Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
1.
Eur Heart J Cardiovasc Pharmacother ; 10(3): 184-189, 2024 May 04.
Artigo em Inglês | MEDLINE | ID: mdl-38216511

RESUMO

INTRODUCTION: Atrial arrhythmia is the most common complication of patent foramen ovale (PFO) closure. The real incidence of post-PFO closure atrial arrhytmia and whether this complication can be prevented is unknown. METHODS/DESIGN: The Assessment of Flecainide to Lower the PFO closure risk of Atrial fibrillation or Tachycardia (AFLOAT) trial is a prospective, national, multicentre, randomized, open-label, superiority trial with a blind evaluation of all the endpoints (PROBE design). A total of 186 patients are randomized in a 1:1:1 ratio immediately after PFO closure to receive Flecainide (150 mg per day in a single sustained-release (SR) dose) for 6 months (Group 1), Flecainide (150 mg per day in a single SR dose) for 3 months (Group 2), or no additional treatment (standard of care) for 6 months (Group 3). The primary endpoint is the percentage of patients with at least one episode of symptomatic or asymptomatic atrial arrhythmia episode (≥30 s) recorded within 3 months after PFO closure on long-term monitoring with an insertable cardiac monitor. Whether 3 months of treatment is sufficient compared to 6 months will be analysed as a secondary objective of the study. CONCLUSION: AFLOAT is the first trial to test the hypothesis that a short treatment with oral Flecainide can prevent the new-onset of atrial arrhythmia after PFO closure. CLINICAL TRIAL REGISTRATION: NCT05213104 (clinicaltrials.gov).


Assuntos
Antiarrítmicos , Fibrilação Atrial , Flecainida , Forame Oval Patente , Humanos , Flecainida/efeitos adversos , Flecainida/administração & dosagem , Flecainida/uso terapêutico , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/prevenção & controle , Estudos Prospectivos , Antiarrítmicos/uso terapêutico , Antiarrítmicos/efeitos adversos , Antiarrítmicos/administração & dosagem , Resultado do Tratamento , Forame Oval Patente/complicações , Forame Oval Patente/terapia , Feminino , Masculino , Fatores de Tempo , Adulto , Pessoa de Meia-Idade , Frequência Cardíaca/efeitos dos fármacos
2.
Catheter Cardiovasc Interv ; 102(5): 864-877, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37668012

RESUMO

BACKGROUND: The recent development and widespread adoption of antegrade dissection re-entry (ADR) techniques have been underlined as one of the antegrade strategies in all worldwide CTO consensus documents. However, historical wire-based ADR experience has suffered from disappointing long-term outcomes. AIMS: Compare technical success, procedural success, and long-term outcome of patients who underwent wire-based ADR technique versus antegrade wiring (AW). METHODS: One thousand seven hundred and ten patients, from the prospective European Registry of Chronic Total Occlusions (ERCTO), underwent 1806 CTO procedures between January 2018 and December 2021, at 13 high-volume ADR centers. Among all 1806 lesions attempted by the antegrade approach, 72% were approached with AW techniques and 28% with wire-based ADR techniques. RESULTS: Technical and procedural success rates were lower in wire-based ADR than in AW (90.3% vs. 96.4%, p < 0.001; 87.7% vs. 95.4%, p < 0.001, respectively); however, wire-based ADR was used successfully more often in complex lesions as compared to AW (p = 0.017). Wire-based ADR was used in most cases (85%) after failure of AW or retrograde procedures. At a mean clinical follow-up of 21 ± 15 months, major adverse cardiac and cerebrovascular events (MACCEs) did not differ between AW and wire-based ADR (12% vs. 15.1%, p = 0.106); both AW and wire-based ADR procedures were associated with significant symptom improvements. CONCLUSIONS: As compared to AW, wire-based ADR is a reliable and effective strategy successfully used in more complex lesions and often after the failure of other techniques. At long-term follow-up, patient's MACCEs and symptoms improvement were similar in both antegrade techniques.


Assuntos
Oclusão Coronária , Intervenção Coronária Percutânea , Humanos , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/terapia , Resultado do Tratamento , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/métodos , Estudos Prospectivos , Angiografia Coronária , Sistema de Registros , Doença Crônica
3.
J Am Heart Assoc ; 12(17): e030037, 2023 09 05.
Artigo em Inglês | MEDLINE | ID: mdl-37609989

RESUMO

Background The interrelationships between left atrial appendage (LAA) dimensions and device following implantation are unknown. We aimed to analyze the impact of Watchman device implantation on LAA dimensions following its percutaneous closure and potential predictors of remodeling. Methods and Results All consecutive LAA closure procedures performed at 2 centers between November 2017 and December 2020 were included in the WATCH-DUAL (Watchman 2.5 Versus Watchman FLX in a Dual-Center Left Atrial Appendage Closure Cohort) registry. This study included patients who had pre- and postintervention computed tomography scan analysis. The LAA and device dimensions were measured in a centralized core lab by 3-dimensional computed tomography scan reconstruction methods, focusing on the device landing zone. This analysis included 104 patients (age, 76.0 [range, 72.0-83.0] years; 72% men; 53% Watchman FLX; 47% Watchman 2.5). The baseline characteristics were comparable between Watchman 2.5 and Watchman FLX groups, except for the higher use of oversizing in the latter group. The median delay for computed tomography control was 49 (range, 43-64) days. The landing zone area (median, 446 [range, 363-523] versus 290 [222-366] mm2; P<0.001) and minimal diameter (median, 23.0 [range, 20.7-24.8] versus 16.7 [14.7-19.4] mm; P<0.001) significantly increased after implantation. The absolute (median, 157 [range, 98-220] versus 85 [18-148] mm2, P<0.001) and relative (median, 50% [range, 32%-79%] versus 26% [4%-50%]; P<0.001) increases in landing zone area were more pronounced in patients with oversized device. Baseline LAA dimensions were smaller, landing zone eccentricity larger, and oversized device more frequent in patients with significant overexpansion compared with the others. Conclusions LAA dimensions increased at the site of the Watchman prosthesis after implantation, suggesting a local positive remodeling after the procedure. This phenomenon was more pronounced in the case of oversized devices.


Assuntos
Apêndice Atrial , Remodelamento Atrial , Masculino , Humanos , Idoso , Feminino , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Implantação de Prótese , Sistema de Registros , Tomografia Computadorizada por Raios X
4.
Arch Cardiovasc Dis ; 115(10): 505-513, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36123284

RESUMO

BACKGROUND: Randomized trials comparing the first-generation absorb bioresorbable vascular scaffold (BVS) (Abbott Vascular, Santa Clara, CA, USA) with a drug-eluting stent showed a moderate but significant increase in the rate of 3-year major adverse cardiac events and scaffold thrombosis, followed by a decrease in adverse events after 3 years. AIM: The objective of this study was to assess the 5-year outcomes of patients treated with at least one absorb BVS and included in the FRANCE ABSORB registry. METHODS: All patients treated in France with an absorb BVS were prospectively included in a large nationwide multicentre registry. The primary efficacy outcome was the occurrence of 5-year major adverse cardiac events. Secondary efficacy outcomes were the rates of 5-year target vessel revascularization and definite/probable scaffold thrombosis. RESULTS: Between September 2014 and April 2016, 2,070 patients were included in 86 centres (mean age 55±11 years; 80% men; 49% with acute coronary syndrome). The rates of 1-, 3- and 5-year major adverse cardiac events were 3.9%, 9.4% and 12.1%, respectively (including cardiac death in 2.5% and target vessel revascularization in 10.4%). By multivariable analysis, diabetes, oral anticoagulation, the use of multiple Absorb BVSs and the use of a 2.5mm diameter absorb BVS were associated with 5-year major adverse cardiac events. The rates of 1-, 3- and 5-year definite/probable scaffold thrombosis were 1.5%, 3.1% and 3.6%, respectively. By multivariable analysis, older age, diabetes, anticoagulation at discharge and the use of a 2.5mm diameter absorb BVS were associated with 5-year scaffold thrombosis. CONCLUSIONS: Absorb BVS implantation was associated with low rates of 1-year major adverse cardiac events, which increased significantly at 3-year follow-up. There was a clear decrease in the rates of scaffold thrombosis and major adverse cardiac events after 3 years.


Assuntos
Doença da Artéria Coronariana , Diabetes Mellitus , Stents Farmacológicos , Intervenção Coronária Percutânea , Masculino , Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Feminino , Implantes Absorvíveis , Everolimo , Resultado do Tratamento , Desenho de Prótese , Fatores de Tempo , Sistema de Registros , Anticoagulantes , Intervenção Coronária Percutânea/efeitos adversos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia
5.
Europace ; 24(9): 1441-1450, 2022 10 13.
Artigo em Inglês | MEDLINE | ID: mdl-35253840

RESUMO

AIMS: No studies have compared Watchman 2.5 (W2.5) with Watchman FLX (FLX) devices to date. We aimed at comparing the FLX with W2.5 devices with respect to clinical outcomes, left atrial appendage (LAA) sealing properties and device-related thrombus (DRT). METHODS AND RESULTS: All consecutive left atrial appendage closure (LAAC) procedures performed at two European centres between November 2017 and February 2021 were included. Procedure-related complications and net adverse cardiovascular events (NACE) at 6 months after LAAC were recorded. At 45-day computed tomography (CT) follow-up, intra- (IDL) and peri- (PDL) device leak, residual patent neck area (RPNA), and DRT were assessed by a Corelab. Out of 144 LAAC consecutive procedures, 71 and 73 interventions were performed using W2.5 and FLX devices, respectively. There were no differences in terms of procedure-related complications (4.2% vs. 2.7%, P = 0.626). At 45-day CT, the FLX was associated with lower frequency of IDL [21.3% vs. 40.0%; P = 0.032; odds ratio (OR): 0.375; 95% confidence interval (CI): 0.160-0.876; P = 0.024], similar rate of PDL (29.5% vs. 42.0%; P = 0.170), and smaller RPNA [6 (0-36) vs. 40 (6-115) mm2; P = 0.001; OR: 0.240; 95% CI: 0.100-0.577; P = 0.001] compared with the W2.5 group. At 45 days, rate of DRT as detected by CT and/or transoesophageal echocardiography (TOE), was higher with W2.5 (6.0% vs. 0%, P = 0.045). At 6-month follow-up, NACE did not differ between groups. CONCLUSIONS: In this cohort of consecutive LAACs, FLX as compared to W2.5, was associated with similar procedure-related complications and 6-month NACE, but with improved LAA neck coverage, and lower IDL and DRT.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Dispositivo para Oclusão Septal , Acidente Vascular Cerebral , Trombose , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Cateterismo Cardíaco/efeitos adversos , Ecocardiografia Transesofagiana , Humanos , Dispositivo para Oclusão Septal/efeitos adversos , Acidente Vascular Cerebral/complicações , Acidente Vascular Cerebral/prevenção & controle , Trombose/etiologia , Trombose/prevenção & controle , Resultado do Tratamento
6.
Catheter Cardiovasc Interv ; 98(3): 511-519, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33211387

RESUMO

OBJECTIVES: The aim of this study was to determine the 3-year outcomes of patients treated with Absorb bioresorbable vascular scaffold (BVS) implantation. BACKGROUND: Randomized trials and observational registries performed in patients undergoing percutaneous coronary intervention have demonstrated higher 1-year and midterm rates of device thrombosis and adverse events with BVS compared to contemporary drug eluting stent. Data on long-term follow-up of patients treated with BVS are scarce. METHODS: All patients treated with BVS were included in a large nationwide prospective multicenter registry (FRANCE ABSORB). The primary endpoint was a composite of cardiovascular death, myocardial infarction, and target lesion revascularization at 3 years. Secondary endpoints were 3-year scaffold thrombosis and target vessel revascularization (TVR). RESULTS: Between September 2014 and April 2016, 2070 patients were included (mean age 55 ± 11 years; 80% men). The indication was acute coronary syndrome (ACS) in 49% of patients. At 3 years, the primary endpoint occurred in 184 patients (8.9%) and 3-year mortality in 43 patients (2.1%). Scaffold thrombosis and TVR rates through 3 years were, respectively, 3 and 7.6%. In a multivariable analysis, independent predictors of primary endpoint occurrence were diabetes, oral anticoagulation, active smoking, absence of initial angiographic success and the association of a total BVS length ≥30 mm with the use of 2.5 mm diameter BVS. CONCLUSIONS: Although 3-year mortality was low in this ACS population, device-related events were significant beyond 1 year. Total BVS length and 2.5 mm BVS were associated with higher rates of MACE at long-term follow-up.


Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Intervenção Coronária Percutânea , Implantes Absorvíveis , Adulto , Idoso , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Everolimo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Estudos Prospectivos , Desenho de Prótese , Sistema de Registros , Resultado do Tratamento
7.
Int J Cardiol ; 307: 1-7, 2020 05 15.
Artigo em Inglês | MEDLINE | ID: mdl-32093952

RESUMO

OBJECTIVE: Regional and global longitudinal strain (RLS-GLS) are considered reliable indexes of myocardial viability in chronic ischemic patients and prediction of left ventricular (LV) functional recovery after acute myocardial infarction (MI) with preserved left ventricular ejection fraction (LVEF). We tested in the present study whether RLS and GLS could also identify transmural extent of myocardial scar and predict LV functional recovery and remodeling in patients with reduced LVEF after acute MI. METHODS: Echocardiography and late gadolinium enhancement cardiac magnetic resonance (LGE-CMR) were performed in 71 patients with reduced LVEF (≤45%) after acute MI treated with acute percutaneous coronary intervention. At 8-month follow-up, echocardiography was repeated to determine global LV functional recovery and remodeling. RESULTS: RLS was worse in transmural than in non-transmural infarcted segments (-6.6 ± 6.1% vs -10.3 ± 5.9%, p < 0.0001) and in non-transmural than in normal segments (-10.3 ± 5.9% vs -14.5 ± 6.4%, p < 0.0001). RLS > -12% had sensitivity of 78% and specificity of 69% to identify transmural infarcted segments (AUC = 0.79; 95% CI, 0.77-0.81, p < 0.0001). GLS > -11.3% had sensitivity of 53% and specificity of 100% to predict the absence of LV global functional improvement (AUC = 0.73, CI, 0.55-0.87, p = 0.01) at 8-month follow-up. GLS < -12.5% predicted the absence of adverse LV remodeling with sensitivity of 100% and specificity of 54% (AUC = 0.83; CI, 0.66-0.94, p < 0.0001). GLS > -11.5% was associated with a poor prognosis. CONCLUSIONS: In patients with reduced LVEF after acute MI, RLS and GLS allow: (1) identification of transmural extent of myocardial scar and (2) predict LV global functional recovery and remodeling at 8-month follow-up.


Assuntos
Infarto do Miocárdio , Disfunção Ventricular Esquerda , Meios de Contraste , Gadolínio , Humanos , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/terapia , Volume Sistólico , Disfunção Ventricular Esquerda/diagnóstico por imagem , Função Ventricular Esquerda
8.
Int J Cardiol ; 307: 24-30, 2020 05 15.
Artigo em Inglês | MEDLINE | ID: mdl-31668659

RESUMO

BACKGROUND: Left atrial appendage occlusion (LAAO) has emerged as a valid alternative to oral anticoagulation therapy for the prevention of systemic embolism in patients with non-valvular atrial fibrillation (NVAF). Microvesicles (MVs) are shed-membrane particles generated during various cellular types activation/apoptosis that carry out diverse biological effects. LAA has been suspected to be a potential source of MVs during AF, but the effects its occlusion on circulating MVs levels are unknown. METHODS: N = 25 LAAO and n = 25 control patients who underwent coronary angiography were included. Blood samples were drawn before and 48 h after procedure for all. A third sample was collected 6 weeks after procedure in LAAO patients. In N = 10 extra patients, samples were collected from right atrium, LAA and pulmonary vein during LAAO procedure. Circulating AnnV + procoagulant, endothelial, platelets, red blood cells/RBC and leukocytes derived-MVs were measured using flow cytometry methods. RESULTS: In the LAAO group, AnnV+, platelets, RBC, and leukocytes MVs were significantly increased following intervention, whereas only AnnV + MVs levels significantly rose in controls. The 6-w analysis showed that RBC-MVs and AnnV + MVs levels were still significantly elevated compared to baseline values in LAAO patients. The in-site analysis revealed that leukocytes and CD62e + endothelial-MVs were significantly higher in left atrial appendage compared to pulmonary vein, suggesting a local increased production. No major adverse event was observed in any patient post procedural course. CONCLUSIONS: LAAO impacts circulating MVs and might create mild pro-coagulant status and potential erythrocytes activation due to the device healing during the first weeks following intervention.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Procedimentos Cirúrgicos Cardíacos , Dispositivo para Oclusão Septal , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Humanos , Resultado do Tratamento
9.
Circ Cardiovasc Interv ; 12(11): e007749, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31694410

RESUMO

BACKGROUND: In the ARCTIC trial (Assessment by a Double Randomization of a Conventional Antiplatelet Strategy Versus a Monitoring-Guided Strategy for Drug-Eluting Stent Implantation and of Treatment Interruption Versus Continuation One Year After Stenting), treatment adjustment following platelet function testing failed to improve clinical outcomes. However, high-on-treatment platelet reactivity (HPR) is considered as a predictor of poor ischemic outcome. This prespecified substudy evaluated clinical outcomes according to the residual platelet reactivity status after antiplatelet therapy adjustment. METHODS: We analyzed the 1213 patients assigned to the monitoring arm of the ARCTIC trial in whom platelet reactivity was evaluated by the VerifyNow P2Y12 test before percutaneous coronary intervention and during the maintenance phase (at 14 days). HPR was defined as platelet reaction unit≥235U. The primary ischemic end point, a composite of death, myocardial infarction, stent thrombosis, stroke, or urgent revascularization and the safety end point of major bleeding were assessed according to the platelet reactivity status. RESULTS: Before percutaneous coronary intervention, 35.7% of patients displayed HPR (n=419). During the acute phase, between percutaneous coronary intervention and the 14-day platelet function testing, ischemic (adjusted hazard ratio, 0.94 [95% CI, 0.74-1.18]; P=0.58) and safety outcomes (hazard ratio, 1.28 [95% CI, 0.22-7.59]; P=0.78) were similar in HPR and non-HPR patients. During the maintenance phase, the proportion of HPR patients (n=186, 17.4%) decreased by 56%. At 1-year, there was no difference for the ischemic end point (5.9% versus 6.0%; adjusted hazard ratio, 0.79 [95% CI, 0.40-1.58]; P=0.51) and a nonsignificant higher rate of major bleedings (2.7% versus 1.0%, hazard ratio, 2.83 [95% CI, 0.96-8.41]; P=0.06) in HPR versus non-HPR patients. CONCLUSIONS: The proportion of HPR was halved after platelet function testing and treatment adjustment but without significant ischemic benefit at 1 year. HPR seems more as a modifiable risk marker than a risk factor of ischemic outcome. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov. Unique identifier: NCT00827411.


Assuntos
Plaquetas/efeitos dos fármacos , Monitoramento de Medicamentos/métodos , Intervenção Coronária Percutânea , Ativação Plaquetária/efeitos dos fármacos , Inibidores da Agregação Plaquetária/administração & dosagem , Testes de Função Plaquetária , Antagonistas do Receptor Purinérgico P2Y/administração & dosagem , Receptores Purinérgicos P2Y12/efeitos dos fármacos , Idoso , Plaquetas/metabolismo , Tomada de Decisão Clínica , Trombose Coronária/sangue , Trombose Coronária/etiologia , Trombose Coronária/prevenção & controle , Stents Farmacológicos , Feminino , Hemorragia/induzido quimicamente , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/sangue , Infarto do Miocárdio/etiologia , Infarto do Miocárdio/prevenção & controle , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/instrumentação , Intervenção Coronária Percutânea/mortalidade , Inibidores da Agregação Plaquetária/efeitos adversos , Valor Preditivo dos Testes , Antagonistas do Receptor Purinérgico P2Y/efeitos adversos , Receptores Purinérgicos P2Y12/sangue , Medição de Risco , Fatores de Risco , Acidente Vascular Cerebral/sangue , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Fatores de Tempo , Resultado do Tratamento
10.
JACC Cardiovasc Interv ; 12(4): 335-342, 2019 02 25.
Artigo em Inglês | MEDLINE | ID: mdl-30711551

RESUMO

OBJECTIVES: The aim was to establish a contemporary scoring system to predict the outcome of chronic total occlusion coronary angioplasty. BACKGROUND: Interventional treatment of chronic total coronary occlusions (CTOs) is a developing subspecialty. Predictors of technical success or failure have been derived from datasets of modest size. A robust scoring tool could facilitate case selection and inform decision making. METHODS: The study analyzed data from the EuroCTO registry. This prospective database was set up in 2008 and includes >20,000 cases submitted by CTO expert operators (>50 cases/year). Derivation (n = 14,882) and validation (n = 5,745) datasets were created to develop a risk score for predicting technical failure. RESULTS: There were 14,882 patients in the derivation dataset (with 2,356 [15.5%] failures) and 5,745 in the validation dataset (with 703 [12.2%] failures). A total of 20.2% of cases were done retrogradely, and dissection re-entry was performed in 9.3% of cases. We identified 6 predictors of technical failure, collectively forming the CASTLE score (Coronary artery bypass graft history, Age (≥70 years), Stump anatomy [blunt or invisible], Tortuosity degree [severe or unseen], Length of occlusion [≥20 mm], and Extent of calcification [severe]). When each parameter was assigned a value of 1, technical failure was seen to increase from 8% with a CASTLE score of 0 to 1, to 35% with a score ≥4. The area under the curve (AUC) was similar in both the derivation (AUC: 0.66) and validation (AUC: 0.68) datasets. CONCLUSIONS: The EuroCTO (CASTLE) score is derived from the largest database of CTO cases to date and offers a useful tool for predicting procedural outcome.


Assuntos
Oclusão Coronária/terapia , Técnicas de Apoio para a Decisão , Intervenção Coronária Percutânea/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Doença Crônica , Oclusão Coronária/diagnóstico por imagem , Bases de Dados Factuais , Europa (Continente) , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Sistema de Registros , Reprodutibilidade dos Testes , Medição de Risco , Fatores de Risco , Falha de Tratamento
11.
Arch Cardiovasc Dis ; 112(2): 113-123, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30630761

RESUMO

BACKGROUND: Several randomized studies have shown that bioresorbable vascular scaffold (BVS) technology is associated with an increased risk of stent thrombosis. AIM: This study aimed to assess the rates of adverse outcomes at 1 year in patients treated with the Absorb BVS (Abbott Vascular, Santa Clara, CA, USA), using data from a large nationwide prospective multicentre registry (FRANCE ABSORB). METHODS: All patients receiving the Absorb BVS in France were included prospectively in the study. Predilatation, optimal sizing and postdilatation were recommended systematically. The primary endpoint was a composite of cardiovascular death, myocardial infarction and target lesion revascularization at 1 year. Secondary endpoints were scaffold thrombosis and target vessel revascularization at 1 year. RESULTS: A total of 2072 patients at 86 centres were included: mean age 55±11 years; 80% men. The indication was acute coronary syndrome (ACS) in 49% of cases. Predilatation and postdilatation were done in 93% and 83% of lesions, respectively. At 1 year, the primary endpoint occurred in 3.9% of patients, the rate of scaffold thrombosis was 1.5% and the rate of target vessel revascularization was 3.3%. In a multivariable analysis, diabetes and total Absorb BVS length>30mm were independently associated with the occurrence of the primary endpoint, whereas oral anticoagulation and total Absorb BVS length>30mm were independently associated with occurrence of scaffold thrombosis. CONCLUSIONS: The Absorb BVS was implanted in a relatively young population, half of whom had ACS. Predilatation and postdilatation rates were high, and 1-year outcomes were acceptable.


Assuntos
Implantes Absorvíveis , Síndrome Coronariana Aguda/cirurgia , Angina Instável/cirurgia , Angioplastia Coronária com Balão/instrumentação , Infarto do Miocárdio/cirurgia , Síndrome Coronariana Aguda/diagnóstico por imagem , Síndrome Coronariana Aguda/mortalidade , Adulto , Idoso , Angina Instável/diagnóstico por imagem , Angina Instável/mortalidade , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/mortalidade , Trombose Coronária/etiologia , Feminino , França , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/mortalidade , Estudos Prospectivos , Desenho de Prótese , Recidiva , Sistema de Registros , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
12.
Circ Cardiovasc Interv ; 11(10): e006229, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-30354635

RESUMO

BACKGROUND: The study focuses on the evolution of practice, procedural outcomes, and in-hospital complications of chronic total occlusion percutaneous coronary intervention in Europe. METHODS AND RESULTS: Data from 17 626 procedures enrolled in European Registry of Chronic Total Occlusion between January 2008 and June 2015 were assessed. The mean patient age was 63.9±10.9 years; 85% were men. Procedural success increased from 79.7% to 89.3% through the study period. Patients enrolled during the years had increasing comorbidities and lesion complexity (J-CTO score [Multicenter CTO Registry of Japan] increased from 1.76±1.03 in 2008 to 2.17±0.91 in 2015; P for trend, <0.001). Retrograde approach utilization steadily increased from 10.1% in 2008 to 29.9% in 2015 ( P for trend, <0.001). Antegrade dissection reentry adoption was low, not exceeding 5.5%. In-hospital mortality decreased during the study period from 0.4% to 0.1% ( P for trend, <0.001), whereas in-hospital complication rates remained essentially unchanged, in the range 4.4% to 5.2% ( P for trend, 0.390). CONCLUSIONS: Chronic total occlusion percutaneous coronary intervention has shown a steady increase in procedural success rate over time, with unchanged complication rates, despite the increasing complexity of the lesions attempted. The J-CTO score predictive value for procedural success was low for the entire registry and had no predictive ability for the retrograde approach.


Assuntos
Oclusão Coronária/terapia , Intervenção Coronária Percutânea/tendências , Idoso , Doença Crônica , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/mortalidade , Europa (Continente)/epidemiologia , Feminino , Mortalidade Hospitalar/tendências , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Sistema de Registros , Fatores de Tempo , Resultado do Tratamento
13.
Int J Cardiol ; 254: 36-42, 2018 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-29407124

RESUMO

BACKGROUND: The prevalence and associated-risk of asymptomatic multisite artery disease (MSAD) in high risk coronary patients are unknown. Whether systematic identification and aggressive management of asymptomatic MSAD is clinically relevant in high risk coronary patients has not been evaluated. METHODS: We randomly assigned 521 high risk coronary patients defined by the presence of three-vessel coronary disease (n=304) or recent acute coronary syndrome beyond the age of 75years (n=215) to either a strategy of systematic detection of asymptomatic MSAD combined with an aggressive secondary prevention (n=263) or to a more conventional strategy based on treatment of coronary artery disease only with standard of care (n=258). The primary end point was the time to first occurrence of death, any organ failure or ischemic event leading to re-hospitalization through two years of follow-up. RESULTS: The pro-active strategy identified asymptomatic MSAD in 21.7% of patients with few revascularizations (3.6%); the pro-active pharmacological secondary prevention was obtained in >85% of patients and life-style changes in <60% of patients. At 2-year follow-up, the primary end point occurred in 44.9% of patients in the pro-active group and 43.0% of patients in the conventional group (HR 1.03; 95% confidence interval [CI], 0.80 to 1.34]. The rate of major bleeding did not differ significantly between groups (4.6% vs 5.0%; HR, 0.97; 95% CI, 0.40 to 1.91). CONCLUSION: In high risk coronary patients, there is no apparent benefit of a systematic detection of asymptomatic extra-coronary atherothrombotic disease and intensified treatment over a 2-year follow-up period. (Funded by the Academic Allies in Cardiovascular Trials Initiatives and Organized Networks and Institut de l'Athérothrombose; AMERICA ClinicalTrials.gov number, NCT00445835).


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/prevenção & controle , Comportamento de Redução do Risco , Prevenção Secundária/métodos , Índice de Gravidade de Doença , Idoso , Idoso de 80 Anos ou mais , Doença da Artéria Coronariana/epidemiologia , Quimioterapia Combinada , Feminino , Seguimentos , França/epidemiologia , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/tendências , Inibidores da Agregação Plaquetária/administração & dosagem , Fatores de Risco
14.
EuroIntervention ; 12(13): 1595-1604, 2017 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-27840322

RESUMO

AIMS: The aim of the study was to compare the safety and efficacy of the platinum-chromium-based everolimus-eluting stent (EES) with a cobalt-chromium EES. METHODS AND RESULTS: We performed a prospective, multicentre, single-blind non-inferiority all-comers study randomising patients with stable or unstable coronary artery disease (2:1) to treatment with the platinum-chromium EES (n=1,952) or the control cobalt-chromium EES (n=1,028) in Europe (PLATINUM PLUS trial). The primary endpoint was target vessel failure (TVF) at 12 months, a composite of target vessel-related cardiac death, myocardial infarction (MI), and ischaemia-driven target vessel revascularisation (TVR). Among 2,980 patients, 33% presented with acute coronary syndromes, and 48% with multivessel disease. At 12 months, the intention-to-treat analysis determined that the platinum-chromium EES was non-inferior to the cobalt-chromium EES for the primary endpoint (86 [4.6%] patients vs. 32 [3.2%], absolute difference 1.4%, 95% confidence interval [CI]: -0.1-2.9; upper limit of the one-sided 95% CI: 2.57%; non-inferiority p=0.012; superiority analysis: hazard ratio [HR] 1.44, 95% CI: 0.96-2.16, p=0.08). In the per protocol analysis, however, the primary endpoint was significantly more common in the platinum-chromium EES (HR 1.64, 95% CI: 1.05-2.55, p=0.03). There were no significant differences in the rates of cardiac death (1.1% vs. 1.0%, p=0.78), MI (1.6% vs. 0.8%, p=0.09), or ischaemia-driven TLR (2.0% vs. 1.6%, p=0.49). The rates of ARC definite or probable stent thrombosis were comparable between platforms (0.8% vs. 0.5%, p=0.44). CONCLUSIONS: At one year, the platinum-chromium EES satisfied the pre-specified criteria for non-inferiority relative to the control cobalt-chromium EES in this all-comers trial.


Assuntos
Stents Farmacológicos , Everolimo/uso terapêutico , Infarto do Miocárdio/terapia , Intervenção Coronária Percutânea , Platina/uso terapêutico , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/métodos , Estudos Prospectivos , Resultado do Tratamento
15.
EuroIntervention ; 12(16): 1987-1994, 2017 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-27840326

RESUMO

AIMS: Bioabsorbable polymer drug-eluting stents (DES) may reduce the inflammation and delayed healing associated with some permanent polymer-coated DES. Whether late clinical outcomes are improved, particularly among patients with medically treated diabetes, is unknown. Therefore, we analysed outcomes from a pre-specified substudy of the EVOLVE II trial to evaluate the safety and effectiveness of the SYNERGY stent in patients with diabetes mellitus. METHODS AND RESULTS: SYNERGY is a thin-strut, platinum-chromium everolimus-eluting stent with an ultra-thin bioabsorbable poly(DL-lactide-co-glycolide) abluminal polymer. The EVOLVE II randomised, controlled trial proved the non-inferiority of the SYNERGY versus the PROMUS Element Plus stent for one-year target lesion failure (TLF: ischaemia-driven target lesion revascularisation [ID-TLR], target vessel myocardial infarction [TVMI], or cardiac death). The pre-specified EVOLVE II diabetes substudy prospectively pooled randomised patients with diabetes (N=263) with a sequential single-arm diabetic cohort (n=203). The substudy primary endpoint was one-year TLF compared with a pre-specified performance goal (14.5%). The primary endpoint occurred in 7.5% of SYNERGY-treated patients with diabetes, significantly less than the performance goal (p<0.0001). The two-year rate of TLF was 11.2% (cardiac death 1.5%, TVMI 6.4%, ID-TLR 6.8%) and definite/probable stent thrombosis occurred in 1.1% of patients. CONCLUSIONS: The EVOLVE II diabetes substudy demonstrates the efficacy and safety of the SYNERGY stent in patients with medically treated diabetes.


Assuntos
Implantes Absorvíveis , Complicações do Diabetes , Diabetes Mellitus , Stents Farmacológicos , Everolimo/uso terapêutico , Infarto do Miocárdio/cirurgia , Sirolimo/uso terapêutico , Implantes Absorvíveis/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Morte , Stents Farmacológicos/efeitos adversos , Everolimo/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/complicações , Intervenção Coronária Percutânea/métodos , Polímeros/efeitos adversos , Resultado do Tratamento
16.
Lancet ; 388(10055): 2015-2022, 2016 Oct 22.
Artigo em Inglês | MEDLINE | ID: mdl-27581531

RESUMO

BACKGROUND: Elderly patients are at high risk of ischaemic and bleeding events. Platelet function monitoring offers the possibility to individualise antiplatelet therapy to improve the therapeutic risk-benefit ratio. We aimed to assess the effect of platelet function monitoring with treatment adjustment in elderly patients stented for an acute coronary syndrome. METHODS: We did this multicentre, open-label, blinded-endpoint, randomised controlled superiority study at 35 centres in France. Patients aged 75 years or older who had undergone coronary stenting for acute coronary syndrome were randomly assigned (1:1), via a central interactive voice-response system based on a computer-generated permuted-block randomisation schedule with randomly selected block sizes, to receive oral prasugrel 5 mg daily with dose or drug adjustment in case of inadequate response (monitoring group) or oral prasugrel 5 mg daily with no monitoring or treatment adjustment (conventional group). Randomisation was stratified by centre. Platelet function testing was done 14 days after randomisation and repeated 14 days after treatment adjustment in patients in the monitoring group. Study investigators and patients were not masked to treatment allocation, but allocation was concealed from an independent clinical events committee responsible for endpoint adjudication. The primary endpoint was a composite of cardiovascular death, myocardial infarction, stroke, stent thrombosis, urgent revascularisation, and Bleeding Academic Research Consortium-defined bleeding complications (types 2, 3, or 5) at 12 months' follow-up. We did analysis by intention to treat. This trial is registered with ClinicalTrials.gov, number NCT01538446. FINDINGS: Between March 27, 2012, and May 19, 2015, we randomly assigned 877 patients to the monitoring group (n=442) or the conventional group (n=435). The primary endpoint occurred in 120 (28%) patients in the monitoring group compared with 123 (28%) patients in the conventional group (hazard ratio [HR], 1·003, 95% CI 0·78-1·29; p=0·98). Rates of bleeding events did not differ significantly between groups. INTERPRETATION: Platelet function monitoring with treatment adjustment did not improve the clinical outcome of elderly patients treated with coronary stenting for an acute coronary syndrome. Platelet function testing is still being used in many centres and international guidelines still recommend platelet function testing in high-risk situations. Our study does not support this practice or these recommendations. FUNDING: Eli Lilly and Company, Daiichi Sankyo, Stentys, Accriva Diagnostics, Medtronic, and Fondation Coeur et Recherche.


Assuntos
Síndrome Coronariana Aguda/cirurgia , Monitorização Fisiológica , Inibidores da Agregação Plaquetária/administração & dosagem , Testes de Função Plaquetária , Cloridrato de Prasugrel/administração & dosagem , Stents , Síndrome Coronariana Aguda/terapia , Idoso , Idoso de 80 Anos ou mais , Esquema de Medicação , Feminino , Humanos , Masculino , Intervenção Coronária Percutânea , Medição de Risco
17.
Clin Cardiol ; 39(4): 192-200, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26880570

RESUMO

There is an apparent benefit with extension of dual antiplatelet therapy (DAPT) beyond 1 year after implantation of drug-eluting stents (DES). Assessment by a Double Randomization of a Conventional Antiplatelet Strategy vs a Monitoring-Guided Strategy for Drug-Eluting Stent Implantation, and of Treatment Interruption vs Continuation One Year After Stenting (ARCTIC)-Generation assessed whether there is a difference of outcome between first- vs second-generation DES and if there is an interaction with DAPT duration in the ARCTIC-Interruption study. ARCTIC-Interruption randomly allocated 1259 patients 1 year after stent implantation to a strategy of interruption of DAPT (n = 624), in which aspirin antiplatelet treatment only was maintained, or DAPT continuation (n = 635) for 6 to 18 additional months. The primary endpoint was the composite of death, myocardial infarction, stent thrombosis, stroke, or urgent revascularization. A total of 520 and 722 patients received a first- and a second-generation DES, respectively. After a median follow-up of 17 months (interquartile range, 15-18 months) after randomization, the primary endpoint occurred in 32 (6.2%) and 19 (2.6%) patients with first- and second-generation DES, respectively (hazard ratio: 2.31, 95% confidence interval: 1.31-4.07, P = 0.004). This was observed irrespective of the strategy of interruption or continuation of DAPT and timing of study recruitment. Major bleeding events occurred in 4 (0.8%) and 3 patients (0.4%) with first- and second-generation DES, respectively (hazard ratio: 1.79, 95% confidence interval: 0.40-8.02, P = 0.44). Results did not change after multiple adjustments for potential confounding variables. ARCTIC-Generation showed worse clinical outcome with first- vs second-generation DES, a difference that appeared to persist even with prolonged DAPT.


Assuntos
Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Inibidores da Agregação Plaquetária/administração & dosagem , Idoso , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Trombose Coronária/etiologia , Esquema de Medicação , Quimioterapia Combinada , Feminino , França , Hemorragia/induzido quimicamente , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Inibidores da Agregação Plaquetária/efeitos adversos , Estudos Prospectivos , Desenho de Prótese , Fatores de Risco , Acidente Vascular Cerebral/etiologia , Fatores de Tempo , Resultado do Tratamento
18.
Eur J Clin Pharmacol ; 71(11): 1315-24, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26265231

RESUMO

BACKGROUND: The ARCTIC study randomized 2440 patients scheduled for stent implantation to a strategy of platelet function monitoring with drug adjustment in patients who had a poor response to antiplatelet therapy or to a conventional strategy without monitoring and drug adjustment. No significant improvement in clinical outcomes with platelet function monitoring was observed. OBJECTIVE: The purpose of this study is to assess the relationships between CYP2C19 genotypes, clopidogrel pharmacodynamic response, and clinical outcome. METHODS AND RESULTS: In the ARCTIC-GENE study, 1394 patients were genotyped for loss- and gain-of-function CYP2C19 alleles. Randomization of treatment strategy was well balanced. Slow metabolizers identified as carriers of at least one loss-of-function allele CYP2C19*2 (n = 459) were more likely poor responders at randomization (41.6 vs. 31.6%, p = 0.0112) and 14 days later (23.8 vs. 10.4%, p < 0.0001) and more frequently on prasugrel (11.5 vs. 8.1%, p = 0.039) as compared with rapid metabolizers (n = 935). Intensification of antiplatelet treatment did not differ between slow and rapid metabolizers according to the study algorithm based on platelet function only. The primary study outcome defined as the composite of death, myocardial infarction, stent thrombosis, stroke, or urgent revascularization 1 year after stent implantation did not differ between slow and rapid metabolizers (HR 0.988, 95% CI [0.812;1.202], p = 0.90). Likewise, the primary safety outcome did not differ between rapid and slow metabolizer phenotype. CONCLUSIONS: The genetic clopidogrel profile was a good marker of platelet function response on clopidogrel but was not related to clinical outcome suggesting that the genetic added little to the pharmacodynamic information used in the study to adjust antiplatelet therapy. ClinicalTrials.gov: NCT00827411.


Assuntos
Citocromo P-450 CYP2C19/genética , Inibidores da Agregação Plaquetária/uso terapêutico , Trombose/prevenção & controle , Ticlopidina/análogos & derivados , Idoso , Clopidogrel , Citocromo P-450 CYP2C19/metabolismo , Feminino , Genótipo , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea , Agregação Plaquetária/efeitos dos fármacos , Inibidores da Agregação Plaquetária/farmacologia , Testes de Função Plaquetária , Stents/efeitos adversos , Trombose/genética , Trombose/metabolismo , Ticlopidina/farmacologia , Ticlopidina/uso terapêutico , Resultado do Tratamento
19.
J Am Coll Cardiol ; 65(22): 2388-400, 2015 Jun 09.
Artigo em Inglês | MEDLINE | ID: mdl-26046732

RESUMO

BACKGROUND: A retrograde approach improves the success rate of percutaneous coronary interventions (PCIs) for chronic total occlusions (CTOs). OBJECTIVES: The authors describe the European experience with and outcomes of retrograde PCI revascularization for coronary CTOs. METHODS: Follow-up data were collected from 1,395 patients with 1,582 CTO lesions enrolled between January 2008 and December 2012 for retrograde CTO PCI at 44 European centers. Major adverse cardiac and cerebrovascular events were defined as the composite of cardiac death, myocardial infarction, stroke, and further revascularization. RESULTS: The mean patient age was 62.0 ± 10.4 years; 88.5% were men. Procedural and clinical success rates were 75.3% and 71.2%, respectively. The mean clinical follow-up duration was 24.7 ± 15.0 months. Compared with patients with failed retrograde PCI, successfully revascularized patients showed lower rates of cardiac death (0.6% vs. 4.3%, respectively; p < 0.001), myocardial infarction (2.3% vs. 5.4%, respectively; p = 0.001), further revascularization (8.6% vs. 23.6%, respectively; p < 0.001), and major adverse cardiac and cerebrovascular events (8.7% vs. 23.9%, respectively; p < 0.001). Female sex (hazard ratio [HR]: 2.06; 95% confidence interval [CI]: 1.33 to 3.18; p = 0.001), prior PCI (HR: 1.73; 95% CI: 1.16 to 2.60; p = 0.011), low left ventricular ejection fraction (HR: 2.43; 95% CI: 1.22 to 4.83; p = 0.011), J-CTO (Multicenter CTO Registry in Japan) score ≥3 (HR: 2.08; 95% CI: 1.32 to 3.27; p = 0.002), and procedural failure (HR: 2.48; 95% CI: 1.72 to 3.57; p < 0.001) were independent predictors of major adverse cardiac and cerebrovascular events at long-term follow-up. CONCLUSIONS: The number of retrograde procedures in Europe has increased, with high percents of success, low rates of major complications, and good long-term outcomes.


Assuntos
Oclusão Coronária/cirurgia , Hospitais , Intervenção Coronária Percutânea/métodos , Complicações Pós-Operatórias/epidemiologia , Sistema de Registros , Doença Crônica , Angiografia Coronária , Oclusão Coronária/diagnóstico , Oclusão Coronária/mortalidade , Eletrocardiografia , Europa (Continente)/epidemiologia , Feminino , Seguimentos , Mortalidade Hospitalar/tendências , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Fatores de Tempo , Resultado do Tratamento
20.
Am Heart J ; 168(5): 674-81, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25440795

RESUMO

BACKGROUND: Elderly patients are at high risk for both ischemic and bleeding events. Platelet monitoring offers the opportunity to individualized antiplatelet therapy to optimize the therapeutic risk/benefit ratio. STUDY DESIGN: The ANTARCTIC study is designed to demonstrate the superiority of a strategy of platelet function monitoring with dose and drug adjustment in patients initially on prasugrel 5 mg as compared with a more conventional strategy using prasugrel 5 mg without monitoring and without adjustment (Conventional Treatment Arm) to reduce the primary end point evaluated 1 year after stent percutaneous coronary intervention in elderly patients presenting with an acute coronary syndrome (ACS). ANTARCTIC is a multicenter, prospective, open-label study with 2 parallel arms. A total of 852 elderly patients (≥ 75 years) undergoing stent percutaneous coronary intervention for ACS are to be enrolled. The primary end point is the time to first occurrence of cardiovascular death, myocardial infarction, stroke, definite stent thrombosis, urgent revascularization, and bleeding complications (Bleeding Academic Research Consortium definition 2, 3, or 5). Platelet function analyses will be performed 14 days after randomization and repeated 14 days later in patients who require a change in treatment. CONCLUSION: ANTARCTIC is a nationwide, prospective, open-label study testing a strategy of platelet function monitoring with dose and drug adjustment to reduce ischemic and bleeding complications in elderly ACS patients undergoing coronary stenting.


Assuntos
Síndrome Coronariana Aguda/terapia , Monitoramento de Medicamentos/métodos , Hemorragia/prevenção & controle , Isquemia Miocárdica/prevenção & controle , Intervenção Coronária Percutânea , Piperazinas/uso terapêutico , Antagonistas do Receptor Purinérgico P2Y/uso terapêutico , Stents , Tiofenos/uso terapêutico , Idoso , Idoso de 80 Anos ou mais , Relação Dose-Resposta a Droga , Humanos , Testes de Função Plaquetária , Cloridrato de Prasugrel , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA