Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Minerva Anestesiol ; 88(12): 1013-1020, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35833856

RESUMO

BACKGROUND: Patients with liver cirrhosis develop symptoms comparable to those of patients with sepsis, who have increased total vascular compliance, which may cause blood pooling in the venous pool. No previous studies have evaluated the effect of using norepinephrine on the intravascular blood volume. We investigated the norepinephrine infusion's effect on the mean systemic filling pressure, venous return, and cardiac preload in patients undergoing liver transplantation. METHODS: Overall, 33 patients who underwent living donor liver transplantation were included in this study. Cardiac output (CO) was measured using a PiCCO device (Pulsion Medical Systems, Munich, Germany). The mean systemic filling pressure was calculated using the inspiratory hold maneuver at four time intervals - at baseline, 10 min after the norepinephrine infusion, 5 min after norepinephrine discontinuation, and after infusion of 500 cc of 5% albumin. Other hemodynamic parameters, including the mean arterial pressure (MAP), pulse pressure variation, stroke volume variation, global end-diastolic volume, and mitral inflow velocity (E wave), were also evaluated. RESULTS: The norepinephrine infusion increased MAP and systemic vascular resistance in all patients. Moreover, it increased CO, mean systemic filling pressure, and global end-diastolic volume in 20 patients (60%), whereas there were no changes in these variables in 13 patients (40%). In all patients, norepinephrine infusion discontinuation caused a significant decrease in MAP, CO, resistance to venous return, and mean systemic filling pressure. Infusion of 500 cc colloid increased CO; however, interestingly, it was associated with a significant decrease in systemic vascular resistance; hence, MAP and mean systemic filling pressure showed no changes. CONCLUSIONS: The norepinephrine infusion at 0.1 µg-1 kg-1 min-1 was associated with an increase in CO in patients with liver cirrhosis undergoing liver transplantation. Norepinephrine's effect on CO was primarily attributable to an increase in venous return due to an increase in mean systemic filling pressure.


Assuntos
Transplante de Fígado , Norepinefrina , Humanos , Norepinefrina/farmacologia , Norepinefrina/uso terapêutico , Doadores Vivos , Débito Cardíaco , Resistência Vascular , Hemodinâmica , Volume Sanguíneo , Pressão Sanguínea , Cirrose Hepática/cirurgia
2.
J Clin Monit Comput ; 34(2): 271-276, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31004273

RESUMO

Major hemodynamic changes are frequently noted during liver transplantation (LT). We evaluated the performance of electrical velocimetry (EV) as compared to that of TEE in SV optimization during liver transplantation. This was an observational study in 32 patients undergoing LT. We compared SV values measured simultaneously by EV (SVEV) and TEE (SVTEE) at baseline 30 min after induction, at the end of dissection phase, 30 min after anhepatic phase, 30 min after reperfusion. We also evaluated the reliability of EV to track changes In SV before and after 49 fluid challenges. Finally, the SV variation (SVV) and pulse pressure variation (PPV) were tested as predictors for volume responsiveness, defined as an increase in SV ≥ 10% after 250 ml of colloid. For 112 paired SV data, the overall correlation was 0.76 and bias (limits of agreement) 0.3 (- 29 to 29) ml percentage error 62%. The EV was able to track changes in SV with a concordance rate of 97%, and a sensitivity and specificity of 93% to detect a positive fluid challenge. The AUC values (with 95% confidence intervals) for SVV and PPV were 0.68 (0.52-0.83) and 0.72 (0.57-0.86), respectively, indicating low predictive capacity in these setting. The absolute values of SV derived from EV did not agree with SV derived from TEE. However, EV was able to track the direction of changes in SV during hemodynamic management of patients undergoing liver transplantation.Clinical trial registration: Clinicaltrials.gov Identifier: NCT03228329 prospectively Registered on 13-July-2017.


Assuntos
Monitorização Hemodinâmica/métodos , Transplante de Fígado , Monitorização Intraoperatória/métodos , Ressuscitação , Reologia/métodos , Adulto , Cardiografia de Impedância/métodos , Cardiografia de Impedância/estatística & dados numéricos , Ecocardiografia Transesofagiana , Feminino , Hidratação , Monitorização Hemodinâmica/estatística & dados numéricos , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Intraoperatória/estatística & dados numéricos , Estudos Prospectivos , Reologia/estatística & dados numéricos , Volume Sistólico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA