Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 57
Filtrar
1.
Turk Gogus Kalp Damar Cerrahisi Derg ; 32(2): 225-227, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38933322

RESUMO

Carotid body tumors are rarely encountered pathologies in the pediatric age group but still exist in the differential diagnosis of cervical painless masses. Genetic and familial background should be studied in addition to contrast imaging studies. Complete subadventitial resection, with or without prior embolization, which is still controversial, is the mainstay of therapy. Follow-up gains importance due to its nature. Herein, we report a nine-yearold girl presented with a unilateral asymptomatic mass on the neck with a diagnosis of carotid body tumor treated surgically without embolization. We emphasize the specific aspects of the pediatric age group.

2.
Turk Gogus Kalp Damar Cerrahisi Derg ; 31(4): 489-497, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38075987

RESUMO

Background: This study aims to investigate the effect of large proximal aortic neck diameter on post-endovascular aneurysm repair clinical outcomes. Methods: A total of 180 patients (168 males, 12 females; mean age: 69.9±7.4 years; range, 46 to 88 years) who underwent elective endovascular aneurysm repair between June 2016 and September 2021 were retrospectively analyzed. According to the proximal infrarenal aortic neck diameter, the patients were divided into two groups: Group 1 (<25 mm; normal aortic neck) and Group 2 (≥25 mm; pre-aneurysmatic aortic neck). Patient characteristics, proximal infrarenal aortic neck diameter measurements with computed tomography angiography, and clinical outcomes were recorded. The primary endpoint was to assess post-endovascular aneurysm repair aortic neck dilatation, mortality, endoleaks, overall survival, type 1a endoleaks-free survival, and eventfree survival regarding the groups. Results: There was no statistically significant difference in early mortality (p=0.55) and type 1a endoleak incidence between the groups (p=0.55). In Group 1, the mean change in diameter A (proximal infrarenal level) was 2.89±1.74 mm (p=0.01), and it was 2.31±2.1 mm in diameter B (proximal pre-aneurysm-sac level) (p=0.01). The mean change in Group 2 was 2.8±3.4 mm for diameter A (p<0.01) and 2.22±2.3 mm for diameter B (p<0.01). Aortic neck dilatation rates were similar between the groups (p=0.82 for diameter A; p=0.78 for diameter B). The five-year survival, event-free survival, and type 1a endoleak-free survival were also similar (p=0.54, p=0.26, p=0.24, respectively). Conclusion: Our study results showed that patients with <25 mm and ≥25-mm aortic neck diameters had similar mid-term results and aortic neck dilatation ratio. Endovascular aneurysm repair outcomes can be improved with careful patient and graft selection, and early intervention for complications.

3.
Turk Gogus Kalp Damar Cerrahisi Derg ; 31(3): 420-421, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37664782

RESUMO

Artificial intelligence can be employed in many cardiological applications including image analysis, risk assessment, and patient monitoring. In the catheterization laboratory, it can act as a physician assistant, technician, or co-worker. First, by giving voice commands to the operator of the coronary angiography machine, it can ensure that the C-arm moves to the desired angle. It is able to make recommendations for stent size and type based on the analysis of angiography images which is also possible for peripheral and carotid interventions. For transcatheter aortic valve implantation, it can make recommendations for valve placement and size. Artificial intelligence-based image analysis algorithms can be used to support image analysis during catheter laboratory procedures. The challenges include the need for large, high-quality data sets and the development of accurate, reliable, and interpretable artificial intelligence algorithms.

4.
Kardiochir Torakochirurgia Pol ; 20(2): 72-76, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37564957

RESUMO

Introduction: Sternal closure still causes morbidity/mortality following sternotomy. Robicsek weave, cable systems, rigid plates and nitinol clips are systems employed to prevent sternal dehiscence. Aim: The aim was to document the effectiveness of a novel method using standard sternal wires decreasing load on wires and spreading load on the lateral sternum to prevent sternal cutting by wires and thus sternal dehiscence. Material and methods: 756 patients who underwent coronary revascularization with sternotomy between July 2018 and November 2022 were retrospectively analyzed. Fifty patients with "/"wiring were compared with 50 patients with Robicsek weave by propensity score matching. "/" wiring (Durukan weave) spreads load laterally on the sternum by lateral sequential knotting of wires instead of midline knotting. Outcomes were superficial and deep sternal wound infection and non-infectious sternal dehiscence. Results: There were 50 patients in each group. Mean age of the patients was 65.74 ±7.47 in Robicsek weave and 66.12 ±7.23 in Durukan weave. The perioperative characteristics of patients were comparable as propensity score matching was performed. None developed superficial sternal wound infection in Robicsek weave, whereas 2% (1) in "/"wiring. There was no deep sternal wound infection in each group. Non-infectious sternal dehiscence did not occur in either group. Conclusions: "/" wiring seems to be a safe and cost-effective method for sternal closure for preventing sternal cutting by wires, therefore preventing sternal wound related problems and dehiscence. The method is cheap, easily applicable and less time consuming than Robicsek weave, which was proven to be the safest method for sternal wire closure.

5.
Kardiochir Torakochirurgia Pol ; 18(1): 50-54, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34552644

RESUMO

INTRODUCTION: Abdominal aortic aneurysms represent the majority of all aneurysms of the aorta. Endovascular aneurysm repair (EVAR) is an alternative procedure to surgical repair. Although general and regional anaesthesia are frequently used during EVAR procedures, local anaesthesia has become one of the anaesthesia options for which there is increasing experience. AIM: We reported our EVAR cases in which we routinely used femoral local anaesthesia. MATERIAL AND METHODS: Between August 2016 and June 2020, the EVAR procedure was applied to 22 infrarenal abdominal aortic aneurysm patients under femoral local anaesthesia. Open femoral artery access through a groin incision was used in all patients. Patients were followed up for graft- and wound-related complications. RESULTS: The mean age of the patients was 72.59 ±6.6 years (min: 60, max: 84). Mean aneurysm sac diameter was 61.04 ±8.76 mm. Bifurcated stent graft was used in 21 (95.5%) patients. An aorto-uni-iliac stent graft was used for 1 (4.5%) patient due to contralateral total iliac occlusion. Endoleak was observed in 6 patients. In-hospital mortality was observed in 2 patients; both cases were ruptured with haemodynamic instability (9%). Revision in the groin area was performed in 3 (13.6%) patients due to local wound complications. CONCLUSIONS: Although the EVAR procedure has been described as a safer and more easily applicable alternative to surgical repair, it is disadvantageous in terms of increasing treatment costs. Anaesthesia preference and incision size with a more minimalist approach can reduce the length of hospital stay and minimize the complications that may occur after the procedure, resulting in decreased costs.

7.
Turk Gogus Kalp Damar Cerrahisi Derg ; 29(1): 20-26, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33768977

RESUMO

BACKGROUND: In this study, we aimed to investigate the potential role of 3D-printed physical and digital anatomical models in pre-procedural planning, practice and training in lower extremity arterial interventions. METHODS: A total of 16 patients (9 males, 7 females; mean age: 72.1±1.5 years; range, 69 to 75 years) who underwent superficial femoral artery balloon angioplasty between February 2016 and April 2019 were retrospectively reviewed for vascular access site preference and balloon sizing. Pre-procedural computed tomography volumetric images used for diagnosis were analyzed and modeled with 3D printing. Procedural and 3D-based data regarding the size of the balloon and deployment sites and the severity of the stenosis were compared. RESULTS: Measurements obtained from 3D models manually and segmentation images from software were similar (p>0.05). Both were smaller than the actual size of balloons used (p<0.001). Stenosis severity was similar with manual and software methods and both were significantly lower than the reported quantitative angiographic measurements (p<0.001). Vascular access site preference was changed in five (31.2%) patients, when the model was simulated by a non-sterile practice on 3D-printed physical models. The wire and catheter selection differed in eight patients, while practicing with models. CONCLUSION: The planning and practicing of lower extremity arterial procedures with 3D models may reduce operator-dependent variables, avoid unnecessary interventions, reduce endothelial damage, and increase procedural success. The 3D-printed models may be used for educational purposes for medical professionals.

8.
Turk Gogus Kalp Damar Cerrahisi Derg ; 29(4): 562-576, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35096459

RESUMO

These evidence-based guidelines from the Turkish Society of Cardiovascular Surgery, National Society of Vascular and Endovascular Surgery, and Phlebology Society intend to support clinicians in best decisions regarding the treatment of venous thromboembolism (VTE). The Editor was selected by the three national societies and was tasked with the recruitment of the recognized panel. All financial support was solely derived from the sponsoring societies without the direct involvement of industry or other external stakeholders. The panel prioritized clinical questions and outcomes according to their importance for clinicians in terms of VTE. The panel agreed on 42 recommendations under 15 headings for the diagnosis, initial management, secondary prevention of VTE, and treatment of recurrent VTE events. Important recommendations included the use of ultrasonography, preference for home treatment over hospital treatment for uncomplicated VTE, preference for direct oral anticoagulants (DOACs) over vitamin K antagonists for primary treatment of cancer and non-cancer-related VTE, extended or indefinite anticoagulation with DOACs in selected high-risk patients. Early catheter-directed thrombectomy was recommended in only young symptomatic patients with a diagnosis of fresh iliofemoral deep vein thrombosis.

9.
Kardiochir Torakochirurgia Pol ; 17(3): 137-142, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33014089

RESUMO

INTRODUCTION: Carotid artery stenosis of 50% or more in the extracranial internal carotid artery is responsible for 10-15% of all strokes. Interventional treatment options include carotid endarterectomy and carotid artery stenting, where endarterectomy is proven to be superior. AIM: In this study, we report the carotid endarterectomy results of patients we operated on using the strategy we termed the "one fits all strategy". MATERIAL AND METHODS: Seventy-six patients undergoing carotid endarterectomy between July 2016 and April 2020 were retrospectively studied. Conventional endarterectomy under general anesthesia with primary closure of the arteriotomy was performed in all patients. We used a near infrared spectroscopy oximeter to measure regional cerebral oxygenation continuously throughout the surgery. RESULTS: The mean age of the patients was 70.96 8.15 years. There were 52 male and 24 female patients. The mean follow-up time was 20.6 ±13.6 months. Coronary artery disease was detected in 52 (73.6%) patients. Coronary artery bypass operation was indicated in 19 patients in whom a staged approach was performed in 13 and a reverse staged approach in 1. There were two perioperative strokes one of which recovered fully spontaneously and the other partially with physiotherapy. Eight cases were revised due to hematoma formation. CONCLUSIONS: Carotid endarterectomy continues to prove its safety in carotid artery stenosis patients. Continuous cerebral oxygenation monitoring is indispensable for carotid surgery. Despite discrepancies in surgical techniques, we believe that "one fits all strategy: general anesthesia, conventional endarterectomy without patch plasty, never shunter and always NIRS monitorization" may be used safely in patients undergoing carotid endarterectomy.

10.
Heart Surg Forum ; 23(2): E118-E122, 2020 03 11.
Artigo em Inglês | MEDLINE | ID: mdl-32364895

RESUMO

BACKGROUND: Predisposition to atrial fibrillation in mitral valve surgery has been well demonstrated. The changes in electrocardiographic parameters (Pmax, Pmin and P-wave dispersion) related to AF risk are unknown. We aimed to document the relationship between electrocardiographic changes and mitral valve replacement through right or left atrial surgical approaches. METHODS: We retrospectively studied 154 patients, who underwent mitral valve replacement surgery from 2008 to 2018. Seventy-nine patients were operated with right atriotomy and transseptal approach (Group 1), and 75 patents were operated with left atriotomy (Group 2). ECGs obtained at hospital admittance and postoperatively at 24 hours were blindly analyzed. RESULTS: Preoperative demographic characteristics were similar. Pmax, Pmin and P-wave dispersion were similar preoperatively. All parameters increased in both groups compared with the preoperative values (P < .05). Postoperative Pmax, Pmin and P-wave dispersion all were statistically significantly higher with the right atrial approach (P < .05). Postoperative AF also was more common in Group 1 (P < .05). CONCLUSION: Right atrial approach may lead to higher P-wave changes and atrial arrhythmias. This may be due to more extensive surgical disruption. The changes in atrial anatomic structure can increase atrial arrhythmic propensity and can cause atrial fibrillation.


Assuntos
Apêndice Atrial/cirurgia , Septo Interatrial/cirurgia , Eletrocardiografia , Implante de Prótese de Valva Cardíaca/métodos , Estenose da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Cardiopatia Reumática/complicações , Adulto , Feminino , Seguimentos , Frequência Cardíaca/fisiologia , Humanos , Masculino , Estenose da Valva Mitral/etiologia , Estenose da Valva Mitral/fisiopatologia , Estudos Retrospectivos , Cardiopatia Reumática/cirurgia , Resultado do Tratamento
11.
Heart Surg Forum ; 23(2): E135-E139, 2020 03 16.
Artigo em Inglês | MEDLINE | ID: mdl-32364900

RESUMO

BACKGROUND: The optimal length of saphenous vein grafts can be challenging in surgical coronary revascularization. It is the cornerstone for graft patency. In this study, we tried to demonstrate the value of 3D printing in determining optimal saphenous graft length. METHODS: Sixteen patients who underwent bypass surgery with only vein grafts were examined. Patients' measurements of graft lengths were obtained from postoperative CT images and from both 3D print models manually with plastic tubes and via 3D print digital images of Mimics software during segmentation. Another measurement was done using the Fit Centerline tool in the analysis module of Mimics software after segmentation. These 3 measurements were compared. RESULTS: There was a statistically significant difference between 3 measurement methods for each graft length (P < .001). Measurements of actual grafts were longer than measurements of 3D printed models manually and segmentation images from software were similar (P > .05). CONCLUSION: 3D printing models and their software may be used to determine optimal saphenous graft length and the anastomosis site to decrease operation time. It can be deducted from these results that 3D printing is a promising method for reducing operator dependent variables in adjusting graft size and finding optimal anastomosis sites.


Assuntos
Ponte de Artéria Coronária/métodos , Doença da Artéria Coronariana/cirurgia , Impressão Tridimensional , Veia Safena/transplante , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos
12.
Kardiochir Torakochirurgia Pol ; 17(4): 189-192, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33552182

RESUMO

INTRODUCTION: Veno-venous extracorporeal membrane oxygenation (ECMO) support has been used for respiratory insufficiency. Its role in blood oxygenation has been well documented. However, the effects on myocardial electrophysiology have not been studied in detail. AIM: To reveal the acute effects of extracorporeal support on new electrocardiography (ECG) parameters in patients with preserved left ventricular functions. MATERIAL AND METHODS: This retrospective study was conducted in three separate clinics. Sixteen consecutive patients under veno-venous ECMO for respiratory insufficiency who soon could be successfully weaned were analyzed. Immediately before and 2 hours after initiation of ECMO, ECG was performed. P wave, QT, QTc and T wave peak to end were measured and calculated from obtained surface 12-lead ECG. RESULTS: There were statistically significant differences immediately before and 2 hours after initiation of ECMO treatment in the Tp-e interval and Tp-e/QTc ratio, the maximum QTc, minimum QTc, and QTc dispersion values, and P wave dispersion (p < 0.0001 for each). All ECG parameters were significantly decreased with ECMO support. CONCLUSIONS: All atrial and ventricular repolarization parameters were decreased in patients with VV-ECMO support. Despite the limited role of ECMO in intractable arrhythmias, the findings of the study revealed that ECMO therapy for respiratory insufficiency may improve atrial ventricular depolarization and repolarization. Therefore, simple 12-lead surface ECG with new ECG parameters may be evaluated for better outcomes.

13.
Turk Gogus Kalp Damar Cerrahisi Derg ; 28(4): 706-707, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33403150

RESUMO

Cannulation of the shorter limb of an abdominal aortic endograft can be demanding. Confirmation of the accurate cannulation is equally challenging. Interventional cardiologists and cardiovascular surgeons may encounter certain difficulties during this procedure. In particular, cardiologists have a wide variety of experience in interventions from coronary practice. This novel method we describe herein consists of peripheral balloon usage in wiring the short limb of an aortic stent graft. In this method, an over-the-wire peripheral balloon is employed to centralize the wire at the gate of the short limb. The centralized wire in three-dimensional arterial lumen can cross the short limb of the graft easily.

14.
Kardiochir Torakochirurgia Pol ; 16(2): 88-92, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31410096

RESUMO

INTRODUCTION: Amiodarone, a pharmaceutical extensively used to suppress atrial and ventricular tachyarrhythmias, is also known to cause many side effects on many tissues. N-acetyl-cysteine (NAC), vitamin E and vitamin C are known as antioxidants for their ability to minimize oxidative stress. In the peer-reviewed literature, there is no study reporting on the protective effects of these antioxidant agents against its hepatotoxicity. AIM: We investigated the oxidative effects of NAC, vitamins E and C on liver tissue after amiodarone treatment. MATERIAL AND METHODS: Rats were randomly assigned to: control; amiodarone group; amiodarone + NAC treated group; amiodarone + Vit. E group and amiodarone + Vit. C group. Liver tissues were isolated from animals and total glutathione levels were measured. RESULTS: In all time intervals, the level of glutathione increased. When all time intervals were compared, the amiodarone group revealed the lowest levels. The antioxidant co-administered group was studied; the glutathione levels were statistically significantly higher than the sole amiodarone group. When vitamins E, C or N-acetyl cysteine were examined, there was no statistically significant difference among them. CONCLUSIONS: In this study we found that hepatotoxicity capacity of amiodarone may be reduced by taking up antioxidants. In addition, the effect documented here may be reproducible and may be applied to clinical settings.

15.
Turk Gogus Kalp Damar Cerrahisi Derg ; 27(2): 185-191, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32082851

RESUMO

BACKGROUND: This study aims to investigate the cytotoxic effects and apoptotic potential of N-butyl cyanoacrylate and 2-octyl cyanoacrylate used in surgical treatment of chronic venous insufficiency. METHODS: N-butyl cyanoacrylate and 2-octyl cyanoacrylate were cultured in cell-culture using human umbilical endothelial cell-line. Cytotoxicity and viability were assessed at 24 and 72 hours with lactate dehydrogenase and 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide assays, respectively. Apoptotic potential was documented at 24 and 72 hours with relative caspase-3 activity. RESULTS: The mean cytotoxicity at 24 and 72 hours were: N-butyl cyanoacrylate with an area of dot/line: 37.0±3.9%/29.3±2.7% and 46.4±1.6%/45.1±7.1%, 2-octyl cyanoacrylate with an area of dot/line: 39.0±7.0%/37.3±4.6% and 47.0±2.3%/40.7±7.5%. Cytotoxicity increased by time in each group (p<0.05). The mean viability at 24 and 72 hours were: N-butyl cyanoacrylate with an area of dot/line: 53.4±7.7%/72.0±5.7% and 35.7±1.9%/37.8±3.7%, 2-octyl cyanoacrylate with an area of dot/line: 54.3±4.4%/73.5±19.9% and 33.6±2.8%/30.7±4.5%. The mean viability decreased by time in each group (p<0.05). The mean relative caspase-3 activity at 24 and 72 hours were: control group: 0.084±0.006 and 0.065±0.002, N-butyl cyanoacrylate with an area of dot/line: 0.940±0.037/0.924±0.053 and 0.999±0.072/1.056±0.015, 2-octyl cyanoacrylate with an area of dot/line: 0.900±0.044/0.928±0.018 and 0.989±0.084/0.999±0.072. The mean relative caspase-3 activity was higher than control group in each group at each time interval (p<0.05) and activity increased by time in N-butyl cyanoacrylate line and in 2-octyl cyanoacrylate line groups (p<0.05). CONCLUSION: Our findings indicate that N-butyl cyanoacrylate and 2-octyl cyanoacrylate cause cytotoxicity in cell-culture media. We may also postulate that they induce apoptosis in cell-culture media.

16.
Turk Gogus Kalp Damar Cerrahisi Derg ; 27(4): 580-582, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32082930

RESUMO

Iatrogenic aortocoronary venous fistula arising from anastomosing an aortocoronary graft to a cardiac vein is a rare a complication following coronary artery bypass grafting. A 75-year-old male patient was admitted with recurrent angina accompanied by congestive heart failure six years after surgery. He was diagnosed with an acquired saphenous vein graft-to- cardiac vein fistula. Based on the estimation of risks versus benefits, the heart team decided to perform percutaneous closure with a vascular occlusion device. Subsequently, complaints and echocardiographic findings of the patient resolved.

17.
Turk Gogus Kalp Damar Cerrahisi Derg ; 28(2): 294-300, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32551159

RESUMO

BACKGROUND: We aimed to investigate the potential role of threedimensional printed anatomical models in pre-procedural planning, practice, and selection of carotid artery stent and embolic protection device size and location. METHODS: A total of 16 patients (10 males, 6 females; mean age 75.6±4.7 years; range, 68 to 81 years) who underwent carotid artery stenting with an embolic protection device between January 2017 and February 2019 were retrospectively analyzed. The sizing was based on intraprocedural angiography findings with the same brand stent using distal protection device. Pre-procedural computed tomography angiography images used for diagnosis were obtained and modeled with three-dimensional printing method. Pre-procedural and threedimensional data regarding the size of stents and protection devices and implantation sites were compared. RESULTS: Measurements obtained from three-dimensional models manually and segmentation images from software were found to be similar and both were smaller than actually used for stent and embolic protection device sizes. The rates of carotid artery stenosis were similar with manual and software methods, but were lower than the quantitative angiographic measurements. Device implantation sites detected by the manual and software methods were different than the actual setting. CONCLUSION: The planning and practicing of procedure with threedimensional models may reduce the operator-dependent variables, shorten the operation time, decrease X-ray exposure, and increase the procedural success.

19.
Kardiochir Torakochirurgia Pol ; 14(1): 43-46, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28515748

RESUMO

INTRODUCTION: Warfarin is commonly used to avoid thromboembolism, predominantly for cardiovascular pathologies. However, the consumption of several herbal products is not permitted during its use due to the associated interactions. Propolis is a popular phytotherapy product made by honey bees. The use of propolis has been dramatically increasing in recent times. AIM: To evaluate the possible interactions between propolis and warfarin in a mouse model with determination of the international normalized ratio (INR) values. MATERIAL AND METHODS: CD-1 mice were employed in the experimental model. The mice were warfarinized, and propolis was administered simultaneously. The INR values were obtained. All animals were sacrificed at the end of the study. RESULTS: The baseline INR value was 0.8 ±0.1. After 72 h, the INR value increased as expected. The INR value was 7.28 ±1.08 in the control group and 5.8 ±2.88 in the propolis group. At the end of the study, the INR value was 1.3 ±0.37. Propolis interacted with warfarin and caused a decrease in the INR value. CONCLUSIONS: Propolis interactions, especially with warfarin, should be kept in mind and further studied. Healthcare specialists should be aware of this possible interaction between warfarin and propolis and inform patients about it.

20.
Kardiochir Torakochirurgia Pol ; 13(2): 143-4, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27516788

RESUMO

Electrical failure during cardiopulmonary bypass is a crisis situation for the cardiac surgical team. Fortunately, it has a low incidence with low morbidity and mortality rates. Notwithstanding, institutional preventative and management measures should be taken. Here, we report a case of electrical failure during cardiopulmonary bypass, which was successfully managed during the surgery, allowing the patient to recover uneventfully. These unwanted complications can only be managed by promoting awareness and putting in place strategies against them.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA