Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Ann Biomed Eng ; 2024 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-38615078

RESUMO

Transcatheter heart valve replacements (TVR) are mostly designed in a closed position (c) with leaflets coaptating. However, recent literature suggests fabricating valves in semi-closed (sc) position to minimize pinwheeling. With about 100,000 children in need of a new pulmonary valve each year worldwide, this study evaluates both geometrical approaches in adult as well as pediatric size and condition. Three valves of each geometry were fabricated in adult (30 mm) and pediatric (15 mm) size, using porcine pericardium. To evaluate performance, the mean transvalvular pressure gradient (TPG), effective orifice area (EOA), and regurgitation fraction (RF) were determined in three different annulus geometries (circular, elliptic, and tilted). For both adult-sized valve geometries, the TPG (TPGC = 2.326 ± 0.115 mmHg; TPGSC = 1.848 ± 0.175 mmHg)* and EOA (EOAC = 3.69 ± 0.255 cm2; EOASC = 3.565 ± 0.025 cm2)* showed no significant difference. Yet the RF as well as its fluctuation was significantly higher for valves with the closed geometry (RFC = 12.657 ± 7.669 %; RFSC = 8.72 ± 0.977 %)*. Recordings showed that the increased backflow was caused by pinwheeling due to a surplus of tissue material. Hydrodynamic testing of pediatric TVRs verified the semi-closed geometry being favourable. Despite the RF (RFC = 7.721 ± 0.348 cm2; RFSC = 5.172 ± 0.679 cm2), these valves also showed an improved opening behaviour ((TPGC = 20.929 ± 0.497 cm2; TPGSC = 15.972 ± 1.158 cm2); (EOAC = 0.629 ± 0.017 cm2; EOASC = 0.731 ± 0.026 cm2)). Both adult and pediatric TVR with semi-closed geometry show better fluiddynamic functionality compared to valves with a closed design due to less pinwheeling. Besides improved short-term functionality, less pinwheeling potentially prevents early valve degeneration and improves durability. *Results are representatively shown for a circular annulus geometry.

2.
Catheter Cardiovasc Interv ; 103(4): 597-606, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38440908

RESUMO

BACKGROUND: Current heart valve implants entail major disadvantages in the treatment for younger patients or those with congenital heart defects. AIM: Evaluation of novel transcatheter pulmonary valve implant made from autologous pericardium with natural crosslinking agent in an in vitro setup and in vivo animal model METHODS: Valves were tested in a pulse duplicator according to ISO-standard 5840. For in vivo studies computer tomography was performed to measure sheep's native pulmonary valve dimensions. Pericardium was harvested by thoracotomy, personalized implants were manufactured and deployed in pulmonary valve position of the same sheep. Every 3 months implant functionality was evaluated by intracardiac echocardiography, intracardiac pressure measurements and cardiac magnetic resonance imaging (cMRI). Implants were explanted for macroscopic and histological examination. RESULTS: In vitro experiments showed compliance with regulatory requirements in terms of valve opening and insufficiency. Five sheep successfully received an autologous valve implant. Two animals had to be euthanized due to trauma sustained in the stable. Long-term valve function was excellent in three out of four animals with median implant cMRI regurgitation fraction of 9% (n = 4) at 3 months, 8% (n = 3) at 6, 8% (n = 3) at 9, 12% (n = 3) at 13, 8% (n = 2) at 17% and 8% (n = 2) at 20.5 months after implantation. Despite good adherence to neighboring tissue and endothelization, histological assessment revealed some signs of degeneration. CONCLUSION: Transcatheter pulmonary valve implants showed promising function for up to 20.5 months encouraging research to further improve this approach.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Valva Pulmonar , Humanos , Adulto , Animais , Ovinos , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Resultado do Tratamento , Valvas Cardíacas/cirurgia , Modelos Animais
3.
Bioengineering (Basel) ; 10(11)2023 Oct 25.
Artigo em Inglês | MEDLINE | ID: mdl-38002371

RESUMO

Biological bioprostheses such as grafts, patches, and heart valves are often derived from biological tissue like the pericardium. These bioprostheses can be of xenogenic, allogeneic, or autologous origin. Irrespective of their origin, all types are pre-treated via crosslinking to render the tissue non-antigenic and mechanically strong or to minimize degradation. The most widely used crosslinking agent is glutaraldehyde. However, glutaraldehyde-treated tissue is prone to calcification, inflammatory degradation, and mechanical injury, and it is incapable of matrix regeneration, leading to structural degeneration over time. In this work, we are investigating an alternative crosslinking method for an intraoperative application. The treated tissue's crosslinking degree was evaluated by differential scanning calorimetry. To confirm the findings, a collagenase assay was conducted. Uniaxial tensile testing was used to assess the tissue's mechanical properties. To support the findings, the treated tissue was visualized using two-photon microscopy. Additionally, fourier transform infrared spectroscopy was performed to study the overall protein secondary structure. Finally, a crosslinking procedure was identified for intraoperative processing. The samples showed a significant increase in thermal and enzymatic stability after treatment compared to the control, with a difference of up to 22.2 °C and 100%, respectively. Also, the tissue showed similar biomechanics to glutaraldehyde-treated tissue, showing greater extensibility, a higher failure strain, and a lower ultimate tensile strength than the control. The significant difference in the structure band ratio after treatment is proof of the introduction of additional crosslinks compared to the untreated control with regard to differences in the amide-I region. The microscopic images support these findings, showing an alteration of the fiber orientation after treatment. For collagen-based biomaterials, such as pericardial tissue, the novel phenolic crosslinking agent proved to be an equivalent alternative to glutaraldehyde regarding tissue characteristics. Although long-term studies must be performed to investigate superiority in terms of longevity and calcification, our novel crosslinking agent can be applied in concentrations of 1.5% or 2.0% for the treatment of biomaterials.

4.
J Vis Exp ; (184)2022 06 08.
Artigo em Inglês | MEDLINE | ID: mdl-35758699

RESUMO

Transcatheter pulmonary valve replacement has been established as a viable alternative approach for patients suffering from right ventricular outflow tract or bioprosthetic valve dysfunction, with excellent early and late clinical outcomes. However, clinical challenges such as stented heart valve deterioration, coronary occlusion, endocarditis, and other complications must be addressed for lifetime application, particularly in pediatric patients. To facilitate the development of a lifelong solution for patients, transcatheter autologous pulmonary valve replacement was performed in an adult sheep model. The autologous pericardium was harvested from the sheep via left anterolateral minithoracotomy under general anesthesia with ventilation. The pericardium was placed on a 3D shaping heart valve model for non-toxic cross-linking for 2 days and 21 h. Intracardiac echocardiography (ICE) and angiography were performed to assess the position, morphology, function, and dimensions of the native pulmonary valve (NPV). After trimming, the crosslinked pericardium was sewn onto a self-expandable Nitinol stent and crimped into a self-designed delivery system. The autologous pulmonary valve (APV) was implanted at the NPV position via left jugular vein catheterization. ICE and angiography were repeated to evaluate the position, morphology, function, and dimensions of the APV. An APV was successfully implanted in sheep J. In this paper, sheep J was selected to obtain representative results. A 30 mm APV with a Nitinol stent was accurately implanted at the NPV position without any significant hemodynamic change. There was no paravalvular leak, no new pulmonary valve insufficiency, or stented pulmonary valve migration. This study demonstrated the feasibility and safety, in a long-time follow-up, of developing an APV for implantation at the NPV position with a self-expandable Nitinol stent via jugular vein catheterization in an adult sheep model.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Valva Pulmonar , Ligas , Animais , Criança , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Pericárdio/cirurgia , Desenho de Prótese , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/cirurgia , Ovinos , Stents
5.
J Vis Exp ; (179)2022 01 20.
Artigo em Inglês | MEDLINE | ID: mdl-35129181

RESUMO

The measurements of the right ventricle (RV) and pulmonary artery (PA), for selecting the optimal prosthesis size for transcatheter pulmonary valve replacement (TPVR), vary considerably. Three-dimensional (3D) computed tomography (CT) imaging for device size prediction is insufficient to assess the displacement of the right ventricular outflow tract (RVOT) and PA, which could increase the risk of stent misplacement and paravalvular leak. The aim of this study is to provide a dynamic model to visualize and quantify the anatomy of the RVOT to PA over the entire cardiac cycle by four-dimensional (4D) cardiac CT reconstruction to obtain an accurate quantitative evaluation of the required valve size. In this pilot study, cardiac CT from sheep J was chosen to illustrate the procedures. 3D cardiac CT was imported into 3D reconstruction software to build a 4D sequence which was divided into eleven frames over the cardiac cycle to visualize the deformation of the heart. Diameter, cross-sectional area, and circumference of five imaging planes at the main PA, sinotubular junction, sinus, basal plane of the pulmonary valve (BPV), and RVOT were measured at each frame in 4D straightened models prior to valve implantation to predict the valve size. Meanwhile, dynamic changes in the RV volume were also measured to evaluate right ventricular ejection fraction (RVEF). 3D measurements at the end of the diastole were obtained for comparison with the 4D measurements. In sheep J, 4D CT measurements from the straightened model resulted in the same choice of valve size for TPVR (30 mm) as 3D measurements. The RVEF of sheep J from pre-CT was 62.1 %. In contrast with 3D CT, the straightened 4D reconstruction model not only enabled accurate prediction for valve size selection for TPVR but also provided an ideal virtual reality, thus presenting a promising method for TPVR and the innovation of TPVR devices.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Valva Pulmonar , Animais , Cateterismo Cardíaco/métodos , Tomografia Computadorizada Quadridimensional , Implante de Prótese de Valva Cardíaca/métodos , Projetos Piloto , Desenho de Prótese , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/cirurgia , Estudos Retrospectivos , Ovinos , Volume Sistólico , Resultado do Tratamento , Função Ventricular Direita
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA