Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Children (Basel) ; 10(5)2023 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-37238379

RESUMO

BACKGROUND: We were able to demonstrate the feasibility of a new robotic system (Versius, CMR Surgical, Cambridge, UK) for procedures in small inanimate cavities. The aim of this consecutive study was to test the Versius® system for its feasibility, performance, and safety of robotic abdominal and thoracic surgery in piglets simulating infants with a body weight lower than 10 kg. METHODS: A total of 24 procedures (from explorative laparoscopy to thoracoscopic esophageal repair) were performed in 4 piglets with a mean age of 12 days and a mean body weight of 6.4 (7-7.5) kg. Additional urological procedures were performed after euthanasia of the piglet. The Versius® robotic system was used with 5 mm wristed instruments and a 10 mm 3D 0° or 30° camera. The setup consisted of the master console and three to four separate arms. The performance of the procedure, the size, position, and the distance between the ports, the external and internal collisions, and complications of the procedures were recorded and analyzed. RESULTS: We were able to perform all surgical procedures as planned. We encountered neither surgical nor robot-associated complications in the live model. Whereas all abdominal procedures could be performed successfully under general anesthesia, one piglet was euthanized early before the thoracic interventions, likely due to pulmonary inflammatory response. Technical limitations were based on the size of the camera (10 mm) being too large and the minimal insertion depth of the instruments for calibration of the fulcrum point. CONCLUSIONS: Robotic surgery on newborns and infants appears technically feasible with the Versius® system. Software adjustments for fulcrum point calibration need to be implemented by the manufacturer as a result of our study. To further evaluate the Versius® system, prospective trials are needed, comparing it to open and laparoscopic surgery as well as to other robotic systems.

2.
Children (Basel) ; 9(9)2022 Sep 13.
Artigo em Inglês | MEDLINE | ID: mdl-36138686

RESUMO

BACKGROUND: The aim of this review is to discuss experimental and clinical techniques and interventions of fetal surgery which have been performed minimally invasively by the means of a three-port approach for the fetoscope and instruments for the left and right hand of the surgeon (bimanual minimally invasive fetal surgery). METHODS: a print and electronic literature search was performed; the titles and abstracts were screened and included reports were reviewed in a two-step approach. First, reports other than minimally invasive fetal surgery were excluded, then a full text review and analysis of the reported data was performed. RESULTS: 17 reports were included. The heterogeneity of the included reports was high. Although reports on human fetoscopic surgical procedures can be found, most of them do not pick out bimanual fetal surgery as a central theme but rather address interventions applying a fetoscope with a working channel for a laser fiber, needle or flexible instrument. Most reports were on experimentation in animal models, the human application of minimally invasive fetoscopic bimanual surgery is rare and has at best been explored for the prenatal treatment of spina bifida. Some reported bimanual fetoscopic procedures were performed on the exteriorized uterus via a maternal laparotomy and can therefore not be classified as being truly minimally invasive. DISCUSSION: our results demonstrate that minimally invasive fetoscopic bimanual surgery is rare, even in animal models, excluding many other techniques and procedures that are loosely termed 'minimally invasive fetal surgery' which we suggest to better label as 'interventions'. Thus, more research on percutaneous minimally invasive bimanual fetoscopic surgery is warranted, with the aim to reduce the maternal, uterine and fetal trauma for correction of congenital malformations.

3.
Children (Basel) ; 9(3)2022 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-35327788

RESUMO

(1) Background: The morbidity of gastroschisis is defined by exposure of unprotected intestines to the amniotic fluid leading to inflammatory damage and consecutive intestinal dysmotility, the viscero-abdominal disproportion which results in an abdomen too small to incorporate the herniated and often swollen intestine, and by associated pathologies, such as in complex gastroschisis. To prevent intestinal damage and to provide for growth of the abdominal cavity, fetal interventions such as amnio exchange, gastroschisis repair or covering have been evaluated in several animal models and human trials. This review aims to evaluate the reported techniques for the fetal treatment of gastroschisis by focusing on minimally invasive procedures. (2) Methods: We conducted a systematic database search, quality assessment and analyzed relevant articles which evaluate or describe surgical techniques for the prenatal surgical management of gastroschisis in animal models or human application. (3) Results: Of 96 identified reports, 42 eligible studies were included. Fetal interventions for gastroschisis in humans are only reported for EXIT procedures and amnio exchange. In animal models, particularly in the fetal sheep model, several techniques of open or minimally invasive repair of gastroschisis or covering the intestine have been described, with fetoscopic covering being the most encouraging. (4) Discussion: Although some promising minimally invasive techniques have been demonstrated in human application and animal models, most of them are still associated with relevant fetal morbidity and mortality and barely appear to be currently applicable in humans. Further research on specific procedures, instruments and materials is needed before any human application.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA