Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Cardiovasc Intervent Radiol ; 44(3): 368-375, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33225377

RESUMO

PURPOSE: To report additional endpoints, including 2-year primary patency, patient outcomes, and safety results, as well as the initial assessment of hypoechogenic halo from the IMPERIAL Randomized Controlled Trial (RCT). MATERIALS AND METHODS: IMPERIAL RCT is a prospective, randomized (2:1), multicenter study of patients with symptomatic femoropopliteal artery lesions (length 30-140 mm, Rutherford category 2-4) treated with the Eluvia paclitaxel-eluting nitinol stent or the Zilver PTX paclitaxel-coated stent. Two-year follow-up included patency, safety, and mortality assessments and core laboratory-reviewed B-mode ultrasound imaging to screen for hypoechogenic halo in the stented segment, and assess blood flow. RESULTS: At 24 months, all-cause mortality was 7.1% (21/295) for Eluvia and 8.3% (12/145) for Zilver PTX (P = 0.6649). The clinically driven target lesion revascularization rate was significantly less for patients treated with Eluvia vs Zilver PTX (12.7% vs 20.1%; P = 0.0495). The Kaplan-Meier estimate of primary patency at 24 months was 83.0% for Eluvia and 77.1% for Zilver PTX (log rank P = 0.1008). Transverse ultrasound imaging was implemented during the 24-month follow-up window and was evaluable for 27.5% (128/465) of patients. Hypoechogenic halo prevalence rates did not differ significantly between Eluvia and Zilver PTX study arms (33.7% [29/86] vs 21.4% [9/42]; P = 0.153). In no case was flow documented within the halo; no adverse events were associated with these ultrasound findings. CONCLUSION: Two-year follow-up suggests a sustained advantage for Eluvia for avoiding target lesion revascularization. Initial hypoechogenic halo assessment showed no difference in prevalence between the study arms, no flow within the halo, and no associated adverse events. CLINICAL TRIAL REGISTRATION: clinicaltrials.gov identifier NCT02574481. Date of registration: October 14, 2015. LEVEL OF EVIDENCE: Level 1; randomized controlled trial.


Assuntos
Stents Farmacológicos , Procedimentos Endovasculares/métodos , Artéria Femoral/cirurgia , Paclitaxel/administração & dosagem , Doença Arterial Periférica/terapia , Artéria Poplítea/cirurgia , Idoso , Feminino , Artéria Femoral/fisiopatologia , Seguimentos , Humanos , Masculino , Artéria Poplítea/fisiopatologia , Estudos Prospectivos , Resultado do Tratamento , Grau de Desobstrução Vascular
2.
JACC Cardiovasc Interv ; 7(5): 510-8, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24852804

RESUMO

OBJECTIVES: The ORBIT II (Evaluate the Safety and Efficacy of OAS in Treating Severely Calcified Coronary Lesions) trial evaluated the safety and efficacy of the coronary Orbital Atherectomy System (OAS) to prepare de novo, severely calcified coronary lesions for stent placement. BACKGROUND: Despite advances in interventional techniques, treatment of calcified coronary lesions remains a challenge. Stent placement in these lesions may result in stent underexpansion, malapposition, and procedural complications. METHODS: ORBIT II is a prospective, multicenter, nonblinded clinical trial that enrolled 443 consecutive patients with severely calcified coronary lesions at 49 U.S. sites from May 25, 2010, to November 26, 2012. Investigators used the centrifugal action of the OAS diamond-coated crown to modify calcified lesions prior to stent placement. RESULTS: The pre-procedure mean minimal lumen diameter of 0.5 mm increased to 2.9 mm after the procedure. The primary safety endpoint was 89.6% freedom from 30-day major adverse cardiac events compared with the performance goal of 83%. The primary efficacy endpoint (residual stenosis <50% post-stent without in-hospital major adverse cardiac events) was 88.9% compared with the performance goal of 82%. Stent delivery occurred successfully in 97.7% of cases with <50% stenosis in 98.6% of subjects. Low rates of in-hospital Q-wave myocardial infarction (0.7%), cardiac death (0.2%), and target vessel revascularization (0.7%) were reported. CONCLUSIONS: The ORBIT II coronary OAS trial met both the primary safety and efficacy endpoints by significant margins. Preparation of severely calcified plaque with the OAS not only helped facilitate stent delivery, but improved both acute and 30-day clinical outcomes compared with the outcomes of historic control subjects in this difficult-to-treat patient population. (Evaluate the Safety and Efficacy of OAS in Treating Severely Calcified Coronary Lesions [ORBIT II]; NCT01092416).


Assuntos
Aterectomia Coronária/instrumentação , Estenose Coronária/terapia , Calcificação Vascular/terapia , Idoso , Aterectomia Coronária/efeitos adversos , Estenose Coronária/diagnóstico , Estenose Coronária/mortalidade , Desenho de Equipamento , Feminino , Humanos , Masculino , Infarto do Miocárdio/etiologia , Infarto do Miocárdio/mortalidade , Intervenção Coronária Percutânea/instrumentação , Estudos Prospectivos , Índice de Gravidade de Doença , Stents , Fatores de Tempo , Resultado do Tratamento , Estados Unidos , Calcificação Vascular/diagnóstico , Calcificação Vascular/mortalidade
3.
Am J Cardiol ; 99(12): 1680-6, 2007 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-17560875

RESUMO

The impact of time to treatment on outcomes after primary percutaneous coronary intervention (PCI) is controversial, and there are few data about time to treatment and infarct size. The EMERALD trial randomly assigned 501 high-risk patients with ST-elevation myocardial infarction undergoing primary PCI to stenting with or without GuardWire (Medtronic, Santa Rosa, California) distal protection. Infarct size using sestamibi imaging at 5 to 14 days and clinical outcomes were examined by time to treatment. There were no differences in outcomes between distal protection and control patients. Shorter time to reperfusion (<2 vs 2 to 3 vs >3 to 4 vs >4 hours) was associated with smaller infarct size (2% vs 9% vs 12% vs 11%, p=0.026), trends for better myocardial blush (p=0.08), and lower 6-month mortality rates (0% vs 0% vs 2.4% vs 5.3%, p=0.06). Incremental delays in reperfusion after 2 hours had little impact on infarct size. Shorter time to reperfusion impacted on infarct size in patients with anterior infarction (0% vs 17% vs 20.5% vs 30.5%, p=0.026), but not nonanterior infarction (3% vs 7% vs 7.5% vs 10%, p=0.23, p=0.022 for interaction). In conclusion, very early reperfusion with primary PCI is associated with smaller infarct size and has a much greater impact in anterior versus nonanterior infarction. Incremental delays in reperfusion after 2 hours have less effect on infarct size. These data have implications regarding the triage of patients for primary PCI.


Assuntos
Angioplastia Coronária com Balão , Circulação Coronária/fisiologia , Infarto do Miocárdio/terapia , Miocárdio/patologia , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/patologia , Infarto do Miocárdio/fisiopatologia , Reperfusão Miocárdica , Estudos Prospectivos , Fatores de Tempo , Resultado do Tratamento
4.
JAMA ; 293(9): 1063-72, 2005 Mar 02.
Artigo em Inglês | MEDLINE | ID: mdl-15741528

RESUMO

CONTEXT: Atheromatous and thrombotic embolization during percutaneous coronary intervention (PCI) in acute myocardial infarction is common and may result in microcirculatory dysfunction, the prevention of which may improve reperfusion success, reduce infarct size, and enhance event-free survival. OBJECTIVE: To determine whether protection of the distal microcirculation from thromboembolic debris liberated during primary PCI results in improved reperfusion and decreased infarct size. DESIGN, SETTING, AND PATIENTS: Prospective randomized controlled trial at 38 academic and community-based institutions in 7 countries enrolling 501 patients aged 18 years or older with ST-segment elevation myocardial infarction (STEMI) presenting within 6 hours of symptom onset and undergoing primary PCI or rescue intervention after failed thrombolysis. INTERVENTIONS: Patients were randomized between May 20, 2002, and November 21, 2003, to receive PCI with a balloon occlusion and aspiration distal microcirculatory protection system vs angioplasty without distal protection. MAIN OUTCOME MEASURES: Coprimary end points were ST-segment resolution (STR) measured 30 minutes after PCI by continuous Holter monitoring and infarct size measured by technetium Tc 99m sestamibi imaging between days 5 and 14. Secondary end points included major adverse cardiac events. RESULTS: Among 252 patients assigned to distal protection, aspiration was performed in 97% (242/251), all angioplasty balloon inflations were fully protected in 79% (193/245), and visible debris was retrieved from 73% (182/250). Complete STR was achieved in a similar proportion reperfused with vs without distal protection (63.3% [152/240] vs 61.9% [148/239], respectively; absolute difference, 1.4% [95% confidence interval, -7.7% to 10.5%; P = .78]), and left ventricular infarct size was similar in both groups (median, 12.0% [n = 229] vs 9.5% [n = 208], respectively; P = .15). Major adverse cardiac events at 6 months occurred with similar frequency in the distal protection and control groups (10.0% vs 11.0%, respectively; P = .66). CONCLUSIONS: A distal balloon occlusion and aspiration system effectively retrieves embolic debris in most patients with acute STEMI undergoing emergent PCI. Nonetheless, distal embolic protection did not result in improved microvascular flow, greater reperfusion success, reduced infarct size, or enhanced event-free survival.


Assuntos
Angioplastia Coronária com Balão , Infarto do Miocárdio/terapia , Sucção , Idoso , Eletrocardiografia Ambulatorial , Feminino , Humanos , Masculino , Microcirculação , Pessoa de Meia-Idade , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/fisiopatologia , Estudos Prospectivos , Compostos Radiofarmacêuticos/uso terapêutico , Tecnécio Tc 99m Sestamibi , Tromboembolia , Tomografia Computadorizada de Emissão de Fóton Único
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA