Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Clin Appl Thromb Hemost ; 26: 1076029620959724, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32970454

RESUMO

Use of left ventricular assist devices (LVADs) for management of advanced heart failure is becoming increasingly common; however, device associated thrombosis remains an important cause of mortality in this patient population. We hypothesize that inflammation in LVAD implanted patients dysregulates the protein C pathway, creating a hypercoagulable state leading to thrombosis. Plasma samples from 22 patients implanted with the Thoratec HeartMate II LVAD were analyzed by commercial ELISAs. Retrospective sample selection included those collected 1-3 months prior to and within 1 month after a thrombotic or bleeding event. Unrelated to warfarin dosing, total protein S and free protein S (p = 0.033) levels were 20% lower in patients with LVAD-thrombosis than in patients with LVAD-bleeding. Levels of protein C, soluble endothelial cell protein C receptor, and soluble thrombomodulin were similar in both groups before and after the event. Compared to normal, C-reactive protein levels were 25-fold elevated in LVAD-thrombosis patients but only 9-fold elevated in LVAD-bleeding patients. This study suggests that protein S, influenced by the inflammatory state, is a gatekeeper for the function of protein C in patients with LVAD-associated thrombosis.


Assuntos
Insuficiência Cardíaca/fisiopatologia , Coração Auxiliar/normas , Inflamação/fisiopatologia , Proteína C/fisiologia , Trombose/fisiopatologia , Feminino , Humanos , Masculino
2.
Clin Appl Thromb Hemost ; 24(9_suppl): 294S-300S, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30419766

RESUMO

Heparin (H) anticoagulation in populations characterized by elevated platelet factor 4 (PF4) frequently elicits PF4/H antibodies, presenting a risk of heparin-induced thrombocytopenia. Recent studies have shown that anti-PF4/H enzyme-linked immunosorbent assays (ELISAs) detect antibodies in individuals never exposed to heparin. Platelet factor 4/H cross-reactive antibodies may result from PF4-mediated defense responses to injury or infection. This study questioned whether patients with diabetes are more likely to develop the endogenous cross-reactive antibodies. A comparison of healthy volunteers versus hospitalized patients with or without diabetes showed no significant differences in the prevalence of PF4/H ELISA-positive results. However, the group of patients who had both diabetes and an infectious condition had higher median antibody titer compared to other patients with or without diabetes regardless of reason for hospitalization. Higher PF4/H titers were also associated with patients with diabetes who were not on any medical therapy. In the future, determining whether PF4/H cross-reactive antibodies sensitize patients to respond adversely to heparin anticoagulation or predispose patients to other complications may be relevant to diabetes care.


Assuntos
Autoanticorpos/sangue , Diabetes Mellitus/sangue , Heparina/efeitos adversos , Trombocitopenia/sangue , Trombocitopenia/induzido quimicamente , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Autoanticorpos/imunologia , Reações Cruzadas , Diabetes Mellitus/tratamento farmacológico , Diabetes Mellitus/imunologia , Feminino , Heparina/administração & dosagem , Humanos , Masculino , Pessoa de Meia-Idade , Fator Plaquetário 4/imunologia , Fator Plaquetário 4/metabolismo , Trombocitopenia/imunologia
3.
Clin Appl Thromb Hemost ; 24(6): 965-972, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-29552914

RESUMO

Heart failure affects over 5 million people in the United States. Its rising prevalence and the limited supply of donor hearts is increasing the use of mechanical cardiac support with the implantation of continuous-flow ventricular assist devices (CF-VAD). Patients with CF-VAD implants are at risk of complications, specifically adverse hemostatic events such as nonsurgical bleeding and thrombosis. Development of a pump thrombus requires clinical intervention and/or surgical replacement significantly increasing the risk of patient morbidity and mortality. Identification of biomarkers for these events could improve current risk assessment models, subsequent treatment, and quality of life prognoses for VAD-implanted patients. The standard means for identifying thrombus in VAD patients is currently limited to monitoring levels of lactate dehydrogenase (>2× upper limit of normal), which is incapable of predicting a future event, but describes the risk of a present thrombus. Surface-enhanced laser desorption ionization time-of-flight mass spectrometry is a technique used to identify biomarkers. In this study, 3 groups of unique peaks were identified in plasma from patients with left ventricular assist devices: 8.1-kDa, 11.7-kDa, and a 15.2-/16.1-kDa pair. Unique correlations were found for each peak, respectively, with microparticles (MPs) and MP procoagulant activity, C-reactive protein, and MP-tissue factor. Furthermore, the use of 8.1-kDa peaks may be able to differentiate thrombotic events from other hemostatic events.


Assuntos
Proteínas Sanguíneas/metabolismo , Coração Auxiliar/efeitos adversos , Hemorragia , Trombose , Biomarcadores/sangue , Feminino , Hemorragia/sangue , Hemorragia/etiologia , Humanos , Masculino , Fatores de Risco , Trombose/sangue , Trombose/etiologia
4.
Clin Appl Thromb Hemost ; 19(5): 482-7, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23780399

RESUMO

Due to the pronounced hypercoagulable state in heparin-induced thrombocytopenia (HIT), alternatives to heparin that do not interact with HIT antibodies are needed for anticoagulation management. This study was designed to determine whether the oral factor Xa inhibitor apixaban could be used. Functional platelet activation with apixaban in the presence of HIT antibodies was evaluated by the (14)C-serotonin release assay (SRA; washed platelets) and the heparin-induced platelet aggregation assay (PA-HIT; platelet-rich plasma). A consistent absence of platelet activation by apixaban (0.05-50 µg/mL) was observed: SRA (n = 35) 11 ± 4% and PA-HIT (n = 37) 8 ± 3% (mean ± standard error of the mean; positive is >20%) versus heparin (0.1 U/mL) 82 ± 3% SRA and 78 ± 6% PA-HIT (P < 0.01) versus enoxaparin (10 µg/mL) 73 ± 5% SRA and 62 ± 7% PA-HIT. Apixaban may provide an option for oral anticoagulation in patients with HIT, particularly for extended management and prevention.


Assuntos
Anticoagulantes/administração & dosagem , Heparina/efeitos adversos , Pirazóis/administração & dosagem , Piridonas/administração & dosagem , Trombocitopenia/induzido quimicamente , Trombocitopenia/tratamento farmacológico , Anticoagulantes/efeitos adversos , Plaquetas/efeitos dos fármacos , Plaquetas/imunologia , Feminino , Humanos , Masculino , Pirazóis/efeitos adversos , Piridonas/efeitos adversos , Serotonina/sangue , Trombocitopenia/sangue , Trombocitopenia/imunologia
5.
Clin Appl Thromb Hemost ; 19(1): 37-41, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-22826445

RESUMO

Quality control of the platelet activation assays to diagnose heparin-induced thrombocytopenia (HIT), (14)C-serotonin release assay (SRA) and platelet aggregation test (PAT) has yet to be established due to lack of reference standards and the difficulty of obtaining significant amounts of HIT antibodies from patients with HIT. We prepared a murine monoclonal antibody to human platelet factor 4 (hPF4)/heparin complexes (HIT-MoAb) and investigated the platelet activating action of HIT-MoAb by using SRA and PAT. The HIT-MoAb activated human platelets at low heparin concentration and the platelet activations were inhibited at high heparin concentration in both SRA and PAT. The HIT-MoAb produced a concentration-dependent effect. Moreover, the platelet activation at low heparin concentration was inhibited by anti-FcγRIIa antibody. These results indicated that HIT-MoAb has characteristics similar to human HIT antibodies regarding heparin-dependent platelet activation. Therefore, it is suggested that HIT-MoAb has the potential to be a positive control or reference standard in platelet activation assays.


Assuntos
Anticorpos Monoclonais Murinos/química , Anticoagulantes/efeitos adversos , Anticoagulantes/sangue , Heparina/efeitos adversos , Heparina/sangue , Fator Plaquetário 4/sangue , Trombocitopenia/sangue , Trombocitopenia/induzido quimicamente , Animais , Anticorpos Monoclonais Murinos/imunologia , Anticoagulantes/uso terapêutico , Feminino , Heparina/uso terapêutico , Humanos , Camundongos , Camundongos Endogâmicos BALB C , Agregação Plaquetária/efeitos dos fármacos , Fator Plaquetário 4/imunologia , Testes de Função Plaquetária/métodos , Testes de Função Plaquetária/normas , Padrões de Referência , Trombocitopenia/imunologia
6.
Clin Appl Thromb Hemost ; 19(3): 261-7, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23091283

RESUMO

Enoxaparin, a complex, biologically derived low-molecular-weight heparin, is approved for a range of clinical indications. This study was carried out to compare the potency profile and pharmacodynamic responses of branded enoxaparin (Lovenox; Sanofi, US) with a generic enoxaparin (enoxaparin sodium injection, USP). Five batches of each product were tested. Although the average molecular weight, anti-factor Xa, and anti-factor IIa potencies were similar for the two products, differences were observed in the in vitro thrombin generation and kinetics of clot formation (P = .01) and in the ex vivo pharmacodynamics regarding thrombin generation inhibition (P = .029), tissue factor pathway inhibitor release (P = .006), and inhibition of the active form of thrombin-activated fibrinolysis inhibitor (P = .023). These findings suggest that simple analytical characterization can establish good quality control in manufacturing, but they may not assure similarity in biological performance between the branded and the generic enoxaparin.


Assuntos
Anticoagulantes/farmacologia , Medicamentos Genéricos/farmacologia , Enoxaparina/farmacologia , Área Sob a Curva , Humanos
7.
Clin Appl Thromb Hemost ; 19(3): 249-55, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23162019

RESUMO

Left ventricular assist devices (LVADs) are mechanical pumps that enhance cardiac function in patients with heart failure. In all, 7 patients with an LVADs (1.8 international normalized ratio warfarin, 81 mg aspirin) were evaluated monthly for 3 months for platelet and coagulation activation (controls: 5 healthy adults and 5 patients having warfarin). Platelet works revealed greater inhibition of collagen (31.8% vs 7.9%; P = .004), arachidonate- (30.9% vs 8.2%; P = .001), and adenosine diphosphate- (10.9% vs 6.1%; P = .004)-induced platelet aggregation for LVADs. Thrombelastography (recalcified whole blood) showed inhibition of clot initiation time (R; 8.81 vs 6.02 min; P = .001) and stronger clot formation (maximum amplitude; 69.1 vs 64.9 mm; P = .016). Platelet function determined by plateletMapping and flow cytometry was within the normal range. The LVADs had increased ratio of von Willebrand Factor (vWF) antigen and vWF propeptide, indicating increased degradation of vWF (2.04 vs 1.44; P = .144). Coagulation and platelet activation caused by LVAD is suppressed by pharmacotherapy, yielding a profile similar to that of patients on warfarin alone.


Assuntos
Anticoagulantes/uso terapêutico , Coagulação Sanguínea , Coração Auxiliar , Ativação Plaquetária , Adulto , Idoso , Feminino , Citometria de Fluxo , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Tromboelastografia
8.
Platelets ; 23(1): 69-80, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-21736539

RESUMO

Heparin-induced thrombocytopenia (HIT) is caused by antibodies, elicited in response to heparin anticoagulant therapy, which can cause extreme platelet activation and result in a highly procoagulant state. Most diagnostic tests for HIT antibodies measure in vitro platelet activation by detecting aggregation or granule release responses. This study demonstrates that the high level of activation by HIT antibodies leads to a rapid breakdown of platelet metabolic activity. Resting or mildly activated platelets metabolize tetrazolium-based indicator dye to a dark colored product, in proportion to cell concentration and dye incubation time. Highly activated, procoagulant platelets resulting from incubation with HIT antibodies fail to metabolize dye and remain light in color. The loss of ability to metabolically reduce indicator dye provides a colorimetric endpoint that can be used in an in vitro washed platelet activation assay to detect HIT antibodies. In a prospective evaluation, 145 diagnostic specimens were tested concurrently by both the colorimetric, dye reduction assay and the clinical laboratory standard, radiolabeled-serotonin release assay ((14)C-SRA). Results were in agreement for 96-100% of cases, depending on the chosen stringency of assay cut-off values. This study demonstrates that the metabolic dye reduction assay is comparable to the (14)C-SRA for HIT diagnosis. In addition, this novel assay may have even wider applicability, facilitating studies on the physiologic and clinical relevance of highly activated platelet populations.


Assuntos
Anticoagulantes/efeitos adversos , Plaquetas/metabolismo , Heparina/efeitos adversos , Ativação Plaquetária , Trombocitopenia , Colorimetria/métodos , Corantes/química , Feminino , Formazans/química , Humanos , Masculino , Oxirredução , Testes de Função Plaquetária/métodos , Trombocitopenia/sangue , Trombocitopenia/induzido quimicamente , Trombocitopenia/diagnóstico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA