth, the Scientific Exercises Approach to Scoliosis). Complex exercises, lack of awareness of the importance of training, and missing supervision by therapists often lead to uncertainty and reduced motivation, which in turn reduces the success of home-based therapy. Increasing digitalization in the health care sector offers opportunities to close this gap. However, research is needed to analyze the requirements and translate the potential of digital tools into concrete solution concepts. OBJECTIVE: The aim of this study is to evaluate the potential for optimizing home-based scoliosis therapy in terms of motivation, assistive devices, and digital tools. METHODS: In collaboration with the Institute of Physiotherapy at the Jena University Hospital, a survey was initiated to address patients with scoliosis and physical therapists. A digital questionnaire was created for each target group and distributed via physiotherapies, scoliosis forums, the Bundesverband für Skoliose Selbsthilfe e. V. newsletter via a link, and a quick response code. The survey collected data on demographics, therapy, exercise habits, motivation, assistive devices, and digital tools. Descriptive statistics were used for evaluation. RESULTS: Of 141 survey participants, 72 (51.1%; n=62, 86.1%, female; n=10, 13.9%, male) patients with scoliosis with an average age of 40 (SD 17.08) years and 30 scoliosis therapists completed the respective questionnaires. The analysis of home-based therapy showed that patients with scoliosis exercise less per week (2 times or less; 45/72, 62.5%) than they are recommended to do by therapists (at least 3 times; 53/72, 73.6%). Patients indicated that their motivation could be increased by practicing together with friends and acquaintances (54/72, 75%), a supporting therapy device (48/72, 66.7%), or a digital profile (46/72, 63.9%). The most important assistive devices, which are comparatively rarely used in home-based therapy, included balance boards (20/72, 27.8%), wall bars (23/72, 31.9%), mirrors (36/72, 50%), and long bars (40/72, 55.6%). Therapists saw the greatest benefit of digital tools for scoliosis therapy in increasing motivation (26/30, 87%), improving home therapy (25/30, 83%), monitoring therapy progress (25/30, 83%), and demonstrating exercise instructions (24/30, 80%). CONCLUSIONS: In this study, we investigated whether there is any potential for improvement in home-based scoliosis therapy. For this purpose, using online questionnaires, we asked patients with scoliosis and therapists questions about the following topics: exercise habits, outpatient and home-based therapy, motivation, supportive devices, and digital tools. The results showed that a lack of motivation, suitable training equipment, and tools for self-control leads to a low training workload. From the perspective of the patients surveyed, this problem can be addressed through community training with friends or acquaintances, a supportive therapy device, and digital elements, such as apps, with training instructions and user profiles.

8.
Sensors (Basel) ; 23(14)2023 Jul 18.
Artigo em Inglês | MEDLINE | ID: mdl-37514793

RESUMO

The soft tissues of residual limb amputees are subject to large volume fluctuations over the course of a day. Volume fluctuations in residual limbs can lead to local pressure marks, causing discomfort, pain and rejection of prostheses. Existing methods for measuring interface stress encounter several limitations. A major problem is that the measurement instrumentation is applied in the sensitive interface between the prosthesis and residual limb. This paper presents the principle investigation of a non-intrusive technique to evaluate the fit of orthopaedic prosthesis sockets in transfemoral amputees based on experimentally obtained vibrational data. The proposed approach is based on changes in the dynamical behaviour detectable at the outer surface of prostheses; thus, the described interface is not affected. Based on the experimental investigations shown and the derived results, it can be concluded that structural dynamic measurements are a promising non-intrusive technique to evaluate the fit of orthopaedic prosthesis sockets in transfemoral amputee patients. The obtained resonance frequency changes of 2% are a good indicator of successful applicabilityas these changes can be detected without the need for complex measurement devices.


Assuntos
Amputados , Membros Artificiais , Ortopedia , Humanos , Desenho de Prótese , Implantação de Prótese , Cotos de Amputação
9.
JMIR Med Inform ; 11: e41614, 2023 Jan 27.
Artigo em Inglês | MEDLINE | ID: mdl-36705946

RESUMO

BACKGROUND: The electronic health record (EHR) targets systematized collection of patient-specific, electronically stored health data. The EHR is an evolving concept driven by ongoing developments and open or unclear legal issues concerning medical technologies, cross-domain data integration, and unclear access roles. Consequently, an interdisciplinary discourse based on representative pilot scenarios is required to connect previously unconnected domains. OBJECTIVE: We address cross-domain data integration including access control using the specific example of a unique device identification (UDI)-expanded hip implant. In fact, the integration of technical focus data into the hospital information system (HIS) is considered based on surgically relevant information. Moreover, the acquisition of social focus data based on mobile health (mHealth) is addressed, covering data integration and networking with therapeutic intervention and acute diagnostics data. METHODS: In addition to the additive manufacturing of a hip implant with the integration of a UDI, we built a database that combines database technology and a wrapper layer known from extract, transform, load systems and brings it into a SQL database, WEB application programming interface (API) layer (back end), interface layer (rest API), and front end. It also provides semantic integration through connection mechanisms between data elements. RESULTS: A hip implant is approached by design, production, and verification while linking operation-relevant specifics like implant-bone fit by merging patient-specific image material (computed tomography, magnetic resonance imaging, or a biomodel) and the digital implant twin for well-founded selection pairing. This decision-facilitating linkage, which improves surgical planning, relates to patient-specific postoperative influencing factors during the healing phase. A unique product identification approach is presented, allowing a postoperative read-out with state-of-the-art hospital technology while enabling future access scenarios for patient and implant data. The latter was considered from the manufacturing perspective using the process manufacturing chain for a (patient-specific) implant to identify quality-relevant data for later access. In addition, sensor concepts were identified to use to monitor the patient-implant interaction during the healing phase using wearables, for example. A data aggregation and integration concept for heterogeneous data sources from the considered focus domains is also presented. Finally, a hierarchical data access concept is shown, protecting sensitive patient data from misuse using existing scenarios. CONCLUSIONS: Personalized medicine requires cross-domain linkage of data, which, in turn, require an appropriate data infrastructure and adequate hierarchical data access solutions in a shared and federated data space. The hip implant is used as an example for the usefulness of cross-domain data linkage since it bundles social, medical, and technical aspects of the implantation. It is necessary to open existing databases using interfaces for secure integration of data from end devices and to assure availability through suitable access models while guaranteeing long-term, independent data persistence. A suitable strategy requires the combination of technical solutions from the areas of identity and trust, federated data storage, cryptographic procedures, and software engineering as well as organizational changes.

10.
Sensors (Basel) ; 22(22)2022 Nov 16.
Artigo em Inglês | MEDLINE | ID: mdl-36433447

RESUMO

This paper presents a new approach to the structural integration of piezoceramics into thin-walled steel components for condition-monitoring applications. The procedure for integrating the sensors into metal components is described, and their functionality is experimentally examined with a 2 mm-thick steel sheet. The signal quality of the produced sensors is investigated in a frequency range from 100 Hz to 50,000 Hz and is compared with the results of piezo patches and strain gauges under the same conditions. The results show that due to a higher signal-to-noise ratio and a better coherence, the structurally integrated piezoceramics and the piezo patches are more qualified sensors for vibration measurement in the examined frequency range than the strain gauges. The measurements also indicate that the patches provide higher amplitudes for the frequency range up to 20 kHz. Beyond that, up to 40 kHz, the integrated sensors supplied higher amplitudes. The better signal quality in different frequency ranges as well as the different manufacturing and application methods can be interpreted as an advantage or disadvantage depending on the boundary conditions of the condition-monitoring system. In summary, structural integrated piezoceramics extend the options of monitoring technology.

11.
Sensors (Basel) ; 22(10)2022 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-35632205

RESUMO

With a growing number of electronic devices surrounding our daily life, it becomes increasingly important to create solutions for clear and simple communication and interaction at the human machine interface (HMI). Haptic feedback solutions play an important role as they give a clear direct link and response to the user. This work demonstrates multifunctional haptic feedback devices based on fully printed piezoelectric transducers realized with functional polymers on thin paper substrate. The devices are flexible; lightweight and show very high out-of-plane deflection of 213 µm at a moderate driving voltage of 50 Vrms (root mean square) achieved by an innovative multilayer design with up to five individually controllable active layers. The device creates a very clear haptic sensation to the human skin with a blocking force of 0.6 N at the resonance frequency of 320 Hz, which is located in the most sensitive range of the human fingertip. Additionally the transducer generates audible information above two kilohertz with a remarkable high sound pressure level. Thus the paper-based approach can be used for interactive displays in combination with touch sensation; sound and color prints. The work gives insights into the manufacturing process; the electrical characteristics; and an in-depth analysis of the 3D deflection of the device under variable conditions.


Assuntos
Tecnologia Háptica , Tato , Desenho de Equipamento , Retroalimentação , Humanos , Som , Tato/fisiologia , Transdutores , Interface Usuário-Computador
12.
Biomed Eng Online ; 21(1): 3, 2022 Jan 11.
Artigo em Inglês | MEDLINE | ID: mdl-35012556

RESUMO

BACKGROUND: Demographic change is leading to an increase in the number of osteoporotic patients, so a rethink is required in implantology in order to be able to guarantee adequate anchoring stability in the bone. The functional modification of conventional standard screw implants using superelastic, structured Ti6Al4V anchoring elements promises great potential for increasing anchoring stability. METHODS: For this purpose, conventional screw implants were mechanically machined and extended so that structured-superelastic-positionable-Ti6Al4V anchoring elements could be used. The novel implants were investigated with three tests. The setup of the anchoring elements was investigated in CT studies in an artificial bone. In a subsequent simplified handling test, the handling of the functional samples was evaluated under surgical conditions. The anchorage stability compared to standard screw implants was investigated in a final pullout test according to ASTM F543-the international for the standard specification and test methods for metallic medical bone screws. RESULTS: The functionalization of conventional screw implants with structured superelastic Ti6Al4V anchoring elements is technically realizable. It was demonstrated that the anchoring elements can be set up in the artificial bone without any problems. The anchorage mechanism is easy to handle under operating conditions. The first simplified handling test showed that at the current point of the investigations, the anchoring elements have no negative influence on the surgical procedure (especially under the focus of screw implantation). Compared to conventional standard screws, more mechanical work is required to remove the functional patterns completely from the bone. CONCLUSION: In summary, it was shown that conventional standard screw implants can be functionalized with Ti6Al4V-structured NiTi anchoring elements and the new type of screws are suitable for orthopedic and neurosurgical use. A first biomechanical test showed that the anchoring stability could be increased by the anchoring elements.


Assuntos
Parafusos Ósseos , Osso e Ossos , Ligas , Fenômenos Biomecânicos , Humanos , Teste de Materiais
13.
Materials (Basel) ; 14(17)2021 Sep 06.
Artigo em Inglês | MEDLINE | ID: mdl-34501197

RESUMO

Minimally invasive surgery is increasingly used in many medical operations because of the benefits for the patients. However, for the surgeons, accessing the situs through a small incision or natural orifice comes with a reduction of the degrees of freedom of the instrument. Due to friction of the mechanical coupling, the haptic feedback lacks sensitivity that could lead to damage of the tissue. The approach of this work to overcome these problems is to develop a control concept for position control and force estimation with shape memory alloys (SMA) which could offer haptic feedback in a novel handheld instrument. The concept aims to bridge the gap between manually actuated laparoscopic instruments and surgical robots. Nickel-titanium shape memory alloys are used for actuation because of their high specific energy density. The work includes the manufacturing of a functional model as a proof of concept comprising the development of a suitable forceps mechanism and electronic circuit for position control and gripping force measurement, as well as designing an ergonomic user interface with haptic force feedback.

14.
Materials (Basel) ; 14(11)2021 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-34198784

RESUMO

The demographic change in and the higher incidence of degenerative bone disease have resulted in an increase in the number of patients with osteoporotic bone tissue causing. amongst other issues, implant loosening. Revision surgery to treat and correct the loosenings should be avoided, because of the additional patient stress and high treatment costs. Shape memory alloys (SMA) can help to increase the anchorage stability of implants due to their superelastic behavior. The present study investigates the potential of hybridizing NiTi SMA sheets with additively manufactured Ti6Al4V anchoring structures using laser powder bed fusion (LPBF) technology to functionalize a pedicle screw. Different scanning strategies are evaluated, aiming for minimized warpage of the NiTi SMA sheet. For biomechanical tests, functional samples were manufactured. A good connection between the additively manufactured Ti6Al4V anchoring structures and NiTi SMA substrate could be observed though crack formation occurring at the transition area between the two materials. These cracks do not propagate during biomechanical testing, nor do they lead to flaking structures. In summary, the hybrid manufacturing of a NiTi SMA substrate with additively manufactured Ti6Al4V structures is suitable for medical implants.

15.
Sensors (Basel) ; 21(11)2021 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-34073104

RESUMO

The wear comfort of a prosthesis is of great importance for amputee patients. The wear comfort can be affected by changes in the interface between the residual limb and prosthesis socket, which can be caused by time-dependent volume fluctuations of the tissue, leading to unwanted local pressure marks. The basis to ensure time-independent wear comfort of a prosthesis is to identify these changes. Common techniques for identifying these variations have a negative impact on the sensitive interface between the residual limb and prosthesis. The following paper contains a proof of concept for the detection of local pressure marks without affecting the described interface using structural dynamics measurements, exemplarily shown at a prosthetic socket for transfemoral amputees in a test bench scenario. The dynamical behaviour of the investigated system is analysed in the form of frequency response functions acquired for different pressure locations and preloads using an impact hammer for excitation and a triaxial acceleration sensor. The frequency response functions show major changes for the various boundary conditions with respect to their frequency-dependent compositions. The results demonstrate how the utilised method enables the identification of changes in local pressure marks regarding the variation of position and magnitude.


Assuntos
Amputados , Membros Artificiais , Cotos de Amputação , Extremidades , Humanos , Desenho de Prótese , Implantação de Prótese
16.
Materials (Basel) ; 14(6)2021 Mar 10.
Artigo em Inglês | MEDLINE | ID: mdl-33802017

RESUMO

The current article proposes a concept for the additive manufacturing of rubber components using extrusion-based 3D printing, in which an additional medium is added to ensure the maintenance of shape within the elastomeric structure during the additive manufacturing process and in the subsequent vulcanization process. Specific requirements for the dimensional stabilization of the media were defined and suitable media were derived. Silicone rubber, molding sand, and plaster were examined in experimental vulcanization tests for their suitability as possible media with regard to shape retention. Selected rubber geometries made of NBR were embedded in these media to undergo the vulcanization process. The results show a significant influence of the media on the heating times. All media were able to ensure that the rubber geometries maintained their shape during vulcanization. Nevertheless, some side effects were found. The silicone rubber did not cure properly around the rubber sample. Therefore, it was difficult to remove it from the rubber after vulcanization. The molding sand caused an increased surface roughness on the rubber. Plaster changed the glossy surfaces at the beginning to a matte one after vulcanization and residuals were difficult to remove. However, all media can serve as stabilization media with specific changes.

17.
Polymers (Basel) ; 12(10)2020 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-33019723

RESUMO

The dissemination and use of additive processes are growing rapidly. Nevertheless, for the material class of elastomers made of vulcanizable rubber, there is still no technical solution for producing them using 3D printing. Therefore, this paper deals with the basic investigations to develop an approach for rubber printing. For this purpose, a fused deposition modeling (FDM) 3D printer is modified with a screw extruder. Tests are carried out to identify the optimal printing parameters. Afterwards, test prints are performed for the deposition of rubber strands on top of each other and for the fabrication of simple two-dimensional geometries. The material behavior during printing, the printing quality as well as occurrences of deviations in the geometries are evaluated. The results show that the realization of 3D rubber printing is possible. However, there is still a need for research to stabilize the layers during the printing process. Additionally, further studies are necessary to determine the optimum parameters for traverse speed and material discharge, especially on contours.

18.
Z Orthop Unfall ; 158(3): 318-332, 2020 Jun.
Artigo em Inglês, Alemão | MEDLINE | ID: mdl-31404938

RESUMO

BACKGROUND: The FED method (Fixation, Elongation, Derotation) is a treatment method approach to Patients with scoliosis. The FED method is especially established in Spain and Poland, whereby in Germany it is less well-known. Nevertheless the FED method is within the scope of a research project (Project Number: 19200 BR/3). The purpose of the paper is to characterize the FED method and to highlight the specificities in contrast to the Schroth method, which is international established and especially in Germany. METHODS: This systematic literature research was conducted in Nov 2017-Jan 2018. Therefore common medical and physiotherapeutic databases were used. Furthermore there was a hand search in selected scientific journals. Only a small number of relevant references were identified. That is why the respective authors were asked to provide the full-texts of their papers and to recommend further references. RESULTS: A total of 378 references were identified. After removing duplicates and the content-related selection, 19 references were deemed to be relevant. Based on the analysis of this relevant literature, the FED method was comprehensively characterized. First of all the general structure of the FED method and the scientific evidence for its effectiveness was described. And as a result of the literature research, the operating principles of the FED method were pointed out. Then these operating principles were discussed in comparison with the Schroth method. The Schroth method based on sensomotoric and kinesthetic principles and the correction of the pathologic posture was performed by selective muscle activation and breathing-pattern. Thus, the posture correction will be performed by the patients (auto correction). Compared to the Schroth method, the FED method implements the posture correction by the FED-device. This correction is influenced by mechanical forces with a comparatively high strength and intensity. The repetitive mechanical correction stimulates the sensomotoric system. And due to trophic/biochemical adaptations, the physiological bone growth will be stimulated. CONCLUSION: In total the authors want to clarify, that both treatment methods (Schroth method, FED method) supposed to be applied in consideration of the preconditions of the patients and the pursue of the different treatment goals. Thus, the implementation of treatment methods should be used according to the individual treatment demand and on different stages in the treatment process.


Assuntos
Modalidades de Fisioterapia , Escoliose , Terapia por Exercício , Alemanha , Humanos , Polônia , Postura , Escoliose/terapia , Resultado do Tratamento
19.
Res Vet Sci ; 124: 79-84, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30856434

RESUMO

The treatment of intracranial lesions requires a precise diagnosis with subsequent identification of an adequate therapeutic approach. Stereotactic tumor biopsy may be considered the safest neurosurgical procedure in terms of anticipated results and potential surgical complications. The aim of the present paper was to demonstrate a new method of stereotactic biopsy, based on a patient-specific 3D printed platform in dogs. The system was tested on two canine cadavers, a small (Shih Tzu) and a large (Labrador) breed. Imaginary biopsy targets were defined in a superficial (caudate nucleus) and a deep (piriform lobe) position. Based on 3 Tesla MRI, individualized stereotactic platforms were designed using a semi-automatic approach, and manufactured additively using ABS M30. A pre- and intra-operative CT was performed to compare the planned vs. the realized needle position for precision analyses of the procedure. The target points varied with a precision between 0.09 mm and 0.48 mm. Manufacturing time required 480 to 700 min per platform. The presented patient-specific stereotactic system seems a suitable instrument for application in small animal neurosurgery. In particular, the implementation of relevant stereotactic data may help performing the procedure in rapid sequence and with higher precision than currently-used systems. Required adjustments and adaptions to the respective anatomical conditions are omitted and make the procedure reliable and safe.


Assuntos
Biópsia/veterinária , Encéfalo/patologia , Impressão Tridimensional , Técnicas Estereotáxicas/veterinária , Animais , Biópsia/instrumentação , Biópsia/métodos , Cadáver , Cães , Técnicas Estereotáxicas/instrumentação
20.
Int J Neurosci ; 129(8): 770-775, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30621502

RESUMO

Background: At present, there are no meaningful and sophisticated computer games that simultaneously allow the treatment of movement disorders such as Parkinson's syndrome. In particular, there are no systems to consider the severity of the disease and the physical skills of the patient. Methods: A computer game using the Microsoft Kinect as markerless sensor for the 3 D recognition of the patient's movement was developed to support the rehabilitation. The scenario of a basketball game was created after determining that the movement like throwing a ball and the correct posture of the body are important. A study based on system usability was performed with 15 patients to evaluate the system. Results: The technical feasibility of a computer-assisted training system for supporting patients with Parkinson's disease has been demonstrated. No markers on the patient are required for movement detection and allow a user-friendly handling. Regarding the usability study, the patients were accepting of such a system and its at-home use and symptoms like 'freezing' and the Pisa syndrome can be treated. Conclusions: The physiotherapist can be assisted by the developed rehabilitation system. An objective measurement of the patient's training progress delivers valuable information to adjust the training sessions for every patient individually. Due to its modular character, the system can also be applied to other diseases or sports injuries and offers the basis for further development.


Assuntos
Biorretroalimentação Psicológica/métodos , Reabilitação Neurológica/métodos , Doença de Parkinson/reabilitação , Terapia Assistida por Computador/métodos , Jogos de Vídeo , Idoso , Idoso de 80 Anos ou mais , Biorretroalimentação Psicológica/instrumentação , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reabilitação Neurológica/instrumentação , Terapia Assistida por Computador/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA