Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Phys Imaging Radiat Oncol ; 23: 54-59, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35814259

RESUMO

Background/Purpose: Tomotherapy may deliver high-quality whole breast irradiation at static angles. The aim of this study was to implement Knowledge-Based (KB) automatic planning for left-sided whole breast using this modality. Materials/Methods: Virtual volumetric plans were associated to the dose distributions of 69 Tomotherapy (TT) clinical plans of previously treated patients, aiming to train a KB-model using a commercial tool completely implemented in our treatment planning system. An individually optimized template based on the resulting KB-model was generated for automatic plan optimization. Thirty patients of the training set and ten new patients were considered for internal/external validation. Fully-automatic plans (KB-TT) were generated and compared using the same geometry/number of fields of the corresponding clinical plans. Results: KB-TT plans were successfully generated in 26/30 and 10/10 patients of the internal/external validation sets; for 4 patients whose original plans used only two fields, the manual insertion of one/two fields before running the automatic template was sufficient to obtain acceptable plans. Concerning internal validation, planning target volume V95%/D1%/dose distribution standard deviation improved by 0.9%/0.4Gy/0.2Gy (p < 0.05) against clinical plans; Organs at risk mean doses were also slightly improved (p < 0.05) by 0.07/0.4/0.2/0.01 Gy for left lung/heart/right breast/right lung respectively. Similarly satisfactory results were replicated in the external validation set. The resulting treatment duration was 8 ± 1 min, consistent with our clinical experience. The active planner time per patient was 5-10 minutes. Conclusion: Automatic TT left-sided breast KB-plans are comparable to or slightly better than clinical plans and can be obtained with limited planner time. The approach is currently under clinical implementation.

2.
Radiother Oncol ; 175: 10-16, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35868603

RESUMO

PURPOSE: To quantify inter-institute variability of Knowledge-Based (KB) models for right breast cancer patients treated with tangential fields whole breast irradiation (WBI). MATERIALS AND METHODS: Ten institutions set KB models by using RapidPlan (Varian Inc.), following previously shared methodologies. Models were tested on 20 new patients from the same institutes, exporting DVH predictions of heart, ipsilateral lung, contralateral lung, and contralateral breast. Inter-institute variability was quantified by the inter-institute SDint of predicted DVHs/Dmean. Association between lung sparing vs PTV coverage strategy was also investigated. The transferability of models was evaluated by the overlap of each model's geometric Principal Component (PC1) when applied to the test patients of the other 9 institutes. RESULTS: The overall inter-institute variability of DVH/Dmean ipsilateral lung dose prediction, was less than 2% (20%-80% dose range) and 0.55 Gy respectively (1SD) for a 40 Gy in 15 fraction schedule; it was < 0.2 Gy for other OARs. Institute 6 showed the lowest mean dose prediction value and no overlap between PTV and ipsilateral lung. Once excluded, the predicted ipsilateral lung Dmean was correlated with median PTV D99% (R2 = 0.78). PC1 values were always within the range of applicability (90th percentile) for 7 models: for 2 models they were outside in 1/18 cases. For the model of institute 6, it failed in 7/18 cases. The impact of inter-institute variability of dose calculation was tested and found to be almost negligible. CONCLUSIONS: Results show limited inter-institute variability of plan prediction models translating in high inter-institute interchangeability, except for one of ten institutes. These results encourage future investigations in generating benchmarks for plan prediction incorporating inter-institute variability.


Assuntos
Neoplasias da Mama , Radioterapia Conformacional , Radioterapia de Intensidade Modulada , Humanos , Feminino , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Radioterapia Conformacional/métodos , Mama/efeitos da radiação , Neoplasias da Mama/radioterapia , Órgãos em Risco/efeitos da radiação
3.
Clin Breast Cancer ; 22(4): e480-e487, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-34955430

RESUMO

AIM: To report toxicity of hypofractionated whole-breast radiotherapy in a large cohort of early-stage breast cancer (BCaients. MATERIALS AND METHODS: From 02/2009-05/2017, 1325 consecutive BCa patients were treated with 40.05 Gy/15 fractions, without boost. Median age was 62 (IQR:51.1-70.5) years. Chemotherapy was prescribed for 28% of patients, hormonal therapy for 80.3%, monoclonal antibodies for 8.2%. RESULTS: Median follow-up was 72.4 (IQR: 44.6-104.1) months. Acute RTOG toxicity was: 69.8% Grade (G) 1, 14.3% G2 and 1.7% G3. Late SOMA-LENT toxicities were: edema-hyperpigmentation (E-H): G1 28.67%, G2 4.41%, G3 0.15%; fibrosis-atrophy-telangiectasia-pain (F-A-T-P): G1 14.6%, G2 3.2%, G3 0.8%, G4 0.1%. Median time to first occurrence was 6 and 18 months, respectively. Aesthetic result after surgery was excellent in 28.7%, good in 41.5%, acceptable in 20.3% and poor in 9.5% of patients. Change in breast appearance after radiotherapy was mild in 6.9%, moderate in 2.3% and marked in 1.3% of patients. Concomitant chemotherapy, obesity, smoking, use of bolus and planning target volume (PTV) were associated with higher acute toxicity. Patients ≥55 years old were less likely to experience acute toxicity. PTV and acute G2 toxicity were associated with ≥G2 E-H. PTV, concomitant chemotherapy, hypertension and ≥G2 acute toxicity were associated with increased risk of F-A-T-P. CONCLUSION: Hypofractionated whole-breast radiotherapy without boost demonstrated mild acute and late toxicity in a large cohort of consecutive patients. Moderate and marked changes in breast appearance were registered for 3.6% of patients and occurred between 18 to 42 months.


Assuntos
Neoplasias da Mama , Neoplasias da Mama/radioterapia , Neoplasias da Mama/cirurgia , Estudos de Coortes , Feminino , Humanos , Mastectomia Segmentar , Pessoa de Meia-Idade , Hipofracionamento da Dose de Radiação , Radioterapia Adjuvante/efeitos adversos
4.
Front Oncol ; 11: 712423, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34504790

RESUMO

PURPOSE: To implement Knowledge Based (KB) automatic planning for right and left-sided whole breast treatment through a new volumetric technique (ViTAT, Virtual Tangential-fields Arc Therapy) mimicking conventional tangential fields (TF) irradiation. MATERIALS AND METHOD: A total of 193 clinical plans delivering TF with wedged or field-in-field beams were selected to train two KB-models for right(R) and left(L) sided breast cancer patients using the RapidPlan (RP) tool implemented in the Varian Eclipse system. Then, a template for ViTAT optimization, incorporating individual KB-optimized constraints, was interactively fine-tuned. ViTAT plans consisted of four arcs (6 MV) with start/stop angles consistent with the TF geometry variability within our population; the delivery was completely blocked along the arcs, apart from the first and last 20° of rotation for each arc. Optimized fine-tuned KB templates for automatic plan optimization were generated. Validation tests were performed on 60 new patients equally divided in R and L breast treatment: KB automatic ViTAT-plans (KB-ViTAT) were compared against the original TF plans in terms of OARs/PTVs dose-volume parameters. Wilcoxon-tests were used to assess the statistically significant differences. RESULTS: KB models were successfully generated for both L and R sides. Overall, 1(3%) and 7(23%) out of 30 automatic KB-ViTAT plans were unacceptable compared to TF for R and L side, respectively. After the manual refinement of the start/stop angles, KB-ViTAT plans well fitted TF-performances for these patients as well. PTV coverage was comparable, while PTV D1% was improved with KB-ViTAT by R:0.4/L:0.2 Gy (p < 0.05); ipsilateral OARs Dmean were similar with a slight (i.e., few % volume) improvement/worsening in the 15-35 Gy/2-15 Gy range, respectively. KB-ViTAT better spared contralateral OARs: Dmean of contralateral OARs was 0.1 Gy lower (p < 0.05); integral dose was R:5%/L:8% lower (p < 0.05) than TF. The overall time for the automatic plan optimization and final dose calculation was 12 ± 2 minutes. CONCLUSIONS: Fully automatic KB-optimization of ViTAT can efficiently replace manually optimized TF planning for whole breast irradiation. This approach was clinically implemented in our institute and may be suggested as a large-scale strategy for efficiently replacing manual planning with large sparing of time, elimination of inter-planner variability and of, seldomly occurring, sub-optimal manual plans.

5.
Breast ; 55: 45-54, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33326894

RESUMO

AIM: We report molecular subtype impact on 1325 early breast cancer (BCa) patients treated with whole breast hypofractionated (WBH) adjuvant forward-planned intensity modulated radiotherapy (F-IMRT) without boost. METHODS AND MATERIALS: From 02/2009-05/2017 1325 patients with pTis-pT3, pNx-N1aM0 BCa who underwent breast conservation surgery were treated with WBHF-IMRT in our institute, to a total dose of 40 Gy/15 fractions, without boost. Median age: 62 (interquartile range-IQR-:51.14-70.53) years. HISTOLOGY: 8% in situ carcinoma (ISC), 92% invasive tumors. Molecular subtypes (invasive tumors): 49.9% Luminal A, 33.1% Luminal B Her2 negative (-), 6.2% Luminal B Her2 positive (+), 3.6% Hormone Receptor (HR)- Her2+, 7.1% Triple negative (TNBC), and 0.2% HR+. Chemotherapy (CT) was prescribed in 28% of patients, hormonal therapy in 80.3%, monoclonal antibodies (MAb) in 86.8% of Luminal B Her2+ and 97.7% of HR- Her2+ patients. RESULTS: Median follow up was 72.43 (IQR: 44.63-104.13) months. The 5-year Kaplan-Meier estimates of local relapse-free survival (LRFS) was 97.8%, regional-(RRFS) 98.6%, loco-regional- (LRRFS) 96.9%, distant- (DRFS) 96.6%, disease-free survival (DFS) 94.8% and overall survival (OS) 95.5%. Considering molecular subtypes, 5-year LRFS was: 99.8% for Luminal A, 96.7% for Luminal B Her2-, 94.1% for Luminal B Her2+, 87.9% for HR- Her2+, 95.1% for TNBC and 99.1% for in situ carcinoma. CONCLUSION: While the overall estimated probability of LR within 5 years after WBHF-IMRT without boost is good (2.2%), molecular subtypes have a strong impact, despite MAb therapy in Her2+ patients, and CT for TNBC patients, and could be used as a parameter in deciding the boost prescription.


Assuntos
Neoplasias da Mama , Neoplasias da Mama/radioterapia , Neoplasias da Mama/cirurgia , Intervalo Livre de Doença , Feminino , Humanos , Mastectomia Segmentar , Pessoa de Meia-Idade , Recidiva Local de Neoplasia , Hipofracionamento da Dose de Radiação , Receptor ErbB-2
6.
Phys Med ; 77: 160-168, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32866777

RESUMO

PURPOSE: To test the performances of a volumetric arc technique named ViTAT (Virtual Tangential-fields Arc Therapy) mimicking tangential field irradiation for whole breast radiotherapy. METHODS: ViTAT plans consisted in 4 arcs whose starting/ending position were established based on gantry angle distribution of clinical plans for right and left-breast. The arcs were completely blocked excluding the first and last 20°. Different virtual bolus densities and thicknesses were preliminarily evaluated to obtain the best plan performances. For 40 patients with tumor laterality equally divided between right and left sides, ViTAT plans were optimized considering the clinical DVHs for OARs (resulting from tangential field manual planning) to constrain them: ViTAT plans were compared with the clinical tangential-fields in terms of DVH parameters for both PTV and OARs. RESULTS: Distal angle values were suggested in the ranges [220°,240°] for the right-breast and [115°,135°] for the left-breast cases; medial angles were [60°,40°] for the right side and [295°,315°] for the left side, limiting the risk of collision. The optimal virtual bolus had -500 HU density and 1.5 cm thickness. ViTAT plans generated dose distributions very similar to the tangential-field plans, with significantly improved PTV homogeneity. The mean doses of ipsilateral OARs were comparable between the two techniques with minor increase of the low-dose spread in the range 2-15 Gy (few % volume); contralateral OARs were slightly better spared with ViTAT. CONCLUSION: ViTAT dose distributions were similar to tangential-fields. ViTAT should allow automatic plan optimization by developing knowledge-based DVH prediction models of patients treated with tangential-fields.


Assuntos
Neoplasias da Mama , Radioterapia de Intensidade Modulada , Mama , Neoplasias da Mama/radioterapia , Feminino , Humanos , Órgãos em Risco , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador
7.
Phys Med ; 57: 215-220, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30661743

RESUMO

PURPOSE: To report on the implementation, validation and results of the first two proton therapy PBS treatments of limited amplitudes moving targets performed at our center. METHODS AND MATERIALS: A real time optical tracking system was used to monitor the patient surface during the CT scan and treatment. This system is also able to trigger the beam during the treatment. A 4DCT (10 phases) and a Free-Breathing CT (FBCT) were used for the planning. The physician used the 4DCT for ITV delineation, while planning was performed on the FBCT. The approved plan was evaluated in two ways:The largest breathing amplitude recorded during 4DCT scan was used as gating safety threshold during treatment delivery. This planning and treatment workflow was then applied for two patients affected by thoracic thymoma. RESULTS: The dosimetric evaluation of the plan showed no interplay effect. The second patient showed an overdosage to the coronary and Left Anterior Descending area in the worst case scenario but it was below the constraints. Duty Cycle together with number of beam interruptions gave information about the patient compliance to the treatment: the first patient breath is stable and within thresholds, whilst the second patient had more variations, causing multiple beam interruptions. CONCLUSION: We defined and used for two patients a protocol for the treatment of small amplitude moving targets. The planning and delivery of the treatments gave very good results in terms of coverage, OARs sparing, 4D dose evaluation of the plan and interplay effect assessment.


Assuntos
Fracionamento da Dose de Radiação , Movimento , Terapia com Prótons/métodos , Tomografia Computadorizada Quadridimensional , Humanos , Planejamento da Radioterapia Assistida por Computador , Respiração , Timoma/diagnóstico por imagem , Timoma/fisiopatologia , Timoma/radioterapia , Neoplasias do Timo/diagnóstico por imagem , Neoplasias do Timo/fisiopatologia , Neoplasias do Timo/radioterapia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA