Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 43
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Soft Matter ; 20(26): 5095-5104, 2024 Jul 03.
Artigo em Inglês | MEDLINE | ID: mdl-38888165

RESUMO

The mechanical properties of soft gels hold significant relevance in biomedicine and biomaterial design, including the development of tissue engineering constructs and bioequivalents. It is important to adequately characterize the gel's mechanical properties since they play a role both in the overall structural properties of the construct and the physiological responses of cells. The question remains which approach for the mechanical characterization is most suitable for specific biomaterials. Our investigation is centered on the comparison of three types of gels and four distinct mechanical testing techniques: shear rheology, compression, microindentation, and nanoindentation by atomic force microscopy. While analyzing an elastic homogeneous synthetic hydrogel (a polyacrylamide gel), we observed close mechanical results across the different testing techniques. However, our findings revealed more distinct outcomes when assessing a highly viscoelastic gel (Ecoflex) and a heterogeneous biopolymer hydrogel (enzymatically crosslinked gelatin). To ensure precise data interpretation, we introduced correction factors to account for the boundary conditions inherent in many of the testing methods. The results of this study underscore the critical significance of considering both the temporal and spatial scales in mechanical measurements of biomaterials. Furthermore, they encourage the employment of a combination of diverse testing techniques, particularly in the characterization of heterogeneous viscoelastic materials such as biological samples. The obtained results will contribute to the refinement of mechanical testing protocols and advance the development of soft gels for tissue engineering.


Assuntos
Materiais Biocompatíveis , Hidrogéis , Teste de Materiais , Materiais Biocompatíveis/química , Hidrogéis/química , Elasticidade , Reologia , Viscosidade , Resinas Acrílicas/química , Gelatina/química , Engenharia Tecidual
2.
Int J Mol Sci ; 25(3)2024 Feb 03.
Artigo em Inglês | MEDLINE | ID: mdl-38339139

RESUMO

Macrophages are the major players and orchestrators of inflammatory response. Expressed proteins and secreted cytokines have been well studied for two polar macrophage phenotypes-pro-inflammatory M1 and anti-inflammatory regenerative M2, but little is known about how the polarization modulates macrophage functions. In this study, we used biochemical and biophysical methods to compare the functional activity and mechanical properties of activated human macrophages differentiated from monocyte with GM-CSF (M0_GM) and M-CSF (M0_M) and polarized into M1 and M2 phenotypes, respectively. Unlike GM-CSF, which generates dormant cells with low activity, M-CSF confers functional activity on macrophages. M0_M and M2 macrophages had very similar functional characteristics-high reactive oxygen species (ROS) production level, and higher phagocytosis and survival compared to M1, while M1 macrophages showed the highest radical-generating activity but the lowest phagocytosis and survival among all phenotypes. All phenotypes decreased their height upon activation, but only M1 and M2 cells increased in stiffness, which can indicate a decrease in the migration ability of these cells and changes in their interactions with other cells. Our results demonstrated that while mechanical properties differ between M0 and polarized cells, all four phenotypes of monocyte-derived macrophages differ in their functional activities, namely in cytokine secretion, ROS production, and phagocytosis. Within the broad continuum of human macrophages obtained in experimental models and existing in vivo, there is a diversity of phenotypes with varying combinations of both markers and functional activities.


Assuntos
Fator Estimulador de Colônias de Granulócitos e Macrófagos , Fator Estimulador de Colônias de Macrófagos , Humanos , Fator Estimulador de Colônias de Granulócitos e Macrófagos/farmacologia , Fator Estimulador de Colônias de Granulócitos e Macrófagos/metabolismo , Fator Estimulador de Colônias de Macrófagos/metabolismo , Espécies Reativas de Oxigênio/metabolismo , Macrófagos/metabolismo , Fagocitose , Fenótipo
3.
Mol Biol Cell ; 35(4): ar47, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38354034

RESUMO

Neuronal growth cones sense a variety of cues including chemical and mechanical ones to establish functional connections during nervous system development. Substrate-cytoskeletal coupling is an established model for adhesion-mediated growth cone advance; however, the detailed molecular and biophysical mechanisms underlying the mechanosensing and mechanotransduction process remain unclear. Here, we adapted a motor-clutch model to better understand the changes in clutch and cytoskeletal dynamics, traction forces, and substrate deformation when a growth cone interacts with adhesive substrates of different stiffnesses. Model parameters were optimized using experimental data from Aplysia growth cones probed with force-calibrated glass microneedles. We included a reinforcement mechanism at both motor and clutch level. Furthermore, we added a threshold for retrograde F-actin flow that indicates when the growth cone is strongly coupled to the substrate. Our modeling results are in strong agreement with experimental data with respect to the substrate deformation and the latency time after which substrate-cytoskeletal coupling is strong enough for the growth cone to advance. Our simulations show that it takes the shortest time to achieve strong coupling when substrate stiffness was low at 4 pN/nm. Taken together, these results suggest that Aplysia growth cones respond faster and more efficiently to soft than stiff substrates.


Assuntos
Cones de Crescimento , Mecanotransdução Celular , Cones de Crescimento/metabolismo , Actinas/metabolismo , Citoesqueleto/metabolismo , Células Fotorreceptoras Retinianas Cones
4.
J Funct Biomater ; 14(12)2023 Dec 11.
Artigo em Inglês | MEDLINE | ID: mdl-38132818

RESUMO

The interaction of different dental alloys with the oral environment may cause severe side effects (e.g., burning sensation, inflammatory reactions, carcinogenesis) as a result of oral galvanism. However, the pathogenesis of side effects associated with oral galvanism is still unclear, and the effects of direct current and alloy corrosion ions are considered potentially contributing factors. Therefore, the aim of this study was to systemically compare the damaging effects of (1) galvanism as a synergistic process (direct current + corrosion ions), (2) direct current separately, and (3) corrosion ions separately on an in vitro mucosa-like model based on a cell line of immortalized human keratinocytes (HaCaTs) to reveal the factors playing a pivotal role in dental alloys side effects. For this, we chose and compared the dental alloys with the highest risk of oral galvanism: Ti64-AgPd and NiCr-AgPd. We showed that galvanic current may be the leading damaging factor in the cytotoxic processes associated with galvanic coupling of metallic intraoral appliances in the oral cavity, especially in the short-term period (28 days). However, the contribution of corrosion ions (Ni2+) to the synergistic toxicity was also shown, and quite possibly, in the long term, it could be no less dangerous.

5.
Cells ; 12(21)2023 11 06.
Artigo em Inglês | MEDLINE | ID: mdl-37947661

RESUMO

The biophysical properties of cells described at the level of whole cells or their membranes have many consequences for their biological behavior. However, our understanding of the relationships between mechanical parameters at the level of cell (stiffness, viscoelasticity) and at the level of the plasma membrane (fluidity) remains quite limited, especially in the context of pathologies, such as cancer. Here, we investigated the correlations between cells' stiffness and viscoelastic parameters, mainly determined via the actin cortex, and plasma membrane microviscosity, mainly determined via its lipid profile, in cancer cells, as these are the keys to their migratory capacity. The mechanical properties of cells were assessed using atomic force microscopy (AFM). The microviscosity of membranes was visualized using fluorescence-lifetime imaging microscopy (FLIM) with the viscosity-sensitive probe BODIPY 2. Measurements were performed for five human colorectal cancer cell lines that have different migratory activity (HT29, Caco-2, HCT116, SW 837, and SW 480) and their chemoresistant counterparts. The actin cytoskeleton and the membrane lipid composition were also analyzed to verify the results. The cell stiffness (Young's modulus), measured via AFM, correlated well (Pearson r = 0.93) with membrane microviscosity, measured via FLIM, and both metrics were elevated in more motile cells. The associations between stiffness and microviscosity were preserved upon acquisition of chemoresistance to one of two chemotherapeutic drugs. These data clearly indicate that mechanical parameters, determined by two different cellular structures, are interconnected in cells and play a role in their intrinsic migratory potential.


Assuntos
Citoesqueleto de Actina , Humanos , Viscosidade , Microscopia de Força Atômica/métodos , Células CACO-2 , Membrana Celular
6.
Cells ; 12(16)2023 08 09.
Artigo em Inglês | MEDLINE | ID: mdl-37626840

RESUMO

Tissue engineering has emerged as an indispensable tool for the reconstruction of organ-specific environments. Organ-derived extracellular matrices (ECM) and, especially, decellularized tissues (DCL) are recognized as the most successful biomaterials in regenerative medicine, as DCL preserves the most essential organ-specific ECM properties such as composition alongside biomechanics characterized by stiffness and porosity. Expansion of the DCL technology to cancer biology research, drug development, and nanomedicine is pending refinement of the existing DCL protocols whose reproducibility remains sub-optimal varying from organ to organ. We introduce a facile decellularization protocol universally applicable to murine organs, including liver, lungs, spleen, kidneys, and ovaries, with demonstrated robustness, reproducibility, high purification from cell debris, and architecture preservation, as confirmed by the histological and SEM analysis. The biomechanical properties of as-produced DCL organs expressed in terms of the local and total stiffness were measured using our facile methodology and were found well preserved in comparison with the intact organs. To demonstrate the utility of the developed DCL model to cancer research, we engineered three-dimensional tissue constructs by recellularization representative decellularized organs and collagenous hydrogel with human breast cancer cells of pronounced mesenchymal (MDA-MB-231) or epithelial (SKBR-3) phenotypes. The biomechanical properties of the DCL organs were found pivotal to determining the cancer cell fate and progression. Our histological and scanning electron microscopy (SEM) study revealed that the larger the ECM mean pore size and the smaller the total stiffness (as in lung and ovary), the more proliferative and invasive the mesenchymal cells became. At the same time, the low local stiffness ECMs (ranged 2.8-3.6 kPa) did support the epithelial-like SKBR-3 cells' viability (as in lung and spleen), while stiff ECMs did not. The total and local stiffness of the collagenous hydrogel was measured too low to sustain the proliferative potential of both cell lines. The observed cell proliferation patterns were easily interpretable in terms of the ECM biomechanical properties, such as binding sites, embedment facilities, and migration space. As such, our three-dimensional tissue engineering model is scalable and adaptable for pharmacological testing and cancer biology research of metastatic and primary tumors, including early metastatic colonization in native organ-specific ECM.


Assuntos
Neoplasias , Baço , Humanos , Feminino , Animais , Camundongos , Reprodutibilidade dos Testes , Sítios de Ligação , Materiais Biocompatíveis , Hidrogéis
7.
Int J Biol Macromol ; 249: 126054, 2023 Sep 30.
Artigo em Inglês | MEDLINE | ID: mdl-37532189

RESUMO

Smart thermoresponsive polymers have long attracted attention as materials of a great potential for biomedical applications, mainly for drug delivery, tissue engineering and wound dressing, with a special interest to injectable hydrogels. Poly-N-isopropylacrylamide (PNIPAM) is the most important synthetic thermoresponsive polymer due to its physiologically relevant transition temperature. However, the use of unmodified PNIPAM encounters such problems as low biodegradability, low drug loading capacity, slow response to thermal stimuli, and insufficient mechanical robustness. The use of natural polysaccharides and proteins in combinations with PNIPAM, in the form of grafted copolymers, IPNs, microgels and physical mixtures, is aimed at overcoming these drawbacks and creating dual-functional materials with both synthetic and natural polymers' properties. When developing such compositions, special attention should be paid to preserving their key property, thermoresponsiveness. Addition of hydrophobic and hydrophilic fragments to PNIPAM is known to affect its transition temperature. This review covers various classes of natural polymers - polysaccharides, fibrous and non-fibrous proteins, DNA - used in combination with PNIPAM for the prospective biomedical purposes, with a focus on their phase transition temperatures and its relation to the natural polymer's structure.


Assuntos
Polímeros , Proteínas , Estudos Prospectivos , Polímeros/química , Temperatura , Transição de Fase , Polissacarídeos , DNA
8.
Int J Biol Macromol ; 248: 125970, 2023 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-37494998

RESUMO

Poly(3-hydroxybutyrate) and chitosan are among the most widely used polymers for biomedical applications due to their biocompatibility, renewability and low toxicity. The creation of composite materials based on biopolymers belonging to different classes makes it possible to overcome the disadvantages of each of the components and to obtain a material with specific properties. Solving this problem is associated with difficulties in the selection of conditions and solvents for obtaining the composite material. In our study, acetic acid was used as a common solvent for hydrophobic poly(3-hydroxybutyrate) and chitosan. Mechanical, thermal, physicochemical and surface properties of the composites and homopolymers were investigated. The composite films had less crystallinity and hydrophobicity than poly(3-hydroxybutyrate), and the addition of chitosan caused an increase in moisture absorption, a decrease in contact angle and changes in mechanical properties of the poly(3-hydroxybutyrate). The inclusion of varying amounts of chitosan controlled the properties of the composite, which will be important in the future for its specific biomedical applications.


Assuntos
Quitosana , Quitosana/química , Ácido 3-Hidroxibutírico , Ácido Acético , Solventes
9.
Soft Matter ; 19(13): 2430-2437, 2023 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-36930054

RESUMO

Fibrin and its modifications, particularly those with functionalized polyethylene glycol (PEG), remain highly attractive as a biomaterial in drug delivery and regenerative medicine. Despite the extensive knowledge of fibrinogenesis, there is little information on the processes occurring after its modification. Previously, we found structural differences between native fibrin and its conjugates with PEG that allows us to hypothesize that a combination of methods such as terahertz (THz) pulsed spectroscopy and rheology may contribute to the characterization of gelation and reveal the effect of PEG on the polymerization dynamics. Compared to native fibrin, PEGylated fibrins had a homogenously soft surface; PEGylation also led to a significant decrease in the gelation time: from 42.75 min for native fibrin to 31.26 min and 35.09 min for 5 : 1 and 10 : 1 PEGylated fibrin, respectively. It is worth noting that THz pulsed spectroscopy makes it possible to reliably investigate only the polymerization process itself, while it does not allow us to observe statistically significant differences between the distinct PEGylated fibrin gels. The polymerization time constant of native fibrin measured by THz pulsed spectroscopy was 14.4 ± 2.8 min. However, it could not be calculated for PEGylated fibrin because the structural changes were too rapid. These results, together with those previously reported, led us to speculate that PEG-fibrin conjugates formed homogenously distributed highly water-shelled aggregates without bundling compared to native fibrin, ensuring rapid gelation and stabilization of the system without increasing its complexity.


Assuntos
Fibrina , Polietilenoglicóis , Polietilenoglicóis/química , Fibrina/química , Polimerização , Materiais Biocompatíveis/química , Medicina Regenerativa
10.
Biochim Biophys Acta Gen Subj ; 1867(6): 130348, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36977439

RESUMO

Cytotoxicity assays are essential tests in studies on the safety and biocompatibility of various substances and on the efficiency of anticancer drugs. The most frequently used assays commonly require application of externally added labels and read only collective response of cells. Recent studies show that the internal biophysical parameters of cells can be associated with the cellular damage. Therefore, using atomic force microscopy, we assessed the changes in the viscoelastic parameters of cells treated with eight different common cytotoxic agents to gain a more systematic view of the occurring mechanical changes. With the robust statistical analysis to account for both the cell-level variability and the experimental reproducibility, we have found that cell softening is a common response after each treatment. More precisely, the combined changes in the viscoelastic parameters of power-law rheology model led to a significant decrease of the apparent elastic modulus. The comparison with the morphological parameters (cytoskeleton and cell shape) demonstrated a higher sensitivity of the mechanical parameters versus the morphological ones. The obtained results support the idea of cell mechanics-based cytotoxicity tests and suggest a common way of a cell responding to damaging actions by softening.


Assuntos
Antineoplásicos , Citoesqueleto , Reprodutibilidade dos Testes , Módulo de Elasticidade , Citoesqueleto/fisiologia , Microscopia de Força Atômica/métodos
11.
Biomater Sci ; 11(2): 611-617, 2023 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-36477151

RESUMO

Super-resolution microscopy is widely used in the development of novel antimicrobial testing in vitro. In the presented work, a scanning protocol was developed by the method of scanning ion-conducting microscopy (SICM), which makes it possible to study microorganisms without rigid fixation and in saline, obtaining an index map of nanosized structures. The effect of azole and echinocandins drugs on the morphology and mechanical properties of Candida parapsilosis yeast was studied. The findings are consistent with previously proposed drug mechanisms and reports that have examined antifungal agents using AFM, SEM, and TEM. We have shown that the SICM method is capable of scanning and detecting the nanomechanical properties of yeast non-invasively.


Assuntos
Candida parapsilosis , Microscopia , Antifúngicos/farmacologia , Equinocandinas/farmacologia , Testes de Sensibilidade Microbiana , Microscopia/métodos
12.
J Biophotonics ; 16(3): e202200149, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36066126

RESUMO

Osteoarthritis (OA) is one of the most common joint diseases worldwide. Unfortunately, clinical methods lack the ability to detect OA in the early stages. Timely detection of the knee joint degradation at the level of tissue changes can prevent its progressive damage. Here, diffuse reflectance spectroscopy (DRS) in the NIR range was used to obtain optical markers of the cartilage damage grades and to assess its mechanical properties. It was observed that the water content obtained by DRS strongly correlates with the cartilage thickness (R = .82) and viscoelastic relaxation time (R = .7). Moreover, the spectral parameters, including water content (OH-band), protein content (CH-band), and scattering parameters allowed for discrimination between the cartilage damage grades (10-4 < P ≤ 10-3 ). The developed approach may become a valuable addition to arthroscopy, helping to identify lesions at the microscopic level in the early stages of OA and complement the surgical analysis.


Assuntos
Cartilagem Articular , Osteoartrite , Humanos , Cartilagem Articular/patologia , Osteoartrite/patologia , Articulação do Joelho/patologia , Análise Espectral , Água
13.
Acta Biomater ; 165: 140-152, 2023 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-36167239

RESUMO

Cell transitions between the epithelial and mesenchymal phenotypes provide the regulated morphogenesis and regeneration throughout the ontogenesis. The tissue mechanics and mechanotransduction play an essential role in these processes. Cell spheroids reproduce the cell density of native tissues and represent simple building blocks for the tissue engineering purposes. The mechanical properties of mesenchymal and epithelial cells have been extensively studied in 2D monolayer cultures, but have not been sufficiently compared in spheroids. Here, we have simultaneously applied several techniques to assess the mechanical parameters of such spheroids. The local surface mechanical properties were measured by AFM, and the bulk properties were analyzed with parallel-plate compression, as well as by observing cut opening after microdissection. The comparison of the collected data allowed us to apply the model of a solid body with surface tension, and estimate the parameters of this model. We found an expectedly higher surface tension in mesenchymal spheroids, as well as a higher bulk modulus and relaxation time. The two latter parameters agree with the bulk poroelastic behavior of spheroids, and with the higher cell density and extracellular matrix content in mesenchymal spheroids. The higher tension of the surface layer cells in mesenchymal cell spheroids was also confirmed by the viscoelastic AFM characterization. The cell phenotype affected the self-organization during the spheroid formation, as well as the structure, biomechanical properties, and spreading of spheroids. The obtained results will contribute to a more detailed description of spheroid and tissue biomechanics, and will help in controlling the tissue regeneration and morphogenesis. STATEMENT OF SIGNIFICANCE: Spheroids are widely used as building blocks for scaffold-based and scaffold-free strategies in tissue engineering. In most studies, either the concept of a solid body or a liquid with surface tension was used to describe the biomechanical behavior of spheroids. Here, we have used a model which combines both aspects, a solid body with surface tension. The "solid" aspect was described as a visco-poroelastic material, affected by the liquid redistribution through the cells and ECM at the scale of the whole spheroid. A higher surface tension was found for mesenchymal spheroids than that for epithelial spheroids, observed as a higher stiffness of the spheroid surface, as well as a larger spontaneous opening of the cut edges after microdissection.


Assuntos
Mecanotransdução Celular , Esferoides Celulares , Engenharia Tecidual , Fenótipo , Células Epiteliais
14.
ACS Appl Mater Interfaces ; 14(50): 55392-55401, 2022 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-36475602

RESUMO

Defrost sensors are a crucial element for proper functioning of the pharmaceutical cold chain. In this paper, the self-assembled peptide-based hydrogels were used to construct a sensitive defrost sensor for the transportation and storage of medications and biomaterials. The turbidity of the peptide hydrogel was employed as a marker of the temperature regime. The gelation kinetics under different conditions was studied to detect various stages of hydrogel structural transitions aimed at tuning the system properties. The developed sensor can be stored at room temperature for a long period, irreversibly indicates whether the product has been thawed, and can be adjusted to a specific temperature range and detection time.


Assuntos
Hidrogéis , Refrigeração , Hidrogéis/química , Materiais Biocompatíveis , Peptídeos/química , Temperatura
15.
Polymers (Basel) ; 14(23)2022 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-36501648

RESUMO

Biodegradable polymeric fibrous non-woven materials are widely used type of scaffolds for tissue engineering. Their morphology and properties could be controlled by composition and fabrication technology. This work is aimed at development of fibrous scaffolds from a multicomponent polymeric system containing biodegradable synthetic (polylactide, polycaprolactone) and natural (gelatin, chitosan) components using different methods of non-woven mats fabrication: electrospinning and electro-assisted solution blow spinning. The effect of the fabrication technique of the fibrous materials onto their morphology and properties, including the ability to support adhesion and growth of cells, was evaluated. The mats fabricated using electrospinning technology consist of randomly oriented monofilament fibers, while application of solution blow spinning gave a rise to chaotically arranged multifilament fibers. Cytocompatibility of all fabricated fibrous mats was confirmed using in vitro analysis of metabolic activity, proliferative capacity and morphology of NIH 3T3 cell line. Live/Dead assay revealed the formation of the highest number of cell-cell contacts in the case of multifilament sample formed by electro-assisted solution blow spinning technology.

16.
Stem Cell Res Ther ; 13(1): 317, 2022 07 16.
Artigo em Inglês | MEDLINE | ID: mdl-35842689

RESUMO

One of the severe complications occurring because of the patient's intubation is tracheal stenosis. Its incidence has significantly risen because of the COVID-19 pandemic and tends only to increase. Here, we propose an alternative to the donor trachea and synthetic prostheses-the tracheal equivalent. To form it, we applied the donor trachea samples, which were decellularized, cross-linked, and treated with laser to make wells on their surface, and inoculated them with human gingiva-derived mesenchymal stromal cells. The fabricated construct was assessed in vivo using nude (immunodeficient), immunosuppressed, and normal mice and rabbits. In comparison with the matrix ones, the tracheal equivalent samples demonstrated the thinning of the capsule, the significant vessel ingrowth into surrounding tissues, and the increase in the submucosa resorption. The developed construct was shown to be highly biocompatible and efficient in trachea restoration. These results can facilitate its clinical translation and be a base to design clinical trials.


Assuntos
COVID-19 , Engenharia Tecidual , Animais , Humanos , Lasers , Camundongos , Pandemias , Coelhos , Engenharia Tecidual/métodos , Alicerces Teciduais , Traqueia
17.
PLoS One ; 17(6): e0264903, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35657919

RESUMO

Cardiovascular diseases associated with high cholesterol (hypercholesterolemia) and low-density lipoproteins (LDL) levels are significant contributors to total mortality in developing and developed countries. Mathematical modeling of LDL metabolism is an important step in the development of drugs for hypercholesterolemia. The aim of this work was to develop and to analyze an integrated mathematical model of cholesterol metabolism in liver cells and its interaction with two types of drugs, statins and PCSK9 inhibitors. The model consisted of 21 ordinary differential equations (ODE) describing cholesterol biosynthesis and lipoprotein endocytosis in liver cells in vitro. The model was tested for its ability to mimic known biochemical effects of familial hypercholesterolemia, statin therapy, and PCSK9 inhibitors. The model qualitatively reproduced the well-known biology of cholesterol regulation, which confirms its potential for minimizing cellular research in initial testing of new drugs for cardiology.


Assuntos
Anticolesterolemiantes , Carcinoma Hepatocelular , Inibidores de Hidroximetilglutaril-CoA Redutases , Hipercolesterolemia , Hiperlipidemias , Neoplasias Hepáticas , Anticorpos Monoclonais/uso terapêutico , Anticolesterolemiantes/uso terapêutico , Carcinoma Hepatocelular/tratamento farmacológico , Colesterol , LDL-Colesterol/metabolismo , Humanos , Inibidores de Hidroximetilglutaril-CoA Redutases/farmacologia , Inibidores de Hidroximetilglutaril-CoA Redutases/uso terapêutico , Hipercolesterolemia/tratamento farmacológico , Hiperlipidemias/tratamento farmacológico , Lipoproteínas , Neoplasias Hepáticas/tratamento farmacológico , Modelos Teóricos , Inibidores de PCSK9 , Pró-Proteína Convertase 9/metabolismo
18.
Adv Mater ; 34(33): e2203958, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35738390

RESUMO

Glioblastoma (GBM) is an intractable malignancy with high recurrence and mortality. Combinatorial therapy based on temozolomide (TMZ) and cisplatin (CDDP) shows promising potential for GBM therapy in clinical trials. However, significant challenges include limited blood-brain-barrier (BBB) penetration, poor targeting of GBM tissue/cells, and systemic side effects, which hinder its efficacy in GBM therapy. To surmount these challenges, new GBM-cell membrane camouflaged and pH-sensitive biomimetic nanoparticles (MNPs) inspired by the fact that cancer cells readily pass the BBB and localize with homologous cells, are developed. This study's results show that MNPs can efficiently co-load TMZ and CDDP, transport these across the BBB to specifically target GBM. Incorporation of pH-sensitive polymer then allows for controlled release of drug cargos at GBM sites for combination drug therapy. Mice bearing orthotopic U87MG or drug-resistant U251R GBM tumor and treated with MNPs@TMZ+CDDP show a potent anti-GBM effect, greatly extending the survival time relative to mice receiving single-drug loaded nanoparticles. No obvious side effects are apparent in histological analyses or blood routine studies. Considering these results, the study's new nanoparticle formulation overcomes multiple challenges currently limiting the efficacy of combined TMZ and CDDP GBM drug therapy and appears to be a promising strategy for future GBM combinatorial chemotherapy.


Assuntos
Neoplasias Encefálicas , Glioblastoma , Animais , Barreira Hematoencefálica/metabolismo , Neoplasias Encefálicas/patologia , Linhagem Celular Tumoral , Cisplatino/farmacologia , Cisplatino/uso terapêutico , Resistencia a Medicamentos Antineoplásicos , Glioblastoma/patologia , Camundongos , Temozolomida/farmacologia , Temozolomida/uso terapêutico , Ensaios Antitumorais Modelo de Xenoenxerto
20.
Soft Matter ; 18(11): 2222-2233, 2022 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-35229856

RESUMO

Cell viability is the primary integrative parameter used for various purposes, particularly when fabricating tissue equivalents (e.g., using bioprinting or scaffolding techniques), optimizing conditions to cultivate cells, testing chemicals, drugs, and biomaterials, etc. Most of the conventional methods were originally designed for a monolayer (2D) culture; however, 2D approaches fail to adequately assess a tissue-engineered construct's viability and drug effects and recapitulate the host-pathogen interactions and infectivity. This study aims at revealing the influence of particular 3D cell systems' parameters such as the components' concentration, gel thickness, cell density, etc. on the cell viability and applicability of standard assays. Here, we present an approach to achieving adequate and reproducible results on the cell viability in 3D collagen- and fibrin-based systems using the Live/Dead, AlamarBlue, and PicoGreen assays. Our results have demonstrated that a routine precise analysis of 3D systems should be performed using a combination of at least three methods based on different cell properties, e.g. the metabolic activity, proliferative capacity, morphology, etc.


Assuntos
Bioimpressão , Materiais Biocompatíveis/farmacologia , Bioimpressão/métodos , Sobrevivência Celular , Impressão Tridimensional , Engenharia Tecidual , Alicerces Teciduais/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA