Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
1.
Otol Neurotol ; 45(4): e281-e288, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38437816

RESUMO

OBJECTIVE: To examine the association between preoperative comorbidities and cochlear implant speech outcomes. STUDY DESIGN: Retrospective cohort. SETTING: Tertiary referral center. PATIENTS: A total of 976 patients who underwent cochlear implantation (CI) between January 2015 and May 2022. Adult patients with follow-up, preoperative audiologic data, and a standardized anesthesia preoperative note were included. EXPOSURE: Adult Comorbidity Evaluation 27 (ACE-27) based on standardized anesthesia preoperative notes. MAIN OUTCOME MEASURES: Postoperative change in consonant-nucleus-consonant (CNC) score, AzBio Sentence score in quiet, and AzBio + 10 dB signal-to-noise ratio (SNR). Sentence score of the implanted ear at 3, 6, and 12 months. RESULTS: A total of 560 patients met inclusion criteria; 112 patients (20%) had no comorbidity, 204 patients (36.4%) had mild comorbidities, 161 patients (28.8%) had moderate comorbidities, and 83 patients (14.8%) had severe comorbidities. Mixed model analysis revealed all comorbidity groups achieved a clinically meaningful improvement in all speech outcome measures over time. This improvement was significantly different between comorbidity groups over time for AzBio Quiet ( p = 0.045) and AzBio + 10 dB SNR ( p = 0.0096). Patients with severe comorbidities had worse outcomes. From preop to 12 months, the estimated marginal mean difference values (95% confidence interval) between the no comorbidity group and the severe comorbidity group were 52.3 (45.7-58.9) and 32.5 (24.6-40.5), respectively, for AzBio Quiet; 39.5 (33.8-45.2) and 21.2 (13.6-28.7), respectively, for AzBio + 10 dB SNR; and 43.9 (38.7-49.0) and 31.1 (24.8-37.4), respectively, for CNC. CONCLUSIONS: Comorbidities as assessed by ACE-27 are associated with CI performance. Patients with more severe comorbidities have clinically meaningful improvement but have worse outcome compared to patients with no comorbidities.


Assuntos
Implante Coclear , Implantes Cocleares , Percepção da Fala , Adulto , Humanos , Estudos Retrospectivos , Comorbidade , Resultado do Tratamento
2.
Nat Commun ; 15(1): 478, 2024 Jan 12.
Artigo em Inglês | MEDLINE | ID: mdl-38216553

RESUMO

Vestibular schwannomas (VS) are benign tumors that lead to significant neurologic and otologic morbidity. How VS heterogeneity and the tumor microenvironment (TME) contribute to VS pathogenesis remains poorly understood. In this study, we perform scRNA-seq on 15 VS, with paired scATAC-seq (n = 6) and exome sequencing (n = 12). We identify diverse Schwann cell (SC), stromal, and immune populations in the VS TME and find that repair-like and MHC-II antigen-presenting SCs are associated with myeloid cell infiltrate, implicating a nerve injury-like process. Deconvolution analysis of RNA-expression data from 175 tumors reveals Injury-like tumors are associated with larger tumor size, and scATAC-seq identifies transcription factors associated with nerve repair SCs from Injury-like tumors. Ligand-receptor analysis and in vitro experiments suggest that Injury-like VS-SCs recruit myeloid cells via CSF1 signaling. Our study indicates that Injury-like SCs may cause tumor growth via myeloid cell recruitment and identifies molecular pathways that may be therapeutically targeted.


Assuntos
Neuroma Acústico , Humanos , Neuroma Acústico/genética , Neuroma Acústico/metabolismo , Neuroma Acústico/patologia , Ecossistema , Multiômica , Células de Schwann/metabolismo , Transdução de Sinais/fisiologia , Análise de Célula Única , Microambiente Tumoral
3.
Otolaryngol Head Neck Surg ; 170(4): 1124-1132, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38018567

RESUMO

OBJECTIVE: To evaluate the predictive value of intracochlear electrocochleography (ECochG) for identifying tip fold-over during cochlear implantation (CI) using the slim modiolar electrode (SME) array. STUDY DESIGN: Prospective cohort study. SETTING: Tertiary referral center. METHODS: From July 2022 to June 2023, 142 patients, including adults and children, underwent intracochlear ECochG monitoring during and after SME placement. Tone-bursts were presented from 250 Hz to 2 kHz at 108 to 114 dB HL. A fast Fourier transform (FFT) allowed for frequency-specific evaluation of ECochG response. ECochG patterns during insertion and postinsertion were evaluated using sensitivity and specificity analysis to predict tip fold-over. Intraoperative plain radiographs served as a reference standard. RESULTS: Fifteen tip fold-over cases occurred (10.6%) with significant ECochG response (>2 µV). Sixty-one cases without tip fold-over occurred (43.0%) with significant ECochG response. All tip fold-overs had both a nontonotopic postinsertion sweep and nonrobust active insertion pattern. No patients with robust insertion or tonotopic sweep patterns had tip fold-over. Sensitivity of detecting tip fold-over when having both nonrobust insertion and nontonotopic sweep patterns was 100% (95% confidence inteval [CI] 78.2%-100%), specificity was 68.9% (95% CI 55.7%-80.1%), and the overall accuracy was 72.0% (95% CI 60.5%-81.7%). CONCLUSION: Intracochlear ECochG monitoring during cochlear implantation with the SME can be a valuable tool for identifying properly positioned electrode arrays. In cases where ECochG patterns are nonrobust on insertion and nontonotopic for electrode sweeps, there may be a concern for tip fold-over, and intraoperative imaging is necessary to confirm proper insertion.


Assuntos
Implante Coclear , Implantes Cocleares , Adulto , Criança , Humanos , Audiometria de Resposta Evocada/métodos , Estudos Prospectivos , Cóclea/diagnóstico por imagem , Cóclea/cirurgia , Implante Coclear/métodos
4.
Otol Neurotol ; 44(10): 988-996, 2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-37733968

RESUMO

OBJECTIVE: To evaluate the impact of preoperative and perioperative factors on postlinguistic adult cochlear implant (CI) performance and design a multivariate prediction model. STUDY DESIGN: Prospective cohort study. SETTING: Tertiary referral center. PATIENTS AND INTERVENTIONS: Two hundred thirty-nine postlinguistic adult CI recipients. MAIN OUTCOME MEASURES: Speech-perception testing (consonant-nucleus-consonant [CNC], AzBio in noise +10-dB signal-to-noise ratio) at 3, 6, and 12 months postoperatively; electrocochleography-total response (ECochG-TR) at the round window before electrode insertion. RESULTS: ECochG-TR strongly correlated with CNC word score at 6 months ( r = 0.71, p < 0.0001). A multivariable linear regression model including age, duration of hearing loss, angular insertion depth, and ECochG-TR did not perform significantly better than ECochG-TR alone in explaining the variability in CNC. AzBio in noise at 6 months had moderate linear correlations with Montreal Cognitive Assessment (MoCA; r = 0.38, p < 0.0001) and ECochG-TR ( r = 0.42, p < 0.0001). ECochG-TR and MoCA and their interaction explained 45.1% of the variability in AzBio in noise scores. CONCLUSIONS: This study uses the most comprehensive data set to date to validate ECochG-TR as a measure of cochlear health as it relates to suitability for CI stimulation, and it further underlies the importance of the cochlear neural substrate as the main driver in speech perception performance. Performance in noise is more complex and requires both good residual cochlear function (ECochG-TR) and cognition (MoCA). Other demographic, audiologic, and surgical variables are poorly correlated with CI performance suggesting that these are poor surrogates for the integrity of the auditory substrate.


Assuntos
Implante Coclear , Implantes Cocleares , Percepção da Fala , Adulto , Humanos , Estudos Prospectivos , Cóclea/cirurgia , Percepção da Fala/fisiologia , Cognição
5.
Otolaryngol Head Neck Surg ; 169(2): 340-347, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-36814321

RESUMO

OBJECTIVE: Compare postoperative speech outcomes in hearing preservation (HP) cochlear implantation (CI) patients with a low-frequency pure-tone average (LFPTA) ≤ 60 dB using 2 electrode array designs. STUDY DESIGN: Retrospective cohort study. SETTING: Large academic cochlear implant referral center. METHODS: We reviewed adult HP CI cases using either the slim modiolar electrode (SME) (CI 532/CI 632) or th slim lateral wall electrode (SLWE) (CI 624). One-year speech outcomes and HP status were the primary outcomes. RESULTS: A total of 132 implanted ears were analyzed (mean age 73.1 years, standard deviation [SD] 12.6), with 72% (N = 95) with CI 532/632 and 28% (N = 37) with CI 624. The mean preoperative LFPTA was 44.8 dB, SD 11.8. One-year functional HP was 27.2% (mean LFPTA shift 46.1 dB, SD 22.1) and was as follows: SME 23.9% and SLWE 36.4%, p = .168. The mean age at implantation was significantly younger only in SLWE patients with preserved hearing (66.9 vs 80.3 years, p = .008). At 6 months, speech measures were significantly better in all outcomes in HP patients with an SLWE than nonpreserved SLWE patients; this effect abated at 1 year as performance among nonpreserved SLWE patients became equivalent to the remaining cohort. Speech outcomes in SME patients were similar regardless of HP status. Age at implantation and datalogging was correlated with speech outcomes. CONCLUSION: In this cohort of HP patients, a 1-year functional HP rate of 23.9% (SME) and 36.4% (SLWE) was observed (p = 0.168). This was initially 57.1% (SME) and 70.3% (SLWE) at activation, p = .172. Datalogging and age at implantation were correlated with postoperative speech outcomes.


Assuntos
Implante Coclear , Implantes Cocleares , Percepção da Fala , Adulto , Idoso , Idoso de 80 Anos ou mais , Humanos , Audiometria de Tons Puros , Cóclea/cirurgia , Audição/fisiologia , Estudos Retrospectivos , Fala , Percepção da Fala/fisiologia , Resultado do Tratamento , Pessoa de Meia-Idade
6.
Otol Neurotol ; 44(3): e146-e154, 2023 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-36728163

RESUMO

OBJECTIVE: This study aimed 1) to measure the effect of cochlear implantation on health-related quality of life (HR-QOL) using the Cochlear Implant Quality of Life (CIQOL) questionnaire and 2) to determine audiologic, demographic, and non-CI/hearing-related QOL factors influencing the CIQOL. STUDY DESIGN: Prospective observational study. SETTING: Tertiary referral center. PATIENTS AND INTERVENTIONS: Thirty-seven adult patients with sensorineural hearing loss undergoing cochlear implantation. MAIN OUTCOME MEASURES: CIQOL-global score preimplantation and 6 months postimplantation. Physical function score as measured by the short-form survey, audiologic, and demographic variables. RESULTS: CIQOL showed significant improvement from preimplantation to 6 months postactivation with a mean difference of 14.9 points (95% confidence interval, 11.3 to 18.5, p < 0.0001). Improvement in CIQOL (ΔCIQOL) correlated linearly with age ( r = -0.49, p = 0.001) and improvement in speech perception testing ( r = 0.63, p < 0.0001). Multivariate modeling using age and change in consonant-vowel nucleus-consonant (CNC) score explained 46% of the variability measured by the ΔCIQOL-global score. CONCLUSIONS: Nearly all CI recipients achieve significant gains for all domains as measured by the CIQOL. However, younger patients and those with a greater improvement in speech perception performance (CNC) are more likely to achieve a greater CIQOL benefit. Results here suggest the importance of considering preoperative CIQOL and speech perception measures when evaluating predictors of HR-QOL.


Assuntos
Implante Coclear , Implantes Cocleares , Perda Auditiva Neurossensorial , Percepção da Fala , Adulto , Humanos , Implante Coclear/métodos , Qualidade de Vida , Perda Auditiva Neurossensorial/cirurgia , Audição , Percepção da Fala/fisiologia , Resultado do Tratamento
7.
Laryngoscope ; 133(9): 2379-2387, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-36300628

RESUMO

OBJECTIVES: To examine long-term speech and cognition outcomes in older adult cochlear implant (CI) recipients. First, by evaluating if CI performance was maintained over an extended follow-up period regardless of preoperative cognitive status. Secondly, by evaluating if there was a difference in the rate of cognitive decline between preoperative mild and normal cognition following CI over an extended period of time. STUDY DESIGN AND SETTING: Retrospective cohort study. METHODS: CI recipients ≥65 years of age implanted between 2009 and 2014 with 4+ years follow up. Pre- and postoperative audiometric and speech outcome assessments were collected. Cognitive status was measured using the mini mental status examination (MMSE) at numerous time points. RESULTS: Fifty-three patients met inclusion. Patients were divided into two groups based on preoperative MMSE with scores considered normal (28-30) and those with mildly impaired cognition (MIC, scores 25-27). Audiometric and speech performance improved significantly at one-year post implantation and this was maintained without significant change at 4+ years, regardless of cognitive status. Mixed modeling analysis controlling for age demonstrated no significant difference in the rate of cognitive decline at 4+ years post implantation between the normal cognition cohort (1.74; 95%CI 0.89-2.6) and MIC (2.9; 95%1.91-3.88). CONCLUSION: Speech performance was significantly improved and sustained after CI in both normal cognition and MIC patients. The rate of cognitive decline in older adult CI patients appears to be similar regardless of preoperative cognitive status. Although results demonstrate rates of cognitive decline following CI did not differ between cognition groups over 4+ years, future studies will need to further investigate this over extended time periods with a more comprehensive cognitive testing battery. LEVEL OF EVIDENCE: 4 Laryngoscope, 133:2379-2387, 2023.


Assuntos
Implante Coclear , Implantes Cocleares , Disfunção Cognitiva , Percepção da Fala , Humanos , Idoso , Implantes Cocleares/psicologia , Estudos Retrospectivos , Implante Coclear/métodos , Cognição , Resultado do Tratamento
8.
Otol Neurotol ; 43(10): e1180-e1186, 2022 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-36214506

RESUMO

OBJECTIVE: Report the incidence of and treatment patterns for facial nerve palsy after skull base fracture. STUDY DESIGN: Retrospective cohort study. SETTING: IBM MarketScan Commercial Database (2006-2019). PATIENTS: Human subjects with skull base fracture, per International Classification of Diseases-9th and 10th Revisions-Clinical Modification diagnosis codes. MAIN OUTCOME MEASURES: The primary outcomes were the incidence and median time to facial nerve palsy diagnosis within 30 days of skull base fracture. Secondary outcomes were treatments (corticosteroids, antivirals, facial nerve decompression, botulinum toxin, and facial reanimation), demographics, and rates of hearing loss, vertigo, tympanic membrane rupture, cerebrospinal fluid leak, comorbidities, and loss of consciousness. RESULTS: The 30-day incidence of facial nerve palsy after skull base trauma was 1.0% (738 of 72,273 patients). The median (95% confidence interval [CI]) time to diagnosis was 6 (6-7) days, and only 22.9% were diagnosed within 1 day. There were significantly higher rates (risk difference, 95% CI) of hearing loss (26%, 22-29%), tympanic membrane rupture (6.3%, 4.5-8.1%), cerebrospinal fluid leak (6.4%, 4.5-8.3%), comorbidity (14%, 10.4-17.6%), and loss of consciousness (24.3%, 20.7-27.9%). Loss of consciousness was associated with longer median (95% CI) time to facial nerve palsy diagnosis: 10 (9-10) days. Corticosteroids were the most common treatment but only reported for less than one-third of patients. Only eight patients underwent facial nerve decompression. CONCLUSIONS: Facial nerve palsy after skull base fracture is associated with higher comorbidity, and the diagnosis is often delayed. Few patients were treated with surgery, and there are inconsistencies in the types and timing of treatments.


Assuntos
Traumatismos Craniocerebrais , Paralisia Facial , Perda Auditiva , Fraturas Cranianas , Perfuração da Membrana Timpânica , Humanos , Paralisia Facial/epidemiologia , Paralisia Facial/etiologia , Paralisia Facial/terapia , Incidência , Estudos Retrospectivos , Perfuração da Membrana Timpânica/complicações , Traumatismos Craniocerebrais/complicações , Base do Crânio/cirurgia , Vazamento de Líquido Cefalorraquidiano/epidemiologia , Perda Auditiva/epidemiologia , Perda Auditiva/etiologia , Perda Auditiva/terapia , Inconsciência/complicações , Fraturas Cranianas/complicações
9.
Otol Neurotol ; 43(9): e1000-e1007, 2022 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-36047695

RESUMO

OBJECTIVE: To assess the clinical application of five recently published cochlear implant (CI) candidacy evaluation (CICE) referral screening tools through external validation. STUDY DESIGN: Retrospective cohort study. SETTING: Tertiary otology/neurotology practice. PATIENTS: Adults who underwent CICE between December 2020 and September 2021. INTERVENTIONS: CICE referral screening tools versus CI candidacy criteria. MAIN OUTCOME MEASURES: CICE screening tool performance, based on the ability to identify patients who met the CI candidacy criteria, was evaluated. CI candidacy criteria were defined as best-aided AzBio sentences at +10 signal-to-noise ratio and either 60% or less accuracy to reflect traditional criteria used in clinical settings or 40% or less accuracy (only patients 65 years or older) to reflect Medicare-eligible criteria. RESULTS: Screening criteria of proposed CICE referral tools vary widely across pure-tone average and word recognition scores. When screened by traditional criteria, the sensitivities and specificities of these referral tools varied from 40 to 77% and from 22 to 86%, respectively. When screened by Medicare-eligible criteria, sensitivities and specificities varied from 41 to 81% and from 24 to 91%, respectively. The screening tool proposed by Zwolan et al. ( Otol Neurotol 2020;41(7):895-900) demonstrated the best overall performance for traditional (Youden's J , 0.37; sensitivity, 62%; specificity, 75%) and Medicare-eligible patients (Youden's J , 0.44; sensitivity, 66%; specificity, 78%). All screening tools performed worse on the validation cohort compared with their respective development cohorts. CONCLUSIONS: Current tools for determining CICE referral have diverse screening criteria. These combinations of pure-tone average and word recognition score are modestly successful at identifying CI candidates.


Assuntos
Implante Coclear , Implantes Cocleares , Percepção da Fala , Adulto , Idoso , Humanos , Medicare , Seleção de Pacientes , Estudos Retrospectivos , Estados Unidos
10.
Front Neurosci ; 16: 915302, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35937872

RESUMO

Objectives: Electrocochleography (ECochG) recordings during cochlear implantation have shown promise in estimating the impact on residual hearing. The purpose of the study was (1) to determine whether a 250-Hz stimulus is superior to 500-Hz in detecting residual hearing decrement and if so; (2) to evaluate whether crossing the 500-Hz tonotopic, characteristic frequency (CF) place partly explains the problems experienced using 500-Hz. Design: Multifrequency ECochG comprising an alternating, interleaved acoustic complex of 250- and 500-Hz stimuli was used to elicit cochlear microphonics (CMs) during insertion. The largest ECochG drops (≥30% reduction in CM) were identified. After insertion, ECochG responses were measured using the individual electrodes along the array for both 250- and 500-Hz stimuli. Univariate regression was used to predict whether 250- or 500-Hz CM drops explained low-frequency pure tone average (LFPTA; 125-, 250-, and 500-Hz) shift at 1-month post-activation. Postoperative CT scans were performed to evaluate cochlear size and angular insertion depth. Results: For perimodiolar insertions (N = 34), there was a stronger linear correlation between the largest ECochG drop using 250-Hz stimulus and LFPTA shift (r = 0.58), compared to 500-Hz (r = 0.31). The 250- and 500-Hz CM insertion tracings showed an amplitude peak at two different locations, with the 500-Hz peak occurring earlier in most cases than the 250-Hz peak, consistent with tonotopicity. When using the entire array for recordings after insertion, a maximum 500-Hz response was observed 2-6 electrodes basal to the most-apical electrode in 20 cases (58.9%). For insertions where the apical insertion angle is >350 degrees and the cochlear diameter is <9.5 mm, the maximum 500-Hz ECochG response may occur at the non-apical most electrode. For lateral wall insertions (N = 14), the maximum 250- and 500-Hz CM response occurred at the most-apical electrode in all but one case. Conclusion: Using 250-Hz stimulus for ECochG feedback during implantation is more predictive of hearing preservation than 500-Hz. This is due to the electrode passing the 500-Hz CF during insertion which may be misidentified as intracochlear trauma; this is particularly important in subjects with smaller cochlear diameters and deeper insertions. Multifrequency ECochG can be used to differentiate between trauma and advancement of the apical electrode beyond the CF.

11.
Otol Neurotol ; 43(8): 915-923, 2022 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-35861658

RESUMO

OBJECTIVE: 1) To determine the relationship of electrocochleography (ECochG) responses measured on the promontory with responses measured at the round window (RW) and various intracochlear sites. 2) To evaluate if promontory ECochG responses correlate with postoperative speech-perception performance using the cochlear implant (CI). STUDY DESIGN: Prospective cohort study. SETTING: Tertiary referral center. PATIENTS AND INTERVENTIONS: Ninety-six adult CI recipients with no cochlear malformations or previous otologic surgery. MAIN OUTCOME MEASURES: Acoustically evoked ECochG responses were measured intraoperatively at both extracochlear and intracochlear locations. ECochG total response (ECochG-TR), a measure of residual cochlear function, was calculated by summing the fast Fourier transformation amplitudes in response to 250-Hz to 2-kHz acoustic stimuli. Speech-perception performance was measured at 3 months. RESULTS: There were strong linear correlations for promontory ECochG-TR with the ECochG-TRs measured at the RW ( r = 0.95), just inside scala tympani ( r = 0.91), and after full insertion ( r = 0.83). For an individual subject, the morphology of the ECochG response was similar in character across all positions; however, the response amplitude increased from promontory to RW (~1.6-fold) to just inside scala tympani (~2.6-fold), with the largest response at full insertion (~13.1-fold). Promontory ECochG-TR independently explained 51.8% of the variability ( r2 ) in consonant-nucleus-consonant at 3 months. CONCLUSIONS: Promontory ECochG recordings are strongly correlated with responses previously recorded at extracochlear and intracochlear sites and explain a substantial portion of the variability in CI performance. These findings are a critical step in supporting translation of transtympanic ECochG into the clinic preoperatively to help predict postoperative CI performance.


Assuntos
Implante Coclear , Implantes Cocleares , Percepção da Fala , Adulto , Audiometria de Resposta Evocada , Humanos , Estudos Prospectivos , Fala
12.
Sci Rep ; 12(1): 3083, 2022 02 23.
Artigo em Inglês | MEDLINE | ID: mdl-35197556

RESUMO

Although significant progress has been made in understanding outcomes following cochlear implantation, predicting performance remains a challenge. Duration of hearing loss, age at implantation, and electrode positioning within the cochlea together explain ~ 25% of the variability in speech-perception scores in quiet using the cochlear implant (CI). Electrocochleography (ECochG) responses, prior to implantation, account for 47% of the variance in the same speech-perception measures. No study to date has explored CI performance in noise, a more realistic measure of natural listening. This study aimed to (1) validate ECochG total response (ECochG-TR) as a predictor of performance in quiet and (2) evaluate whether ECochG-TR explained variability in noise performance. Thirty-five adult CI recipients were enrolled with outcomes assessed at 3-months post-implantation. The results confirm previous studies showing a strong correlation of ECochG-TR with speech-perception in quiet (r = 0.77). ECochG-TR independently explained 34% of the variability in noise performance. Multivariate modeling using ECochG-TR and Montreal Cognitive Assessment (MoCA) scores explained 60% of the variability in speech-perception in noise. Thus, ECochG-TR, a measure of the cochlear substrate prior to implantation, is necessary but not sufficient for explaining performance in noise. Rather, a cognitive measure is also needed to improve prediction of noise performance.


Assuntos
Audiometria de Resposta Evocada , Implante Coclear , Implantes Cocleares , Cognição/fisiologia , Perda Auditiva/psicologia , Perda Auditiva/cirurgia , Ruído , Percepção da Fala/fisiologia , Adulto , Fatores Etários , Audiometria , Feminino , Perda Auditiva/diagnóstico , Perda Auditiva/fisiopatologia , Humanos , Masculino , Resultado do Tratamento
13.
Otol Neurotol ; 43(4): 443-451, 2022 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-35170555

RESUMO

OBJECTIVE: Describe early hearing preservation (HP) cochlear implantation (CI) outcomes using a new slim lateral wall electrode (SLWE). STUDY DESIGN: Prospective cohort study. SETTING: Tertiary referral center. PATIENTS: Adult CI candidates with preoperative low-frequency pure-tone average (LFPTA; 125, 250, 500 Hz) ≤60 dB HL. INTERVENTION: CI with and without intracochlear real-time electrocochleography (RT-ECochG). MAIN OUTCOME MEASURE: HP (LFPTA ≤80 dB HL), LFPTA shift, speech-perception performance measures, postoperative CT reconstruction. RESULTS: Forty-two subjects were implanted with the SLWE. Thirty patients underwent full insertion without RT-ECochG feedback, and HP was maintained at 3-months postactivation for 7 (23.3%) patients with mean LFPTA shift of 57.5 ±â€Š25.6 dB HL. RT-ECochG feedback was utilized on 12 patients, of whom 6 patients had full insertions and 6 patients had anywhere from 1 to 3 electrodes left outside of the cochlea based on RT-ECochG feedback. At 3 months postoperatively, HP was achieved on 10 (83.3%) patients and mean LFPTA shift was 18.9 c 11.7 dB HL. Mean difference between LFPTA threshold shift at 3-months postactivation with and without RT-ECochG was 38.6 dB HL (95% CI, 25.6-51.67). There was an improvement in delta CNC from preoperative to 3-months postactivation when using RT-ECochG, with mean difference 20.7% (95% CI, 3.3-38.1). CONCLUSIONS: Use of RT-ECochG monitoring during SLWE placement results in fewer full electrode insertions and significantly better HP rates and speech-perception outcomes when compared with unmonitored insertions. Further investigation is needed to evaluate long-term audiologic outcomes to better understand the relationships among ECochG, cochlear trauma, functional outcomes, and HP.


Assuntos
Implante Coclear , Implantes Cocleares , Adulto , Audiometria de Resposta Evocada/métodos , Audiometria de Tons Puros , Limiar Auditivo/fisiologia , Implante Coclear/métodos , Audição/fisiologia , Humanos , Estudos Prospectivos , Resultado do Tratamento
14.
Otol Neurotol ; 43(1): 72-79, 2022 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-34889840

RESUMO

OBJECTIVE: To evaluate the impact of different open set sentence recognition tests in quiet, +10 dB signal to noise ratio (SNR), and +5 dB SNR in adult cochlear implant (CI) recipients above and below 65 years of age. STUDY DESIGN AND SETTING: Multi-institution, prospective, non-randomized, single-subject repeated measures design. PATIENTS: Ninety six adults more than or equal to 18 years old with postlingual bilateral sensorineural hearing loss. INTERVENTIONS: Participants received a CI532 in one ear. Speech perception measures were evaluated before and 6-months after activation. MAIN OUTCOME MEASURES: Subjects completed consonant-nucleus-constant (CNC) words in quiet and AzBio sentences in noise using +10 and +5 dB SNR, and Montreal Cognitive Assessment (MOCA). RESULTS: Ninety six adult patients were enrolled (n = 70 older [≥65 yr], n = 26 younger [<65 yr]). There was no difference in CNC scores (CI alone 58.4% versus 67.5%, p = 0.0857; best aided 66.7% versus 76.1%, p = 0.3357). Older adults performed worse on AzBio +10 dB SNR compared with younger patients (CI alone 37.4% versus 56.9%, p = 0.0006; best aided 51.4% versus 68.2%; p = 0.01), and in AzBio +5 dB SNR (CI alone 7.7% versus 11.2%, p = 0.0002; best aided 15.3% versus 22.3%, p = 0.0005). The magnitude of change in AzBio +10 dB SNR was significantly less in older adults in CI alone (15.3% versus 22.3%; p = 0.0493) but not best aided (21.5% versus 31.3%; p = 0.105). The magnitude of change was drastically worse in AzBio +5 dB SNR for older adults (CI alone 6.7% versus 22.1%, p = 0.0014; best aided 9.5% versus 21.5%; p = 0.0142). There was no significant difference in MOCA between the two age groups. CONCLUSIONS: While both older and younger patients have similar outcomes with respect to CNC word scores in quiet, the addition of noise disproportionally impacts older patients. Caution should be exercised testing the elderly in noise; testing in noise may disproportionally impact performance expectations and should be more carefully considered when used for candidacy criteria and counseling. Future studies need to further investigate the disproportionate effect of noise on candidacy testing and its impact on how elderly patients are qualified.


Assuntos
Implante Coclear , Implantes Cocleares , Percepção da Fala , Idoso , Implante Coclear/métodos , Humanos , Estudos Prospectivos , Percepção da Fala/fisiologia , Resultado do Tratamento
15.
J Am Acad Audiol ; 32(7): 395-404, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-34847581

RESUMO

BACKGROUND: Best practice guidelines for verifying fittings of bone-anchored hearing devices (BAHD) recommend using aided sound-field thresholds (ASFT), but express caution regarding the variables impacting obtaining valid and reliable ASFTs.1 Recently, a skull simulator was introduced to facilitate programming BAHD devices in force level (FL) to desired sensation level-bone conduction devices (skull simulator/DSL-BCD)2 3 targets in a hearing aid analyzer. Currently, no evidence is available reporting if differences in measured FL using the manufacturer first-fit (FF) and word recognition in quiet, sentence reception threshold in noise, and subjective outcomes are present for a BAHD programmed using ASFT versus programmed using skull simulator/DSL-BCD targets. PURPOSE: The aim of this study was to examine if significant differences were present in FL using the FF and word recognition in quiet at 50 and 65 decibel of sound pressure level (dB SPL), sentence reception threshold in noise and subjective outcomes using the abbreviated profile of hearing aid benefit (APHAB), and speech, spatial, and qualities of hearing (SSQ) between a BAHD fit using ASFT or skull simulator/DSL-BCD targets. RESEARCH DESIGN: A double-blind randomized crossover design with 15 adults having unilateral sensorineural hearing loss. All participants were successful users of the Cochlear America Baha 5. DATA COLLECTION AND ANALYSIS: Baha Power 5 devices were fit using FF, ASFT, and skull simulator/DSL-BCD targets. Order of the three fitting strategies was randomly assigned and counter-balanced. RESULTS: No significant differences were found for a BAHD device programmed using ASFT versus skull simulator/DSL-BCD targets for consonant-nucleus-consonant words in quiet at 50 or 65 dB SPL, sentence reception threshold in noise, the APHAB or SSQ. There were, however, significant differences, at primarily 500 to 2,000 Hz in measured FLs between the FF, ASFT, and skull simulator/DSL-BCD targets at 50 and 65 dB SPL. CONCLUSIONS: There were no significant differences in subject performance with two speech measures and subjective responses to two questionnaires for BAHD fittings using ASFT versus using skull simulator/DSL-BCD targets. Differences in FL between the three fitting strategies were present primarily at 500 to 2,000 Hz. Limitations of the study are highlighted along with situations where the skull simulator can play a significantly beneficial role when fitting BAHD devices.


Assuntos
Audição , Crânio , Estudos Cross-Over , Método Duplo-Cego , Humanos , Som
16.
JAMA Otolaryngol Head Neck Surg ; 147(11): 991-998, 2021 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-34617972

RESUMO

Importance: Vestibular schwannomas have long been treated as a homogeneous entity. Clinical symptoms at presentation may help elucidate the underlaying pathophysiologic characteristics of tumor subtypes. Describing the heterogeneity of these benign tumors may assist in predicting clinical outcomes associated with their treatment. Objective: To create a tumor staging system that incorporates symptoms at presentation and tumor size to predict severe surgical complications. Design, Setting, and Participants: A retrospective cohort of patients at a single-center tertiary referral center from January 1, 1998, to October 13, 2020, was studied. Patients diagnosed with sporadic vestibular schwannoma surgically treated at Washington University in St Louis, Missouri, were included. Main Outcomes and Measures: Severe surgical complications within 30 days of surgery as determined by the Clavien-Dindo classification system. Patients experiencing a complication of grade 3 or above were determined to have a severe complication. Results: Of 185 patients evaluated, 40 (22%) had severe postoperative complications. Twenty of the 40 patients (50%) were women; mean (SD) age was 46 (13) years. Patients with severe complications were more likely to have large tumors (>2.5 cm in largest diameter), vestibular symptoms, and recent hearing loss at presentation. Using conjunctive consolidation, a 4-stage clinical severity staging system that incorporates clinical symptoms and tumor size at presentation was created to predict severe complications. The clinical severity staging system demonstrated an improvement in the ability to discriminate severe complications (C index, 0.754; 95% CI, 0.67-0.84) from a model of tumor size alone (C index, 0.706; 95% CI 0.62-0.79). Conclusions and Relevance: This cohort study found that, among patients with vestibular schwannoma, symptoms present at initial evaluation, in addition to tumor size, served as predictors of severe postoperative complications. A new clinical severity staging system incorporating symptoms at presentation can be helpful for clinicians to identify patients at high risk for severe postoperative complications.


Assuntos
Neuroma Acústico/diagnóstico , Neuroma Acústico/cirurgia , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/etiologia , Índice de Gravidade de Doença , Adulto , Idoso , Feminino , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Neuroma Acústico/patologia , Estudos Retrospectivos , Medição de Risco , Carga Tumoral
17.
Otol Neurotol ; 42(10): e1486-e1493, 2021 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-34510116

RESUMO

OBJECTIVE: Describe audiologic outcomes in hearing preservation (HP) cochlear implant candidates using a slim modiolar electrode (SME). STUDY DESIGN: Retrospective. SETTING: Tertiary referral center. PATIENTS: Two hundred three adult cochlear implant patients with preoperative low-frequency pure-tone average (LFPTA) ≤ 80 dB HL that received the SME. INTERVENTION: Implantation with a SME electrode. MAIN OUTCOME MEASURES: Primary outcome was postoperative HP, defined as LFPTA ≤80 dB HL. HP status was analyzed at "early" (activation or 3 mo) and "long-term" (6 or 12 mo) time frames using the patient's worst audiogram. Speech perception tests were compared between HP and non-HP cohorts. RESULTS: Of the 203 HP candidates, the tip fold-over rate was 7.4%. The mean shifts in LFPTA at the "early" and "long-term" time points were 25.9 ±â€Š16.2 dB HL and 29.6 ±â€Š16.9 dB HL, respectively. Of 117 patients with preoperative LFPTA ≤60 dB HL, the early and long-term mean LFPTA shifts were 19.5 ±â€Š12.3 dB HL and 32.6 ±â€Š17.2 dB HL, respectively; early and long-term HP rates were 61.1% and 50.8%, respectively. For patients with preoperative LFPTA ≤80 dB HL, early and long-term HP rates were 45.5% and 43.7%, respectively. No significant difference was observed in postoperative speech perception performance (CNC, AzBio, HINT) at 3, 6, or 12 months between HP versus non-HP groups. CONCLUSIONS: HP is feasible using the SME. While electroacoustic stimulation was not studied in this cohort, HP provided no clear advantage in speech perception abilities in this group of patients. The current reporting standard of what constitutes HP candidacy (preoperative LFPTA ≤80 dB HL) should be reconsidered.


Assuntos
Implante Coclear , Implantes Cocleares , Percepção da Fala , Adulto , Audiometria de Tons Puros , Limiar Auditivo/fisiologia , Audição/fisiologia , Humanos , Estudos Retrospectivos , Percepção da Fala/fisiologia , Resultado do Tratamento
18.
J Am Acad Audiol ; 32(3): 157-163, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-34062602

RESUMO

BACKGROUND: Hearing aid fitting guidelines recommend real ear measures (REM) to verify hearing aid performance. Unfortunately, approximately 70 to 80% of clinicians do not use REM, but instead download manufacturer first-fit. Studies report differences in performance between first-fit and programmed-fit with greatest differences in the higher frequencies. Recently, hearing aid and real ear analyzer (REA) manufacturers allow REA communication with hearing aid software feature to automatically program hearing aids to target. Little research is available reporting the accuracy of this feature. PURPOSE: The aim of the study is to examine whether differences exist at 50, 65, and 80 dB SPL between two ReSound first-fit formulae (Audiogram+ and NAL-NL2) using ReSound AutoREM and Aurical NAL-NL2 RESEARCH DESIGN: The study design is of repeated measure type. STUDY SAMPLE: The study sample includes 48 ears. DATA COLLECTION AND ANALYSIS: For the two fitting formulae, AutoREM real ear insertion gain (REIG) was measured at 50, 65, and 80 dB SPL and compared with measures from Aurical NAL-NL2. RESULTS: Mean AutoREM REIG for ReSound NAL-NL2 was 3 to 8 dB below Aurical NAL-NL2 for 50 dB SPL, within 1 to 3 dB for 65 dB SPL and 1 to 5 dB above for 80 dB SPL. Mean AutoREM REIG for Audiogram + was 1 to 12 dB below Aurical NAL-NL2 for 50 dB SPL, within 2 to 5 dB for 65 dB SPL and 1 to 7 dB above NAL-NL2 for 80 dB SPL. CONCLUSION: Relative to the Aurical NAL-NL2, AutoREM REIG50 for Audiogram + and ReSound NAL-NL2 was lower. Relative to the Aurical NAL-NL2, AutoREM REIG65 for Audiogram + was higher at 1,000 Hz and lower at 4,000 to 6,000 Hz and for ReSound NAL-NL2 it was lower at 500 Hz and 4,000 Hz and higher at 3,000 Hz. Relative to the Aurical NAL-NL2, AutoREM REIG80 for Audiogram + was higher at 500 to 3,000 Hz and 6,000 Hz and ReSound NAL-NL2 was higher at 500 to 6,000 Hz. Because of wide intersubject variability clinicians should continue to use REM as a "check and balance" when using AutoREM.


Assuntos
Auxiliares de Audição , Perda Auditiva Neurossensorial , Percepção da Fala , Humanos , Percepção Sonora , Proibitinas , Ajuste de Prótese , Software
19.
Otol Neurotol ; 42(1): 82-91, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33301285

RESUMO

OBJECTIVE: To evaluate the prevalence, surgical management, and audiologic impact of pulsatile tinnitus caused by sigmoid sinus dehiscence. STUDY DESIGN AND SETTING: Retrospective chart review at a tertiary care hospital. PATIENTS: Adults with unilateral pulsatile tinnitus attributable to sigmoid sinus dehiscence who underwent resurfacing between January 2010 and January 2020. INTERVENTIONS: Transmastoid sigmoid resurfacing. MAIN OUTCOME MEASURES: Resolution of pulsatile tinnitus; audiologic outcomes; complications; tinnitus etiologies. RESULTS: Nineteen patients (89.4% women) had surgery for suspected sigmoid sinus dehiscence. The mean dehiscence size was 6.1 mm (range, 1-10.7 mm). Eight patients had concurrent sigmoid sinus diverticulum and one patient also had jugular bulb dehiscence. Only two patients (10.5%) had the defect identified by radiology. Low-frequency pure-tone average, measured at frequencies of 250 and 500 Hz, showed a significant median improvement of 8.8 dB following resurfacing (18.8 dB versus 10.0 dB, p = 0.02). The majority of patients had complete resolution of pulsatile tinnitus (16/19, 84.2%). Of those without complete resolution, two patients had partial response and one patient had no improvement. There were no significant complications. Of 41 consecutively tracked patients with a pulsatile tinnitus chief complaint, sigmoid pathology represented 32% of cases. CONCLUSIONS: Sigmoid sinus dehiscence represents a common vascular cause of pulsatile tinnitus that, if properly assessed, may be amenable to surgical intervention. Sigmoid sinus resurfacing is safe, does not require decompression, and may improve low-frequency hearing. Radiographic findings of dehiscence are often overlooked without a high index of clinical suspicion. Its relationship with transverse sinus pathology and idiopathic intracranial hypertension remain unclear.


Assuntos
Divertículo , Zumbido , Adulto , Cavidades Cranianas/diagnóstico por imagem , Cavidades Cranianas/cirurgia , Feminino , Humanos , Masculino , Prevalência , Estudos Retrospectivos , Zumbido/diagnóstico por imagem , Zumbido/epidemiologia , Zumbido/etiologia
20.
Am J Otolaryngol ; 42(1): 102794, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33130529

RESUMO

PURPOSE: Controversy exists regarding the ideal approach for repair of lateral skull base defects. Our goal is to report the outcomes following middle cranial fossa (MCF) mini-craniotomy combined with mastoidectomy for patients with superior semicircular canal dehiscence (SSCD), spontaneous cerebrospinal fluid (CSF) leak, and cholesteatoma. MATERIALS AND METHODS: A retrospective database from chart review was formed consisting of 97 patients who met surgical criteria: SSCD, spontaneous CSF leak, and cholesteatoma. Mini-craniotomy MCF approach (<4 × 2 cm in size) combined with mastoidectomy was performed. All patients were admitted directly to the ICU postoperatively. Multiple factors were assessed, including need for revision surgery, duration of surgery, length of post-operative stay, and hospital readmission. RESULTS: Average surgery time was 110 min with no intraoperative complications. The average length of hospitalization was 2 days with an average ICU stay of 1 day. There were no neurologic complications; however, there were 3 inpatient complications (3%) which included 1 patient (1%) that had wound breakdown and 2 patients (2%) that had severe post-operative vertigo. A total of 8 patients (8%) required revision surgery and these were primarily for SSCD. The 30-day readmission rate was 3%. CONCLUSION: In the current series, all patients that underwent mini-craniotomy MCF surgery combined with mastoidectomy had minimal complications, short surgical time, limited hospital stay, low revision surgery rate and few hospital readmissions. This combined approach offers superior visualization of lateral skull base defects without the morbidity and risk typically associated with traditional, extensive MCF surgery.


Assuntos
Vazamento de Líquido Cefalorraquidiano/cirurgia , Colesteatoma/cirurgia , Fossa Craniana Média/cirurgia , Craniotomia/métodos , Mastoidectomia/métodos , Deiscência do Canal Semicircular/cirurgia , Canais Semicirculares/cirurgia , Base do Crânio/cirurgia , Adolescente , Adulto , Idoso , Feminino , Humanos , Tempo de Internação/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Readmissão do Paciente/estatística & dados numéricos , Reoperação/estatística & dados numéricos , Estudos Retrospectivos , Resultado do Tratamento , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA