Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
J Am Soc Mass Spectrom ; 34(1): 119-122, 2023 Jan 04.
Artigo em Inglês | MEDLINE | ID: mdl-36535019

RESUMO

Rapid and reliable methods for detecting tumor margins are crucial for neuro-oncology. Several mass spectrometry-based methods have been recently proposed to address this problem. Inline Cartridge Extraction (ICE) demonstrates the potential for clinical application, based on ex-vivo analysis of dissected tissues, but requires time-consuming steps to avoid cross-contamination. In this work, a method of incorporating a disposable electrospray emitter into the ICE cartridge by PEEK sleeves melting is developed. It reduces total analysis time and improves throughput. The proposed setup also improves the robustness of the ICE molecular profiling as demonstrated with human glial tumor samples in that stability and reproducibility of the spectra were increased.


Assuntos
Espectrometria de Massas por Ionização por Electrospray , Humanos , Espectrometria de Massas por Ionização por Electrospray/métodos , Reprodutibilidade dos Testes
2.
Molecules ; 27(8)2022 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-35458785

RESUMO

Ex-vivo molecular profiling has recently emerged as a promising method for intraoperative tissue identification, especially in neurosurgery. The short-term storage of resected samples at room temperature is proposed to have negligible influence on the lipid molecular profiles. However, a detailed investigation of short-term molecular profile stability is required to implement molecular profiling in a clinic. This study evaluates the effect of storage media, temperature, and washing solution to determine conditions that provide stable and reproducible molecular profiles, with the help of ambient ionization mass spectrometry using rat cerebral cortex as model brain tissue samples. Utilizing normal saline for sample storage and washing media shows a positive effect on the reproducibility of the spectra; however, the refrigeration shows a negligible effect on the spectral similarity. Thus, it was demonstrated that up to hour-long storage in normal saline, even at room temperature, ensures the acquisition of representative molecular profiles using ambient ionization mass spectrometry.


Assuntos
Encéfalo , Solução Salina , Animais , Lipídeos/análise , Espectrometria de Massas , Ratos , Reprodutibilidade dos Testes
3.
Sci Rep ; 9(1): 18960, 2019 12 12.
Artigo em Inglês | MEDLINE | ID: mdl-31831871

RESUMO

The development of perspective diagnostic techniques in medicine requires efficient high-throughput biological sample analysis methods. Here, we present an inline cartridge extraction that facilitates the screening rate of mass spectrometry shotgun lipidomic analysis of tissue samples. We illustrate the method by its application to tumor tissue identification in neurosurgery. In perspective, this high-performance method provides new possibilities for the investigation of cancer pathogenesis and metabolic disorders.


Assuntos
Neoplasias Encefálicas/metabolismo , Espectrometria de Massas , Manejo de Espécimes/instrumentação , Manejo de Espécimes/métodos , Feminino , Humanos , Masculino
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA