Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Empirica (Dordr) ; : 1-28, 2023 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-37362748

RESUMO

We test sustainability of the Italian government deficit over the period 1861-2020 using the fiscal theory of the price level (FTPL). This approach takes into account monetary and fiscal policy interactions and assumes that fiscal policy may determine the price level even if monetary authorities pursue an inflation-targeting strategy. We consider a cointegrated model with multiple structural changes to characterize the sustainability of public finances and the prevalence of monetary or fiscal dominance during subperiods. We also use recursive unit root tests for explosiveness to test fiscal sustainability and to detect episodes of potential explosive behaviour in Italian public debt. We find two structural changes for the public debt and one change in the primary budget surplus, the alternation of monetary and fiscal dominant regimes, as well as evidence of bubbles related to three episodes of the Italian fiscal performance. Our results reveal the sensitiveness of the primary balance and the debt paths to shocks hitting fiscal, macroeconomic, and financial variables.

2.
Animals (Basel) ; 11(12)2021 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-34944201

RESUMO

Quadratus lumborum block (QLB) is used to provide analgesia for abdominal surgery in humans. The aim of this study was to assess an anaesthetic protocol involving the QLB for canine ovariohysterectomy. Ten dogs were included. Anaesthetic protocol consisted of premedication with IM medetomidine (20 µg kg-1) and SC meloxicam (0.1 mg kg-1), induction with propofol to effect, and maintenance with sevoflurane in oxygen/medical air. QLB was performed injecting 0.4 mL kg-1 of 0.25% bupivacaine/iohexol per side. Computed Tomography (CT) was performed before and after surgery. Fentanyl was administered as rescue analgesia during surgery. The Short Form of The Glasgow Composite Pain Scale and thermal threshold (TT) at the level of the elbow, T10, T13 and L3 were assessed before premedication and every hour postoperatively. Methadone was given as rescue analgesia postoperatively when pain score was >3. A Yuen's test on trimmed means for dependent samples was used to analyse the data (p < 0.05). CT images showed spreading of the contrast/block for a median (range) of 3 (2-5) vertebrae, without differences between preoperative and postoperative images. One dog needed rescue analgesia during surgery. Pain score was less than 4/24 in all the animals during the first 4 h after surgery. TT showed a significant increased signal in all the areas tested, apart from the humerus, 30 min after surgery. The QLB may provide additional analgesia for canine ovariohysterectomy. Further studies are needed to assess the specific contribution of the QLB in abdominal analgesia.

3.
Animals (Basel) ; 11(10)2021 Oct 12.
Artigo em Inglês | MEDLINE | ID: mdl-34679966

RESUMO

Ultrasound-guided quadratus lumborum block (QLB) is a locoregional technique described in canine cadavers. The aim of this study was to assess a modified approach to QLB to minimise potential complications such as abdominal organ puncture. Nine canine cadavers were included and were positioned in lateral recumbency. An ultrasound-guided QLB was performed on each side. The probe was placed in the transverse position over the lumbar muscles just caudal to the last rib, and a needle was advanced in-plane from a dorso-lateral to a ventro-medial. A volume of 0.2 mL kg-1 of a mixture of iomeprol and methylene blue was injected. Computed tomography (CT) and dissection were performed to evaluate the spreading. Success was defined as staining of the nerve with a length of more than 0.6 cm. Potential complications such as intra-abdominal, epidural, or intravascular spreading of the mixture were also assessed. The CT images showed a T13 to L7 vertebra distribution, with a median of 5 (3-6). Dissection showed staining of the nerves from T13 to L4, with a median of 3 (2-5). No complications were found. This modified approach to QLB is safe and shows similar results to the previous studies in canine carcass.

4.
J Vet Sci ; 22(2): e22, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33774938

RESUMO

BACKGROUND: Standing surgery in horses combining intravenous sedatives, analgesics and local anaesthesia is becoming more popular. Ultrasound guided (USG) peribulbar nerve block (PB) has been described in dogs and humans for facial and ocular surgery, reducing the risk of complications versus retrobulbar nerve block (RB). OBJECTIVE: To describe a technique for USG PB in horse cadavers. METHODS: Landmarks and PB technique were described in two equine cadaver heads (Phase 1), with computed tomography (CT) imaging confirming contrast location and spread. In Phase 2, ten equine cadaver heads were randomised to two operators naïve to the USG PB, with moderate experience with ultrasonography and conventional "blind" RB. Both techniques were demonstrated once. Subsequently, operators performed five USG PB and five RB each, unassisted. Contrast location and spread were evaluated by CT. Injection site success was defined for USG PB as extraconal contrast, and for RB intraconal contrast. RESULTS: Success was 10/10 for USG PB and 0/10 for RB (p < 0.001). Of the RB injections, eight resulted in extraconal contrast and two in the masseter muscle (p = 0.47). CONCLUSIONS: The USG PB had a high injection site success rate compared with the RB technique; however, we cannot comment on clinical effect. The USG technique was easily learnt, and no potential complications were seen. The USG PB nerve block could have a wide application for use in horses for ocular surgeries (enucleations, eyelid, corneal, cataract surgeries, and ocular analgesia) due to reduced risk of iatrogenic damage. Further clinical studies are needed.


Assuntos
Bloqueio Nervoso/veterinária , Tomografia Computadorizada por Raios X/veterinária , Animais , Cadáver , Meios de Contraste/análise , Cabeça , Cavalos , Bloqueio Nervoso/métodos , Variações Dependentes do Observador
5.
Reg Anesth Pain Med ; 46(5): 389-396, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33504475

RESUMO

BACKGROUND: We designed a device to close accidental dural puncture via the offending puncturing epidural needle directly after diagnosis of the puncture and before removing the needle. The aim of this study was to quantify this device's ability to seal cerebrospinal fluid leakage. METHODS: Forty-six anesthetized adult sheep were studied in a single-blind randomized controlled fashion in two equal groups.An intentional dural puncture was performed with an 18-gage Tuohy needle on all the sheep between L6 and S1 levels. Contrast medium was injected through the needle. Twenty-three animals receive treatment with the sealing device. Two minutes after device placement, or dural puncture in the control group, a CT scan was performed on the animals to estimate contrast material leakage. A region of interest (ROI) was defined as the region that enclosed the subarachnoid space, epidural space, and neuroforaminal canal (the vertebral body above and half of its equivalent height in sacrum below the puncture site). In this region, the total contrast volume and the volumes in the epidural space (EPIDURAL) were measured. The primary outcome measure was the EPIDURAL/ROI ratio to ascertain the proportion of intrathecally injected fluid that passed into the epidural space in both groups. The secondary outcomes were the total amount of contrast in the ROI and the EPIDURAL. RESULTS: The device was deployed successfully in all but two instances, where it suffered from manufacturing defects.Leakage was less in the study group (1.0 vs 1.4 mL, p=0.008). The median EPIDURAL/ROI ratio was likewise less in the study group (29 vs 46; p=0.013; 95% CI (-27 to -3.5)). CONCLUSION: This novel dural puncture-sealing device, also envisaged to be used in other comparable iatrogenic leakage scenarios to be identified in the future, was able to reduce the volume of cerebrospinal fluid that leaked into the epidural space after dural puncture. The device is possibly a valuable way of preventing fluid leakage immediately after the recognition of membrane puncture.


Assuntos
Anestesia Epidural , Punção Espinal , Animais , Implantes Absorvíveis , Punções , Ovinos , Método Simples-Cego
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA