Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Biomed Khim ; 66(4): 317-325, 2020 Jul.
Artigo em Russo | MEDLINE | ID: mdl-32893821

RESUMO

Express MS identification of biological tissues has become a much more accessible research method due to the application of direct specimen ionization at atmospheric pressure. In contrast to traditional methods of analysis employing GC-MS methods for determining the molecular composition of the analyzed objects it eliminates the influence of mutual ion suppression. Despite significant progress in the field of direct MS of biological tissues, the question of mass spectrometric profile attribution to a certain type of tissue still remains open. The use of modern machine learning methods and protocols (e.g., "random forests") enables us to trace possible relationships between the components of the sample MS profile and the result of brain tumor tissue classification (astrocytoma or glioblastoma). It has been shown that the most pronounced differences in the mass spectrometric profiles of these tumors are due to their lipid composition. Detection of statistically significant differences in lipid profiles of astrocytoma and glioblastoma may be used to perform an express test during surgery and inform the neurosurgeon what type of malignant tissue he is working with. The ability to accurately determine the boundaries of the neoplastic growth significantly improves the quality of both surgical intervention and postoperative rehabilitation, as well as the duration and quality of life of patients.


Assuntos
Astrocitoma , Biomarcadores Tumorais , Neoplasias Encefálicas , Glioblastoma , Lipídeos , Biomarcadores Tumorais/análise , Neoplasias Encefálicas/diagnóstico , Glioblastoma/diagnóstico , Humanos , Lipídeos/análise , Masculino , Qualidade de Vida
2.
Sci Rep ; 9(1): 914, 2019 01 29.
Artigo em Inglês | MEDLINE | ID: mdl-30696886

RESUMO

In this work, we demonstrate a new approach for assessing the stability and reproducibility of mass spectra obtained via ambient ionization methods. This method is suitable for both comparing experiments during which only one mass spectrum is measured and for evaluating the internal homogeneity of mass spectra collected over a period of time. The approach uses Pearson's r coefficient and the cosine measure to compare the spectra. It is based on the visualization of dissimilarities between measurements, thus leading to the analysis of dissimilarity patterns. The cosine measure and correlations are compared to obtain better metrics for spectra homogeneity. The method filters out unreliable scans to prevent the analyzed sample from being wrongly characterized. The applicability of the method is demonstrated on a set of brain tumor samples. The developed method could be employed in neurosurgical applications, where mass spectrometry is used to monitor the intraoperative tumor border.

3.
Clin Mass Spectrom ; 12: 37-46, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34841078

RESUMO

The majority of research in the biomedical sciences is carried out with the highest resolution accessible to the scientist, but, in the clinic, cost constraints necessitate the use of low-resolution devices. Here, we compare high- and low-resolution direct mass spectrometry profiling data and propose a simple pre-processing technique that makes high-resolution data suitable for the development of classification and regression techniques applicable to low-resolution data, while retaining high accuracy of analysis. This work demonstrates an approach to de-noising spectra to make the same representation for both high- and low-resolution spectra. This approach uses noise threshold detection based on the Tversky index, which compares spectra with different resolutions, and minimizes the percentage of resolution-specific peaks. The presented method provides an avenue for the development of analytical algorithms using high-resolution mass spectrometry data, while applying these algorithms in the clinic using low-resolution mass spectrometers.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA