Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Int J Cardiol Heart Vasc ; 36(100853): 1-7, Oct. 2021. graf, tab
Artigo em Inglês | CONASS, Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1283815

RESUMO

BACKGROUND: Patients with Coronavirus Disease 2019 (COVID-19) may present high risk features during hospitalization, including cardiovascular manifestations. However, less is known about the factors that may further increase the risk of death in these patients. METHODS: We included patients with COVID-19 and high risk features according to clinical and/or laboratory criteria at 21 sites in Brazil from June 10th to October 23rd of 2020. All variables were collected until hospital discharge or in-hospital death. RESULTS: A total of 2546 participants were included (mean age 65 years; 60.3% male). Overall, 70.8% were admitted to intensive care units and 54.2% had elevated troponin levels. In-hospital mortality was 41.7%. An interaction among sex, age and mortality was found (p = 0.007). Younger women presented higher rates of death than men (30.0% vs 22.9%), while older men presented higher rates of death than women (57.6% vs 49.2%). The strongest factors associated with in-hospital mortality were need for mechanical ventilation (odds ratio [OR] 8.2, 95% confidence interval [CI] 5.4­12.7), elevated C-reactive protein (OR 2.3, 95% CI 1.7­2.9), cancer (OR 1.8, 95 %CI 1.2­2.9), and elevated troponin levels (OR 1.8, 95% CI 1.4­2.3). A risk score was developed for risk assessment of in-hospital mortality. CONCLUSIONS: This cohort showed that patients with COVID-19 and high risk features have an elevated rate of in-hospital mortality with differences according to age and sex. These results highlight unique aspects of this population and might help identifying patients who may benefit from more careful initial surveillance and potential subsequent interventional therapies


Assuntos
Mortalidade Hospitalar , Coronavirus , Medição de Risco
2.
Int J Cardiol Heart Vasc ; 36: 100853, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34345648

RESUMO

BACKGROUND: Patients with Coronavirus Disease 2019 (COVID-19) may present high risk features during hospitalization, including cardiovascular manifestations. However, less is known about the factors that may further increase the risk of death in these patients. METHODS: We included patients with COVID-19 and high risk features according to clinical and/or laboratory criteria at 21 sites in Brazil from June 10th to October 23rd of 2020. All variables were collected until hospital discharge or in-hospital death. RESULTS: A total of 2546 participants were included (mean age 65 years; 60.3% male). Overall, 70.8% were admitted to intensive care units and 54.2% had elevated troponin levels. In-hospital mortality was 41.7%. An interaction among sex, age and mortality was found (p = 0.007). Younger women presented higher rates of death than men (30.0% vs 22.9%), while older men presented higher rates of death than women (57.6% vs 49.2%). The strongest factors associated with in-hospital mortality were need for mechanical ventilation (odds ratio [OR] 8.2, 95% confidence interval [CI] 5.4-12.7), elevated C-reactive protein (OR 2.3, 95% CI 1.7-2.9), cancer (OR 1.8, 95 %CI 1.2-2.9), and elevated troponin levels (OR 1.8, 95% CI 1.4-2.3). A risk score was developed for risk assessment of in-hospital mortality. CONCLUSIONS: This cohort showed that patients with COVID-19 and high risk features have an elevated rate of in-hospital mortality with differences according to age and sex. These results highlight unique aspects of this population and might help identifying patients who may benefit from more careful initial surveillance and potential subsequent interventional therapies.

3.
Cardiovasc Revasc Med ; 18(7): 507-511, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29054156

RESUMO

BACKGROUND: Baseline comorbidities including renal dysfunction are frequently found in patients treated with transcatheter aortic valve replacement (TAVR) and may increase the risks of acute kidney injury (AKI), although some of them may actually improve renal function. We aimed to evaluate the potential of TAVR to acutely improve post-procedure renal function. METHODS: This is a prospective single-center registry of consecutive patients with severe symptomatic aortic stenosis treated by transfemoral TAVR. Creatinine levels were determined at baseline and daily until hospital discharge. AKI was defined according to VARC-2 criteria. Patients who had improvement of creatinine levels >25% were classified as having TAVR induced renal function improvement (TIRFI). RESULTS: A total of 69 patients undergoing TAVR were included, with a mean age of 83.0±7.4 years, being 24.6% diabetics, with a median STS score of 9.2 (5.1-21.6). Using the VARC-2 criteria, the majority of patients (64.6%) did not have renal impairment, while AKI was detected in 35.4% of the patients. Importantly, in those with prior severe renal dysfunction (clearance <30mL/min/1.73m2) or diabetes, AKI reached up to 50% and 56.3% of the patients, respectively. Conversely, acute kidney recovery (TIRFI) occurred in 12 patients (18.5%) being >50% in 1 patient (1.5%), and at hospital discharge the majority of the patients (88.6%) left the hospital in their original or better renal function categories. CONCLUSION: Despite multiple comorbidities in a selected TAVR-population and the use of contrast media, TAVR did not impair renal function in a majority of patients, with a significant proportion of them rather having acute renal function improvement.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Nefropatias/fisiopatologia , Rim/fisiopatologia , Substituição da Valva Aórtica Transcateter , Injúria Renal Aguda/diagnóstico , Injúria Renal Aguda/epidemiologia , Injúria Renal Aguda/fisiopatologia , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/epidemiologia , Estenose da Valva Aórtica/fisiopatologia , Biomarcadores/sangue , Brasil/epidemiologia , Comorbidade , Creatinina/sangue , Feminino , Taxa de Filtração Glomerular , Hemodinâmica , Humanos , Nefropatias/diagnóstico , Nefropatias/epidemiologia , Masculino , Recuperação de Função Fisiológica , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
4.
Case Rep Cardiol ; 2015: 703646, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26451260

RESUMO

Aneurysms of the sinus of Valsalva are very rare and mostly located in the right coronary sinus. They might course with dyspnea, fatigue, and acute coronary syndromes. We present herein an extremely rare case report of a 61-year-old woman diagnosed with external left main coronary compression by a giant aneurysm of the left sinus of Valsalva, which was successfully managed with percutaneous coronary intervention.

5.
Cardiovasc Diagn Ther ; 5(4): 264-70, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26331110

RESUMO

BACKGROUND: The Inspiron™ sirolimus-eluting stent (SES) is a low-dose, ultra-thin-strut cobalt-chromium stent abluminally coated with biodegradable polymers (BP). Previous results from the INSPIRON-I trial, a first-in-man study, have proven the efficacy of the novel stent in reducing neointimal proliferation. The present report aims at evaluating the long-term clinical outcomes of patients enrolled into the INSPIRON-I trial (Clinical Trials Gov. identifier: NCT01093391). METHODS: A total of 57 patients (60 lesions) were randomly allocated in a 2:1 ratio to treatment with the Inspiron™ SES vs. its equivalent Cronus™ bare metal stent (BMS, both by Scitech Medical™, Aparecida de Goiânia, Goiás, Brazil), in four tertiary centers. The primary endpoint of the present analysis was the occurrence of major adverse cardiac events (MACE) [death, myocardial infarction (MI), target vessel revascularization (TVR) and/or target lesion revascularization (TLR)] at 4 years. RESULTS: Baseline clinical and angiographic characteristics of both groups were similar. After 4 years, the primary endpoint occurred in 7.9% vs. 23.5% of patients in Inspiron and control groups respectively (P=0.11). The rate of death/MI was similar between the groups, but there was a significant decrease in the risk of repeat revascularization in the Inspiron group compared to the control arm TLR (0.0% vs. 23.5% respectively, P=0.02). There were no stent thromboses in the study population. CONCLUSIONS: The novel Inspiron™ SES showed a sustained safe and effective clinical profile after 4-year of follow-up, with very low adverse events and null stent thrombosis (ST) occurrence.

6.
Cardiovasc Diagn Ther ; 5(4): 264-270, 2015.
Artigo em Inglês | Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1061810

RESUMO

Background: The Inspiron™ sirolimus-eluting stent (SES) is a low-dose, ultra-thin-strut cobalt-chromium stent abluminally coated with biodegradable polymers (BP). Previous results from the INSPIRON-I trial, a first-in-man study, have proven the efficacy of the novel stent in reducing neointimal proliferation. The present report aims at evaluating the long-term clinical outcomes of patients enrolled into the INSPIRON-I trial (Clinical Trials Gov. identifier: NCT01093391).Methods: A total of 57 patients (60 lesions) were randomly allocated in a 2:1 ratio to treatment with the Inspiron™ SES vs. its equivalent Cronus™ bare metal stent (BMS, both by Scitech Medical™, Aparecida de Goiânia, Goiás, Brazil), in four tertiary centers. The primary endpoint of the present analysis was the occurrence of major adverse cardiac events (MACE) [death, myocardial infarction (MI), target vessel revascularization (TVR) and/or target lesion revascularization (TLR)] at 4 years.Results: Baseline clinical and angiographic characteristics of both groups were similar. After 4 years, the primary endpoint occurred in 7.9% vs. 23.5% of patients in Inspiron and control groups respectively (P=0.11)...


Assuntos
Intervenção Coronária Percutânea , Polímeros , Sirolimo , Stents Farmacológicos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA