1.
Molecules ; 28(3)2023 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-36770850

RESUMO

A capillary zone electrophoretic (CZE) method was developed, validated, and applied for the assay of metformin (MET) and pioglitazone (PIO) in pharmaceutical formulations. The optimum running buffer composition was found to be 75 mmol/L phosphate buffer containing 30% acetonitrile (ACN) at pH 4.0. The optimum instrumental conditions were found to be injection time, 10 s; applied voltage, 25 kV; hydrodynamic injection pressure, 0.5 psi for 10 s, capillary temperature, 25 °C; and the detection wavelength, 210 nm. The quantifications were calculated based on the ratio of the peak areas of analytes to atenolol as an internal standard. The CZE method was validated in terms of accuracy (98.21-104.81%), intra- and inter-day precision of migration time and peak area (relative standard deviation ≤ 5%), linearity (correlation coefficients ≥ 0.9985), limit of detection (≤0.277 µg/mL), and limit of quantitation (≤0.315 µg/mL). The proposed method was applied for the analysis of PIO and MET both individually and in a combined dosage tablet formulation. All electrophoretic parameters were calculated and evaluated. A previously reported high-performance liquid chromatographic (HPLC) method was also applied to the same samples. A comprehensive comparison was then carried out for the analytical features of both methods CZE and HPLC. Comparable results were obtained with the advantage of reagent consumption and separation efficiency of CZE over HPLC and shorter analysis time by HPLC compared with CZE.


Assuntos
Metformina , Pioglitazona , Cromatografia Líquida de Alta Pressão/métodos , Eletroforese Capilar/métodos , Comprimidos , Indicadores e Reagentes , Reprodutibilidade dos Testes
2.
Crit Rev Anal Chem ; 52(3): 535-543, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-32835492

RESUMO

Capacitively coupled contactless conductivity detection (C4D) has emerged as influential to detect analytes that do not have chromogenic or fluorogenic functional group. Since our last review several new capillary electrophoresis (CE) methods coupled with (CE-C4D) have been communicated. The aim of this review is to give an update of the almost all the new applications of CE-C4D in the field of pharmaceutical, food and biomedical analysis covering the period from 2017 to April 2020. The utilization of CE with C4D in the areas of pharmaceutical, food and biomedical analysis is presented. Finally, concluding remarks and outlooks are discussed.


Assuntos
Eletroforese Capilar , Condutividade Elétrica , Eletroforese Capilar/métodos , Preparações Farmacêuticas
3.
Arab J Chem ; 15(3): 103631, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34909055

RESUMO

One of the proven methods to prevent and inhibit viral infections is to use antibodies to block the initial Receptor Binding Domain (RBD) of SARS-CoV-2 S protein and avoid its binding with the host cells. Thus, developing these RBD-targeting antibodies would be a promising approach for treating the SARS-CoV-2 infectious disease and stop virus replication. Macrocyclic epitopes constitute closer mimics of the receptor's actual topology and, as such, are expected to be superior epitopes for antibody generation. This work demonstrated the vital effect of the three-dimensional shape of epitopes on the developed antibodies' activity against RBD protein of SARS-CoV-2. The molecular dynamics studies showed the greater stability of the cyclic epitopes in comparison with the linear counterpart, which was reflected in the activity of their produced antibodies. Indeed, the antibodies we developed using macrocyclic epitopes showed superiority with respect to binding to RBD proteins compared to antibodies formed from a linear peptide. The results of the present work constitute a roadmap for developing superior antibodies that could be used to inhibit the activity of the SARS-CoV-2 and prevent its reproduction.

4.
ACS Omega ; 6(47): 31469-31476, 2021 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-34869973

RESUMO

Efficient COVID-19 vaccines are widely acknowledged as the best way to end the global pandemic. SARS-CoV-2 receptor-binding domain (RBD) plays fundamental roles related to cell infection. Antibodies could be developed to target RBD and represent a potential approach for the neutralization of the virus. Epitopes used to produce antibodies are generally linear peptides and thus possess multiple confirmations that do not reflect the actual topology of the targeted part in the native protein. On the other hand, macrocyclic epitopes could constitute closer mimics of the native protein topology and, as such, could generate superior antibodies. In this study, we demonstrated the vital effect of the size and the three-dimensional shape of epitopes on the activity of the developed antibodies against the RBD of SARS-CoV-2. The molecular dynamics studies showed the greater stability of the cyclic epitopes compared with the linear counterparts, which was reflected in the affinity of the produced antibodies. The antibodies developed using macrocyclic epitopes showed superiority with respect to binding to RBD compared to antibodies formed from linear peptides. This study constitutes a roadmap for developing superior antibodies that could be used to inhibit the activity of SARS-CoV-2.

5.
Molecules ; 26(20)2021 Oct 12.
Artigo em Inglês | MEDLINE | ID: mdl-34684741

RESUMO

Three rapid, accurate, and ecofriendly processed spectrophotometric methods were validated for the concurrent quantification of remogliflozin (RGE) and vildagliptin (VGN) from formulations using water as dilution solvent. The three methods developed were based on the calculation of the peak height of the first derivative absorption spectra at zero-crossing points, the peak amplitude difference at selected wavelengths of the peak and valley of the ratio spectra, and the peak height of the ratio first derivative spectra. All three methods were validated adapting the ICH regulations. Both the analytes showed a worthy linearity in the concentration of 1 to 60 µg/mL and 2 to 90 µg/mL for VGN and RGE, respectively, with an exceptional regression coefficient (r2 ≥ 0.999). The developed methods demonstrated an excellent recovery (98.00% to 102%), a lower percent relative standard deviation, and a relative error (less than ±2%), confirming the specificity, precision, and accuracy of the proposed methods. In addition, validated spectrophotometric methods were commendably employed for the simultaneous determination of VGN and RGE from solutions prepared in the laboratory and the formulation. Hence, these methods can be utilized for the routine quality control study of the pharmaceutical preparations of VGN and RGE in pharmaceutical industries and laboratories. The ecofriendly nature of the anticipated spectrophotometric procedures was confirmed by the evaluation of the greenness profile by a semi-quantitative method and the quantitative and qualitative green analytical procedure index (GAPI) method.


Assuntos
Glucosídeos/análise , Pirazóis/análise , Espectrofotometria/métodos , Vildagliptina/análise , Glucosídeos/isolamento & purificação , Pirazóis/isolamento & purificação , Solventes , Espectrofotometria Ultravioleta/métodos , Vildagliptina/isolamento & purificação
6.
J AOAC Int ; 96(2): 282-9, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23767351

RESUMO

Sequential injection chromatography (SIC) is a recent, simple, and inexpensive green miniaturized separation technique. In the current study, SIC was exploited for the first time for biochemical analysis. A new SIC method for the separation and quantification of chlorpromazine in human urine, as well as pharmaceutical formulations, was developed and validated. Clozapine was used as an internal standard. Chlorpromazine was successfully separated on a C18 monolithic column (25x4.6 mm id). The UV detection was carried out at 250 nm using miniaturized fiber optic spectrometric devices. The optimum mobile phase composition was 30 mmol/L phosphate-acetonitrile-methanol (55.0 + 31.5 + 13.5, v/v/v) at pH 3.0. The sample volume was 40 microL and flow rate was 40 microL/s. Acceptable chromatographic results were obtained. The resolution was 2.7, peak symmetry was 1.1, and number of theoretical plates was more than 1 x 10(6). Good linearity (r = 0.9997) in the range of 25-100 microg/mL was also obtained. The method offered acceptable recovery for both human urine (89.6-93.1%) and pharmaceutical formulations (96.9-98.5%), which was sensitive enough to detect chlorpromazine. The LOD and LOQ in human urine were 61 and 204 ng/mL, respectively. The method was rapid and reagent-saving, and hence safe for the environment. The sample throughput was 26.3 samples/h and the total volume of consumed reagents was 4.0 mL.


Assuntos
Antipsicóticos/química , Antipsicóticos/urina , Clorpromazina/química , Clorpromazina/urina , Cromatografia/métodos , Clozapina/química , Clozapina/urina , Humanos , Estrutura Molecular , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
7.
J Chromatogr Sci ; 51(1): 92-7, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22752183

RESUMO

The current manuscript reports the first capillary electrophoresis method for the separation and quantification of metoprolol (MET) and hydrochlorothiazide (HCT) in their combined dosage form. MET and HCT were detected at 240 and 214 nm, respectively, using a photodiode array detector. The univariate approach was used for optimizing voltage, injection time and capillary temperature. The factorial design with response surface plots, as a multivariate approach, was used to study the effect of buffer concentration and pH on resolution, peak area and migration time. The optimum conditions were 50 mmol/L phosphate at pH 9.5, injection time 10.0 s, voltage 25 kV and capillary temperature 25°C. The method was linear in the range of 2.5-250 µg/mL for both drugs with correlation coefficients above 0.9997. Additionally, acceptable recovery of the contents of MET and HCT in their formulations (96.0-100.3%) with acceptable precision (1.38-2.60 %) were achieved. Moreover, the limits of detection of MET and HCT were 0.02 and 0.01 µg/mL, respectively, which were suitable for pharmaceutical analysis.


Assuntos
Eletroforese Capilar/métodos , Hidroclorotiazida/análise , Metoprolol/análise , Combinação de Medicamentos , Hidroclorotiazida/química , Hidroclorotiazida/isolamento & purificação , Limite de Detecção , Metoprolol/química , Metoprolol/isolamento & purificação , Análise Multivariada , Reprodutibilidade dos Testes , Comprimidos/química
8.
Chem Cent J ; 5: 28, 2011 Jun 09.
Artigo em Inglês | MEDLINE | ID: mdl-21658210

RESUMO

BACKGROUND: Sequential injection chromatography (SIC) is a new alternative separation technology. It has some advantages over high performance liquid chromatography (HPLC) regarding simplicity, inexpensiveness, portability, ease of use, maintenance requirement and operation time. In contrast, SIC has had suffered from some limitations. RESULTS: The current work involves four achievements. (a) One of the limitations of SIC has been overcome. A higher pressure resistant selection valve with additional ports was installed in an SIC system. This development allows propelling solution without showing solution leakage. (b) A new inexpensive rapid and green method for the separation and quantification of propranolol (PRP) and hydrochlorothiazide (HTZ) in their formulations was optimized and validated. (c) A miniaturized multi-channel fiber optic detector was coupled with the newly developed SIC system to detect PRP and HTZ at 270 and 290 nm, respectively. This issue enhanced the sensitivity rather than using a single-channel detector. (d) A comparative study on the efficiency of the SIC method with that of previous HPLC methods was conducted. CONCLUSIONS: Besides the benefits of the instrumentation of SIC, the proposed method is rapider and more reagent-saving than previous HPLC methods. The total volume of consumed reagents and sample was 4.04 mL. The sample frequency was 22 samples/h. Other such analytical characters of the SIC method as resolution, peak symmetry, numbers of theoretical plates, linearity range, accuracy, precision and limits of detection and quantification recorded comparable results.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA