Respir Care ; 2024 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-38981652

RESUMO

BACKGROUND: High-flow nasal cannula (HFNC) systems employ different methods to provide aerosol to patients. This study compared delivery efficiency, particle size, and regional deposition of aerosolized bronchodilators during HFNC in neonatal, pediatric, and adult upper-airway and lung models between a proximal aerosol adapter and distal aerosol circuit chamber. METHODS: A filter was connected to the upper airway to a spontaneously breathing lung model. Albuterol was nebulized using the aerosol adapter and circuit at different clinical flow settings. The aerosol mass deposited in the upper airway and lung was quantified. Particle size was measured with a laser diffractometer. Regional deposition was assessed with a gamma camera at each nebulizer location and patient model with minimum flow settings. RESULTS: Inhaled lung doses ranged from 0.2-0.8% for neonates, 0.2-2.2% for the small child, and 0.5-5.2% for the adult models. Neonatal inhaled lung doses were not different between the aerosol circuit and adapter, but the aerosol circuit showed marginally greater lung doses in the pediatric and adult patient models. Impacted aerosols and condensation in the non-heated HFNC and aerosol delivery components contributed to the dispersion of coarse liquid droplets, high deposition (11-44%), and occlusion of the supine neonatal upper airway. In contrast, the upright pediatric and adult upper-airway models had minimal deposition (0.3-7.0%) and high fugitive losses (∼24%) from liquid droplets leaking out of the nose. The high impactive losses in the aerosol adapter (56%) were better contained than in the aerosol circuit, resulting in less cannula sputter (5% vs 22%), fewer fugitive losses (18% vs 24%), and smaller inhaled aerosols (5 µm vs 13 µm). CONCLUSIONS: The inhaled lung dose was low (1-5%) during HFNC. Approaches that streamline aerosol delivery are needed to provide safe and effective therapy to patients receiving aerosolized medications with this HFNC system.

2.
Pharmaceutics ; 15(10)2023 Sep 22.
Artigo em Inglês | MEDLINE | ID: mdl-37896128

RESUMO

Aerosolized lung surfactant therapy during nasal continuous positive airway pressure (CPAP) support avoids intubation but is highly complex, with reported poor nebulizer efficiency and low pulmonary deposition. The study objective was to evaluate particle size, operational compatibility, and drug delivery efficiency with various nasal CPAP interfaces and gas humidity levels of a synthetic dry powder (DP) surfactant aerosol delivered by a low-flow aerosol chamber (LFAC) inhaler combined with bubble nasal CPAP (bCPAP). A particle impactor characterized DP surfactant aerosol particle size. Lung pressures and volumes were measured in a preterm infant nasal airway and lung model using LFAC flow injection into the bCPAP system with different nasal prongs. The LFAC was combined with bCPAP and a non-heated passover humidifier. DP surfactant mass deposition within the nasal airway and lung was quantified for different interfaces. Finally, surfactant aerosol therapy was investigated using select interfaces and bCPAP gas humidification by active heating. Surfactant aerosol particle size was 3.68 µm. Lung pressures and volumes were within an acceptable range for lung protection with LFAC actuation and bCPAP. Aerosol delivery of DP surfactant resulted in variable nasal airway (0-20%) and lung (0-40%) deposition. DP lung surfactant aerosols agglomerated in the prongs and nasal airways with significant reductions in lung delivery during active humidification of bCPAP gas. Our findings show high-efficiency delivery of small, synthetic DP surfactant particles without increasing the potential risk for lung injury during concurrent aerosol delivery and bCPAP with passive humidification. Specialized prongs adapted to minimize extrapulmonary aerosol losses and nasal deposition showed the greatest lung deposition. The use of heated, humidified bCPAP gases compromised drug delivery and safety. Safety and efficacy of DP aerosol delivery in preterm infants supported with bCPAP requires more research.

3.
Respir Care ; 65(7): 984-993, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32071129

RESUMO

BACKGROUND: There is limited evidence supporting an optimum method for removing mucus from the airways of hospitalized infants with bronchiolitis. This study was designed to evaluate short-term physiologic effects between nasal aspiration and nasopharyngeal suctioning in infants. METHODS: Sixteen infants requiring hospitalization for supportive management of bronchiolitis were instrumented with transcutaneously measured partial pressure of carbon dioxide ([Formula: see text]) and [Formula: see text] monitoring. Electrical impedance tomography (EIT) was used to estimate changes in inspiratory and end-expiratory lung volume loss and recovery. Subjects were suctioned with both nasal aspiration and nasopharyngeal suctioning methods in a randomized order (8 received nasal aspiration followed by nasopharyngeal suctioning, and 8 received nasophayrgeal suctioning followed by nasal aspiration). Noninvasive gas exchange and EIT measurements were obtained at baseline (pre-suction) and at 10, 20, and 30 min following each suctioning intervention. Sputum mass was obtained following suctioning, and clinical respiratory severity scores, before and after suctioning, were computed. RESULTS: There were no differences in inspiratory EIT (P = .93), change in end-expiratory lung impedance (ΔEELI; P = .53), [Formula: see text] (P = .41), [Formula: see text] (P = .88), heart rate (P = .31), or breathing frequency (P = .15) over the course of suctioning between nasal aspiration and nasopharyngeal suctioning. Sputum mass (P = .14) and clinical respiratory score differences before and after suctioning (P = .59) were not different between the 2 suctioning interventions. Sputum mass was not associated with ΔEELI at 30 min for nasal aspiration (ρ = 0.11, P = .69), but there was a moderate positive association for nasopharyngeal suctioning (ρ = 0.50, P = .048). CONCLUSIONS: Infants with viral bronchiolitis appeared to tolerate both suctioning techniques without adverse short-term physiologic effects, as indicated by the unchanged gas exchange and estimated lung volumes (EIT). Nasopharyngeal suctioning recovered 36% more sputum than did nasal aspiration and there was moderate correlation between sputum mass and end-expiratory lung impedance change at 30 minutes post-suction with nasopharyngeal that was not present with nasal aspiration. It is possible that a subset of patients may benefit from one type of suctioning over another. Future research focusing on important outcomes for suctioning patients with bronchiolitis with varying degrees of lung disease severity is needed.


Assuntos
Bronquiolite Viral , Bronquiolite , Bronquiolite/terapia , Bronquiolite Viral/terapia , Impedância Elétrica , Humanos , Lactente , Medidas de Volume Pulmonar , Sucção/efeitos adversos