1.
Micromachines (Basel) ; 15(4)2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38675271

RESUMO

In this paper, we proposed an efficient and high-precision process for fabricating large-area microlens arrays using thermal reflow combined with ICP etching. When the temperature rises above the glass transition temperature, the polymer cylinder will reflow into a smooth hemisphere due to the surface tension effect. The dimensional differences generated after reflow can be corrected using etching selectivity in the following ICP etching process, which transfers the microstructure on the photoresist to the substrate. The volume variation before and after reflow, as well as the effect of etching selectivity using process parameters, such as RF power and gas flow, were explored. Due to the surface tension effect and the simultaneous molding of all microlens units, machining a 3.84 × 3.84 mm2 silicon microlens array required only 3 min of reflow and 15 min of ICP etching with an extremely low average surface roughness Sa of 1.2 nm.