Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Int J Oral Implantol (Berl) ; 12(2): 181-194, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31090749

RESUMO

PURPOSE: To evaluate whether there is a difference in aesthetic outcomes positioning immediate post-extractive implants in the natural position (where the tooth should have been in relation to adjacent teeth/implants) or approximately 3 mm more palatally. MATERIALS AND METHODS: Just after tooth extraction, 20 patients requiring one single immediate maxillary post-extractive implant, from second premolar to second premolar, were randomly allocated to receive either an implant positioned in the natural 'central' position where the tooth should have been (central group; 10 patients) or approximately 3 mm more palatally (palatal group; 10 patients) according to a parallel-group design at two different centres. When needed, sites were reconstructed and bone-to-implant gaps were filled with granules of anorganic bovine bone, covered by resorbable collagen barriers. Implants were left submerged for 4 months and rehabilitated with provisional crowns, replaced after 4 months by metal-ceramic definitive crowns. Patients were followed to 3 years after loading. Outcome measures were: crown and implant failures, complications, aesthetics assessed using the pink aesthetic score (PES), peri-implant marginal bone level changes and patient satisfaction, recorded by blinded assessors. RESULTS: Three patients from each group dropped out up to 3 years after loading. One implant failed in each group (14%), the difference being not statistically significant (difference in proportion = 0.00; 95% CI: -0.39 to 0.39; P = 1.000). Two palatal group patients and one natural position patient had a complication each, the difference being not statistically significant (difference in proportion = 0.14; 95% CI: -0.28 to 0.52; P = 1.000). Three years after loading, the median PES was 12.5 (interquartile range [IQR] 5.0) for the central and 10.0 (IQR 10.0) for the palatal group, the difference being not statistically significant (median difference = -1.5; 95% CI: -10.0 to 5.0; P = 0.476). Three years after loading, patients of the central group lost 0.25 (IQR 0.40) mm of peri-implant marginal bone and those of the palatal group 0.20 (IQR 0.88) mm, the difference being not statistically significant (median difference = 0.15 mm; P [Mann-Whitney U test] = 0.486). Patients of both groups were equally satisfied at 3 years after loading for both function and aesthetics (both P = 0.699). CONCLUSIONS: These preliminary results suggest that positioning of immediate post-extractive implants 3 mm more palatally may not improve aesthetics; however, the sample size of the present study was very limited, thus larger trials are needed to confirm or reject the present findings. Conflict of interest statement: Mozo-Grau, Valladolid, Spain, the manufacturer of the implants used in this investigation, donated the implants and partially supported this trial; however, data belonged to the authors and by no means did the sponsor interfere with the conduct of the trial or the publication of its results.


Assuntos
Implantes Dentários para Um Único Dente , Carga Imediata em Implante Dentário , Animais , Transplante Ósseo , Bovinos , Implantação Dentária Endóssea , Estética , Estética Dentária , Humanos , Espanha
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA