Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Mol Ther Methods Clin Dev ; 31: 101148, 2023 Dec 14.
Artigo em Inglês | MEDLINE | ID: mdl-38046198

RESUMO

Recombinant adeno-associated viruses (rAAVs) are promising gene delivery vectors in the emerging field of in vivo gene therapies. To ensure their consistent quality during manufacturing and process development, multiple analytical techniques have been proposed for the characterization and quantification of rAAV capsids. Despite their indisputable capabilities for performing this task, current analytical methods are rather time-consuming, material intensive, complicated, and costly, restricting their suitability for process development in which time and sample throughput are severe constraints. To eliminate this bottleneck, we introduce here an affinity-based high-performance liquid chromatography method that allows the determination of the capsid titer and the full/empty ratio of rAAVs within less than 5 min. By packing the commercially available AAVX affinity resin into small analytical columns, the rAAV fraction of diverse serotypes can be isolated from process-related impurities and analyzed by UV and fluorescence detection. As demonstrated by both method qualification data and side-by-side comparison with AAV enzyme-linked immunosorbent assay results for rAAV8 samples as well as by experiments using additional rAAV2, rAAV8, and rAAV9 constructs, our approach showed good performance, indicating its potential as a fast, simple and efficient tool for supporting the development of rAAV gene therapies.

2.
Int J Mol Sci ; 24(10)2023 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-37239849

RESUMO

The purity of the three capsid proteins that make up recombinant adeno-associated virus (rAAV) is considered a critical quality attribute of gene therapy products. As such, there is a clear need to develop separation methods capable of rapidly characterizing these three viral proteins (VPs). In this study, the potential benefits and limitations of different electrophoretic and chromatographic methods were evaluated, including capillary electrophoresis-sodium dodecyl sulfate (CE-SDS), reversed phase liquid chromatography (RPLC), hydrophilic interaction chromatography (HILIC), and hydrophobic interaction chromatography (HIC), for the analysis of VPs obtained from different serotypes (i.e., AAV2, AAV5, AAV8, and AAV9). CE-SDS is considered to be the reference method and provides a suitable separation of VP1-3 proteins using generic conditions and laser induced fluorescence detection. However, the characterization of post-translational modifications (i.e., phosphorylation, oxidation) remains difficult, and species identification is almost impossible due to the lack of compatibility between CE-SDS and mass spectrometry (MS). In contrast, RPLC and HILIC were found to be less generic than CE-SDS and require tedious optimization of the gradient conditions for each AAV serotype. However, these two chromatographic approaches are inherently compatible with MS, and were shown to be particularly sensitive in detecting capsid protein variants resulting from different post-translational modifications. Finally, despite being non-denaturing, HIC offers disappointing performance for viral capsid proteins characterization.


Assuntos
Proteínas do Capsídeo , Dependovirus , Proteínas do Capsídeo/genética , Dependovirus/genética , Dependovirus/metabolismo , Cromatografia Líquida , Espectrometria de Massas , Proteínas Virais , Cromatografia de Fase Reversa , Dodecilsulfato de Sódio/química , Eletroforese Capilar/métodos
3.
Int J Mol Sci ; 23(20)2022 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-36293189

RESUMO

Gene therapy is opening unprecedented opportunities for novel therapeutic approaches. Based on the concept of rescuing function mutations by co-expressing the correct gene to allow biological functions to be restored, it requires the use of viral vectors to ensure the proper delivery of therapeutic genes. In this context, recombinant adeno-associated viruses (rAAV) are the most widely used vectors. Their biomanufacturing process requires the insertion of the therapeutic gene into the rAAV (full capsids). However, a percentage of rAAV that do not contain the desired gene (empty capsids), as well as partly filled capsids, might also be produced, potentially impacting the efficiency of the therapy. Therefore, the determination of the rAAV capsids' full/empty ratio needs to be monitored to ensure consistent product quality and efficacy. Anion-exchange chromatography (AEX) can serve this need. In this contribution, thorough AEX method development, including a mobile phase, a stationary phase and gradient conditions, has highlighted its potential in supporting gene therapy. Taking advantage of the fact that viral capsids follow an "on/off" retention behavior, the application of a step gradient approach to the rAAV serotype 8 (rAAV8) allowed the unprecedented separation of rAAV8 full/empty capsids, with a resolution gain of 3.7 as compared to the resolution obtained with a fully optimized linear gradient. Finally, the developed analytical approach allowed a precise and accurate baseline separation and quantification of full and empty rAAV8 capsids, with the potential to be applied as a high-throughput quality control (QC) method.


Assuntos
Capsídeo , Dependovirus , Dependovirus/genética , Capsídeo/química , Terapia Genética , Vetores Genéticos/genética , Cromatografia , Ânions/análise
4.
Eur J Pharm Biopharm ; 152: 318-326, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32445968

RESUMO

Hydrolysis of polysorbate in biopharmaceutical liquid formulations upon long-term storage represents a risk factor, since reduction of the intact surfactant concentration may compromise protein stability. Moreover, accumulation of polysorbate degradation products is associated with the formation of particulates potentially affecting drug product stability and quality. These effects are conventionally assessed by real-time end-of-shelf life studies constituting an integral yet lengthy process of formulation development. To accelerate this procedure, we describe here a powerful tool to conduct shake stress studies based on the controlled hydrolysis of polysorbate 20 by beads-immobilized lipases. For this purpose, the production of stable, partially degraded material characterized by a representative presence of non-emulsifying degradants such as ethoxylated sorbitan and free fatty acids was monitored by state-of-the-art chromatographic methods ensuring realistic pharmaceutical conditions. Freeze-thaw, shaking and shipping stress studies of a mAb formulation did not only demonstrate that this approach is useful to determine the critical degradation level impairing drug product quality, but furthermore revealed significant differences in protective effects depending on the hydrolysis pattern. As these results emphasize, the outlined strategy may support formulation scientists to unveil the interrelationship between polysorbate hydrolysis products and stabilization of the active pharmaceutical ingredient in a holistic and time-saving manner.


Assuntos
Produtos Biológicos/química , Polissorbatos/química , Anticorpos Monoclonais/química , Química Farmacêutica/métodos , Estabilidade de Medicamentos , Ácidos Graxos não Esterificados/química , Hidrólise , Propriedades de Superfície
5.
PLoS One ; 6(3): e17708, 2011 Mar 03.
Artigo em Inglês | MEDLINE | ID: mdl-21390239

RESUMO

Amino acid oxidation is known to affect the structure, activity, and rate of degradation of proteins. Methionine oxidation is one of the several chemical degradation pathways for recombinant antibodies. In this study, we have identified for the first time a solvent accessible tryptophan residue (Trp-32) in the complementary-determining region (CDR) of a recombinant IgG1 antibody susceptible to oxidation under real-time storage and elevated temperature conditions. The degree of light chain Trp-32 oxidation was found to be higher than the oxidation level of the conserved heavy chain Met-429 and the heavy chain Met-107 of the recombinant IgG1 antibody HER2, which have already been identified as being solvent accessible and sensitive to chemical oxidation. In order to reduce the time for simultaneous identification and functional evaluation of potential methionine and tryptophan oxidation sites, a test system employing tert-butylhydroperoxide (TBHP) and quantitative LC-MS was developed. The optimized oxidizing conditions allowed us to specifically oxidize the solvent accessible methionine and tryptophan residues that displayed significant oxidation in the real-time stability and elevated temperature study. The achieved degree of tryptophan oxidation was adequate to identify the functional consequence of the tryptophan oxidation by binding studies. In summary, the here presented approach of employing TBHP as oxidizing reagent combined with quantitative LC-MS and binding studies greatly facilitates the efficient identification and functional evaluation of methionine and tryptophan oxidation sites in the CDR of recombinant antibodies.


Assuntos
Anticorpos/metabolismo , Espectrometria de Massas , Proteínas Recombinantes/metabolismo , Triptofano/metabolismo , terc-Butil Hidroperóxido/farmacologia , Sequência de Aminoácidos , Anticorpos/química , Cromatografia Líquida , Metionina/metabolismo , Dados de Sequência Molecular , Oxirredução/efeitos dos fármacos , Proteínas Recombinantes/química , Padrões de Referência , Ressonância de Plasmônio de Superfície , Raios Ultravioleta
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA