Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
J Cardiovasc Magn Reson ; 26(1): 100007, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38211509

RESUMO

"Cases of SCMR" is a case series on the SCMR website (https://www.scmr.org) for the purpose of education. The cases reflect the clinical presentation, and the use of cardiovascular magnetic resonance (CMR) in the diagnosis and management of cardiovascular disease. The 2022 digital collection of cases are presented in this manuscript.


Assuntos
Doenças Cardiovasculares , Valor Preditivo dos Testes , Humanos , Doenças Cardiovasculares/diagnóstico por imagem , Doenças Cardiovasculares/terapia , Pessoa de Meia-Idade , Feminino , Masculino , Idoso , Imageamento por Ressonância Magnética , Adulto , Prognóstico , Adulto Jovem
2.
Math Biosci Eng ; 20(9): 15982-15998, 2023 08 04.
Artigo em Inglês | MEDLINE | ID: mdl-37919998

RESUMO

The accurate visualization and assessment of the complex cardiac and pulmonary structures in 3D is critical for the diagnosis and treatment of cardiovascular and respiratory disorders. Conventional 3D cardiac magnetic resonance imaging (MRI) techniques suffer from long acquisition times, motion artifacts, and limited spatiotemporal resolution. This study proposes a novel time-resolved 3D cardiopulmonary MRI reconstruction method based on spatial transformer networks (STNs) to reconstruct the 3D cardiopulmonary MRI acquired using 3D center-out radial ultra-short echo time (UTE) sequences. The proposed reconstruction method employed an STN-based deep learning framework, which used a combination of data-processing, grid generator, and sampler. The reconstructed 3D images were compared against the start-of-the-art time-resolved reconstruction method. The results showed that the proposed time-resolved 3D cardiopulmonary MRI reconstruction using STNs offers a robust and efficient approach to obtain high-quality images. This method effectively overcomes the limitations of conventional 3D cardiac MRI techniques and has the potential to improve the diagnosis and treatment planning of cardiopulmonary disorders.


Assuntos
Coração , Imageamento por Ressonância Magnética , Imageamento por Ressonância Magnética/métodos , Coração/diagnóstico por imagem , Pulmão/diagnóstico por imagem , Imageamento Tridimensional/métodos , Movimento (Física) , Processamento de Imagem Assistida por Computador/métodos
3.
Pediatr Radiol ; 53(11): 2188-2196, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37563320

RESUMO

BACKGROUND: Intravenous adenosine induces pharmacological stress by causing vasodilatation and thus carries the risk of severe hypotension when combined with vasodilatory effects of anesthetic agents. OBJECTIVE: This study describes our experience with a reduced dose adenosine cardiac magnetic resonance imaging (MRI) protocol in young children under general anesthesia (GA). MATERIALS AND METHODS: This is a retrospective report of all patients from birth to 18 years who underwent adenosine stress cardiac MRI under GA between August 2018 and November 2022. Based on our anecdotal experience of severe adverse effects in patients receiving adenosine infusion under GA and in discussion with the pediatric anesthesia team, we developed a modified protocol starting at a dose of 110 mcg/kg/min with incremental escalation to a full dose of 140 mcg/kg/min to achieve desired hemodynamic effect. RESULTS: Twenty-two children (mean age 6.5 years, mean weight 28 kg) satisfied the inclusion criteria. The diagnoses included Kawasaki disease (7), anomalous aortic origin of left coronary artery (3), anomalous aortic origin of right coronary artery (2), coronary fistula (3), repaired d-transposition of great arteries (2), repaired anomalous left coronary artery from pulmonary artery (2), repaired truncus arteriosus with left coronary artery occlusion (1), extracardiac-Fontan with left coronary artery myocardial bridge (1), and post heart transplantation (1). Nine patients needed dose escalation beyond 110 mcg/kg/min. Two patients had transient hypotension during testing (systemic blood pressure drop > 25 mmHg). No patient developed significant heart block or bronchospasm. Six patients (repeat study in one) demonstrated inducible perfusion defects (27%) on stress perfusion sequences-5 of whom had confirmed significant coronary abnormalities on angiography or direct surgical inspection. CONCLUSION: A reduced/incremental dose adenosine stress cardiac MRI protocol under GA in children is safe and feasible. This avoids severe hypotension which is both unsafe and may result in inaccurate data.

5.
Clin Pediatr (Phila) ; 57(12): 1436-1441, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-29993270

RESUMO

We conducted a retrospective study to identify electrocardiogram (ECG) and echocardiogram utilization among patients presenting for a follow-up cardiology evaluation with innocent heart murmur between 2012 and 2014. The 2014 echocardiogram Appropriate Use Criteria was applied. We observed high rates of ordering ECGs and echocardiograms on follow-up visits (79% and 36%); only 1 patient had an appropriate indication for echocardiogram while the rest had rarely appropriate indication. Having had an ECG done did not affect echocardiogram ordering behavior. Older patient age was the only factor associated with a higher likelihood for ordering echocardiograms on follow-up visit (odds ratio = 1.016, P = .021). In this small sample study, we noticed high rates of test utilization and low-probability utilization of echocardiogram in the recurrent evaluation of children with innocent heart murmur. A larger, multicenter prospective study to investigate patterns and drivers of test utilization in children with innocent heart murmur presenting for a follow-up cardiology visit is needed.


Assuntos
Ecocardiografia/estatística & dados numéricos , Sopros Cardíacos/diagnóstico , Criança , Pré-Escolar , Ecocardiografia/métodos , Feminino , Seguimentos , Humanos , Masculino , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA