Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
1.
Medicine (Baltimore) ; 97(15): e0388, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29642199

RESUMO

BACKGROUND: Aim of this study was to systematically combine tube voltage adaptation and iterative reconstructions for reduction of iodine and radiation dose. METHODS: Settings for the study protocol were evaluated in ex-ante trials to provide image quality that is comparable to a reference protocol at 120 kV with tube current modulation. Consecutive patients were randomized to undergo computed tomography (CT) of the chest using the study protocol (n = 62) or reference protocol (n = 50). Objective and subjective image quality was assessed and compared. RESULTS: Tube voltage was decreased to 100 kV in 47 patients and to 80 kV in 15 patients in the study group. The iodine dosage (16.1 vs 10.5 g) and the effective radiation dose (3.6 vs 2.5 mSv) were significantly decreased in the study group (both P < .001). Contrast-to-noise ratio was comparable in the pulmonary trunk and increased in the aorta (P < .01). Subjective image quality was comparable without statistically significance. CONCLUSIONS: Simultaneous reductions in iodine dosage and radiation dose by one-third are feasible for CT of the chest.


Assuntos
Meios de Contraste , Iodo , Doses de Radiação , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Radiografia Torácica/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Método Duplo-Cego , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Estudos Prospectivos
2.
Acad Radiol ; 23(4): 406-12, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26853970

RESUMO

RATIONALE AND OBJECTIVES: This study aimed to develop and implement a respiratory-gated setup for dual-source computed tomography (CT) at high pitch to examine patients in a reproducible inspiratory phase. MATERIALS AND METHODS: Twenty-one patients underwent free-breathing respiratory-gated chest CT using a high-pitch scan mode no more than 6 months after inspiratory breath-held nongated CT, which serves as reference. Scan parameters were as follows: pitch = 3.4, 128 × 0.6 mm collimation, 0.28 s gantry rotation time, and 150 ref.mAs per tube at 120 kV. The examinations were triggered using the tidal wave provided by a respiratory-gating system as input signal. Image quality was assessed focusing on artifacts and delineation of the anatomical and pathological structures. Lung volumes were measured on both free-breathing and reference examinations. RESULTS: All examinations were performed without complications. Image quality was high with both protocols. Significantly less motion artifacts were recorded with the high-pitch mode compared to the reference (P = 0.02). Most of the artifacts were located in the peripheral parts of the lower lobes for the study group and in the central part of the left lower lobe for the reference. Average total lung volume was 4.5 ± 1.5 L in respiratory-gated examinations and 5.8 ± 0.9 L in examinations with breath-hold in inspiration. CONCLUSIONS: High-pitch chest CT scanning during free breathing minimizes motion artifacts, improving image quality in patients with limited breath-holding abilities. To assure scanning in an inspiratory phase, data acquisition should be triggered with a respiratory-gating system.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Pulmão/diagnóstico por imagem , Tomografia Computadorizada Espiral/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Artefatos , Suspensão da Respiração , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Respiração , Tomografia Computadorizada Espiral/efeitos adversos , Tomografia Computadorizada por Raios X/métodos
3.
Acad Radiol ; 22(12): 1516-21, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26411380

RESUMO

RATIONALE AND OBJECTIVES: The aim of this study was to determine the optimal arterial phase delay for computed tomography imaging of hepatocellular carcinoma (HCC) before and after transarterial chemoembolization (TACE) using a low iodine dose protocol. MATERIALS AND METHODS: A total of 39 patients with known HCC were imaged with dynamic computed tomography of the liver (40-second scan duration, 60 mL of contrast medium), both on the same day before TACE and 1 day after TACE. Time attenuation curves of vessels, nonmalignant liver parenchyma, and 62 HCCs were normalized to a uniform aortic contrast arrival and analyzed. RESULTS: Maximal arterial phase HCC to liver contrast was reached between 13 and 17 seconds after aortic contrast arrival, both before and after TACE. CONCLUSIONS: Using our low iodine dose protocol, arterial phase imaging of HCC should be performed between 13 and 17 seconds after aortic contrast arrival, both before and after TACE.


Assuntos
Carcinoma Hepatocelular/diagnóstico por imagem , Artéria Hepática/diagnóstico por imagem , Neoplasias Hepáticas/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Carcinoma Hepatocelular/terapia , Quimioembolização Terapêutica , Meios de Contraste , Feminino , Humanos , Iopamidol/análogos & derivados , Neoplasias Hepáticas/terapia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Tomografia Computadorizada Espiral/métodos
4.
Radiology ; 277(2): 406-12, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26225451

RESUMO

PURPOSE: To evaluate the ability of magnetic resonance (MR) imaging to induce deoxyribonucleic acid (DNA) damage in patients who underwent cardiac MR imaging in daily routine by using γ-H2AX immunofluorescence microscopy. MATERIALS AND METHODS: This study complies with the Declaration of Helsinki and was performed according to local ethics committee approval. Informed patient consent was obtained. Blood samples from 45 patients (13 women, 32 men; mean age, 50.3 years [age range, 20-89 years]) were obtained before and after contrast agent-enhanced cardiac MR imaging. MR imaging-induced double-strand breaks (DSBs) were quantified in isolated blood lymphocytes by using immunofluorescence microscopy after staining the phosphorylated histone variant γ-H2AX. Twenty-nine patients were examined with a myocarditis protocol (group A), 10 patients with a stress-testing protocol (group B), and six patients with flow measurements and angiography (group C). Paired t test was performed to compare excess foci before and after MR imaging. RESULTS: The mean baseline DSB level before MR imaging and 5 minutes after MR imaging was, respectively, 0.116 DSB per cell ± 0.019 (standard deviation) and 0.117 DSB per cell ± 0.019 (P = .71). There was also no significant difference in DSBs in these subgroups (group A: DSB per cell before and after MR imaging, respectively, 0.114 and 0.114, P = .91; group B: DSB per cell before and after MR imaging, respectively, 0.123 and 0.124, P = .78; group C: DSB per cell before and after MR imaging, respectively, 0.114 and 0.115, P = .36). CONCLUSION: By using γ-H2AX immunofluorescence microscopy, no DNA DSBs were detected after cardiac MR imaging.


Assuntos
Quebras de DNA de Cadeia Dupla , Cardiopatias/diagnóstico , Linfócitos , Imageamento por Ressonância Magnética , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Feminino , Humanos , Masculino , Microscopia de Fluorescência , Pessoa de Meia-Idade
5.
Medicine (Baltimore) ; 94(26): e1058, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26131822

RESUMO

Computed tomography angiography (CTA) of carotid arteries and vertebrobasilar system is a standardized procedure with excellent image quality, but radiation exposure remains a matter of concern. The aim of this study is to examine to what extent radiation dose can be lowered in relation to a standard protocol by simulating examinations with lower tube currents applying a dedicated software.Lower tube current was simulated by a dedicated noise insertion and reconstruction software (ReconCT). In a phantom study, true scans were performed with different dose protocols and compared to the results of simulated dose reductions of the same degree, respectively. In a patient study, 30 CTAs of supra-aortic vessels were reconstructed at a level of 100%, 75%, 50%, and 25% of the initial dose. Objective and subjective image analyses were performed.No significant noise differences between true scans and simulated scans of mimicked contrasted vessels were found. In the patient study, the quality scores of the 4 dose groups differed statistically significant; this difference vanished for the comparison of the 100% and 75% datasets after dichotomization into the categories of diagnostic and nondiagnostic image quality (P = .50).This study suggests an easy-to-implement method of simulating CTAs of carotid arteries and vertebrobasilar system with lower tube current for dose reduction by artificially adding noise to the original raw data. Lowering the radiation dose in a moderate extent to 75% of the original dose levels does not significantly alter the diagnostic image quality.


Assuntos
Artérias Carótidas/diagnóstico por imagem , Artéria Vertebral/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Angiografia , Artéria Basilar/diagnóstico por imagem , Encéfalo/irrigação sanguínea , Circulação Cerebrovascular , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Melhoria de Qualidade , Doses de Radiação , Tomografia Computadorizada por Raios X
6.
PLoS One ; 10(5): e0127142, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25996998

RESUMO

BACKGROUND: Radiation exposure occurs in X-ray guided interventional procedures or computed tomography (CT) and γ-H2AX-foci are recognized to represent DNA double-strand breaks (DSBs) as a biomarker for radiation induced damage. Antioxidants may reduce the induction of γ-H2AX-foci by binding free radicals. The aim of this study was to establish a dose-effect relationship and a time-effect relationship for the individual antioxidants on DSBs in human blood lymphocytes. MATERIALS AND METHODS: Blood samples from volunteers were irradiated with 10 mGy before and after pre-incubation with different antioxidants (zinc, trolox, lipoic acid, ß-carotene, selenium, vitamin E, vitamin C, N-acetyl-L-cysteine (NAC) and Q 10). Thereby, different pre-incubation times, concentrations and combinations of drugs were evaluated. For assessment of DSBs, lymphocytes were stained against the phosphorylated histone variant γ-H2AX. RESULTS: For zinc, trolox and lipoic acid regardless of concentration or pre-incubation time, no significant decrease of γ-H2AX-foci was found. However, ß-carotene (15%), selenium (14%), vitamin E (12%), vitamin C (25%), NAC (43%) and Q 10 (18%) led to a significant reduction of γ-H2AX-foci at a pre-incubation time of 1 hour. The combination of different antioxidants did not have an additive effect. CONCLUSION: Antioxidants administered prior to irradiation demonstrated the potential to reduce γ-H2AX-foci in blood lymphocytes.


Assuntos
Antioxidantes/farmacologia , Quebras de DNA de Cadeia Dupla/efeitos dos fármacos , Quebras de DNA de Cadeia Dupla/efeitos da radiação , Histonas/metabolismo , Microscopia de Fluorescência , Raios X/efeitos adversos , Adulto , Relação Dose-Resposta a Droga , Feminino , Humanos , Linfócitos/efeitos dos fármacos , Linfócitos/metabolismo , Linfócitos/efeitos da radiação , Masculino , Pessoa de Meia-Idade
7.
Invest Radiol ; 50(5): 352-60, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25591129

RESUMO

OBJECTIVES: The objective of this study was to evaluate the radiation dose and image quality performance of thoracoabdominal examinations with an automated tube voltage selection (tube voltage adaptation), tube current modulation, and high pitch using a third-generation dual-source computed tomography (CT) compared intraindividually with 120-kV examinations with tube current modulation with special attention on clinically relevant lesions in the liver, the lungs, and extrahepatic soft tissues. MATERIALS AND METHODS: This study was approved by the institutional review board. Computed tomography of the body was performed using a third-generation dual-source system in 95 patients (mean body mass index, 25 kg/m²; range, 18-35 kg/m²). For 49 of these patients, all calculated tube settings and resulting dose values were recorded for each of the 12 gradual contrast weightings of the tube voltage adaptation algorithm. Spiral CT was performed for all patients with an intermediate weighting (grade 7) in a portal venous phase at 120 reference kV, 180 reference mAs, and pitch of 1.55. Objective image quality was assessed on the basis of contrast-to-noise ratio. Subjective image quality was assessed on the basis of clarity and sharpness of anatomical and pathological structures as well as interfering beam hardening and spiral and motion artifacts (heart, lungs, diaphragm). Previous examinations on a 64-slice scanner served as reference. RESULTS: All examinations were rated good or excellent for clinical diagnosis. Automated tube voltage selection resulted in significantly lower effective radiation dose (9.5 mSv) compared with the reference (12.0 mSv; P < 0.01). Contrast-to-noise ratio and image quality of soft tissue lesions were significantly increased (P < 0.01). Motion artifacts were significantly reduced (P < 0.01). CONCLUSIONS: Automated tube voltage adaptation combined with high-pitch protocols allows for a substantial radiation dose reduction while substantially increasing the image quality, even at large-volume exposure.


Assuntos
Neoplasias Abdominais/diagnóstico por imagem , Doses de Radiação , Proteção Radiológica/instrumentação , Intensificação de Imagem Radiográfica/instrumentação , Neoplasias Torácicas/diagnóstico por imagem , Adulto , Idoso de 80 Anos ou mais , Desenho de Equipamento , Análise de Falha de Equipamento , Retroalimentação , Humanos , Pessoa de Meia-Idade , Proteção Radiológica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/instrumentação , Radiografia Abdominal/instrumentação , Radiografia Torácica/instrumentação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X
8.
Cardiovasc Intervent Radiol ; 38(1): 152-9, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24798135

RESUMO

PURPOSE: This study was designed to assess efficacy and safety in the treatment of perivascular malignant liver lesions using percutaneous, computed tomography (CT)-guided irreversible electroporation (IRE). METHODS: Fourteen patients (mean age 58 ± 11 years) with 18 malignant liver lesions were consecutively enrolled in this study. IRE was performed in patients not eligible for surgery and lesions abutting large vessels or bile ducts. Follow-up exams were performed using multislice-CT (MS-CT) or MRI. RESULTS: Medium lesion diameter was 20 ± 5 mm. Ten of 14 (71 %) were successfully treated with no local recurrence to date (mean follow-up 388 ± 160 days). One case left initial tumor control unclear and additional RFA was performed 4 weeks after IRE. Complications occurred in 4 of 14 (29 %) cases. In one case, intervention was terminated and abdominal bleeding required laparotomy. In two cases, a postinterventional hematothorax required intervention. In another case, abdominal bleeding could be managed conservatively. No complications related to the bile ducts occurred. CONCLUSIONS: Percutaneous IRE seems to be effective in perivascular lesions but is associated with a higher complication rate compared with thermoablative techniques.


Assuntos
Eletroporação/métodos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/terapia , Tomografia Computadorizada por Raios X , Adulto , Idoso , Feminino , Humanos , Fígado , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
9.
Anticancer Res ; 34(7): 3831-7, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24982410

RESUMO

AIM: To analyze how patients experience Stereotactic guided vacuum-assisted breast biopsy (VABB) both physically and mentally. PATIENTS AND METHODS: Two hundred and eleven consecutive women underwent VABB using one of two different biopsy devices (ATEC® and Mammotome®). Patients were queried using a questionnaire. RESULTS: One hundred and eighty-nine patients were included. 90% would again prefer VABB over a surgical biopsy. Average grading for the condition during the procedure was 2.5 (very good to good) and 2.1 (very good) for the condition the week following VABB. Minor complications were mentioned in 37%. (>90% pain and hematoma). 97% of the women were satisfied by the cosmetic results. Patients with malignant histology and younger age experienced the procedure significantly worse. A significant higher rate of minor complications was found in younger patients and in the ATEC® group. CONCLUSION: VABB is a physical and mental stressor to the women. Nonetheless, the majority of women indeed prefer the VABB.


Assuntos
Biópsia por Agulha/métodos , Mama/patologia , Satisfação do Paciente , Adulto , Idoso , Idoso de 80 Anos ou mais , Biópsia por Agulha/psicologia , Doenças Mamárias/patologia , Neoplasias da Mama/diagnóstico , Neoplasias da Mama/patologia , Calcinose/patologia , Feminino , Humanos , Mamografia , Pessoa de Meia-Idade , Técnicas Estereotáxicas/psicologia , Inquéritos e Questionários
10.
J Cardiovasc Comput Tomogr ; 8(4): 315-22, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25017867

RESUMO

BACKGROUND: Dual-source CT offers accurate depiction of cardiac structures in children with congenital heart disease. For cardiac CT, optimal enhancement of the cardiovascular structures is essential. There is considerable controversy about the administration of contrast medium (CM) in infants and small children, with either a power injector or a manual (hand) injection. OBJECTIVE: The aim of this study was to compare image quality with power injection of CM (study group) and manual injection (control group). METHODS: Thirty-four patients (study group, 6.8 ± 9.6 months and control group, 4.6 ± 8.9 months, nonrandomized) underwent dual-source CT angiography of the chest using a prospective electrocardiography-triggered high-pitch spiral mode (pitch, 3.4; 80 kV). In the study group (17 patients), a power injector was used, and in the control group (17 patients, historical group), manual CM injection had been performed. To assess image quality, both subjective and objective parameters were evaluated independently by 2 experienced radiologists. RESULTS: Subjective overall image quality, signal-to-noise ratio, and contrast-to-noise ratio were significantly higher using power injection compared with manual injection (P < .05). However, depiction of cardiovascular structures did not differ significantly between both groups in all evaluated regions except the superior vena cava and the coronary arteries. CONCLUSION: In infants and small children with congenital heart disease, both manual and power injector protocols allowed for diagnostic imaging of cardiac and extracardiac structures. However, image quality and vascular attenuation were superior using a power injector.


Assuntos
Meios de Contraste/administração & dosagem , Angiografia Coronária/métodos , Vasos Coronários/diagnóstico por imagem , Sistemas de Liberação de Medicamentos/instrumentação , Cardiopatias Congênitas/diagnóstico por imagem , Iohexol/análogos & derivados , Tomografia Computadorizada por Raios X , Fatores Etários , Técnicas de Imagem de Sincronização Cardíaca , Estudos de Casos e Controles , Pré-Escolar , Eletrocardiografia , Desenho de Equipamento , Feminino , Humanos , Lactente , Recém-Nascido , Injeções , Iohexol/administração & dosagem , Masculino , Variações Dependentes do Observador , Valor Preditivo dos Testes , Reprodutibilidade dos Testes
11.
Neuroradiology ; 56(9): 797-803, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24961883

RESUMO

INTRODUCTION: Low tube voltage allows for computed tomography (CT) imaging with increased iodine contrast at reduced radiation dose. We sought to evaluate the image quality and potential dose reduction using a combination of attenuation based tube current modulation (TCM) and automated tube voltage adaptation (TVA) between 100 and 120 kV in CT of the head and neck. METHODS: One hundred thirty consecutive patients with indication for head and neck CT were examined with a 128-slice system capable of TCM and TVA. Reference protocol was set at 120 kV. Tube voltage was reduced to 100 kV whenever proposed by automated analysis of the localizer. An additional small scan aligned to the jaw was performed at a fixed 120 kV setting. Image quality was assessed by two radiologists on a standardized Likert-scale and measurements of signal- (SNR) and contrast-to-noise ratio (CNR). Radiation dose was assessed as CTDIvol. RESULTS: Diagnostic image quality was excellent in both groups and did not differ significantly (p = 0.34). Image noise in the 100 kV data was increased and SNR decreased (17.8/9.6) in the jugular veins and the sternocleidomastoid muscle when compared to 120 kV (SNR 24.4/10.3), but not in fatty tissue and air. However, CNR did not differ statistically significant between 100 (23.5/14.4/9.4) and 120 kV data (24.2/15.3/8.6) while radiation dose was decreased by 7-8%. CONCLUSIONS: TVA between 100 and 120 kV in combination with TCM led to a radiation dose reduction compared to TCM alone, while keeping CNR constant though maintaining diagnostic image quality.


Assuntos
Eletricidade , Cabeça/diagnóstico por imagem , Pescoço/diagnóstico por imagem , Tomografia Computadorizada por Raios X/instrumentação , Adulto , Idoso , Idoso de 80 Anos ou mais , Humanos , Pessoa de Meia-Idade , Estudos Prospectivos , Doses de Radiação
12.
Head Face Med ; 10: 16, 2014 May 12.
Artigo em Inglês | MEDLINE | ID: mdl-24884580

RESUMO

INTRODUCTION: The aim of the study was to compare the detectability of neck vessels with contrast enhanced magnetic resonance angiography (MRA) in the setting of a whole-body MRA and multislice computed tomography angiography (CTA) for preoperative vascular mapping of head and neck. METHODS: In 20 patients MRA was performed prior to microvascular reconstruction of the mandible with osteomyocutaneous flaps. CTA of the neck served as the method of reference.1.5 T contrast enhanced magnetic resonance angiograms were acquired to visualize the vascular structures of the neck in the setting of a whole-body MRA examination. 64-slice spiral computed tomography was performed with a dual-phase protocol, using the arterial phase images for 3D CTA reconstruction. Maximum intensity projection was employed to visualize MRA and CTA data. To retrieve differences in the detectability of vessel branches between MRA and CTA, a McNemar test was performed. RESULTS: All angiograms were of diagnostic quality. There were no statistically significant differences between MRA and CTA for the detection of branches of the external carotid artery that are relevant host vessels for microsurgery (p = 0.118). CTA was superior to MRA if all the external carotid artery branches were included (p < 0.001). CONCLUSIONS: MRA is a reliable alternative to CTA in vascular mapping of the cervical vasculature for planning of microvascular reconstruction of the mandible. In the setting of whole-body MRA it could serve as a radiation free one-stop-shop tool for preoperative assessment of the arterial system, potentially covering both, the donor and host site in one single examination.


Assuntos
Carcinoma de Células Escamosas/patologia , Neoplasias de Cabeça e Pescoço/patologia , Angiografia por Ressonância Magnética , Tomografia Computadorizada Multidetectores , Pescoço/irrigação sanguínea , Adulto , Idoso , Carcinoma de Células Escamosas/cirurgia , Feminino , Cabeça/irrigação sanguínea , Neoplasias de Cabeça e Pescoço/cirurgia , Humanos , Angiografia por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Carcinoma de Células Escamosas de Cabeça e Pescoço
13.
Eur J Radiol ; 82(12): 2386-91, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24050878

RESUMO

OBJECTIVES: To evaluate an automated attenuation-based kV-selection in computed tomography of the chest in respect to radiation dose and image quality, compared to a standard 120 kV protocol. MATERIALS AND METHODS: 104 patients were examined using a 128-slice scanner. Fifty examinations (58 ± 15 years, study group) were performed using the automated adaption of tube potential (100-140 kV), based on the attenuation profile of the scout scan, 54 examinations (62 ± 14 years, control group) with fixed 120 kV. Estimated CT dose index (CTDI) of the software-proposed setting was compared with a 120 kV protocol. After the scan CTDI volume (CTDIvol) and dose length product (DLP) were recorded. Image quality was assessed by region of interest (ROI) measurements, subjective image quality by two observers with a 4-point scale (3--excellent, 0--not diagnostic). RESULTS: The algorithm selected 100 kV in 78% and 120 kV in 22%. Overall CTDIvol reduction was 26.6% (34% in 100 kV) overall DLP reduction was 22.8% (32.1% in 100 kV) (all p<0.001). Subjective image quality was excellent in both groups. CONCLUSION: The attenuation based kV-selection algorithm enables relevant dose reduction (~27%) in chest-CT while keeping image quality parameters at high levels.


Assuntos
Algoritmos , Doses de Radiação , Proteção Radiológica/métodos , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Radiografia Torácica/métodos , Tomografia Computadorizada por Raios X/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
14.
Invest Radiol ; 47(10): 559-65, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22836308

RESUMO

OBJECTIVES: Dose reduction has become a major issue in computed tomography (CT). The benefit of kilovolt (kV) reduction has been demonstrated in CT angiography. We sought to evaluate an attenuation-based fully automated kV-selection and milliampere second-adaption algorithm for CT and to assess radiation dose and image quality in comparison with a standard 120 kV protocol in contrast-enhanced (CE) portal-venous thoracoabdominal imaging. MATERIALS AND METHODS: One hundred patients (mean age, 58.4 ± 5.7 years; mean body mass index [BMI], 26.1 ± 5.1 kg/m(2)) underwent CE CT using automated selection of the tube potential (80-140 kV) with milliampere second adaption based on the attenuation profile of the scout scan. The estimated CT dose index was recorded for the proposed scan setting and standard 120-kV protocol. Regions of interest measurements were performed at different locations for objective assessment of image quality. Signal-to-noise ratio and contrast-to-noise ratio (CNR) were calculated. The subjective image quality was assessed by 2 observers with a 4-point scale using previous CT examinations with the 120-kV standard protocol as the reference for comparison. RESULTS: The kV-selection algorithm could be applied in all examinations without problems. Image quality was high, and there were no significant differences compared with previous examinations of the patients performed at 120 kV. Eighty kilovolts was used in 9% of examinations (mean BMI, 22.8 ± 2.8 kg/m(2)); 100 kV, in 75% (mean BMI, 23.7 ± 4.7 kg/m(2)); 120 kV, in 16% (mean BMI, 30 ± 3.3 kg/m(2)); and 140 kV, in a single case (BMI, 49.4 kg/m(2)). The average estimated CT dose index reduction was 25.3% in the 80-kV group, 14.5% in the 100-kV group, and 11.4% overall. The CNR did not differ significantly, whereas the signal-to-noise ratio was significantly higher in the 80- and 100-kV examinations. CONCLUSION: The attenuation-based kV-selection algorithm was demonstrated to be applicable in clinical routine of CE thoracoabdominal CT, to keep CNR constant, and to result in a significant dose reduction while preserving image quality.


Assuntos
Abdome/efeitos da radiação , Tomografia Computadorizada por Raios X/métodos , Abdome/patologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Competência Clínica , Feminino , Conhecimentos, Atitudes e Prática em Saúde , Humanos , Aumento da Imagem/métodos , Masculino , Pessoa de Meia-Idade , Padrões de Prática Médica , Estatística como Assunto , Estatísticas não Paramétricas , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA