Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
J Appl Crystallogr ; 55(Pt 3): 621-625, 2022 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-35719306

RESUMO

Electronic or catalytic properties can be modified at the nanoscale level. Engineering efficient and specific nanomaterials requires the ability to study their complex structure-property relationships. Here, Bragg coherent diffraction imaging was used to measure the three-dimensional shape and strain of platinum nanoparticles with a diameter smaller than 30 nm, i.e. significantly smaller than any previous study. This was made possible by the realization of the Extremely Brilliant Source of ESRF, The European Synchrotron. This work demonstrates the feasibility of imaging the complex structure of very small particles in three dimensions and paves the way towards the observation of realistic catalytic particles.

2.
Sci Rep ; 8(1): 11533, 2018 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-30069062

RESUMO

A dissipative magnetic soliton, or magnetic droplet, is a structure that has been predicted to exist within a thin magnetic layer when non-linearity is balanced by dispersion, and a driving force counteracts the inherent damping of the spin precession. Such a soliton can be formed beneath a nano-contact (NC) that delivers a large spin-polarized current density into a magnetic layer with perpendicular magnetic anisotropy. Although the existence of droplets has been confirmed from electrical measurements and by micromagnetic simulations, only a few attempts have been made to directly observe the magnetic landscape that sustains these structures, and then only for a restricted set of experimental parameter values. In this work we use and x-ray holography technique HERALDO, to image the magnetic structure of the [Co/Ni]x4 multilayer within a NC orthogonal pseudo spin-valve, for different range of magnetic fields and injected electric currents. The magnetic configuration imaged at -33 mA and 0.3 T for devices with 90 nm NC diameter reveals a structure that is within the range of current where the droplet soliton exist based on our electrical measurements and have it is consistent with the expected size of the droplet (∼100 nm diameter) and its spatial position within the sample. We also report the magnetisation configurations observed at lower DC currents in the presence of fields (0-50 mT), where it is expected to observe regimes of the unstable droplet formation.

3.
Nano Lett ; 17(11): 6696-6701, 2017 11 08.
Artigo em Inglês | MEDLINE | ID: mdl-29052998

RESUMO

Structural quality and stability of nanocrystals are fundamental problems that bear important consequences for the performances of small-scale devices. Indeed, at the nanoscale, their functional properties are largely influenced by elastic strain and depend critically on the presence of crystal defects. It is thus of prime importance to be able to monitor, by noninvasive means, the stability of the microstructure of nano-objects against external stimuli such as mechanical load. Here we demonstrate the potential of Bragg coherent diffraction imaging for such measurements, by imaging in 3D the evolution of the microstructure of a nanocrystal exposed to in situ mechanical loading. Not only could we observe the evolution of the internal strain field after successive loadings, but we also evidenced a transient microstructure hosting a stable dislocation loop. The latter is fully characterized from its characteristic displacement field. The mechanical behavior of this small crystal is clearly at odds with what happens in bulk materials where many dislocations interact. Moreover, this original in situ experiment opens interesting possibilities for the investigation of plastic deformation at the nanoscale.

4.
Sci Rep ; 7(1): 9920, 2017 08 30.
Artigo em Inglês | MEDLINE | ID: mdl-28855571

RESUMO

Crystallographic defects such as dislocations can significantly alter material properties and functionality. However, imaging these imperfections during operation remains challenging due to the short length scales involved and the reactive environments of interest. Bragg coherent diffractive imaging (BCDI) has emerged as a powerful tool capable of identifying dislocations, twin domains, and other defects in 3D detail with nanometer spatial resolution within nanocrystals and grains in reactive environments. However, BCDI relies on phase retrieval algorithms that can fail to accurately reconstruct the defect network. Here, we use numerical simulations to explore different guided phase retrieval algorithms for imaging defective crystals using BCDI. We explore different defect types, defect densities, Bragg peaks, and guided algorithm fitness metrics as a function of signal-to-noise ratio. Based on these results, we offer a general prescription for phasing of defective crystals with no a priori knowledge.

5.
Ticks Tick Borne Dis ; 8(4): 540-546, 2017 06.
Artigo em Inglês | MEDLINE | ID: mdl-28320640

RESUMO

This study reports the results of a comparative test of identification of ticks occurring in Western Europe and Northern Africa. A total of 14 laboratories were voluntarily enrolled in the test. Each participant received between 22 and 25 specimens of adult and nymphal ticks of 11 species: Dermacentor marginatus, D. reticulatus, Haemaphysalis punctata, Hyalomma lusitanicum, Hy. marginatum, Ixodes ricinus, I. hexagonus, Rhipicephalus annulatus, R. bursa, R. rossicus, and/or R. sanguineus s.l. Ticks were morphologically identified by three of the co-authors and the identification confirmed by a fourth co-author who used molecular methods based on several genes. Then ticks were randomly selected and blindly distributed among participants, together with a questionnaire. Only specimens collected while questing and, if possible, in the same survey, were circulated. Because of the random nature of the test, a participant could receive several specimens of the same species. Species in the different genera had variable misidentification rates (MR) of 7% (Dermacentor), 14% (Ixodes), 19% (Haemaphysalis), 36% (Hyalomma), and 54% (Rhipicephalus). Within genera, the MR was also variable ranging from 5.4% for I. ricinus or 7.4% for D. marginatus or D. reticulatus to 100% for R. rossicus. The test provided a total misidentification rate of 29.6% of the species of ticks. There are no significant differences in MR according to the sex of the tick. Participants were requested to perform a second round of identifications on the same set of ticks, using only purposely prepared keys (without illustrations), circulated to the enrolled participants, including 2 species of the genus Dermacentor, 8 of Haemaphysalis, 10 of Hyalomma, 23 of Ixodes, and 6 of Rhipicephalus. The average MR in the second round was 28%: 0% (Dermacentor), 33% (Haemaphysalis), 30% (Hyalomma) 18% (Ixodes), and 50% (Rhipicephalus). Species which are not reported in the countries of a participating laboratory had always highest MR, i.e. purely Mediterranean species had highest MR by laboratories in Central and Northern Europe. Participants expressed their concerns about a correct identification for almost 50% of the ticks of the genera Hyalomma and Rhipicephalus. The results revealed less than total confidence in identifying the most prominent species of ticks in the Western Palearctic, and underpin the need for reference libraries for specialists involved in this task. Results also showed that a combination of certain genes may adequately identify the target species of ticks.


Assuntos
Ixodidae/classificação , Pesquisadores , África do Norte , Animais , Europa (Continente) , Feminino , Ixodidae/crescimento & desenvolvimento , Masculino , Ninfa/classificação , Ninfa/crescimento & desenvolvimento
6.
Sci Rep ; 6: 36307, 2016 10 31.
Artigo em Inglês | MEDLINE | ID: mdl-27796347

RESUMO

The magnetisation dynamics of the vortex core and Landau pattern of magnetic thin-film elements has been studied using holography with extended reference autocorrelation by linear differential operator (HERALDO). Here we present the first time-resolved x-ray measurements using this technique and investigate the structure and dynamics of the domain walls after excitation with nanosecond pulsed magnetic fields. It is shown that the average magnetisation of the domain walls has a perpendicular component that can change dynamically depending on the parameters of the pulsed excitation. In particular, we demonstrate the formation of wave bullet-like excitations, which are generated in the domain walls and can propagate inside them during the cyclic motion of the vortex core. Based on numerical simulations we also show that, besides the core, there are four singularities formed at the corners of the pattern. The polarisation of these singularities has a direct relation to the vortex core, and can be switched dynamically by the wave bullets excited with a magnetic pulse of specific parameters. The subsequent dynamics of the Landau pattern is dependent on the particular configuration of the polarisations of the core and the singularities.

7.
Infect Genet Evol ; 28: 704-14, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25111609

RESUMO

Modern methods allow a geometric representation of forms, separating size and shape. In entomology, as well as in many other fields involving arthropod studies, shape variation has proved useful for species identification and population characterization. In medical entomology, it has been applied to very specific questions such as population structure, reinfestation of insecticide-treated areas and cryptic species recognition. For shape comparisons, great importance is given to the quality of landmarks in terms of comparability. Two conceptually and statistically separate approaches are: (i) landmark-based morphometrics, based on the relative position of a few anatomical "true" or "traditional" landmarks, and (ii) outline-based morphometrics, which captures the contour of forms through a sequence of close "pseudo-landmarks". Most of the studies on insects of medical, veterinary or economic importance make use of the landmark approach. The present survey makes a case for the outline method, here based on elliptic Fourier analysis. The collection of pseudo-landmarks may require the manual digitization of many points and, for this reason, might appear less attractive. It, however, has the ability to compare homologous organs or structures having no landmarks at all. This strength offers the possibility to study a wider range of anatomical structures and thus, a larger range of arthropods. We present a few examples highlighting its interest for separating close or cryptic species, or characterizing conspecific geographic populations, in a series of different vector organisms. In this simple application, i.e. the recognition of close or cryptic forms, the outline approach provided similar scores as those obtained by the landmark-based approach.


Assuntos
Artrópodes/anatomia & histologia , Artrópodes/classificação , Entomologia/métodos , Animais
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA