Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
2.
Can J Aging ; : 1-7, 2024 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-38268103

RESUMO

This study aimed to develop an efficient data collection and curation process for all drugs and natural health products (NHPs) used by participants to the Canadian Longitudinal Study on Aging (CLSA). The three-step sequential process consisted of (a) mapping drug inputs collected through the CLSA to the Health Canada Drug Product Database (DPD), (b) algorithm recoding of unmapped drug and NHP inputs, and (c) manual recoding of unmapped drug and NHP inputs. Among the 30,097 CLSA comprehensive cohort participants, 26,000 (86.4%) were using a drug or an NHP with a mean of 5.3 (SD 3.8) inputs per participant user for a total of 137,366 inputs. Of those inputs, 70,177 (51.1%) were mapped to the Health Canada DPD, 20,729 (15.1%) were recoded by algorithms, and 44,108 (32.1%) were manually recoded. The Direct algorithm correctly classified 99.4 per cent of drug inputs and 99.5 per cent of NHP inputs. We developed an efficient three-step process for drug and NHP data collection and curation for use in a longitudinal cohort.

3.
J Rheumatol ; 42(9): 1582-6, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26178277

RESUMO

OBJECTIVE: Assess the reliability of early erosions in rheumatoid arthritis (EERA) software for quantifying erosive damage to the metacarpophalangeal joints of patients with rheumatoid arthritis (RA). METHODS: One hundred magnetic resonance image sets from 68 patients with early referral RA were evaluated. Reliability was assessed using 95% limits of agreement and intraclass correlation coefficient (ICC) with 95% CI. RESULTS: Limits of agreement linearly depended on erosion volume: 0.44× between readers and 0.19× within readers. Interrater ICC was 0.976 (95% CI 0.965-0.984) and intrarater ICC was 0.996 (95% CI 0.994-0.997). CONCLUSION: EERA is highly reproducible for quantifying erosions in patients with early RA.


Assuntos
Artrite Reumatoide/patologia , Processamento de Imagem Assistida por Computador/métodos , Articulação Metacarpofalângica/patologia , Idoso , Algoritmos , Progressão da Doença , Feminino , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Índice de Gravidade de Doença
4.
Can Assoc Radiol J ; 60(2): 63-8, 2009 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-19433035

RESUMO

OBJECTIVE: The principal aim of this study was to create a segmentation program, to be used by nonmusculoskeletal or junior fellows, that defines the bones in the metacarpophalangeal joint in a dynamic 3-dimensional image that will lead to higher inter-reader agreement of bone erosion scores. METHODS: The second to fifth metacarpal head and phalangeal bases of 15 participants were rated according to the Rheumatoid Arthritis Magnetic Resonance Imaging Scoring system by one trained and one untrained reader. Two comparisons were made. The first comparison was between the 2 readers using only the traditional 2-dimensional magnetic resonance image set. The second comparison was between the 2 readers, with the untrained reader using a custom segmentation program with traditional 2-dimensional magnetic resonance image set. RESULTS: The software marginally increased inter-reader reliability with the exception of the second metacarpal head, for which reliability was increased substantially. Future work will concentrate on improving image acquisition, better delineate erosions from surrounding bone oedema, and address methods to directly determine erosion volumes. CONCLUSIONS: Software designed to display dynamic 3-dimensional images enables a relatively untrained user to score the metacarpophalangeal joints in the hand for erosions equivalent to that produced by an expert using the manual methods.


Assuntos
Artrite Reumatoide/diagnóstico , Articulação Metacarpofalângica/patologia , Software , Artrite Reumatoide/patologia , Progressão da Doença , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Variações Dependentes do Observador , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA